| 1 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. |
| 2 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 3 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and as directed. Note: To be executed for provision of ridges and hips. |
| 4 | S&F 1mm thick and 125mm dia mild steel sheet eaves gutter half round with rounded edges, galvanized class 3, coloured preprinted matching the colour to extra roof sheet with necessary brackets complete all as specified and as directed. |
| 5 | M&L for mild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 7 | Dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed. |
| 8 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (GdeE- 250) quality A complete all as specified and as directed. |
| 9 | S&F rolled mild steel plates (plain or chequered) square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment GDE Fe410-W (GdeE- 250) quality 'A' complete all as specified and as directed. |
| 10 | S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 11 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 12 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 13 | S&F 4mm thick Non asbestos fiber cement building boards (E-board) inserted to Aluminium framework using screws with powder coated Anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm using Main/Cross Bulbed tees - Tapered head (Web : 25mm Flange : 38mm) of weight not less than 0.249 kg/m and Equal angle of size 25mm of weight and not less than 0.196 kg/m, for false ceiling, flat or sloping fixed or laid with hangers 6 mm dia GI (n-exc 1200 mm in length apart) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long including dismantling of old ceiling of any description complete all as specified and as directed. |
| 14 | Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 15 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 16 | Demolition of plain cement concrete in ground floors and pavings exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 17 | M&L for hard core with broken bricks of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 18 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 19 | M & L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 20 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 21 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 22 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 23 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 24 | M&L for 15mm thick rendering in cement mortar (1:4) fair faces of brick or concrete wall surfaces, mixed with highly stretchable, durable and hydrophobic, Elastomeric Hydrophobic Powder/admixture (EHP) powder @ 1% of cement content, finished even and smooth without using extra cement complete all as specified and as directed. Note : Elastomeric Hydrophobic Powder/admixture (EHP) shall be measured and paid as Supply only in respective item. |
| 25 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces , finished the surface even and smooth without using extra cement and including highly stretchable, durable and hydrophobic, Elastomeric Hydrophobic Powder/admixture (EHP) powder @ 1% of cement content including liquid Water proofing compound @ 200ml per 50kgs of cement or as per manufacturers instruction complete all as specified and as directed.Note : WPC and Elastomeric Hydrophobic Powder/admixture (EHP) shall be measured and paid as Supply only in respective item. |
| 26 | Supply only Elastomeric Hydrophobic Powder/admixture (EHP) powder for cement plaster and concrete complete all as specified and directed. |
| 27 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 28 | Complete removal of existing treatment & levelling of wall/ceiling surface using MECHANICAL / ELECTRICAL OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface complete all as specified and as directed. |
| 29 | M&L for preparation of old/new plastered surfaces and applying a coat of 1mm (average thick) white putty of new/old plaster, and applying two or more coats Distempering 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ltrs of approved manufacturer, of required shade and colour complete as per manufacturer's specification complete all as specified and directed. |
| 30 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces using Airless Paint Primer Sprayer using smart technique, on newly plastered surface of wall, cornices complete all as specified and as directed . |
| 31 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and as directed.Note : Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces |
| 32 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. Note: Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces. |
| 33 | S & F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 34 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. Please Enable Macros to View BoQ information |
| 35 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. Please Enable Macros to View BoQ information |