| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-05-2026 | Tender Documents, NIT | Other | 26-05-2026 |
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: For thickness of tiles 25mm to 40mm. |
| 3 | Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 5 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 6 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 7 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 8 | Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles. |
| 9 | Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size. |
| 10 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. |
| 11 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 550 mm x 400 mm |
| 12 | P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make : C.P. Brass Push type 32mm nominal bore. |
| 13 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 (-do-) |
| 14 | Hoisting Charges for each floor : For items 2.26.1 to 2.26.4 |
| 15 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : Brass wt.Not less than 600 gm, 25mm. |
| 16 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 17 | 20mm nominal size |
| 18 | 25 mm nominal size |
| 19 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm |
| 20 | P & F Extension Pipe for bib cocks of approved quality/make. C.P. brass of Heavy & Superior quality 50x15mm |
| 21 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 22 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 35 mm thick . Commercial Veneer both side |
| 23 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 24 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 25 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Kota stone minimum 30mm thick. |
| 26 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 27 | Carriage of Building Rubbish Stone metal (Grit and ballast etc.) |
| 28 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 29 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 31 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 32 | Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 33 | Electrical Work |
| 34 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 35 | Short point (up to 3 mtr.) |
| 36 | Medium point (up to 6 mtr.) |
| 37 | Long point (up to 10 mtr.) |
| 38 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 39 | On board |
| 40 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 41 | 20 mm |
| 42 | 25 mm |
| 43 | 32 mm |
| 44 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 45 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 46 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 47 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 48 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. |
| 49 | 9 Watt |
| 50 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 51 | 5 step fan regulator 2 Module 360 dgree rotating |
| 52 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 53 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 54 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 55 | Surface Mounting (with extruded alumn. Housing ) |
| 56 | Minimum lumen output 1950 lm |
| 57 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 58 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 59 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 60 | 1 x 1.5 sq.mm |
| 61 | 4 x 6.0 sq.mm |
| 62 | 1 x 4.0 sq.mm |
| 63 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 64 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 65 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 66 | 6 Way |
| 67 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 68 | 8 Way (8+2) |
| 69 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 70 | Single pole MCB (With B/C curve tripping Characteristics) |
| 71 | 6 A to 32 A rating |
| 72 | Four pole MCB (With B/C curve tripping Characteristics) |
| 73 | 50/63 A rating |
| 74 | Triple pole MCB (With B/C curve trippingCharacteristics) |
| 75 | 50/63 A rating |
| 76 | Double pole MCB(With B/C curve tripping Characteristics) |
| 77 | 40 A rating |
| 78 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 79 | Modular MCB 6 A to 32 A SP |
| 80 | Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 81 | 300 mm sweep |
| 82 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 83 | 25.0 Sq. mm |
| 84 | 3.5 core |
| 85 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 86 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box |
| 87 | 4 Way |
| 88 | Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 89 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 90 | (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts |
| 91 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 92 | (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. |
| 93 | (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. |
| 94 | (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 95 | 17.2 mm thick and 3 Mtr. Long |
| 96 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 97 | 10 SWG copper. Wire |
| 98 | Providing & Fixing of following modular accessories as per PWDspecification for electrical Works, made out of unbreakable and fireretardant vergin poly carbonate with brass terminals and captive screws &silver alloy contact tip with IP-20 rating , including all as per pre approvedby Engineer in charge,making connections, testing etc. as required. Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR |
| 99 | RJ-11 telephone jack single line |
| 100 | P & F Krone module with base frame in the recess / surface made out of1.2 mm thick sheet steel box, front openable, having locking arrangementsduly powder painted,including dressing, ferruling and punching oftelephone cable with krone tool etc. as required. For additional technicalparameters of product / work refer Annexure 'A' attached with this BSR |
| 101 | 10 Pairs |
| 102 | Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic gradebare Copper Conductor as per IS: 8130/84 &confirming to TECspecification GR / WIR/06-03 March 2002 in existing surface orrecessed conduit/casing capping. including ferruling on each pair forIdentification etc. as required. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR |
| 103 | 2 pair |
| 104 | 10 pair |
| 105 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC,UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable asper latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balancedtwisted in pairs, seperated by a cross-member fluted pair divider & protected by PVCJacket. Certified performance in a 4-connector configuration upto 100 Mtrs channelrequirements & transmission frequencies up to 250 Mhz. in existing MS/PVCConduits/casing capping including making connections to Information outlets and PatchPanels with jack & ferruling at both ends for identification with necessary tools forpunching, stripping, crimping and testing etc as required complete in all respect. All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR . |
| 106 | Supply & fixing of square Faceplate for Flush / Surface Mount Information OutletsSingle/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions shouldbe 86mm X 86mm as required complete in all respect. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , refer Annexure \\"A\\"attached with this BSR |
| 107 | Single Aperture |
| 108 | Supply, Installation, Testing and Comissioning of Rack mounted 19\\" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), ModularPatch Panels with Rear Cable management system and mounting hardware to mount thepatch panel. Should have port identification numbersprinted/engraved on front of thepanel. Etc. as required.All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 109 | Modular Patch Panel Loaded with Cat -6 I/O |
| 110 | Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patchcords should be constructed of minimum 23/24 AWG, stranded bare Copper cable withFRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectorswith strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A applicationcomplying to latest ammendments Category 6/6A Standards, According. to TIA568C.2,ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirementfor 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cablecompatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af /IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts forlong durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digitalvideo and broadband/baseband analog video, Voice over internet protocal (VOIP).All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR . |
| 111 | Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord |
| 112 | 1 Mtr |
| 113 | Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,front sturdy sheet steel frame folded from one piece and welded with minimum 5mmtoughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All roundprotective channel on the door aperture, lock integrated on front door, top and bottomcover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angleswith wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cablemanager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long powerchord for supplying power to switches, fans etc along with earth continuity kit, indicator,moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.Allas per pre approved by Engineer in charge. For additional technical parametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR . |
| 114 | 9 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 115 | 6 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 116 | Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFPGiga Ports (provision for Fiber Giga connectivity) with related LANBase Software includingmaking connections etc as required.All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \\"A\\" attached with thisBSR |
| 117 | Supply and Installation of unsheilded/360 degree sheilded Information outlets made of highimpact plastic body with ABS, FR Grade halogen free material with provision for protectionagainst dust in jack, suitable for Cat 6/6A application complying to latest ammendments,According. to Cat. 6/6A channel, It should support channel as well as componentsrequirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6Aunshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWGsolid/strandedwire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jackshould have tooless/impact termination on reliable copper tin plated Insulationdisplacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and compliedwith ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Shouldsupport Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voiceover internet protocal (VOIP) Specifications in existing modular/MS Boxes along withnecessory connections as required.All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \\"A\\" attached with thisBSR . |
| 118 | Cat 6, Un-sheilded Information Outlet |
| 119 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 120 | 4 pole MCCB With Thermal Magnetic release |
| 121 | up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 122 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 123 | LED Street Light fixture with Minimum lumen output 8700 lm |
| 124 | SITC of IR IP Based 5 MP Dome camera : 1/2.8\\" Progressive CMOS, ICR, IR, 2560(H)xl920(V):25fps(P) , 2.8/3.6 mm lens (As per site requirement) H 264,H265/MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: minimum 30 Mtr, Provision for Support on-board storage up to 256 GB (SD card not included), intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G}, Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : 20°C - 50°C or better. Model should be: CE, BIS,/UL,FCC,ROHS compliance. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR. |
| 125 | SITC of IR IP based 5 MP Bullet Camera 5 MP, Video Resolution: 2592(H)x1944(V) Pixels , 1 to @25 fps; Image Sensor: 1/2.8-inch CMOS; Built in Infra-Red: 40 to 50 Mtr; High Dynamic Range- 120 dB WDR; Lense- 2.8/3.6 mm, ;H264,H265/MJPEG, provision for Support on-board storage up to 256 GB (SD card not included) , intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : -30°C to + 70 °C or better. Onvif Profile S, G, Confirmant; Model should be: CE, BIS,/UL, FCC, ROHS compliance The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \\"A\\" attached with this BSR. |
| 126 | Supply, Installation, Testing & Commissioning of 16 Ch NVR Pre-licensed, NVR supports up to 40 TB HOD Support, 16 Ch IP inputs; Support ANR technology; 320mbps incoming bandwidth, supports up to 12MP full channel recording; support H.265 compression; 16ch synchronized playback @1080p; support 3rd party cameras ONVlF type; 4K output; minimum 04 SATA HDD Slots; each slot should support up to 10 TB HDD; Dual gigabit self-adaptive Ethernet interface; serial interface; USB interface; (all cameras and Storage-NVR should be of same make for the smooth functioning of the system) complete with mounting accessories & junction box (to be provided by OEM) for cable management. Model should be: Certificates of Compliance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan. All as per pre approved by Engineer in charge. For additional technical parameters of products/work refer Annexure \\"A\\" attached with this BSR. |
| 127 | Supply, Installation, Testing & Commissioning of 3.5\\" 6 TB SATA, USB 3.0 Surveillance Hard Disk. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attachedwith this BSR |
| 128 | Supply, Installation, testing and commissioning of BIS compliance Professional series Diagonal Screen size 43\\" LED with Resolution 3,840 x 2,160 (4K UHD) along with Static (Panel) Contrast Ratio (1300:1) or better with viewing angle of 178/178 degree with response time of 8rns along with HDMI In 2.0 - 2 nos., USB 2.0 2 nos., RS 232- 1 nos., RJ 45- 1 Nos. with Built in Speaker (10W + 10W), with high speed processor and android or other reputated operating system along with 4 GB RAM along with all audio and video decoder, Stand-by/ sleep/ off mode power 0.5 watt. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR. |
| 129 | SITC of 8 port Giga PoE Switch with dual uplink : unmanaged PoE switch; 8Xl0/100/1000 mbps Base-T PoE; 2*10/100/1000 Base-T(Uplink) or 2*1000 Base-X (uplink); PoE Power Consumption per Port: <=30W; power budget: minimum 96 W; PoE Protocols: IEEE 802.3af, IEEE 802.3 at ;Switch Capacity: 20 Gbps or better; MAC Table Size 2K or better; Working Temperature: -5°C-55°C; Power supply:DC48-57V Certificate of compliance: CF/FCC. A11 as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with P.W.D. Electrical B.S.R. 2022. |
| 130 | Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 131 | 25 Amp. 2 Module Socket Please Enable Macros to View BoQ information |