Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil work |
| 2 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (13.41.1) |
| 3 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (13.99.1) |
| 4 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (9.48.2) |
| 5 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (16.53) |
| 6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (10.2) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.3) |
| 8 | Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). (14.86) |
| 9 | Painting with aluminium paint of approved brand and manufacture to give an even shade . Two or more coats on new work (13.63.1) |
| 10 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (13.46.1) |
| 11 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (15.60) |
| 12 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (18.48) |
| 13 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (15.2.1) |
| 14 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (15.2.2) |
| 15 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (22.5) |
| 16 | Providing and fixing soil, waste and vent pipes : 100 mm dia: Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 (17.35.1.2) |
| 17 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe: 32 mm dia (17.28.1.1) |
| 18 | Providing and fixing 100 mm sand cast Iron grating for gully trap. (17.29) |
| 19 | Providing and fixing plain bend of required degree. 100 mm dia: Sand cast iron S&S as per IS : 3989 (17.39.1.2) |
| 20 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.:100 mm dia: Sand cast iron S&S as per IS - 3989 (17.38.1.2) |
| 21 | Providing and fixing collar : 100 mm: Sand cast iron S&S as per IS - 3989 (17.57.1.2) |
| 22 | Providing and fixing terminal guard :100 mm: Sand cast iron S&S as per IS - 3989 (17.56.1.2) |
| 23 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm (17.58.1) |
| 24 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 (17.60.1.1) |
| 25 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.:100x100x100 mm: Sand cast iron S&S as per IS - 3989 (17.43.1.2) |
| 26 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.: 15 mm nominal bore (18.51.1) |
| 27 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore (18.49.1) |
| 28 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall15 mm dia nominal bore (18.10.1) |
| 29 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work25 mm dia nominal bore (18.12.3) |
| 30 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (4.1.8) |
| 31 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe (17.37.1) |
| 32 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (17.1.1) |
| 33 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid (17.2.1) |
| 34 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (17.5.1) |
| 35 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms (18.54.1) |
| 36 | Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms (18.55.1) |
| 37 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (18.53.1) |
| 38 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15 mm nominal bore (18.46.1) |
| 39 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (6.13.2) |
| 40 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (13.4.2) |
| 41 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) (13.5.2) |
| 42 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. (14.83) |
| 43 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 600 x 600 mm (11.41A.1.1) |
| 44 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. (11.42) |
| 45 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.(11.43) |
| 46 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm (11.47.2) |
| 47 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick (11.26.1) |
| 48 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (11.27) |
| 49 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (11.37) |
| 50 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (8.31) |
| 51 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm (9.97.3) |
| 52 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm (9.100.2) |
| 53 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (17.31) |
| 54 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (17.16A) |
| 55 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (9.96.2) |
| 56 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (15.7.4) |
| 57 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (15.56) |
| 58 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.15 mm nominal bore, 105 mm long, weighing not less than 138 gms (18.62.1) |
| 59 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (15.52) |
| 60 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :For 75 mm dia pipe (17.37.2) |
| 61 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 45 x 85 mm (26.86.2) |
| 62 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)30 mm thick (26.88.1) |
| 63 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below (15.12.1) |
| 64 | Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). (9.147.A4.1) |
| 65 | Using R2 series with frame (39mm & above ) x (39mm & above) & sash (39mm & above) x (60mm & above) & mullion (39mm & above) x (60mm & above). (Height upto 1.2 metre; each openable shutter upto 0.8m width) (9.147.E4.1) |
| 66 | Providing & fixing in position 65 mm thick factory made door frame of Phenol bonded Bamboo wood (superior class, interior use), in approved colour, texture and finish.The bamboo wood shall have minimum density of 1000 Kg/cum, minimum hardness 1000 Kgf. The door frame shall have tenon & mortise interlocking system, to be fixed to the wall with 100 mm size G.I screws all a complete as per direction of Engineer-in charge. (26.6) |
| 67 | Providing & fixing in position Phenol bonded Bamboowood panelled or panelled and glazed shutters for doors windows, clerestorey windows with pre-molded minimum 30mm thick planks, in approved colours, texture & finish. It shall have 10mm wide, 25mm deep grove to fit in panels.The bamboo wood shall have minimum density of 1000 Kg/cum, minimum Hardness 1000 Kgf. All styles and rails shall have profiled interlocking system locked in place by bamboo pins, all complete as per direction of Engineer in charge. (The panelling will be paid for separately). (26.4) |
| 68 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe (15.42.2) |
| 69 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (17.71) |
| 70 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (19.27.1) |
| 71 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (19.32.1) |
| 72 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (2.10.1.2) |
| 73 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe (19.6.2) |
| 74 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter (26.29.2) |
| 75 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. : Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make (26.31.2) |
| 76 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (5.22A.6) |
| 77 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \\"L\\" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge (26.40). |
| 78 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. (18.78) |
| 79 | Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-ChargeNote: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.25mm thick in Grade M 25 with cement content not less than 330 kg per cum (26.38.1) |
| 80 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (10.1) |
| 81 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter (26.29.2) |
| 82 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum (5.33.2.1) |
| 83 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (5.9.3) |
| 84 | Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (16.7.1) |
| 85 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (16.75) |
| 86 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (2.27) |
| 87 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (5.3) |
| 88 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter (12.41.2) |
| 89 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (12.43.2) |
| 90 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. : Bend 87.5° : 110 mm bend (12.42.5.2) |
| 91 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) :110 mm Shoe (12.42.6.2) |
| 92 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 250 mm (17.10.1.1) |
| 93 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board610x510 mm bowl depth 200 mm (17.10.2.1) |
| 94 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Float glass panes: 4 mm thick glass pane (weight not less than 10kg/sqm). (9.7.7.1) |
| 95 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.50) |
| 96 | Supply and filling of Over bunt (Jhama) Size 90 to 40 mm in sunken portion approved rate. |
| 97 | Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red : Area of slab over 0.50 sqm (M/R) |
| 98 | Providing and fixing oval shape under counter wash basin with C.P. brass single lever Basin Mixer without popup waste system with 450mm long Braided hoses, 32 mm C.P. brass waste of standard pattern, including painting of fittings, cutting and making good the walls wherever required: (M/R) |
| 99 | Providing & fixing fly proof wire mesh in PVC windown, & doors complete. Stainless steel (grade 304) wire mesh of 0.5mm dia wire and 1.4mm aperture on both sides. (M/R) |
| 100 | Providing and fixing Hand shower (Health Faucet) with 8 mm dia., 1.00 long flexible tube & wall hook with N.R.V (Back Flow Preventer) of approved make complete as per manufacturer's specifications direction of engineer-in-charge. (MR) |
| 101 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (M/R) |
| 102 | Electrical Work |
| 103 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A (1.10.1) |
| 104 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (1.10.3) |
| 105 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(1.11) |
| 106 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sqmm + 1x1.5 sqmm earth wire (1.14.1) |
| 107 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x4.0 sqmm + 1x4.0 sqmm earth wire (1.14.3) |
| 108 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6.0 sqmm + 1x6.0 sqmm earth wire (1.14.4) |
| 109 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4x10 sqmm + 2x6 sq mm earth wire (1.14.10) |
| 110 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch (1.24.1) |
| 111 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch (1.24.3) |
| 112 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet (1.24.4) |
| 113 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6/16A socket (1.24.5) |
| 114 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(1.25) |
| 115 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(1.26) |
| 116 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 module box (1.27.1) |
| 117 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(1.31) |
| 118 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(1.32) |
| 119 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.(1.56) |
| 120 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(1.33) |
| 121 | Supplying and fixing PVC batten/ angle holder including connections etc. as required.(1.58) |
| 122 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.(1.4) |
| 123 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.(1.38) |
| 124 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(1.57) |
| 125 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100A, 30 KA, FP MCCB- Thermal Range-63-100A (2.2.13) |
| 126 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125A, 36 KA, FP MCCB, Thermal Range 100-125A (2.2.14) |
| 127 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) SPDB 6 way Double Door (2.3.1) |
| 128 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) SPDB 8 way Double Door (2.3.2) |
| 129 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) SPDB 12 way Double Door (2.3.3) |
| 130 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) TPNDB 4 way (4+12) Double Door (2.4.1) |
| 131 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) TPNDB 6 way (4+18)Double Door (2.4.2) |
| 132 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) TPNDB 8 way (4+24) Double Door (2.4.3) |
| 133 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . VTPNDB 4 way (4+12) Double Door (2.5.1) |
| 134 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . VTPNDB 8 way (4+24)Double Door (2.5.2) |
| 135 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole MCB (5-32A)(2.10.1) |
| 136 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole MCB (5-32A)(2.10.3) |
| 137 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole MCB(5-63A)(2.10.4) |
| 138 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole MCB(5-63A)(2.10.5) |
| 139 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.(2.11) |
| 140 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 6 way, Double door SPN MCBDB (2.23.1) |
| 141 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB (2.23.2) |
| 142 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB (2.23.4) |
| 143 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 4 way, Double door TPN MCBDB (2.24.1) |
| 144 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB (2.24.2) |
| 145 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB (2.24.3) |
| 146 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.(2.25) |
| 147 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required (5.2) |
| 148 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(5.15) |
| 149 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. (5.16) |
| 150 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.(5.18) |
| 151 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)(7.7.1) |
| 152 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)(7.7.2) |
| 153 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)(14.16.1) |
| 154 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.(12.34) |
| 155 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre (11.3.1) |
| 156 | Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)- 450mmx450mmx600mm)=0.1215cumx28 (11.5) |
| 157 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm)(9.1.2) |
| 158 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)(9.1.33) |
| 159 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28mm) (9.1.20) |
| 160 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm) (9.1.21) |
| 161 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm) (9.1.23) |
| 162 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) suitable for false Ceiling as well as suspension lights along with all required accessories as required as per direction of EIC. Wattage-36W (M/R) |
| 163 | Providing, supplying, installation, testing and commissioning of 20W LED batten light fitting (integrated type) suitable for wall/ceiling mounting, having extruded aluminium housing with opal polycarbonate diffuser, complete with inbuilt driver, mounting accessories etc., operating on 90–300V AC, 50 Hz supply, with power factor ≥0.95, CRI ≥80 and minimum efficacy 100 lm/W, ensuring uniform glare-free illumination, conforming to BIS standards, as required. Minimum 5 year OEM warranty Make-Phillips/Wipro/Crompton (M/R) |
| 164 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim, LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Round/Square Light-18 W (M/R) |
| 165 | Providing, supplying, installation, testing and commissioning of 10W Mirror LED light fitting (integrated type) suitable for wall/ceiling mounting, having extruded aluminium housing with inbuilt diffuser, complete with inbuilt driver, mounting accessories etc., operating on 90–300V AC, 50 Hz supply, with power factor ≥0.95, CRI ≥80 and minimum efficacy 100 lm/W, ensuring uniform glare-free illumination, conforming to BIS standards, as required. Minimum 5 year OEM warranty Make-Phillips/Wipro/Crompton (M/R) |
| 166 | Providing, supplying, installation, testing and commissioning of LED Bulkhead light fitting (integrated type) suitable for wall/ceiling mounting, having pressure die-cast/extruded aluminium housing with inbuilt diffuser, complete with inbuilt driver, gasket, mounting accessories etc., operating on 90–300V AC, 50 Hz supply, with power factor ≥0.95, CRI ≥80 and minimum efficacy 100 lm/W, ensuring uniform glare-free illumination, conforming to BIS standards, as required. Minimum 5 year OEM warranty. Make – Philips/Wipro/Crompton. Wattage-8-10W (M/R) |
| 167 | Providing, supplying, installation, testing and commissioning of 9W LED bulb suitable for holder, having polycarbonate/aluminium housing with high efficiency SMD LEDs, complete with inbuilt driver etc., operating on 90–300V AC, 50 Hz supply, with power factor ≥0.90, CRI ≥80 and minimum efficacy 100 lm/W, with correlated colour temperature as required, conforming to BIS standards, as required. Minimum 2 year OEM warranty. Make – Philips/Wipro/Crompton. (M/R) |
| 168 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coatedpressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥105 <120 lm/Watt) 90W (M/R) |
| 169 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die castaluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Wattage-100W (M/R) |
| 170 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (M/R) |
| 171 | Providing & Fixing of metal body exhaust fan of 300 mm sweep, suitable for louvered/shutters/ window mounting, energy efficient motor with copper winding, low noise operation, thermal overload protection and speed of about 900 RPM or higher, Warranty- 2 Year, Make- Crompton/Usha/Bajaj/Havel's (M/R) |
| 172 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole MCB(16/25/32/63A) (M/R) |
| 173 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole MCB(16/25/32/63A) (M/R) |
| 174 | Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 16/25/32/63 A 415 V \\"C\\" curve TPN MCB complete with connections, testing and commissioning etc. as required. (2.17) |
| 175 | Providing, supplying, laying and fixing of electrical insulating rubber mat suitable for use in front of LT/HT panels in substation, made from high quality elastomeric compound, anti-skid type, conforming to relevant IS, suitable for working voltage up to 1.1 KV, having minimum thickness 3 mm, dielectric strength as per relevant IS standards, resistant to moisture, acid and oil, complete in all respect including cutting, laying etc. as required at site. Colour – Black. Make – Jyoti/Prima/Deep Jyoti or equivalent approved make. Rubber mats 1mrx2mtr, 3mm thickness, ISI marked (M/R) |
| 176 | Providing and supplying following size XLPE insulated, PVC sheathed, aluminium conductor armoured power cable, 1100 Volt grade, conforming to relevant IS, with stranded aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, galvanised steel strip/wire armour and FRLS PVC outer sheath, suitable for underground/on surface installation as required. Make – Polycab/KEI/Finolex/Havel's. Aluminium Armoured Cable 2x10sqmm (M/R) |
| 177 | Providing and supplying following size XLPE insulated, PVC sheathed, aluminium conductor armoured power cable, 1100 Volt grade, conforming to relevant IS, with stranded aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, galvanised steel strip/wire armour and FRLS PVC outer sheath, suitable for underground/on surface installation as required. Make – Polycab/KEI/Finolex/Havel's. Aluminium Armoured Cable 4 C x 16 sq mm (M/R) |
| 178 | Providing and supplying following size XLPE insulated, PVC sheathed, aluminium conductor armoured power cable, 1100 Volt grade, conforming to relevant IS, with stranded aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, galvanised steel strip/wire armour and FRLS PVC outer sheath, suitable for underground/on surface installation as required. Make – Polycab/KEI/Finolex/Havel's. Aluminium Armoured Cable 3 1/2 C x 25 sq mm (M/R) |
| 179 | Providing and supplying following size XLPE insulated, PVC sheathed, aluminium conductor armoured power cable, 1100 Volt grade, conforming to relevant IS, with stranded aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, galvanised steel strip/wire armour and FRLS PVC outer sheath, suitable for underground/on surface installation as required. Make – Polycab/KEI/Finolex/Havel's. Aluminium Armoured Cable 3 1/2 C x 35 sq mm (M/R) |
| 180 | Providing and supplying following size XLPE insulated, PVC sheathed, aluminium conductor armoured power cable, 1100 Volt grade, conforming to relevant IS, with stranded aluminium conductor, extruded XLPE insulation, extruded PVC inner sheath, galvanised steel strip/wire armour and FRLS PVC outer sheath, suitable for underground/on surface installation as required. Make – Polycab/KEI/Finolex/Havel's. Aluminium Armoured Cable 3 1/2 C x 70 sq mm (M/R) |
| 181 | Providing, supplying, laying and fixing of 80 mm dia medium class GI pipe conforming to relevant IS, including excavation, cutting of road wherever required, providing and laying GI pipe for protection of underground cable crossing, with necessary bends, sleeves, clamps, welding/threading, anti-corrosive treatment, refilling of trench, road restoration and making good the damaged surface complete as required. Make – Tata/Jindal/Prakash Surya or equivalent approved make. (M/R) |
| 182 | Providing and supplying 6 metre long pole made out of 80 mm dia medium class GI pipe conforming to relevant IS, complete with suitable base plate, GI clamp, nut bolts and painted with one coat of red oxide primer and two coats of aluminium/synthetic enamel paint as required. (M/R) |
| 183 | Supplying and fixing street Light Box/enclosure on surface/ recess along with 1 No. 5-32A, 240 volts “C” curve SP MCB, 3-4 No. Control Terminal 4way mounted on suitable DIN Rail, complete with connections, testing and commissioning etc. and allied bricks works (if any) as per site requirement. Min Dimension of Box 150x150x100mm. (M/R) |
| 184 | Supplying and drawing 3 core 1.5 sqmm 1.1 KV grade, PVC insulated copper conductor multicore cable in the existing poles and brackets from cable termination connector to the firing including providing suitable lugs/thimbles connections etc as req. (Make-L&T/Finolex/Polycab) (M/R) |
| 185 | supplying, installation, testing and commissioning of outdoor type double door, wall mounted cubical Energy Meter Board suitable for installation of 6 Nos. single phase energy meters, fabricated from CRCA sheet steel, dust and vermin proof construction, complete with powder coated finish in approved shade, suitable for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply system.panel shall be compartmentalized type design having separate compartments for energy meters, separate MCBs box, Main switch box, cable alley and bus bar chamber, complete with locking and sealing arrangement as per approved drawing. The panel shall be provided with 5/6 mm thick hylam/bakelite sheet in each energy meter compartment.The panel shall be provided with 4 Nos. 100 Amps aluminium bus bars of high conductivity, extensible type TPN aluminium bus bar system, complete with common aluminium earth strip of size 25 mm × 5 mm at rear side with 2 Nos. earth studs, solid bus bar connections to switchgears, cable alleys, removable gland plates and internal control wiring with 1.5 sq.mm PVC insulated copper conductor cable etc. complete as required. Depth of panel shall not be less than 250 mm. The panel shall be complete with 6 Nos. single phase energy meters and 6 Nos. double pole MCBs (5–32 Amp), 1 No. 63A Four Pole MCB installed in cubicles, including all accessories, hardware, termination, interconnection, testing and commissioning complete as required at site. (M/R) |
| 186 | supplying, installation, testing and commissioning of outdoor type Street Light Panel, wall/pole mounted, fabricated out of CRCA sheet steel, dust and vermin proof, weatherproof construction with IP-54 protection class, complete with powder coated finish in approved shade, suitable for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply system. The panel shall be provided with suitable capacity TPN 100A aluminium bus bars, neutral link, earth bar, 100A power contactor, timer/digital astronomical timer, MCB/MCCB incomer and 3 no. Double Pole 63A outgoing feeders, indicating lamps, control wiring with FRLS copper conductor, cable alleys, gland plates, earthing terminals, suitable locking arrangement and all accessories required for automatic/manual operation of street lighting system complete as required for 3 outgoing ckt. Make- Havel's and equivalent (M/R) |
| 187 | Fabrication, Supply, Installation, Testing & Commissioning of cubical type LT Panel, floor/wall mounted, (front area 1.7sqmt approx.) preferably 2 vertical with Separate busbar chamber & cable alley, fabricated out of 2.0 mm thick CRCA sheet steel, compartmentalised, dust & vermin proof, suitable for operation on 415 Volts, 3 Phase, 4 wire, 50 Hz AC supply system, complete with hinged lockable doors, powder coated after 7 tank treatment process, cable alley, interconnections with suitable size copper conductor/solid copper strip/aluminium strip, earth terminals, numbering etc. including internal wiring, outgoing terminals, links, and mounting of following switchgears/accessories complete in all respects as required, conforming to IP-42 protection class with following items/feeders. i) Digital multifunction meter 0–500V complete with CTs and selector switch – 1 Setii) LED type RYB phase indicating lamp – 1 Setiii) Aluminium busbar 3 Phase 4 wire 300A – 1 Setiv) 125-160A, 36kA, 4 Pole MCCB with rotary handle – 1 No.v) 200A Change Over Switch 4Pole with Rotary Handel-1 No. vi) 100A, 36kA, 4 Pole MCCB with rotary handle Thermal Range 63-100A– 4 Nos.vii) Space suitable for 63A TP MCCB – 1 No.viii) MCB OG Feeder with 3 No. 32-63A DP MCB-1No. including all accessories required for satisfactory operation, complete as required as per direction of EIC. Name of Panel- Essential Panel (M/R) |
| 188 | Fabrication, Supply, Installation, Testing & Commissioning of cubical type LT Panel, floor/wall mounted, (front area 2sqmt approx.) preferably 2 vertical with Separate busbar chamber & cable alley, fabricated out of 2.0 mm thick CRCA sheet steel, compartmentalised, dust & vermin proof, suitable for operation on 415 Volts, 3 Phase, 4 wire, 50 Hz AC supply system, complete with hinged lockable doors, powder coated after 7 tank treatment process, cable alley, interconnections with suitable size copper conductor/solid copper strip/aluminium strip, earth terminals, numbering etc. including internal wiring, outgoing terminals, links, and mounting of following switchgears/accessories complete in all respects as required, conforming to IP-42 protection class with following items/feeders. i) 250 Amp, 36 kA, 4 Pole MCCB incomer – 1 No.ii) Digital multifunction meter 0–500 V complete with CTs and selector switch – 1 Setiii) LED type RYB phase indicating lamp – 1 Setiv) Set of 4 Nos. Aluminium busbar 300A – 1 Setv) 125 Amp, 36 kA, 4 Pole MCCB outgoing with rotary handle – 2 Nos.vi) 100 Amp, 30 kA, 4 Pole MCCB outgoing with rotary handle – 4 Nos.vii) Space suitable for 100 Amp TP MCCB – 1 No.viii) 32 Amp DP MCB – 3 Nos.including all accessories required for satisfactory operation, complete as required as per direction of EIC. Name of Panel- Non Essential Panel (M/R) |
| 189 | Providing, fabricating, supplying and fixing street light bracket made out of 32 mm dia medium class G.I. pipe having 500 mm long arm and 200 mm long holding portion (with 100mm Medium Class GI Pipe), weld at suitable angle (approx. 15°) for mounting street light fitting/luminaire, including cutting, welding, drilling holes for cable entry, suitable clamps, 4 set of nuts, bolts, painting with primer and finish paint etc. complete in all respects and suitable for fixing on pole/wall as required and as directed by Engineer-in-Charge. (M/R) |
| 190 | DG Set Silent with AMPF panel including all accessories, Rating- 50KVA. Refer enclose Technical specification (Ann-1) for DG Set (DSR) |
| 191 | Buyback of Existing old wirings/wooden boards, switches/sockets/non-working light fittings etc. (M/R) |
| 192 | Buyback of Existing DG Set Old Model from site including including dismantling and taking away existing DG set complete as required, 5KVA Kirlosker Make DG. (M/R) |
| 193 | Buyback of Existing DG Set Old Model from site including including dismantling and taking away existing DG set complete as required, 15KVA Kirlosker make DG. (M/R) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy