| 1 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified directed. |
| 2 | Material & Labour for 25 mm thick PCC 1:2:4 type B 0 (using 12.5 mm graded crushed stone aggregate) as in sub base of flooring etc. complete all as specified directed. |
| 3 | Material & Labour for coloured non skid/matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular), area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed. |
| 4 | Ditto all as per item No 3 above but as in dado, riser & skirting over & incl 10mm thick rendering in CM 1:4 complete all as specified directed. |
| 5 | Material & Labour for Glazed ceramic coloured tiles in vertical surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, & incl 10mm thick rendering in cement mortar 1:3 complete all as specified directed. |
| 6 | Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints , hacking for key, scrubbing down with water etc complete all as specified & directed. |
| 7 | Material & Labour for rendering 5mm thick cement plaster in cement mortar (1:3) on concrete surfaces as in ceiling, finished even and smooth without using extra cement complete all as specified directeded. |
| 8 | Material & Labour for rendering 12mm thick cement plaster in cement mortar (1:6) on concrete surfaces as in wall , finished even and smooth without extra cement complete all as specified. |
| 9 | Material & Labour 15 mm thick cement plaster in cement mortar 1:4 mixed with liquid water proofing compound @ of 3% as on brick or concrete surface of walls finished surface fair and even without using extra cement complete all as specified and directed. Note : Supply only water proofing liquid shall be measured and paid separately. |
| 10 | Supply only liquid water proofing compound to mixed with cement mortar etc, complete all as specified directed. |
| 11 | Material & Labour preparing New plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces complete all as specified directed. |
| 12 | Material & Labour preparing old plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces complete all as specified directed. |
| 13 | Material & Labour preparing New plastered surfaces on walls and applying one coat of primer paint, two coats of oil bound distemper including 1 mm wall care putty complete all as specified directed. |
| 14 | Material & Labour preparing Old plastered surfaces comlete removal of existing treatment on walls and applying one coat of primer paint, two coats of oil bound distemper including preparation with wall care putty complete all as specified directed. |
| 15 | Material & Labour for preparation of new plastered ceiling surfaces and applying two coats of white wash complete all as specified and directed. |
| 16 | Material & Labour for preparation of Old plastered surfaces complete removal of existing treatment on Ceiling and applying two coats of white wash complete all as specified and directed by EIC. |
| 17 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc, complete all as specified and directed. |
| 18 | Material & Labour Brick work with sub class \\"B\\" bricks, straight or curved on plan exc 6 m mean radius , built in cement mortar 1:6 complete all as specified and directed . |
| 19 | Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and directed. |
| 20 | Demolition of Mud in roof any thick ness including plastering and leeping (Whether full thickness removed or only a part therof), complete all as specified directed. |
| 21 | Material & Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) mixed with water proofing liquid as in padding of required thickness, in roof kerb to amintain slop correction of the depressed undraution portion complete all as specified and as directed |
| 22 | Material & Labour for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric( weight not less than 150 gms/sqm) laid on primed surface by forced application with and including approved bitumen primer as per manufacturer's instructuctions including cleaning the surfaces including one coat of bitumen primer before laying of APP membrane sheet complete all as specified and as directed.Note: Sheet shall be five layered prefabricated Atactic Polypropyleen Polymer (APP) modified 3 mm thick membrane (weighing not less than 3 kg/sqm) reinforced with 150 gsm polyester non- woven fabric. Concrete of roof surface shall be scratched with scratched tool before finishing roof surface when the concrete surface is still green,10mm thick 1:4 cement plaster shall be laid .The roof surfaces shall be throughly wire brushed, washed, dried up and cleaned to all foreign matter and dust prior to the appliction of primer. On the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm shall be applied. APP membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry . Laying off APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100mm on longitudinal direction and 150 mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by heating the overlaps with butane torch. the treatment shall be done by the approved authorised applicatiors. |
| 23 | Material & Labour for 40mm thick brick tiles laid on concrete roof padding over and including 15 mm thick cement screed bed in cement mortar (1:6) using grey cement, jointed and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all specified and as directed. |
| 24 | Material & Labour for 40mm thick brick tiles (EXCEPT TILES) laid on concrete roof padding over and including 15 mm thick cement screed bed in cement mortar (1:6) using grey cement, jointed and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all specified and as directed. |
| 25 | Supply & fixing in repair 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, incl hacking out complete all as specified directed by EIC. |
| 26 | Material and labour for box type steel window, ERW hollow p-section size 60 mm x 25 mm, double rebated ERW section of 1.25mm thick, comprising of glazed skelton & gauzed shutter of ERW tube P- section size 50mm x 20mm with one No openable leaf for each shutter consisting of two Nos Sashbar of T-section 20 x 3mm welded to frame with one No verticle mullion of ERW box type T section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast and gaurd bars etc as given below all as shown on drg No CEJZ/TD-1020/08 SH1/3 to 3/3 dated 01 May 2008 complete all as specified and directed as follows:(a) Hold fast 150mm long of MS flat 12mm x 3mm - 4 Nos per window(b) Handle of Z section 20mm x 25mm, 100mm long - 01 nos per leaf(c) MS tower bolt 150mm long - 02 Nos per leaf(d) Z section stopper 20mm x 25mm, 100mm long -01 No per leaf(e) Cleat 55mm long of hollow square 15mm, 0.63mm thick - 01 Nos per leaf(f) MS pintol hinges size 75mm x 12mm -02 Nos per leaf(g) MS guard bar 10mm square bars @ 10cm c/c fixed horizontly(h) 3mm thick clear glass sheet 3 Nos per leaf glazing with oil putty.(j) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in each leaf.Note:- Including taking down old steel/wooden window including hold fast PCC 1:2:4 type B0 (four No's for each window) & around required plaster in CM 1:4 and match with existing finish complete all as specified and directed. Painting shall be measured and paid separately. |
| 27 | Material & Labour two coats of synthetic enamel painting on wooden surfaces of any description over 10 cm in width or girth not otherwise described above pink primer including prepration of previously untreated surfaces complete all as specified directed |
| 28 | Material & Labour one coats of synthetic enamel painting on Old wooden surfaces of any description over 10 cm in width or girth not otherwise described above including prepration of previously untreated surfaces complete all as specified directed |
| 29 | Material & Labour for preparation of New steel surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified directed. |
| 30 | Material & Labour for preparation of Old steel surface of any description not other wise described, over 10cm width or girth and applying one coats of synthetic enamel paint, complete all as specified directed. |
| 31 | Dismantling of wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, frame etc. complete all as specified directed. |
| 32 | M&L 12mm thick fully perforated micro tegular /10mm thick square edged GRG flase ceiling tiles for Providing & fixing false ceiling at all heights and wall paneling with GRG (Glass fiber reinforced gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS-8225:1987, noncombustible as per DS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm on both sides) comprising of main-T runners of size 15x32mm of length 3000mm, cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm), 50mm long, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing all as specified directed. |
| 33 | Supply and fixing 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing as per site complete all as specified directed. |
| 34 | Supply and fixing soild PVC wall lining consiting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as and fixing at site etc complete all as specified and directed |
| 35 | Material & Labour for chipping the spalled and old concrete removing loosely adhering particles using wire brushes and make the structure for application of micro concrete complete compltying with standard specification incl lead and lift for an avreage thickness of 25 mm incl desposal of debries to within site low laying area out side of MoD land as directed by Engr -in charge, Cleaning of rusted bar should be done properly such that no rust shall be preenst after removal of rust from bar after this epoxing existing reinfocement bars with applying protective zinc primer using fosroc Nitoprime Zincrich or Dr Fixit primer or equivalent on bars of dry thickness 40 micron (wet thickness 130 micro ) with approx coverage of 7.4 Sq/Litrs before micro conceting with and including necessay formwork complete all as specified & dirceted Upto the bldg height 7.5 mtre. |
| 36 | Material & Labour in repairs for Stocking sufficient quantity of micro concrete material comprising 10mm down graded aggrgate chips pouring in continus operationwith grout//concrete mixer of low speed heavy duty dram fitted suitable shall be kept ready and chips slowly mixed in the dram throughly in a force action with mechanical. The Mixed materall shall be placed immediatly in to the postion formwork contiuausaly with out any time gap complete for an average thickness 25mm including finising the exposed surface to an even and smotth surface completely as specified and directed. The micro concrete shall be Sika conrete 114 AE or Dr Fixit MIcro concrete or equivalent of manufacturers fosroc concete or Bouchemie with and including necessay formfow complete all as specified & dircetd. |
| 37 | Supply & fixing fixed in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples , complete all as specified directed. Please Enable Macros to View BoQ information |
| 38 | Supply & fixing fixed in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples , complete all as specified directed. Please Enable Macros to View BoQ information |