| 1 | M&L for Preparation of old decorated surfaces of walls incl washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of distempering with acrylic distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 2 | M&L for Preparation of old/new decorated surfaces of walls incl washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of distempering with acrylic distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 3 | M&L for Preparation of old/new decorated surfaces of ceiling and applying one coat of distempering with acrylic distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 4 | M&L for Preparation of old/new painted steel surface of any description, over 10cm in width or girth not other wise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 5 | M&L for preparation of old/new painted surfaces of wood and wood based surfaces of any description over 10 cm girth or width, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 6 | M&L for Preparation of old/new decorated surfaces incl washing, rubbing down and stopping of distempered and painted surfaces a coat of water proof cement base paint on treated surfaces of walls after preparation surfaces complete as per manufacturer instruction all as specified and directed. |
| 7 | M&L for 1.00 mm thick of Birla white putty/JK white wall care putty on walls surfaces including removal of existing treatment and making the surface uniform & smooth all as specified and as directed. |
| 8 | M&L for Preparation of old/new decorated surfaces incl washing, rubbing down and stopping of paint and painted surfaces and applying one coat of exterior weather proof paint white or tinted on walls, fascia of roof or chajjas, column fascia at any height on surfaces of brick, stone, concrete, asbestos cement or plastered or unplastered surfaces of bldg all as specified & directed. (Note: Application of paint to be carried out by authorised applicator and as per the manufacturer's instructions.) |
| 9 | M&L for Preparation of old/new decorated surfaces incl washing, rubbing down and stopping of paint and painted surfacesand applying two coats of exterior weather proof paint white or tinted on walls, fascia of roof or chajjas, column fascia at any height on surfaces of brick, stone, concrete, asbestos cement or plastered or unplastered surfaces of bldg all as specified & directed.(Note: Application of paint to be carried out by authorised applicator and as per the manufacturer's instructions.) |
| 10 | Taking down cement plaster any description on brick or stone walls etc including Removing of tree/plant girth not exc 15 cm from wall/roofing including removing all roots ,raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 11 | M&L for rendering 10mm thick internal surfaces on other than fair faces of brick work in cm 1:6 all as specified and as directed. |
| 12 | M&L for rendering 10 mm thick in ceiling on brick work or concrete surfaces in CM 1:4, finished even and fair complete all as specified and directed. |
| 13 | M&L 15 mm thick rendering in CM 1:4 on external surfaces of walls & top surfaces of chajja/roof/ceiling mixed with water proofing compound @ 3 % by the weight of cement(up to four story building) , surface finished even and smooth without using extra cement.(WPC shall be measured and paid seperately |
| 14 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 15 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed |
| 16 | S&F in repair PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 17 | S&Fin repair PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed. |
| 18 | S & F in repair of PVC (SWR) junction single, (Single T) 110 mm bore equal or unequal with acess door complete all as specified and directed. |
| 19 | S & F Supplying and laying of CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed |
| 20 | Supplying and laying of CPVC pipes 25 mm outer dia SDR 11 including fittings on walls/ceiling or laying in floors incl chase cutting complete all as specified |
| 21 | M& L for providing cement concrete type B0 1:2:4 (12.5mm graded aggregates) for parapets andrailings upto 60 cm in height,copings and packing pvc(swr) pipes openings complete all as specified. |
| 22 | Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings |
| 23 | S & F Pre- painted galvalume aluminum zinc coating (AZ 150) GI based corrugated steel sheet 0.50mm thick, coloured having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws at every alternate corrugations as specified and directed. |
| 24 | S & F pre-painted galvalume aluminum zinc coating (AZ 150) GI based plain steel sheet 0.5mm thick of any coloure in ridge having tensile strength of 550 Mpa fixed with self tapping screws as spd and directed by eng-in-charge etc. |
| 25 | All as per item no 2 but except sheet (refixing old sheet after cleaning and fiiling the hole) the as specified and directed. |
| 26 | M & L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry as specified and directed. |
| 27 | M & L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 as specified and directed. |
| 28 | Removing of plants including roots by demolishing of brick work/PCC/RCC in parapet sides,wall , fascia, chajjah,roof including necessary scaffolding, any type, any location/height (i.e roof parapet walls, near pipes etc) and applying acid after removing roots for preventing the regrowthing and making good the disturbed portion using PCC 1:2:4 type B-0 and plaster in CM 1:3 (size of disturbed portion 150 x 150) x 200 mm) complete all as specified and directed. |
| 29 | M&L for repairing of R.C.C projections, chajjias, roofs, facia etc in patches not exceeding 3 Sqm in eachSqmpatch by necessary preparation, Scarpping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose R.,C.C surfaces and applying one coat of cement sturry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and finished with cement and sand motar (1:3) using coarse sand and work in patches including necessary form work and applying two coats of finishes to match with the existing surfaces in at any height complete all as specified and directed by Engr-in-charge.Note: No other extra payment shall made for scaffolding and necessery arrangements for executing the Note: Quated rate shall be deemed to be inclusive of materials and all labours,tools andplants,scaffolding and working upto height 6m etc. |
| 30 | M&L for damproofing to wall with two component Acrylic polymer cementitious water proof elastomeric coating four grade mixto form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass meshcloth as first coat is still green with overlap of joint of fibremesh not less than 100mm,then finallyapply second layermix by brush to entire surfaceof container covering0.6-0.75Sqm/kg at 1mm thickin two coat dependingon the level of substrate and curing it for minimum 3 days. Note: Quated rate shall be deemed to be inclussive of materials and all laboiurs,tools and plants,scaffolding and working upto height 6m etc. |
| 31 | M&L for solar reflective coated thermoplastic heat resistant roofpaint 1mm thick made with advanced ceramic or acrylic compound complete all as specified by manufacturing instructions |
| 32 | Dismantling Framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 34 | S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etc Fe 410 W (Gde E - 250 quality A ) complete all as specified and directed . |
| 35 | All as per item no 13 but febrication only complete all as specified and directed. |
| 36 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle iron cleats or other connecting plates all as specified and directed. Fe410-W (gde-E-250) quality- A |
| 37 | Demolition of stone/brick masonry in CM or cement/ lime mortar including all qnoins, arches, pillars etc. |
| 38 | M&L for Brick work with sub class 'B' bircks straight or curved on plan exc 6mtr mean radius built in CM 1:4 complete. |
| 39 | M&L for rendering 10mm thick internal surfaces on fair faces of brick work or concrete in cm 1:6 as directed by Engr-in-charge. |
| 40 | M& L for preparation of newely plastered surface of walls and applying two coat of cement base paint over a coat of primer complete. |
| 41 | M& L for preparation of newely plastered surface of walls and applying two coat of acrylic distemper over a coat of primer as in walls complete. |
| 42 | Demolition of cement concrete Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 43 | M & L cement concrete type D2 148 (40mm graded aggregate ) as in foundation filling and mass mass concreting. |
| 44 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 45 | M&L for RCC 1:2:4 type B1 (using 20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 46 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves incl supports, overhangs, etc. also splays between floors and beams, etc. |
| 47 | S & F for hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on wall as per specifications and drawing including tanking down old complete all as specified and directed by engr in charge. |
| 48 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets |
| 49 | S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed . |
| 50 | S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed by the . |
| 51 | M&L for providing water proofing treatment over cleaned roof surfaces with super thermo APP modified water froofing membran comprssing of following for approachable roof: (i) Cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces/wall and filling of crack with sealing compound etc. (ii) Bitumen based primer conforming to IS 3384-1965 at 0.30 kg per sqm(iii) One layer of super thermo APP modified water proofing membran with non polyster reinforcement of Make (M/S STP texsa Ltd/hyperplus membrane of M/S IWL India Ltd. M/S STP and Tikki Tar Ltd ) 3mm thick and minimum weight @ 3.50 Kg/sqm laid with gas torch and fasted on roof surfaces with roller. The over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with PCC gola 1:2:4 type B1 etc adhere to bitumen all as per manufacturer instructions.(iv) Applying two coat of aluminium paint @ 0.20 kg/sqm per coat over bitumen layers as per manufacturer instruction (application including sider lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction specification complete as specified and directed. |
| 52 | Taking down chowkhat or frame not exc. 1.5 sqm (without taking shutter from the frame) |
| 53 | S&F Powder coated aluminium frame/shutters for door, windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws etc complete all as specified. Note : (i) Glazing and wire mesh shall be measured and paid separetely. (ii) Item shall be paid as per weight of aluminium section. (iii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arrangement etc as required, which shall not be measured for arriving the weight (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. |
| 54 | S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staples complete. |
| 55 | M & L For 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square of any size complete all as specified and directed by Eng-in-charge. |
| 56 | M&L for preparing new steel surfaces and applying two coats of synthetic enamel paint over coat of red oxide, zinc chrome primer, surfaces of any description, over 10cm width or girth not otherwise described. |
| 57 | M&L for preparing Old steel surfaces and applying two coats of synthetic enamel paint over coat of red oxide, zinc chrome primer, surfaces of any description, over 10cm width or girth not otherwise described. |
| 58 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises |
| 59 | M&L for 25 mm thick PCC 1:2:4 (20mm graded aggregate ) in levelling course of floor complete all as specified and directed. |
| 60 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed be in C:M 1:4 complete etc. complete all as specified and directed by engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 61 | M&L for glazed ceramic coloured tiles in verticle surface 450mmx350mmx7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over including backing coat 10mm thick cement mortar in 1:4 complete all as specified and directed by engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 62 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 63 | M&L cement concrete type E-2, 1:5:10(40 mm graded aggregate)lean concrete as in sunkun floor for filling etc. complete all as specified and directed. |
| 64 | M&L 40mm thick cement concrete type B-1, 1:2:4(20mm graded aggregate) as in sunkun floor complete all as specified and directed. |
| 65 | M&L 15mm thick plastering in CM 1:3 along the wall of toilet and bath mixed with 3 % WPC and finished even and smooth without using extra cement complete all as specified and directed. |
| 66 | Supplied only WPC |
| 67 | M&L bitumen blown any grade applied hot, two coats to concrete surfaces at the rate of 1.5 kg per sqm per coat complete all as specified and directed. |
| 68 | M&L Polythene film black 50 micron laid in floor complete all as specified and directed. |
| 69 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 70 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls of 75 mm bore of pipe etc complete all as specified and directed |
| 71 | S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed |
| 72 | PVC (SWR) vent cowl for 110 mm bore pipe complete all as specified and directed. |
| 73 | PVC (SWR) multi floor trap with grating 75 mm dia including jointing with solvent cement complete all as specified and directed. |
| 74 | S & F of 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 75 | S&F in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 76 | S&F in repair 15 mm dia bore pillar taps cast copper alloy, with capstan head, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' and 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 77 | S&F in repair 15 mm dia stop valves/angle valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 78 | S & F in repair for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect all as specified and directed. |
| 79 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 80 | S &F as in repair chromium plated Shower rose 15 mm size, 125mm long with arms complete all as specified and directed. |
| 81 | S&F vitreous china wash basin white flat back size 550 x 400mm including pedestal stand excluding taps, waste, chain & plug and porcelain stopper including brackets or fixed to walls with anchor fastners complete all as specified and directed. |
| 82 | S & F in Repair of Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as specified and directed. . . |
| 83 | S & F in repairs of vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests but incuding flush pipe and connection to the flushing cistern complete all as specified and directed |
| 84 | S & F of 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 85 | M & L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings and similar work. conforming to Fe-290 (gde E-165) Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |