| 1 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed. |
| 2 | M&L Dubbing out average 10 mm thick on irregular face of walls in cement plaster 1:4 for RCC Chajjas, balconies complete all as specified and directed. |
| 3 | M&L for Rendering 15 mm thick in cement mortar 1:4 , mixed with water proofing compound, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement (WPC to be measured separately) complete all as specified. |
| 4 | Supply only liquid Water proofing compound complete. |
| 5 | M&L for Rendering 15 mm thick in cement mortar 1:6, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement complete all as specified. |
| 6 | M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces in ceiling (facia/ceiling/edging of chajjas and roof projection) including finishing even and smooth without using extra cement complete all as specified. |
| 7 | M&L guniting for shortcrete 1 :2 (CM) mixed with epoxy resin and hardner (manufactured by FOSROC/MC BAUCHEMIC /CICO/PIDILITE)@ 2% by weight of cement in equal proportion using short crete pumps and allied equipment,in thickness 30-40 mm all as per manufactureres instruction.(Upto 12 mtr height) including necessary form work and chiping/taking down loose concrete to make a good shape all as specified and directed. |
| 8 | S&F welded steel wire fabric n. exc. 4 kg per sqm, fixed complete to wood or steel members complete all as specified. |
| 9 | M&L for preparation of new plastered surfaces of walls and applying two coat of interior emulsion paint by using roller to wall surfaces over and including a coat of acrylic wall care putty of 0.5mm to 1mm thick ( in 1/2 coats as required) complete all as specified. |
| 10 | M&L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper including 0.5 to 1 mm thick white wall care putty (in 1/2 coats as required) complete all as specified and directed. |
| 11 | M&L for preparation of new plastered surfaces on walls/ceiling and applying three coat of white wash complete all as specified and directed. |
| 12 | M&L for preparation of new plastered surfaces to external walls/RCC surfaces/soffits of chajjas/roof projections /cantilevers /balcony etc surfaces and applying two coats of exterior emulsion paint by using roller over and including wall care putty of 0.5mm to 1mm thick ( in 1/2 coats as required) complete all as specified. |
| 13 | M&L for prepartion of new plastered surfaces of walls and applying two coat of cement based paint on external walls complete all as specified and directed. |
| 14 | Demolition of Concrete is reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for purlins, runners etc |
| 16 | Dismantling timber scantling 40Sqcm and over in section in any position in unframed work as in rafters, purlins etcNote: The rates includes rates of scaffolding to work at a height of double story . Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 17 | S&F mild steel work as in square pipe/tubular/angle as in post, rafter, purlins, including special shaped washer etc, complete using ERW or induction butt welded tubes including distances pieces, base plates, nut bolts etc including complete all as specified and directed. |
| 18 | M&L for preparation of new surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 19 | Dismantling of brick or terracing tiles of single layers on roofs incl cleaning of bricks/tiles and removal of unusable bricks/tiles and removal from site, complete all as specified and as directed |
| 20 | Removing of Mud in roofs, any thickness, including plastering and leeping (whether full thicknes removed or only a part thereof) |
| 21 | Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified. |
| 22 | M&L for cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in padding over roof, minimum thickness at khurra as 25 mm to maintain a slop of 1:100 complete all as specified and directed. |
| 23 | M&L for 10 mm thick rendering on top of roof in CM 1:3 incl mixed with WPC(WPC shall be paid separately) |
| 24 | M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc. complete all as specified. |
| 25 | M&L for APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqm black finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm torching over laps with a propane or a butan gas torch with a over lap of 75 mm at the side and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminious primer all as per manufacturers instructions incl preparation of surface complete all as specified and directed. |
| 26 | S&F laying factory made, un-reinforced precast cement concrete tiles of size 250mm x 250mmx 22mm, machine pressed, as on roof surface, confirming to IS : 1237-1980, laid over and including 15mm thick screed bed in Cm 1:4, set jointed and pointed with grey cement slurry complete all as specified and directed. |
| 27 | Dismantling of water tanks exc 250 & n exc 500 ltr capacity & removing to store all as directed by the Engr-in-Charge. |
| 28 | S&F Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position, connecting to inlet or outlet and washout complete all as specified and directed |
| 29 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. |
| 30 | S & F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 31 | Taking up or down existing steel tubing and connections, 20mm bore complete all as specified. |
| 32 | S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified. |
| 33 | Dismantling Asbestos Cement (corrugated, semi-corrugated,etc.) sheet in roof coverings complete all as specified and directed.Note : The rates includes rates of scaffolding to work at a height of up to 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 34 | S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws,complete all as sepcified and directed.Note : The rates includes rates of scaffolding to work at a height of up to 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 35 | S&F pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete, all as sepcified and directed.Note : The rates includes rates of scaffolding to work at a height of up to 15m hangars. Contractor shall take all necessary safety precautions alongwith insurance cover to his workmen before commencement of work. Unit rates quoted shall deemed to be inclusive of all such factors and nothing extra including compensation to workmen in any manner is payable on this account. |
| 36 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 37 | S&F 110 mm bore PVC (SWR ) PIPE in any length fixed to walls and floor with and including rubber ring joint and MS clamps made of FI 40x3mm and fixed complete all as specified and directed |
| 38 | M&L PVC(SWR) bends 110 mm(any radius), diminishing pieces or tapers(larger bore measured) |
| 39 | M&L Cement plastering 20mm thick in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on surface of floor etc finished even and smooth without using extra cement and making square of size 30 cm x 30 cm by diamond cutter complete all as specified and directed.Note : WPCshall be measured and paid separately. |
| 40 | Surface preparation & Cleaning the surface of roof top made free of dirt, foregin particles laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expantion contraction. Cutting the grooves with suitable cutter machine in 'V' groove filled with Repair mortar/Mircroconcrete/General purpose grout as recommended propertionaly as per recommendation of manufacturer making of Gollas at all the corners with Polymer modified mortar (1:4) Cement :Sand with 3.5% Acylic of Cement weight Supplying and applying High build waterproofing coating based on pure hydrophobic polyurethane cold applied of spray /brush applied membrane with and elongation of 280% and tensile strength of 2.7 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, hardness (shore A scale) 80, solar reflectance of 84% as per A ASTM E903-96, SRI of 106, capilary absorption of 0.01kg/m2 h0.5 as per EN 1062-3, adhesion must be of ˃ 2.0 N/mm2 as per EN 1542, artificial weathering must be passed as per EN 1062-11 temprature resistance must be in between -300C to +900C, no leakage upto 5 bars of water pressure as per DIN 1048 mm min 88% solid content. The system includes final top coat of high build waterproofing coating based on pure hydrophobic polyurethane white in color application in 2 coats with a total min consumption of 1.5 Kg per SQM in ratio 60% 40% in both coats respectively over a coat of epoxy primer 1:1:2 (Resin:hardner:water) with a min consumption of 0.2 Kg per SQM. Application should be given by company for the product on company letterhead (Note : Resin is one of the component of PU Magnum primer which is two components water based epoxy system, it is classified as SR-B2 0 according to EN 13813 having properties like color of pale yellow viscocity 900mPas, density 1.15kg/lt and adhesion of ˃3N/mm2. Hardener is one of the component of PU Magnum Primer, which is a two components water based epoxy system, it is classified as SR-B2, 0 according to EN 13813 having properties like color of pale yellow, viscocity 37000mPa's, density 1.08kg/l and adhesion of >3N/mm2. Make: Asian paints, Dr fixit, Berger Paints , sika, Fosroc |
| 41 | Demolition of Brick work or stone/boulder masonry, build in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 42 | M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed. |
| 43 | Raking out joints/pointing to brick work or brick tiles, laid flat, in floors, surface channels, roofs, etc. and M& L for Flush pointing in cement mortar 1:3, mixing of liquid water proofing compound as per manufacturer's instructions to bricks laid flat or brick tiles in pavings, aprons etc, complete all as specified and directed. Please Enable Macros to View BoQ information |