| 1 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr. : All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 4 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 5 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 7 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : |
| 8 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 9 | Columns, pillars, posts and struts etc. |
| 10 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 11 | Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 12 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 13 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boards M20 grade Nominal Mix / Design Mix |
| 14 | Add extra for providing richer mixes respectively at all floor levels |
| 15 | Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. |
| 16 | Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 insuperstructure above plinth level upto floor V level in. |
| 17 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 18 | Half Brick work with mechanised autoclaved flyash lime bricksconforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in |
| 19 | Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 20 | Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry . |
| 21 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: |
| 22 | Cement Mortar 1:6 ( 1-Cement : 6-Sand). Upto plinth |
| 23 | Random rubble dry stone Kharanja under floor. |
| 24 | P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. |
| 25 | size 600 mm X 600 mm |
| 26 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 27 | Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour |
| 28 | Above 3601 Cm2 Slabs |
| 29 | Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 30 | Granite/Kota Stone Work |
| 31 | Full Edge moulding |
| 32 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete |
| 33 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 34 | Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles. |
| 35 | Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size. |
| 36 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 37 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). |
| 38 | For fixed portion |
| 39 | Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 40 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). |
| 41 | Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 42 | Extra for shutters of sliding aluminum windows |
| 43 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) |
| 44 | With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 45 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : |
| 46 | 35 mm thick . |
| 47 | Commercial veneer both side |
| 48 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 49 | Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : |
| 50 | Profile B |
| 51 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. |
| 52 | Providing and fixing to existing door frames. |
| 53 | 30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter). |
| 54 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finish : |
| 55 | 20 mm thick |
| 56 | 12mm thick. |
| 57 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 58 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete (New plastered surface three or more coats) |
| 59 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 60 | Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 61 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision |
| 62 | Trowel Finish av. thickness 1500 to 2000 microns. |
| 63 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 64 | Two or more coats on new work |
| 65 | Grading roof for water proofing treatment with water proffing compound |
| 66 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 67 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 68 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 69 | 1: 3: 6 or richer mix. |
| 70 | Providing, arranging and erecting 50mm dia M.S. pipe cup lock shuttering arrangement above the ground level upto the height given below. The grid arrangement of cup lock system should have 2.50 meter to 3.00 meter long coupling pipes and 0.90mt long lacer pipe (Horizontal bracing pipes) reconnected in both ways so as to make a square grid of size 0.90x0.90 meter in plan. The Horizontal bracing and lacer pipes should have a maximum spacing of 1.50 meter c/c both ways. The bottom of the coupling pipe must rest over a firm support at ground. The shuttering plates of 900mmx600mm size duly braced by angle supports and should rest over 50mmx50mm size wooden logs supported by 75x40x6mm size channels and |
| 71 | U-Jacks made of M.S.25mm dia steel bars with adjustable thread and lock arrangement placed at a spacing of 0.60 meter c/c. The whole arrangement should be duly shored from ground by U-Jacks and lacer pipes to prevent any lateral movement during casting of slabs. Additional support as per direction of engineer in charge are also to by provided wherever felt necessary. The work would include transportation of material erecting the whole grid structure, bracing both way, shoring, leveling of shuttering and removal of form work complete as per direction of Engineer in charge for all the floors upto the height of:- |
| 72 | Upto 9.14 meter height |
| 73 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 74 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 75 | NBSR Providing & Fixing 3D lit Acrylic Letters of size 24\\" made of 4mm thickness 030 white colour A cast acrylic in front, sides raised finished in 1mm white color precasted selenium sheet cut on MS laser machine as per size having arial font, 40mm depth made with white pre-coated selenium on sides. Back cover with 8mm WPC \ 3mm ACP Sheet. Lighting - 1-1.5 mm wire for connection, Hi-Lite white colour Led Modules, Water proof, Power supply Hi sign/Hi Lite complete as per direction by Engineer in charge of District Hospital Dausa |
| 76 | NBSR Provding & Fising 4mm thick ACP sheet base furnished for fixing letters including base MS frame 1.5\\"x1.5\\" size (@2kg/Sqft) as per design. MS work will be painted with approved enamel paint & red oxide including fixing of this frame with existing structure including all cost of fastners/fixtures etc as per direction of Engineer In charge. |
| 77 | P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 78 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 79 | 75 mm dia |
| 80 | 110 mm dia |
| 81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 82 | 20mm nominal outer dia pipes |
| 83 | 25mm nominal outer dia pipes |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). |
| 85 | 20mm nominal outer dia pipes |
| 86 | 25mm nominal outer dia pipes |
| 87 | P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : WVC for symphonic EWC. |
| 88 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall : |
| 89 | Size 630 mm x 500 mm dia for counter top |
| 90 | P&F looking mirrors with PVC frame of approved (atul/equivalent) Size 500x400mm |
| 91 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 92 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. |
| 93 | C.P. Inlet connection 15 mm Brass (IS:8931 marked). |
| 94 | ---do--- with 37 cm long pipe and nut. |
| 95 | P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 25 mm nominal bore. |
| 96 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design : 500 litres capacity. |
| 97 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 X 450 mm depth upto 0.5 M Cement cover with frame. |
| 98 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 110 mm dia |
| 99 | Coupler (socket) |
| 100 | Reducer 110 X 75 mm |
| 101 | Plain Tee |
| 102 | Vent Cowel |
| 103 | Door Tee |
| 104 | Bend 45 |
| 105 | Bend 87.5 |
| 106 | Gully trap |
| 107 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of EI |
| 108 | Swan neck pillar cock 15 mm nominal size |
| 109 | Long body Bib Cock 15 mm nominal size |
| 110 | 600 mm long towel rail |
| 111 | Soap dish |
| 112 | Paper holder |
| 113 | P & F Grating of approved quality/make: C.P. brass with frame (Heavy) & superior quality size 125mm dia. |
| 114 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make (Atul, Modi Guard, Saint Gobin or equivalent) complete with 6mm thick commercial ply base fixed to wooden screws & washers. Other sizes |
| 115 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 116 | 75 mm dia |
| 117 | 110 mm dia |
| 118 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 119 | Coupler |
| 120 | 75mm dia |
| 121 | 110mm dia |
| 122 | Bend 87.5 Dg. |
| 123 | 75mm dia |
| 124 | 110mm dia |
| 125 | Bend 45 Dg. |
| 126 | 75mm dia |
| 127 | 110mm dia |
| 128 | Single Tee |
| 129 | 75mm dia |
| 130 | 110mm dia |
| 131 | Gully Trap |
| 132 | 110mm dia |
| 133 | Nahni Trap without Jali 4” |
| 134 | 110mm dia |
| 135 | P & F S.W. Master Trap (Inter-cepting) `A` grade (I.S.: 651 marked) of approved quality/make |
| 136 | 150 mm dia Please Enable Macros to View BoQ information |