| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/Maintenance of Fire Detection, Alarm and firefighting system of MAP Accns under GE (Utilities) Udhampur Contract No: GE/U-66/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Supply, fixing and testing of conventional manual call point 24V resettable type, each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion complete all as specified and directed by the Engineer-in-Charge. |
| 3 | Repairing and testing of existing unserviceable and manual call point including opening, soldering of circuits, cleaning, replacement of glass, testing and painting complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply fixing and testing loop powered sounder strobe 24V. Dual tone hooter shall be of electronic type and shall give discontinuous/ intermittent audible alaram. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion and complete all as specified and directed by the Engineer-in-Charge. |
| 5 | Dismantling the existing loop sounder by disconnecting device by movable ladder, dismantling cap & sensor board, cleaning the parts using CRC solution and check the control wiring circuit the PCB board , communication panel, device controlled by a programme, device sound & fire red flash light indication while fire activate and re addressing & re installation work complete all as specified and directed by the Engineer-in-Charge. |
| 6 | Programming the main fire alarm panel, detecting the device activating the sounder according to the device, checking the communication between the all the device, fire alarm and main panel using ladder, making main fire alarm to normal display without any fault complete all as specified and directed by the Engineer-in-Charge. |
| 7 | Material & labour wiring for circuit / submain wiring along with earth wire with the cable FR LS, PVC insulated, un sheathed, copper conductor, multistranded, 1100 volts grade single core cables drawn through and including ERW steel conduit and conduit accessories surface / concealed in walls all as specified of size 2 x 1.5 Sq mm + 1 x 1.0 Sq mm for Smoke / fire detectors complete all as specified and directed by the Engineer-in-Charge. |
| 8 | Supply,Installation and testing of fire alaram panel 8 Zone conventional type made out of CRCA sheet with powder coated finish of IP50 red colour suitable for operate on primary power 120-220VAC and stand by power 24 V DC , wall/celing mounted complete all as specified and directed by the Engineer-in-Charge. |
| 9 | M&L for disconnecting/ removal of corroded MS sheet 3mm thick from fire fighting boxes and supply and fabricate 3mm thick CRCA sheet including necessary door hinges, door knobs, door locks, aldrops, over drops, door beading, rubber washers angles iron channel, clamps etc including applying 2 coats of synthetic enamel PO red paint over a coat of zinc chrome primer and fixing of 4mm thick transparent glass on the door as per existing complete all as specified and directed by the Engineer-in-Charge.Note:(a).The rate quoted includes connected welding works/ gas cutting works along with all hardware/ miscellaneous items.(b) Transparent glass sheet and lock & Key arrangement system will be measured separately. |
| 10 | Supply and fixing transparent plain glass 4mm to 5mm thick as per site requirement and existing specification complete all as specified and directed by the Engineer-in-Charge. |
| 11 | Supply and fix lock and key arrangement for fire hydrant chamber as per existing with two nos of keys for each lock complete all as specified and directed by the Engineer-in-Charge. |
| 12 | Supply and fixing rubber hose pipe 30 mtr,20mm inner dia, thermo plastic, working pressure 10kg/sqcm confirming to IS-12585 braided for high pressure complete all as specified and directed by Engr-in-Charge. |
| 13 | Supply and fixing fix gun metal fire hose reel nozzle suitable for 20mm bore hose pipe with handle as per existing complete all as specified and directed by Engr-in-Charge. |
| 14 | Repair of hose pipe reel drum suitable for 30 mtrs, 20 mm dia rubber hose pipe working pressure 10 Kg/Sqcm complete all as specified and directed by Engr-in-Charge. |
| 15 | Supply and fixing ISI marked RRL (Rainforced Rubber Lined) fire hose pipe 15 meter long with male and femail couping gun metal 63mm instantaneous inlet with 15mm bore nozzle short complete all as specified and directed by Engr-in-Charge. |
| 16 | Supply and fixing fix gun metal fire hose reel nozzle suitable for 63mm bore hose pipe with as per existing complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fixing double headed outlet hydrant valve 100mm flanged end having 65mm outlet with lock pin wheel including nut, bolt, washer, gasket complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fixing single headed outlet hydrant valve 100mm flanged end having 65mm outlet with lock pin wheel including nut, bolt, washer, gasket complete all as specified and directed by Engr-in-Charge. |
| 19 | Repair single/double headed outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engr-in-Charge. |
| 20 | Checking of Pre charged Air vessel including servicing, greasing, overhauling, tightening of nut bolts and other spares as required shall be inclusive in the quoted rate. Maintain and ensure for proper working condition and ready for operation and including, complete all as specified and directed by the Engineer-in-Charge. |
| 21 | Supply and fix pressure switch universal type as per existing make and specifications. Complete all as specified and directed by Engr-in-Charge. |
| 22 | Providing & fixing 100mm dia bourden type, stainless steel dial type pressure Gauge (0 - 14 Kg) range, 4\\" BSP bottom entry on pump delivery line complete with ball valve (Glycerin based) complete all as specified and directed by the Engineer-in-Charge. |
| 23 | Supplying and fixing air vessel of continuous welded construction fixed at riser top made of 250 mm dia, 8 mm thick MS sheet, 1000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun Metal wheel valve, with required accessories, pressure gauge and painting with two coats of red oxide and two coat of post office red enamel paint as required, complete all as specified and directed by the Engineer-in-Charge. |
| 24 | Supply and fixing hose reel drum with handle suitable for hold 30 mtr hose pipe complete all as specified and directed by the Engineer-in-Charge. |
| 25 | Supply & fixing ISI marked (IS : 15683) Portable Fire Extinguisher, ABC type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of capacity 6.0 Kg. ABC type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge. |
| 26 | Supply and fixing Carbon-di-oxide fire extinguishers (IS-15222) consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge 4.5 Kg. Light weight squeeze grip CO2 type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge. |
| 27 | Supply & fixing ISI marked (IS : 15683) Portable Fire Extinguisher, AFFF type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of capacity 9.0 Kg. type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge. |
| 28 | Refilling of Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including wall suspension arrangement of capacity 6.0 Kg. ABC type Fire Extinguisher(Dry powder/foam type), complete all as specified and directed by the Engineer-in-Charge. |
| 29 | Refilling Carbon-di-oxide fire extinguishers finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete upto 10Kg. Light weight squeeze grip CO2 type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge. |
| 30 | Supply and fixing battery 7AH, 12 Volts maintenance free as per existing make and specification complete all as specified and directed by the Engineer-in-Charge. |
| 31 | Material and labour for cutting existing MS pipe of bore 80mm to 150mm size and jointing with proper welding and testing of all fittings complete with all welding/threading works and jointing material laid in trenches/ on surface / slopes/ pillars/ culverts includind necessary earth work etc. complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply and fixing in replacement of cast iron sluice valve of size 150 mm (PN 1.6) (ISI Marked) with iron wheel head, both end flanged, stainless steel spindle, non rising type complete with neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply and fixing in replacement of cast iron non return valve, conforming to IS-5312, suitable for 150 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-Charge. |
| 34 | Material and labour of cross arms ,bracings,supports,clamp and back plate fabicated from structural steel sections,including nut and bolts, washers welding bend or cold or hot,drilling holes for bolt in any shape or size indicated or direcected and inclusive of one primer coat,one under coat and one finishing coat all complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply, laying, jointing and testing ERW MS pipe class 'B' pipe 150 mm bore having wall thickness 6mm with permissible tolerance + 10%, pipe shall be confirming to IS-3589, IS marked and steel grade of Fe-410 along with joints (As per site requirements) and taking down of old unserviciable pipe. laid in trenches/along road/on surfaces /slopes /pillars/ culverts/causeways etc. complete all as specified and directed by Engr-in-Charge.Note:- (i) Jointing of pipe line will be done through flanging including nut bolts, washers, flanges etc or circular welding as per site requirment and directed by Engr-in-Charge.(ii) Excavation and earth work will be measured and paid separately. |
| 36 | Description all as per serial item No 34.00 here-in-before, but of size 80 mm bore, complete all as specified and directed by the Engineer-in-Charge. |
| 37 | Supply and fixing in replacement of butterfly valve of size 150 mm (PN 1.6) (ISI Marked) gtype complete with neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-Charge. |
| 38 | Repair to old sluice valve/butter fly valve of sizes 100 to 150mm for check nut, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing complete all as specified and directed by the Engineer-in-Charge. |
| 39 | Repair to old non return valve of sizes 100 to 150mm for check nut, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of non return valve including fixing & testing complete all as specified and directed by the Engineer-in-Charge. |
| 40 | Disconnecting electric connection of motor upto 60 HP removing the unserviciable motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair/winding & re-assembling the same. Complete all as directed by Engineer-in-Charge.Note: (a) Rewinding of motor will be measured and paid separately under relevent item.(b) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed by the Engineer-in-Charge. |
| 41 | Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 10 HP with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time, complete all as specified and directed by the Engineer-in-Charge.Note:- Cost of labour for winding deemed to be included in the rate quoted. Make : Atlas/Devi Dayal or equivalent make approved by GE. |
| 42 | Supply and fixing self lubricated asbestos non metallic and non graphite gland packing of sizes 8 to 12 mm complete all as specified and directed by Engr-in-Charge. |
| 43 | Material and labour for scrapping of existing paint on fire fighting Pipe lines, fittings, motors, pumps, cabinet boxes, valve chamber covers, fire brigades and other miscellaneous items associated to the complete fire fighting system in buildings up to (G+6 floors) and applying two coats red colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. |
| 44 | Material and labour for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in foundation, filling and mass concrete for providing support for Base frame with MS bolts placed in concrete finishing even and fair without using extra cement including demolition complete all as specified and directed by Engr-in-Charge. Note: Location and size of bolts should match as per the previous concrete supporting blocks. |
| 45 | Supply and laying in replacement of XLPE insulated, armored heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 16 sq. mm 4 core power cable fixing on walls with saddles complete all as specified and directed by Engr-in-Charge. |
| 46 | Supply and laying in replacement of XLPE insulated, armored heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 10 sq. mm 3 core power cable fixing on walls with saddles complete all as specified and directed by Engr-in-Charge :- |
| 47 | Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity upto 15 HP complete all as specified and directed by the Engineer-in-Charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A. |
| 48 | Supply only parts in repair for single/multistage pumps of capacity 15 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by the Engineer-in-Charge. |
| 49 | Pump impeller made out of stainless steel or as per existing specification. |
| 50 | Pump shaft stainless steel shaft complete with check nut and keys. |
| 51 | Tyre coupling/star coupling or as per existing at site. |
| 52 | Gland cup. |
| 53 | Shaft sleeves. |
| 54 | Welding remelting and turning finishing cutting of key ways in respect of pump shaft. |
| 55 | Bearing housing. |
| 56 | Pump Casing CI cover suitable for 10HP of different makes |
| 57 | Material & Labour for replacement of fire hydrant tikkri suitable for 63mm fire hydrant valve complete all as specified and directed by the Engineer-in-Charge. |
| 58 | Material & Labour for replacement of fire hydrant rubber washer suitable for 63mm fire hydrant valve complete all as specified and directed by the Engineer-in-Charge. |
| 59 | Opening fire pump control panel, checking serviceability of selector switch, MCB CT, PTs, Buzzer, single phase preventer etc & its connected accessories , repairing of defects, tightening loose contact, internal wiring to make it serviceable condition with all accessories in working condition complete all as specified and directed by the Engineer-in-Charge. |
| 60 | Supply and fixing selector switch as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 61 | Supply and fixing Led Indicators as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 62 | Supply and fixing push buttons as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 63 | Supply and fixing voltmeter as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 64 | Supply and fixing Ampere Meter with CTs as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 65 | Supply and fixing MCB 4pole 6-32A as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 66 | Supply and fixing MCB 1pole 6-32A as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge. |
| 67 | Supply & fixing only GI pipes in repair of bore of pipe 25mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in short length to fix with horse drum with wet riser/walls etc complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply and fixing Pressure release valve as per existing size installed on pressurre vessel complete all as specified and directed by the Engineer-in-Charge. |
| 69 | Supply and installation of fire panel for automation of fire pump made out of MS Sheet and degree of protection IP45 with MCB 4 pole 32 Amps as incomer suitable for 10 HP fire pumps with starter, relays, contactor, single phase preventer, manual mode and auto with voltmeter and ammeter complete all as specified and directed by the Engineer-in-Charge. |
| 70 | Supply and fix in replacement of gun-metal, globe or gate valves, 25 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), including taking down the old existing complete all as specified & directed by Engr-in-Charge. |
| 71 | Supply and fix in repairs 300Watt power supply desigo FACPs and IVC sustem in fire alaram panel complete all as specified and directed by the Engineer-in-Charge.(Make Siemens Model FP2012 -U11) |
| 72 | Refilling Carbon-di-oxide fire extinguishers of trolley/ wheel mounted finished externally with red enamel paint complete of cap above 10Kg and upto 20 Kg with hydro pressure test complete all as specified and directed by the Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |