| 1 | M&L for Surface dressing n exc 15 cm deep and getting out in soft / loose Soil complete all as specified and directed. |
| 2 | M & L for Excavating over areas, n exc 1.5 m deep and getting out in any type of Soil complete all as specified and directed. |
| 3 | M & L for Excavating over areas, exc 1.5 m deep beyond the first 1.5 m and getting out in any type of soil complete all as specified and directed. |
| 4 | Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out in any type of soil, returning, filling and incl ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 5 | M&L Cement concrete in foundations, filling and mass concrete type D-2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed. |
| 6 | M&L Reinforced cement concrete (Design mix M-30 grade using 20mm graded stone aggregate) in foundations, footings, plinth beams, bases for columns, etc and mass concrete complete all as specified and directed. |
| 7 | M&L Reinforced cement concrete (Design mix M-30 grade using 20mm graded stone aggregate) above top of footings including attached pilasters and buttresses complete all as specified and directed. |
| 8 | M&L Reinforced cement concrete (Design mix M-30 grade using 20mm graded stone aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 9 | M&L Reinforced cement concrete (Design mix M-30 grade using 20mm graded stone aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 10 | M&L Reinforced cement concrete (Design mix M-30 grade using 20mm graded stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 11 | M&L Returning, filling , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 12 | M&L Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level 1.5m above the starting point as complete all as specified and directed. |
| 13 | M&L for use & waste of Formwork flat or curved to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter complete all as specified and directed. |
| 14 | M&L for use & waste of Formwork flat or curved to to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 15 | M&L for use & waste of Formwork flat or curved to sides and soffits offloor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified. |
| 16 | M&L for use & waste of Formwork flat or curved to Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 17 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L for Mild steel TMT bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | M&L pre-cast cement concrete masonary in PCC 1:3:6 type C1 using 20mm graded stone aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete all as specified and directed. |
| 20 | M&L for 40mm thick Damp proof course in cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate to horizontal or vertical surface including necessary formwork complete all as specified and directed. |
| 21 | M&L for 15mm thick rendering in two layers of 10mm thick backing coat inCM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces/ RCC roof surface complete all as specified and directed (water proofing compound will be measured and paid seperately). |
| 22 | Supply only Liquid water proofing compound |
| 23 | M&L for 10mm thick rendering in CM 1:6 on all internal wall surfaces complete all as specified and directed. |
| 24 | M&L for rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like complete all as specified and directed. |
| 25 | M&L for Filling sand under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 26 | M&L for Hardcore of gauge n exc. 63mm with broken stone boulder deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 27 | M&L for 100mm thick PCC 1:4:8 Type D-2 using 40 mm graded stone aggregate as in sub base for floors complete all as specified and directed. |
| 28 | M&L for 40mm thick Cement concrete type B-0,1:2:4 (12.5mm graded stone aggregate) as in plinth protection and finished the surface even smooth using extra cement complete all as specified and directed. |
| 29 | M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete in floors etc, over screed bed in cement mortar 1:4, 20 mm thick, all as specified complete all as specified and directed. |
| 30 | M&L for Machine cut kota stone slab flooring 18-20mm thick over cement on vertical surfaces such as skirting including 10 mm thick backing coat in CM 1:3 complete all as specified and directed. |
| 31 | Material & Labour for applying to finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 32 | M & L for applying three coats of white wash on newly plastered surfaces of wall including preparation of surfaces even and smooth complete all as specificed and as directed. |
| 33 | M & L for applying three coats of white wash on newly plastered surfaces on ceiling chajja beams etc including preparation of surfaces even and smooth complete all as specificed and as directed. |
| 34 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specificed and as directed . |
| 35 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings complete all as specificed and as directed . |
| 36 | S&F 150mm long extruded aluminium alloy anodised handles fabricated type complete all as specificed and as directed . |
| 37 | S& F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet cast or extruded sections and fixing bolt or cast aluminium alloy complete all as specificed and as directed . |
| 38 | S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete all as specificed and as directed . |
| 39 | Supply only 12 mm thick Prelaminatd particle board, exterior grade, prelaminated exterior grade on both sides with decorative choice lamination and fixed to aluminium frames complete all as specified and as directed . |
| 40 | S&F in repair Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 100mm Size |
| 41 | Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge. |
| 42 | Supply only aluminium alloy wire mesh 0.45 nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples complete all as directed by Engineer-in-Charge. |
| 43 | Supply only Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type c-21 75mm Size complete all as specificed and as directed . |
| 44 | Supply only adjustable aluminium powder coated window handle with hook of size 125mm complete all as specified and as directed. |
| 45 | S&F anodised aluminium grill (anodised transparent or dyed to required shad according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to poper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete all as specified and as directed. |
| 46 | S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachemtns complete all as specified and as directed. |
| 47 | S & F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed. |
| 48 | M&L for preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise complete all as specified and as directed. |
| 49 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 50 | S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all complete all as specified and as directed. |
| 51 | M&L Surface dressing n exc 15 cm deep and getting out hard/Dense Soil complete all as specified and as directed. |
| 52 | M&L Hardcore of gauge n exc. 63mm with broken stone boulders deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface complete all as specified and as directed |
| 53 | M&L for glazed, polished Chequered cement concrete tiles 300mm x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry, including screed bedding layer in cement mortar 1:6, 20mm thick in flooring complete all as specified and as directed. |
| 54 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessarystainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 55 | M & L for Screed bed or bedding layer of mortar 20 mm thick in Cement mortor 1:4 for laying floor finishes complete all as specified and as directed |
| 56 | M & L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 57 | M & L for Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in Cm 1:3 all as specified and as directed by Engg-in-Charge |
| 58 | M & L for applying two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of wall including preperation of surfaces complete all as specificed and as directed |
| 59 | M & L for applying two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of Ceilings, soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like including preperation of surfaces complete all as specificed and as directed |
| 60 | S&F Aluminium anodised door / window / ventilator / partition frames including shutters (Two no glazed and gauzed) side hung type with out sash bar, standard aluminium grill, using standerd section incl necessary joining cleats glazing clips, rubber packing, anodised Aluminium snap beading screws, handle and locking arragment etc completeNote : Glass & fly proof mesh measured and paid seperately as supply only. & Hardwares shall be measured and paid separetely |
| 61 | S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing. |
| 62 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC `C' channel having at PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 63 | S&F 100mm long extruded aluminium alloy anodised handles fabricated type complete all as specified and as directed |
| 64 | S&F Aluminium anodised barrel tower bolt of extruded section of size 100mm long complete all as specified and as directed |
| 65 | S&F Aluminum anodised butt hingess 75mm long extruded alluminum, alloy with galvanised mild steel hinge pin, type C-22 |
| 66 | S&F vitreous china water closet, pedestal type, white including flush pipe, seat cover etc, including connection to drain (or out going pipe) and to flushing pipe anti syphonage pipes etc complete all as specified and as directed by Engineer-in-Charge |
| 67 | S & F vitreous China wash hand basin,'OVAL TYPE' 550 mm including with single tap hole CP pillar cock of 15 mm dia brass CP chain and rubber plug , waste pipe and PVC connection complete all as specified and as directed. |
| 68 | S & F for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe)complete all as specified and as directed |
| 69 | S&F PVC low level flushing cistern,10 litres capacity, including PVC flush pipe of required length, 15 mm bore ball valve and PVC connection 300 mm and other accessories, complete all as specified and directed. |
| 70 | S&F 110 mm dia PVC (SWR) Pipe single socketed in any length with rubber ring joint laid in trenches/fixed on floor/walls including jointing with solvent cement all as specified and directed by Engineer -In-Charge. |
| 71 | M&L for UPVC 75 mm dia Nahani trap/floor trap with PVC grating complete all as specified and directed. |
| 72 | S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and as directed. |
| 73 | S & F for 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 74 | S & F for Soap dish, vitreous China white, approximate size 160x 160x90mm embedded in the wall complete all as specified and as directed |
| 75 | S & F for 20mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and as directed |
| 76 | S & F for 15mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe conceled complete all as specified and as directed |
| 77 | S & F 15 mm bore pillar tap cast copper alloy with capstan heads chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes in repairs complete all as specified and as directed |
| 78 | S & F 15 mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed |
| 79 | S & F 15 mm bore fancy type, chromium plated with long shank and cup (concealed type) Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed |
| 80 | S & F in PVC waste pipe, 32mm dia, for WHB, complete all as specified and as directed by Engineer-in-Charge. |
| 81 | S & F inPVC waste pipe, 32mm dia for urinal, complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S & F in PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed |
| 83 | S&F in repairs 2 in 1 bib cock but fancy type chromium plated 15mm dia bore pipe complete all as specified and as directed. |
| 84 | S&F chromium plated hand shower (health faucet) 8mm bore 1.2 meter long fexible tube with wall hook,complete all as specified and as directed by Engineer-in-Charge |
| 85 | S & F for steel work in tubular truss including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed. |
| 86 | S&F Vitreous china squatting plate urinal, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed |
| 87 | M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc for One Exhaust fan/ light point controlled by one switch all as specified and as directed |
| 88 | M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc for One fan point controlled by one switch and one regulator all as specified and as directed |
| 89 | M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc One 3 pin switch socket outlet point 5 amps on independent board all as specified and as directed |
| 90 | All as per item No 86 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. |
| 91 | Supply and fix switch piano flush button single pole oneway 5 amp complete all as specified and as directed. |
| 92 | Supply and fix switch socket combination 3 & 2 pin (multi pin) 5 amp flush type complete all as specified and as directed. |
| 93 | Supply and fix switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed. |
| 94 | Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge |
| 95 | Supply and fix fan steped regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge |
| 96 | Supply and fix ceiling fan suitable for working on AC 230 volts, 50 Hz,1200 mm sweep 5 star rating with down rod and canopy colour of milky white including suitable fan hook anchor flashner for fixing of fan on ceiling complete all as specified and as directed. |
| 97 | Supply and fix aluminium housing LED batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core sheathed cable from fitting to ceiling rose complete all as specified and as directed |
| 98 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant complete with IP 65/66 protection complete all as specified and directed. |
| 99 | Supply and fix exhaust fan steel body suitable for on working of AC 230 V ,50 Hz 300 mm sweep upto 1400 RPM,with heavy duty motor ,incl louvers complete all as specified and as directed |
| 100 | Supply and fix sheet metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs complete all as as specified and as directed by Engineer-in-Charge |
| 101 | Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, B series complete all as specified and as directed. |
| 102 | Supply and fix MCB SPN 240 volts, 5 to 32 Amps, complete all as specified and as directed. |
| 103 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I |
| 104 | Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 Core 10 sq mm. |
| 105 | Excavating in trenches, in Soft/loose Soil n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out |
| 106 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil. |
| 107 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point. |
| 108 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked complete all as specified and as directed |
| 109 | S&F 50 mm bore GI tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed |
| 110 | Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 using 40mm graded stone aggregate to match the existing surfaces of the road complete all as specified and as directed by Engineer in charge. Please Enable Macros to View BoQ information |