| Sl. No. | Item Title | Item Description |
| 1 | Scrapping of the existing meter box/DB box of Type IV/Type V buildings made in wall cut-outs. The scope of work shall include scraping the wooden door, frame and DBs with MCBs installed in the meter box, as well as removing any connections, disconnecting the cables and removing glands. Removal of ICTPN/SFU/SDF/MCCB/MCB of rating up to 125A; removal of cables (up to 4CX70 sq mm Al or copper cable). MS conduits of all sizes, etc., shall also be included in scope. Maximum size of the meter box/DB box: 1550 mm X 860 mm X 30 mm | Scrapping of the existing meter box/DB box of Type IV/Type V buildings made in wall cut-outs. The scope of work shall include scraping the wooden door, frame and DBs with MCBs installed in the meter box, as well as removing any connections, disconnecting the cables and removing glands. Removal of ICTPN/SFU/SDF/MCCB/MCB of rating up to 125A; removal of cables (up to 4CX70 sq mm Al or copper cable). MS conduits of all sizes, etc., shall also be included in scope. Maximum size of the meter box/DB box: 1550 mm X 860 mm X 30 mm |
| 2 | Removal of L&T EM101+ with RF port from the meter box by removing all connections, noting the KWH reading, and inspecting and testing for proper functioning of the removed KWH meter. Scope shall also include installing and commissioning the same into the newly fabricated meter box. Meter readings at the time of removal and reinstallation shall be submitted with the stamp and the sign of the supervisor licence holder along with the soft copy in an XL sheet. Meter shall be labelled with quarter no. | Removal of L&T EM101+ with RF port from the meter box by removing all connections, noting the KWH reading, and inspecting and testing for proper functioning of the removed KWH meter. Scope shall also include installing and commissioning the same into the newly fabricated meter box. Meter readings at the time of removal and reinstallation shall be submitted with the stamp and the sign of the supervisor licence holder along with the soft copy in an XL sheet. Meter shall be labelled with quarter no. |
| 3 | Supply and installing paddle lock with single master key for all meter box. | Supply and installing paddle lock with single master key for all meter box. |
| 4 | Upkeeping and preventive maintenance of the meter box: The scope shall include checking for loose connections, tightening the connection if any of all incoming and outgoing connections, and removing any worn-out component/cables/terminals/connectors. The scope shall also include dressing of interconnecting leads using UPVC panel trunking. Maximum size of the meter box/DB box: 1550 mm X 860 mm X 30 mm | Upkeeping and preventive maintenance of the meter box: The scope shall include checking for loose connections, tightening the connection if any of all incoming and outgoing connections, and removing any worn-out component/cables/terminals/connectors. The scope shall also include dressing of interconnecting leads using UPVC panel trunking. Maximum size of the meter box/DB box: 1550 mm X 860 mm X 30 mm |
| 5 | Supply, installation and commissioning of UPVC panal slotted trunking in provided meter box; Approximate size : 45 mm X 45 mm or 50 mm X 50 mm as per site requirement. | Supply, installation and commissioning of UPVC panal slotted trunking in provided meter box; Approximate size : 45 mm X 45 mm or 50 mm X 50 mm as per site requirement. |
| 6 | Supply, installation and commissioning of uPVC panel slotted trunking in the provided meter box. Approximate size of UPVC slotted trunking: 45 mm X 45 mm or 75 mm X 75 mm as per site requirement. Colour shall be of grey (RAL 7042), material shall be of high impact, rigid, self extinguishing uPVC -FRLS )Make : Precision /Rolycab/Modi/Legrand | Supply, installation and commissioning of uPVC panel slotted trunking in the provided meter box. Approximate size of UPVC slotted trunking: 45 mm X 45 mm or 75 mm X 75 mm as per site requirement. Colour shall be of grey (RAL 7042), material shall be of high impact, rigid, self extinguishing uPVC -FRLS )Make : Precision /Rolycab/Modi/Legrand |
| 7 | Supply, laying/ installingt of high-quality PVC conduit in provided wall with OD 32 mm suitable for laying service main. Conduit shall be fixed with suitable clamps as per relevent IS standerds. make: Precision/Rolycab/Modi/Legrand | Supply, laying/ installingt of high-quality PVC conduit in provided wall with OD 32 mm suitable for laying service main. Conduit shall be fixed with suitable clamps as per relevent IS standerds. make: Precision/Rolycab/Modi/Legrand |
| 8 | Supply, laying/ installingt of high-quality PVC conduit in provided wall with OD 40 mm suitable for laying service main. Conduit shall be fixed with suitable clamps as per relevent IS standerds. Make: Precision/Rolycab/Modi/Legrand | Supply, laying/ installingt of high-quality PVC conduit in provided wall with OD 40 mm suitable for laying service main. Conduit shall be fixed with suitable clamps as per relevent IS standerds. Make: Precision/Rolycab/Modi/Legrand |
| 9 | Supply, laying/ installingt of high-quality PVC conduit in provided wall with OD 50 mm suitable for laying service main of make: Precision/Rolycab/Modi/Legrand. Conduit shall be fixed with suitable clamps as per relevent IS standerds | Supply, laying/ installingt of high-quality PVC conduit in provided wall with OD 50 mm suitable for laying service main of make: Precision/Rolycab/Modi/Legrand. Conduit shall be fixed with suitable clamps as per relevent IS standerds |
| 10 | Supply and installation of self-adhesive, waterproof warning stickers made from waterproof inkjet vinyl sheets or equivalent in compliance with IS 2551 and CEA regulations of size 200 mm X 200 mm. Ink shall be pigment-based ink with superior UV resistance and no-fade properties. A standard electrical warning sticker must follow these design constraints:Symbol: The \\"Skull and Crossbones\\" symbol with a high-voltage lightning bolt (inside an equilateral triangle) Background: Signal Yellow or White.Border & Symbol: Black.Text: Red (for \\"DANGER\\") or Black (for \\"CAUTION\\").Trilingual text: English, Hindi, and Marathi.Mandatory Text ElementsHeader: \\"DANGER\\" or \\"CAUTION\\".Voltage Level: e.g., \\"440 VOLTS\\" or \\"230 VOLTS\\".Instruction: \\"Keep Out\\" or \\"Authorised Personnel Only\\". | Supply and installation of self-adhesive, waterproof warning stickers made from waterproof inkjet vinyl sheets or equivalent in compliance with IS 2551 and CEA regulations of size 200 mm X 200 mm. Ink shall be pigment-based ink with superior UV resistance and no-fade properties. A standard electrical warning sticker must follow these design constraints:Symbol: The \\"Skull and Crossbones\\" symbol with a high-voltage lightning bolt (inside an equilateral triangle) Background: Signal Yellow or White.Border & Symbol: Black.Text: Red (for \\"DANGER\\") or Black (for \\"CAUTION\\").Trilingual text: English, Hindi, and Marathi.Mandatory Text ElementsHeader: \\"DANGER\\" or \\"CAUTION\\".Voltage Level: e.g., \\"440 VOLTS\\" or \\"230 VOLTS\\".Instruction: \\"Keep Out\\" or \\"Authorised Personnel Only\\". |
| 11 | Supply, installation and commissioning of earth link of heavy-duty, high-conductivity brass, nickel-plated or tin-plated, rated for 63A or higher. It shall be suitable for a minimum of one in and seven out and suitable for 10 to 16 sq mm incoming lead and 6 sq mm outgoing leads. (6mm to 8mm screw terminals). Double screw per hole (brass or zinc-plated steel) to ensure a vibration-proof grip on strands. The earth link shall be with a nylon/polycarbonate insulated base. | Supply, installation and commissioning of earth link of heavy-duty, high-conductivity brass, nickel-plated or tin-plated, rated for 63A or higher. It shall be suitable for a minimum of one in and seven out and suitable for 10 to 16 sq mm incoming lead and 6 sq mm outgoing leads. (6mm to 8mm screw terminals). Double screw per hole (brass or zinc-plated steel) to ensure a vibration-proof grip on strands. The earth link shall be with a nylon/polycarbonate insulated base. |
| 12 | Supply installation of a disconnecting-type heavy-duty neutral link of a minimum rating of 100A of electrolytic brass or tinned copper mounted on a high dielectric glass-reinforced Nulon (Nylon 66)/DMC. It shall contain a fixed terminal block and a removable or hinged solid brass link (bridge), suitable for 415 V / 600 V AC operations. Terminals shall be provided with zinc-plated/brass screws for secure clamping of 35/70 sq. mm cable leads. | Supply installation of a disconnecting-type heavy-duty neutral link of a minimum rating of 100A of electrolytic brass or tinned copper mounted on a high dielectric glass-reinforced Nulon (Nylon 66)/DMC. It shall contain a fixed terminal block and a removable or hinged solid brass link (bridge), suitable for 415 V / 600 V AC operations. Terminals shall be provided with zinc-plated/brass screws for secure clamping of 35/70 sq. mm cable leads. |
| 13 | Refurbishment /Fabrication of meter box in provided wall cutout:a. supply and installation of laminate finish (teak wood design or rosewood design) wooden frame (20 mm thickness) with double door for the meter box made in the wall. The door shall be with a door frame (14 mm thickness) and a transparent acrylic sheet. (5mm thickness). Frame size: 870 mm x 740 mm; door opening size: 770 mm x 640 mm.b. De-silting, cleaning, anti-corrosive surface treatment (epoxy double coating) of MS box available in the wall cut-out.d. Installation of the fire-retardant, marine-grade (IS: 710) plywood, component mounting and internal wiring:d. Civil works like chiselling/plastering/brickwork/PCC work/painting worke. Restoration by rectifying the workspace in all aspects, including paintingf. All openings must be closed properly for preventing accidental contact, Vermin & Pest Entry etc | Refurbishment /Fabrication of meter box in provided wall cutout:a. supply and installation of laminate finish (teak wood design or rosewood design) wooden frame (20 mm thickness) with double door for the meter box made in the wall. The door shall be with a door frame (14 mm thickness) and a transparent acrylic sheet. (5mm thickness). Frame size: 870 mm x 740 mm; door opening size: 770 mm x 640 mm.b. De-silting, cleaning, anti-corrosive surface treatment (epoxy double coating) of MS box available in the wall cut-out.d. Installation of the fire-retardant, marine-grade (IS: 710) plywood, component mounting and internal wiring:d. Civil works like chiselling/plastering/brickwork/PCC work/painting worke. Restoration by rectifying the workspace in all aspects, including paintingf. All openings must be closed properly for preventing accidental contact, Vermin & Pest Entry etc |
| 14 | Refurbishment /Fabrication of meter box in provided wall cutout:865 mm X865 mm X 250mma. Main Outer Frame Fabrication from an extruded aluminium rectangular hollow section core-filled with 19 mm marine-grade plywood (IS:710) of size 50.8 mm x 38.1 mm (2\\" x 1.5\\") with a gauge of 14. The overall frame outer size shall be 865 mm x 865 mm. Shutter Frame: Fabricated from standard aluminium hollow sections of 19 mm x 38 mm (3/4\\" x 1.5\\"), 14-gauge. Door Configuration: Double-leaf (split) design, meeting at the centre with a dedicated overlapping \\"T\\" section or rebated joint to prevent gaps. Infills (Main Body): 4.0 mm Thick ACP. Hinges: Heavy-duty SS 304 grade butt hinges (minimum 3 hinges per leaf). An SS latch is to be provided. Secondary Locking: A magnetic door catch/lock (heavy-duty) is to be installed at the top/bottom. b. De-silting, cleaning, anti-corrosive surface treatment (epoxy double coating) of MS boxd. Installation of the fire-retardant, marine-grade (IS: 710) plywood, component mounting and internal wiring:d. Civil works like chiselling/plastering/brickwork/PCC work/painting worke. Restoration by rectifying the workspace in all aspects, including paintingf. All openings must be closed properly for preventing accidental contact, vermin & pest entry, etc. | Refurbishment /Fabrication of meter box in provided wall cutout:865 mm X865 mm X 250mma. Main Outer Frame Fabrication from an extruded aluminium rectangular hollow section core-filled with 19 mm marine-grade plywood (IS:710) of size 50.8 mm x 38.1 mm (2\\" x 1.5\\") with a gauge of 14. The overall frame outer size shall be 865 mm x 865 mm. Shutter Frame: Fabricated from standard aluminium hollow sections of 19 mm x 38 mm (3/4\\" x 1.5\\"), 14-gauge. Door Configuration: Double-leaf (split) design, meeting at the centre with a dedicated overlapping \\"T\\" section or rebated joint to prevent gaps. Infills (Main Body): 4.0 mm Thick ACP. Hinges: Heavy-duty SS 304 grade butt hinges (minimum 3 hinges per leaf). An SS latch is to be provided. Secondary Locking: A magnetic door catch/lock (heavy-duty) is to be installed at the top/bottom. b. De-silting, cleaning, anti-corrosive surface treatment (epoxy double coating) of MS boxd. Installation of the fire-retardant, marine-grade (IS: 710) plywood, component mounting and internal wiring:d. Civil works like chiselling/plastering/brickwork/PCC work/painting worke. Restoration by rectifying the workspace in all aspects, including paintingf. All openings must be closed properly for preventing accidental contact, vermin & pest entry, etc. |
| 15 | Refurbishment /Fabrication of meter box in provided wall cutout:1550 mm X 860 mm X 250mma. Main Outer Frame Fabrication from an extruded aluminium rectangular hollow section core-filled with 19 mm marine-grade plywood (IS:710) of size 50.8 mm x 38.1 mm (2\\" x 1.5\\") with a gauge of 14. The overall frame outer size shall be 865 mm x 865 mm. Shutter Frame: Fabricated from standard aluminium hollow sections of 19 mm x 38 mm (3/4\\" x 1.5\\"), 14-gauge. Door Configuration: Double-leaf (split) design, meeting at the centre with a dedicated overlapping \\"T\\" section or rebated joint to prevent gaps. Infills (Main Body): 4.0 mm Thick ACP. Hinges: Heavy-duty SS 304 grade butt hinges (minimum 3 hinges per leaf). An SS latch is to be provided. Secondary Locking: A magnetic door catch/lock (heavy-duty) is to be installed at the top/bottom. b. De-silting, cleaning, anti-corrosive surface treatment (epoxy double coating) of MS boxd. Installation of the fire-retardant, marine-grade (IS: 710) plywood, component mounting and internal wiring:d. Civil works like chiselling/plastering/brickwork/PCC work/painting worke. Restoration by rectifying the workspace in all aspects, including paintingf. All openings must be closed properly for preventing accidental contact, vermin & pest entry, etc. | Refurbishment /Fabrication of meter box in provided wall cutout:1550 mm X 860 mm X 250mma. Main Outer Frame Fabrication from an extruded aluminium rectangular hollow section core-filled with 19 mm marine-grade plywood (IS:710) of size 50.8 mm x 38.1 mm (2\\" x 1.5\\") with a gauge of 14. The overall frame outer size shall be 865 mm x 865 mm. Shutter Frame: Fabricated from standard aluminium hollow sections of 19 mm x 38 mm (3/4\\" x 1.5\\"), 14-gauge. Door Configuration: Double-leaf (split) design, meeting at the centre with a dedicated overlapping \\"T\\" section or rebated joint to prevent gaps. Infills (Main Body): 4.0 mm Thick ACP. Hinges: Heavy-duty SS 304 grade butt hinges (minimum 3 hinges per leaf). An SS latch is to be provided. Secondary Locking: A magnetic door catch/lock (heavy-duty) is to be installed at the top/bottom. b. De-silting, cleaning, anti-corrosive surface treatment (epoxy double coating) of MS boxd. Installation of the fire-retardant, marine-grade (IS: 710) plywood, component mounting and internal wiring:d. Civil works like chiselling/plastering/brickwork/PCC work/painting worke. Restoration by rectifying the workspace in all aspects, including paintingf. All openings must be closed properly for preventing accidental contact, vermin & pest entry, etc. |
| 16 | Installation of the fire retardant (IS 5509), marine grade (IS: 710) plywood in the provided meter box / meter panel of thickness 19 mm. Plywood must be precisely cut to fit the inner dimensions of the meter box/wall cut-out/panel. Secure the ply using SS/GI-coated screws. A gap of 5 mm should be maintained from the wall surface using PVC spacers. Make : Century ply /Green Ply/Sandra Plywood/ Kit Ply | Installation of the fire retardant (IS 5509), marine grade (IS: 710) plywood in the provided meter box / meter panel of thickness 19 mm. Plywood must be precisely cut to fit the inner dimensions of the meter box/wall cut-out/panel. Secure the ply using SS/GI-coated screws. A gap of 5 mm should be maintained from the wall surface using PVC spacers. Make : Century ply /Green Ply/Sandra Plywood/ Kit Ply |
| 17 | Housekeeping & Scrap Management: Systematic collection, segregation, and shifting of all types of scrap generated during the refurbishment of the meter box. Scope shall also include shifting of segregated scrap from the workspace to the Designated Scrap Yard or Central Stores using contractor-provided trolleys, carts, or vehicles as approved by the Site-in-Charge.The workspace must be cleared of all debris and scrap immediately after the completion of the job.Documentation indicating scrap shifted and the destination, duly signed by the Site-in-Charge. | Housekeeping & Scrap Management: Systematic collection, segregation, and shifting of all types of scrap generated during the refurbishment of the meter box. Scope shall also include shifting of segregated scrap from the workspace to the Designated Scrap Yard or Central Stores using contractor-provided trolleys, carts, or vehicles as approved by the Site-in-Charge.The workspace must be cleared of all debris and scrap immediately after the completion of the job.Documentation indicating scrap shifted and the destination, duly signed by the Site-in-Charge. |
| 18 | Identifyying under ground power cable / metalic pipe line with emf locator etc and giving clearence for digging | Identifyying under ground power cable / metalic pipe line with emf locator etc and giving clearence for digging |
| 19 | Fabrication of the seperator/ door/gland plate /meter box as per site condition from 16 SWG CRCA steel adhering to IP 54 protection class, confirming to IEC 61439 Part -1 and 2. Form of fabrication shall be form 3B. Fabricated panal shall be dust and vermin proof. All required material including CRCA stell shall be in the contractor's scope. | Fabrication of the seperator/ door/gland plate /meter box as per site condition from 16 SWG CRCA steel adhering to IP 54 protection class, confirming to IEC 61439 Part -1 and 2. Form of fabrication shall be form 3B. Fabricated panal shall be dust and vermin proof. All required material including CRCA stell shall be in the contractor's scope. |
| 20 | Pre-treatment of the fabricated seperator/ door/gland plate /meter box with 7tank process before powder coated to epoxy shade Siemens Gray (RAL 7032). | Pre-treatment of the fabricated seperator/ door/gland plate /meter box with 7tank process before powder coated to epoxy shade Siemens Gray (RAL 7032). |
| 21 | Supply, installation of colour coded, tin coated copper busbar as per IS 1897:1983, electrolytic, oxygone free high conductivity in the provided feeder pillar/panal / meter box with all required insulations supports | Supply, installation of colour coded, tin coated copper busbar as per IS 1897:1983, electrolytic, oxygone free high conductivity in the provided feeder pillar/panal / meter box with all required insulations supports |
| 22 | Supply, installation of colour coded Aluminum busbar as per ASTM B236, ASTM B317, IEC 60853 and UL4864 in the provided panal or meter box with all required insulations supports | Supply, installation of colour coded Aluminum busbar as per ASTM B236, ASTM B317, IEC 60853 and UL4864 in the provided panal or meter box with all required insulations supports |
| 23 | Supply, installation or replace poly carbonate sheet of the thickness 2mm on provided Meter Box. | Supply, installation or replace poly carbonate sheet of the thickness 2mm on provided Meter Box. |
| 24 | Replacement of defunct MCCB or installing new MCCB as per site requirement: Supply, installation and commissioning of 200 A TP+NL MCCB, 25 Ka with rotating handle + aux contact + TAC on provided meter box or MCC. Preferred Make: - L&K, Schneider, and ABB MCCBs shall be installed with the required MCCB separator on the input and output side. Removal of old MCCB, if any, with all connections shall be in the bidder's scope. All required materials for the installation of the supplied MCCB and commissioning of the MCCB must be provided by the bidder. | Replacement of defunct MCCB or installing new MCCB as per site requirement: Supply, installation and commissioning of 200 A TP+NL MCCB, 25 Ka with rotating handle + aux contact + TAC on provided meter box or MCC. Preferred Make: - L&K, Schneider, and ABB MCCBs shall be installed with the required MCCB separator on the input and output side. Removal of old MCCB, if any, with all connections shall be in the bidder's scope. All required materials for the installation of the supplied MCCB and commissioning of the MCCB must be provided by the bidder. |
| 25 | Replacement of defunct MCCB or installing new MCCB as per site requirement: supply, installation and commissioning of 80 A TP+NL MCCB, 25 Ka with rotating handle + aux contact + TAC on provided meter box or MCC. Preferred Make: - L&K, Schneider, and ABB MCCBs shall be installed with the required MCCB separator on the input and output side. Removal of old MCCB, if any, with all connections shall be in the bidder's scope. All required materials for the installation of the supplied MCCB and commissioning of the MCCB must be provided by the bidder. | Replacement of defunct MCCB or installing new MCCB as per site requirement: supply, installation and commissioning of 80 A TP+NL MCCB, 25 Ka with rotating handle + aux contact + TAC on provided meter box or MCC. Preferred Make: - L&K, Schneider, and ABB MCCBs shall be installed with the required MCCB separator on the input and output side. Removal of old MCCB, if any, with all connections shall be in the bidder's scope. All required materials for the installation of the supplied MCCB and commissioning of the MCCB must be provided by the bidder. |
| 26 | Supply, replacement or installation and commissioning of LED Indication lamp for ON/Off/Trip, R-Y-B etc as per requirement. Supplied shall be of reputed make. Colour of supplied lamps shall be of as relevent IEC standerds. | Supply, replacement or installation and commissioning of LED Indication lamp for ON/Off/Trip, R-Y-B etc as per requirement. Supplied shall be of reputed make. Colour of supplied lamps shall be of as relevent IEC standerds. |
| 27 | Board wiring of Meter box/ panal with supply of 1.5 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction. All materials required to comp-lete board wiring with in the provided meter box shall be in the bidder scope | Board wiring of Meter box/ panal with supply of 1.5 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction. All materials required to comp-lete board wiring with in the provided meter box shall be in the bidder scope |
| 28 | Board wiring of Meter box/ panal with 2.5 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction | Board wiring of Meter box/ panal with 2.5 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction |
| 29 | Board wiring of Meter box/ panal with 6 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction | Board wiring of Meter box/ panal with 6 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction |
| 30 | Board wiring of Meter box/ panal with 10 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction | Board wiring of Meter box/ panal with 10 sqmm copper lead of reputed companies like polycab/filox/KEI etc as per site in charge instruction |
| 31 | Supplying, installaing / replacing panal lock keys (Front knob type lock the Open- Close label) | Supplying, installaing / replacing panal lock keys (Front knob type lock the Open- Close label) |
| 32 | Supply, insttalation / replacement of the multi function meter : Prefered Make : Elmeasure/Selec/L & K /ABB/Schneider/Siemens/Trinity | Supply, insttalation / replacement of the multi function meter : Prefered Make : Elmeasure/Selec/L & K /ABB/Schneider/Siemens/Trinity |
| 33 | Supply, installation/ replacement of metering class 100/5A CT Prefered make : Elmeasure /Rishab/ CG/ L & K / Newtek/Trinity/A.E (Caliberation certificate need to be submitted) | Supply, installation/ replacement of metering class 100/5A CT Prefered make : Elmeasure /Rishab/ CG/ L & K / Newtek/Trinity/A.E (Caliberation certificate need to be submitted) |
| 34 | Supply, installation / replacement of control MCBs, 6A (Prefered Make : Legrand/Hager/L&K/Havells/Seimens/ABB/Schneider ) | Supply, installation / replacement of control MCBs, 6A (Prefered Make : Legrand/Hager/L&K/Havells/Seimens/ABB/Schneider ) |
| 35 | Supply, install / replace 40A 4P MCB, 10KA or above, C’curve (Prefered Make : Legrand/Hager/L&K/Havells/Seimens/ABB/Schneider ) | Supply, install / replace 40A 4P MCB, 10KA or above, C’curve (Prefered Make : Legrand/Hager/L&K/Havells/Seimens/ABB/Schneider ) |
| 36 | Supply, install / replace 40A 4P RCBO, 30mA /100mA/300mA (Prefered Make : Legrand/Hager/L&K/Seimens/ABB/Schneider ) | Supply, install / replace 40A 4P RCBO, 30mA /100mA/300mA (Prefered Make : Legrand/Hager/L&K/Seimens/ABB/Schneider ) |
| 37 | Supply, install / replace 25A 4P MCB, 10Ka, C’curve (Prefered Make : Legrand/Hager/L&K/Havells/Seimens/ABB/Schneider ) | Supply, install / replace 25A 4P MCB, 10Ka, C’curve (Prefered Make : Legrand/Hager/L&K/Havells/Seimens/ABB/Schneider ) |
| 38 | Installation and commissioning of departmentally supplied 2-model RCBO in the provided meter box, with a 2-pole MCB PVC box of good quality, and completing all required connections. Acope shall also include labelling of RCBO with a waterproof self-adhesive vinyl-inkjet sticker. | Installation and commissioning of departmentally supplied 2-model RCBO in the provided meter box, with a 2-pole MCB PVC box of good quality, and completing all required connections. Acope shall also include labelling of RCBO with a waterproof self-adhesive vinyl-inkjet sticker. |
| 39 | Connection of 2 or 3 core cables to the provided RCBO extension board / arranging temporary supply with departmentally provided components / installing or removing departmentally supplied HF or HN fuses / checking tightness of termination / busbar / insulation / or similar miscellaneous electrical jobs. An appropriate fuse puller arrangement shall be in the scope of the contractor. (The job has to be carried out by licensed technicians only; a helper also must be deployed to support the licensed technician. If instructed, the contractor must ensure the availability of the required manpower as directed. The minimum assured quantity per day is only 25; the price shall be quoted by considering the same.) | Connection of 2 or 3 core cables to the provided RCBO extension board / arranging temporary supply with departmentally provided components / installing or removing departmentally supplied HF or HN fuses / checking tightness of termination / busbar / insulation / or similar miscellaneous electrical jobs. An appropriate fuse puller arrangement shall be in the scope of the contractor. (The job has to be carried out by licensed technicians only; a helper also must be deployed to support the licensed technician. If instructed, the contractor must ensure the availability of the required manpower as directed. The minimum assured quantity per day is only 25; the price shall be quoted by considering the same.) |
| 40 | Comprehensive electrical safety audit (Compliance to IS 732), taking necessary corrective action, housekeeping and scrap management of newly renovated Type II buildings. The work must be executed and certified by a valid electrical licence holder.Scope shall include testing of house wiring by IR test, verifying the mechanical and electrical performance of all MCBs, RCBOs, switches, fans, and lamp holders, physical verification of fan hooks for structural integrity, and checking the presence/continuity of the earthing wire in all switchboards and power points. Scope shall also include cleaning of dust/carbon from all electrical components using non-conductive cleaners, systematic dressing and bunching of loose/unorganised wires inside switchboards and Distribution Boards (DBs) using nylon cable ties and proper routing.All redundant openings in MCB DBs, switchboards, and cable entry points shall be closed using dummy plates, cable gland plugs, or appropriate sealing compounds to prevent dust and pest entry. All scrap generated shall be segregated and removed to the designated.The contractor shall also perform necessary civil repairs, including plastering, filling of cracks, and touch-up work for any damages caused to walls or ceilings during the execution of electrical inspections or repairs, restoring the surface to its original finish.A completion & compliance report signed and stamped by a valid electrical wiring licence holder shall be submitted. | Comprehensive electrical safety audit (Compliance to IS 732), taking necessary corrective action, housekeeping and scrap management of newly renovated Type II buildings. The work must be executed and certified by a valid electrical licence holder.Scope shall include testing of house wiring by IR test, verifying the mechanical and electrical performance of all MCBs, RCBOs, switches, fans, and lamp holders, physical verification of fan hooks for structural integrity, and checking the presence/continuity of the earthing wire in all switchboards and power points. Scope shall also include cleaning of dust/carbon from all electrical components using non-conductive cleaners, systematic dressing and bunching of loose/unorganised wires inside switchboards and Distribution Boards (DBs) using nylon cable ties and proper routing.All redundant openings in MCB DBs, switchboards, and cable entry points shall be closed using dummy plates, cable gland plugs, or appropriate sealing compounds to prevent dust and pest entry. All scrap generated shall be segregated and removed to the designated.The contractor shall also perform necessary civil repairs, including plastering, filling of cracks, and touch-up work for any damages caused to walls or ceilings during the execution of electrical inspections or repairs, restoring the surface to its original finish.A completion & compliance report signed and stamped by a valid electrical wiring licence holder shall be submitted. |
| 41 | Comprehensive electrical safety audit (IS 732), taking necessary corrective action, housekeeping and scrap management of newly renovated Type III & B type buildings. The work must be executed and certified by a valid electrical licence holder.Scope shall include testing of house wiring by IR test, verifying the mechanical and electrical performance of all MCBs, RCBOs, switches, fans, and lamp holders, physical verification of fan hooks for structural integrity, and checking the presence/continuity of the earthing wire in all switchboards and power points. Scope shall also include cleaning of dust/carbon from all electrical components using non-conductive cleaners, systematic dressing and bunching of loose/unorganised wires inside switchboards and Distribution Boards (DBs) using nylon cable ties and proper routing.All redundant openings in MCB DBs, switchboards, and cable entry points shall be closed using dummy plates, cable gland plugs, or appropriate sealing compounds to prevent dust and pest entry. All scrap generated shall be segregated and removed to the designated.The contractor shall also perform necessary civil repairs, including plastering, filling of cracks, and touch-up work for any damages caused to walls or ceilings during the execution of electrical inspections or repairs, restoring the surface to its original finish.A completion & compliance report signed and stamped by a valid electrical wiring licence holder shall be submitted. | Comprehensive electrical safety audit (IS 732), taking necessary corrective action, housekeeping and scrap management of newly renovated Type III & B type buildings. The work must be executed and certified by a valid electrical licence holder.Scope shall include testing of house wiring by IR test, verifying the mechanical and electrical performance of all MCBs, RCBOs, switches, fans, and lamp holders, physical verification of fan hooks for structural integrity, and checking the presence/continuity of the earthing wire in all switchboards and power points. Scope shall also include cleaning of dust/carbon from all electrical components using non-conductive cleaners, systematic dressing and bunching of loose/unorganised wires inside switchboards and Distribution Boards (DBs) using nylon cable ties and proper routing.All redundant openings in MCB DBs, switchboards, and cable entry points shall be closed using dummy plates, cable gland plugs, or appropriate sealing compounds to prevent dust and pest entry. All scrap generated shall be segregated and removed to the designated.The contractor shall also perform necessary civil repairs, including plastering, filling of cracks, and touch-up work for any damages caused to walls or ceilings during the execution of electrical inspections or repairs, restoring the surface to its original finish.A completion & compliance report signed and stamped by a valid electrical wiring licence holder shall be submitted. |
| 42 | Comprehensive electrical safety audit (IS 732), taking necessary corrective action, housekeeping and scrap management of newly renovated Type IV type buildings. The work must be executed and certified by a valid electrical licence holder.Scope shall include testing of house wiring by IR test, verifying the mechanical and electrical performance of all MCBs, RCBOs, switches, fans, and lamp holders, physical verification of fan hooks for structural integrity, and checking the presence/continuity of the earthing wire in all switchboards and power points. Scope shall also include cleaning of dust/carbon from all electrical components using non-conductive cleaners, systematic dressing and bunching of loose/unorganised wires inside switchboards and Distribution Boards (DBs) using nylon cable ties and proper routing.All redundant openings in MCB DBs, switchboards, and cable entry points shall be closed using dummy plates, cable gland plugs, or appropriate sealing compounds to prevent dust and pest entry. All scrap generated shall be segregated and removed to the designated.The contractor shall also perform necessary civil repairs, including plastering, filling of cracks, and touch-up work for any damages caused to walls or ceilings during the execution of electrical inspections or repairs, restoring the surface to its original finish.A completion & compliance report signed and stamped by a valid electrical wiring licence holder shall be submitted. | Comprehensive electrical safety audit (IS 732), taking necessary corrective action, housekeeping and scrap management of newly renovated Type IV type buildings. The work must be executed and certified by a valid electrical licence holder.Scope shall include testing of house wiring by IR test, verifying the mechanical and electrical performance of all MCBs, RCBOs, switches, fans, and lamp holders, physical verification of fan hooks for structural integrity, and checking the presence/continuity of the earthing wire in all switchboards and power points. Scope shall also include cleaning of dust/carbon from all electrical components using non-conductive cleaners, systematic dressing and bunching of loose/unorganised wires inside switchboards and Distribution Boards (DBs) using nylon cable ties and proper routing.All redundant openings in MCB DBs, switchboards, and cable entry points shall be closed using dummy plates, cable gland plugs, or appropriate sealing compounds to prevent dust and pest entry. All scrap generated shall be segregated and removed to the designated.The contractor shall also perform necessary civil repairs, including plastering, filling of cracks, and touch-up work for any damages caused to walls or ceilings during the execution of electrical inspections or repairs, restoring the surface to its original finish.A completion & compliance report signed and stamped by a valid electrical wiring licence holder shall be submitted. |
| 43 | Installation, testing and commissioning of supplied MS meter box of 1200 mm x 850 mm x 250 mm, approximate weight 85 to 100 kg. Scope shall also include termination of 4/3.5 C x 35/70 sq mm Al cable, termination of 6 no service mains, installing departmentally supplied 2 model RCBos, labelling of all MCBs, energy meters, etc. PVC conduits through which service mains are laid shall be terminated with suitable glands. All redundant openings shall be closed. | Installation, testing and commissioning of supplied MS meter box of 1200 mm x 850 mm x 250 mm, approximate weight 85 to 100 kg. Scope shall also include termination of 4/3.5 C x 35/70 sq mm Al cable, termination of 6 no service mains, installing departmentally supplied 2 model RCBos, labelling of all MCBs, energy meters, etc. PVC conduits through which service mains are laid shall be terminated with suitable glands. All redundant openings shall be closed. |
| 44 | Supply, laying/ installingt of high-quality GI flexible pipe in provided wall /tray with OD 50 mm suitable for laying service main. Flexible pipe shall be fixed with suitable clamps as per relevent IS standerds incuding required PVC glands and fixing accesories. make: janson | Supply, laying/ installingt of high-quality GI flexible pipe in provided wall /tray with OD 50 mm suitable for laying service main. Flexible pipe shall be fixed with suitable clamps as per relevent IS standerds incuding required PVC glands and fixing accesories. make: janson |
| 45 | Supply laying and termination of unarmoured single core 16 sq mm AL earthing wire for Meter box/ panel of reputed companies like polycab/filox/KEI etc as per site in charge instruction scope shall incuuding layiing from main earthpit to panel & metar box including crimping of lug & termination the same | Supply laying and termination of unarmoured single core 16 sq mm AL earthing wire for Meter box/ panel of reputed companies like polycab/filox/KEI etc as per site in charge instruction scope shall incuuding layiing from main earthpit to panel & metar box including crimping of lug & termination the same |
| 46 | Supply laying and termination of unarmoured single core 25 sq mm AL earthing wire for Meter box/ panel of reputed companies like polycab/filox/KEI etc as per site in charge instruction scope shall incuuding layiing from main earthpit to panel & metar box including crimping of lug & termination the same | Supply laying and termination of unarmoured single core 25 sq mm AL earthing wire for Meter box/ panel of reputed companies like polycab/filox/KEI etc as per site in charge instruction scope shall incuuding layiing from main earthpit to panel & metar box including crimping of lug & termination the same |
| 47 | Supply laying and termination of armoured single core 35 sq mm AL earthing wire for Meter box/ panel of reputed companies like polycab/filox/KEI etc as per site in charge instruction scope shall incuuding layiing from main earthpit to panel & metar box including crimping of lug & termination the same | Supply laying and termination of armoured single core 35 sq mm AL earthing wire for Meter box/ panel of reputed companies like polycab/filox/KEI etc as per site in charge instruction scope shall incuuding layiing from main earthpit to panel & metar box including crimping of lug & termination the same |
| 48 | Supply, fabrication, and installation of GI perforated-type cable tray of size Size 50 mm width X 50 mm depth X 2500 mm with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. | Supply, fabrication, and installation of GI perforated-type cable tray of size Size 50 mm width X 50 mm depth X 2500 mm with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. |
| 49 | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 150 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 150 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. |
| 50 | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 300 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 300 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. |
| 51 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 25 mm with double locking arrangement with grooves, trunking of size not below 12.5 mm.in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 25 mm with double locking arrangement with grooves, trunking of size not below 12.5 mm.in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 52 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 32 mm with double locking arrangement with grooves, trunking of size not below 12.5 mm in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 32 mm with double locking arrangement with grooves, trunking of size not below 12.5 mm in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 53 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 40 mm with double locking arrangement with grooves, trunking of size not below 12.5 mm. in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 40 mm with double locking arrangement with grooves, trunking of size not below 12.5 mm. in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 54 | Carriage & erection of departmentally supplied ceiling fans/ wall mounting of sizes 48\\" to 56\\" / Exhaust fan & their regulators including outting & threading of down rod and wiring, assembly of fan as required | Carriage & erection of departmentally supplied ceiling fans/ wall mounting of sizes 48\\" to 56\\" / Exhaust fan & their regulators including outting & threading of down rod and wiring, assembly of fan as required |
| 55 | replacing rubber bush/ nut -bolt of ceiling fan (For replacing rubber bush) | replacing rubber bush/ nut -bolt of ceiling fan (For replacing rubber bush) |
| 56 | Supplying and fixing condenser 2 / 1.85/2.25 micro farad for ceiling fan. | Supplying and fixing condenser 2 / 1.85/2.25 micro farad for ceiling fan. |
| 57 | Supply & replacement of wooden /other approved material board 4''x4'' | Supply & replacement of wooden /other approved material board 4''x4'' |
| 58 | Supply & replacement of wooden / other approved board of 4\\" to 7\\" | Supply & replacement of wooden / other approved board of 4\\" to 7\\" |
| 59 | Supply & replacement of wooden / other approved board 8\\" to 10\\" | Supply & replacement of wooden / other approved board 8\\" to 10\\" |
| 60 | Supply & replacement of wooden / other approved board 10\\" x 12\\" | Supply & replacement of wooden / other approved board 10\\" x 12\\" |
| 61 | Supplying and erecting plan pendent type Bakelite lamp holder complete erect at position with necessary length of twin flexible wire (up to 1 mtr.) | Supplying and erecting plan pendent type Bakelite lamp holder complete erect at position with necessary length of twin flexible wire (up to 1 mtr.) |
| 62 | Supply & fixing of Ding-dong bell | Supply & fixing of Ding-dong bell |
| 63 | Carriage& installation including wiring & connections of decorative /industrial type, fluorescent light fittings of 1x40W & 2x40W (Or equivalent departmentally supplied LED Batten) directly on ceiling / wall with T.W round blocks. (Only fittings shall be supplied by RCF other material & hardware shall be supplied by the contractor) | Carriage& installation including wiring & connections of decorative /industrial type, fluorescent light fittings of 1x40W & 2x40W (Or equivalent departmentally supplied LED Batten) directly on ceiling / wall with T.W round blocks. (Only fittings shall be supplied by RCF other material & hardware shall be supplied by the contractor) |
| 64 | Making trench in Hard murum / Tar road of suitable width of 0.9 m deep for laying provided L.T. cable. Half round hume pipe of 150 mm placed length wise on top of the cable all over the run and back filling the excavated earth without stones or hard material and making the surface proper with 15 cms. Crown on the top. (As per IS 1255) (rate per meter) | Making trench in Hard murum / Tar road of suitable width of 0.9 m deep for laying provided L.T. cable. Half round hume pipe of 150 mm placed length wise on top of the cable all over the run and back filling the excavated earth without stones or hard material and making the surface proper with 15 cms. Crown on the top. (As per IS 1255) (rate per meter) |
| 65 | Laying of PVC cable Alu/Cu Armoured/unarmoured all core 1.5 sq mm-10 sq mm on wall/provided trench/on ground/on pole with necessary hardware. | Laying of PVC cable Alu/Cu Armoured/unarmoured all core 1.5 sq mm-10 sq mm on wall/provided trench/on ground/on pole with necessary hardware. |
| 66 | Laying of cable Alu/Cu Armoured/unarmoured all core 16 sq mm-35 sq mm on wall/provided trench/on ground/on pole with necessary hardware | Laying of cable Alu/Cu Armoured/unarmoured all core 16 sq mm-35 sq mm on wall/provided trench/on ground/on pole with necessary hardware |
| 67 | Laying of cable Alu/Cu Armoured/unarmoured all core 50 sq mm- 120 sq mm on wall/provided trench/on ground/on pole with necessary hardware | Laying of cable Alu/Cu Armoured/unarmoured all core 50 sq mm- 120 sq mm on wall/provided trench/on ground/on pole with necessary hardware |
| 68 | Dismantling the existing above gound cable of all types & sizes | Dismantling the existing above gound cable of all types & sizes |
| 69 | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing & accessories and suitable clamps duly erected and connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing & accessories and suitable clamps duly erected and connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable |
| 70 | Providing & erecting epoxy straight through joint for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 25 Sq.mm to 50 Sq.mm cable | Providing & erecting epoxy straight through joint for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 25 Sq.mm to 50 Sq.mm cable |
| 71 | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 70 Sq.mm to 185 Sq.mm cable | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 70 Sq.mm to 185 Sq.mm cable |
| 72 | Installation of HPSV/HPMV/LED streetlight fitting on 6' pipes including bending, clamping the poles & wiring as required. ( Fittings, lamps, pipe shall be supplied by RCF while remaining material & hardware shall be supplied by the contractor.) | Installation of HPSV/HPMV/LED streetlight fitting on 6' pipes including bending, clamping the poles & wiring as required. ( Fittings, lamps, pipe shall be supplied by RCF while remaining material & hardware shall be supplied by the contractor.) |
| 73 | Erection of departmentally supplied 32 / 63 ICTPN /SDF switch 3 phase, 400 V with required materials including connection & earthing the same. | Erection of departmentally supplied 32 / 63 ICTPN /SDF switch 3 phase, 400 V with required materials including connection & earthing the same. |
| 74 | Erection of dept.supplied 100/125/200/300 /400 A ICTPN switch/geysor/motor starter on the exiting frame including termination of the cable, connection & earthing the same. | Erection of dept.supplied 100/125/200/300 /400 A ICTPN switch/geysor/motor starter on the exiting frame including termination of the cable, connection & earthing the same. |
| 75 | Supply of PVC insulated Cu conductor (flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 core 1.5 SQMM. Make : Polycab / Finolex / KEI | Supply of PVC insulated Cu conductor (flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 core 1.5 SQMM. Make : Polycab / Finolex / KEI |
| 76 | Supply & erecting acrylic sheet of size 3mm thick to be used for covering CRCA sheet boxes etc including cutting, drilling, & oasting or fixing with nut bolts/screw complete | Supply & erecting acrylic sheet of size 3mm thick to be used for covering CRCA sheet boxes etc including cutting, drilling, & oasting or fixing with nut bolts/screw complete |
| 77 | Providing & fixing of FRP street light junction box of IP 66 or above, RYBN connection studs or 6\\"x4\\"x4\\" street light metal pole boxes | Providing & fixing of FRP street light junction box of IP 66 or above, RYBN connection studs or 6\\"x4\\"x4\\" street light metal pole boxes |
| 78 | Termination of 1.1 KV grade PVC electrical power Al / Cu armoured cable of following size. The tools / tackles shall be arranged by the bidder. Supply of Nickle plated Brass cable glands & Al / Cu lugs shall be in bidders scope. | Termination of 1.1 KV grade PVC electrical power Al / Cu armoured cable of following size. The tools / tackles shall be arranged by the bidder. Supply of Nickle plated Brass cable glands & Al / Cu lugs shall be in bidders scope. |
| 79 | Supplying & Erecting modular type switch 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type switch 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 80 | Supplying & Erecting modular type bell-push 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type bell-push 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 81 | Supplying & Erecting modular type 3 pin 6A socket ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type 3 pin 6A socket ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 82 | Supplying & Erecting modular type 3 pin 6A / 16A Combined Unit ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type 3 pin 6A / 16A Combined Unit ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 83 | Supplying & Erecting modular type Electronic dimmer / step type regulator, two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type Electronic dimmer / step type regulator, two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 84 | Repairs / rewinding of celing fan of 1200 mm sweep | Repairs / rewinding of celing fan of 1200 mm sweep |
| 85 | Replacement of bearings of celing fan with 1200mm sweep | Replacement of bearings of celing fan with 1200mm sweep |
| 86 | Point wiring in concealed manner with PVC conduit. Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FR PVC insulated copper conductor single core cable in concealed manner in heavy duty PVC conduit, with modular switch, modular plate, suitable MS box, ceiling rose and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (from Switch/ taping to light point/ fan point/ exhaust fan point/ call bell point). Pref Make : Polycab / Finolex/KEI | Point wiring in concealed manner with PVC conduit. Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FR PVC insulated copper conductor single core cable in concealed manner in heavy duty PVC conduit, with modular switch, modular plate, suitable MS box, ceiling rose and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (from Switch/ taping to light point/ fan point/ exhaust fan point/ call bell point). Pref Make : Polycab / Finolex/KEI |
| 87 | PVC conduit along with accessories including cutting the wall and making good the same for consealed wiring as wall and making good the same for concealed wiring as required for the following items | PVC conduit along with accessories including cutting the wall and making good the same for consealed wiring as wall and making good the same for concealed wiring as required for the following items |
| 88 | FR PVC insulated copper conductor, single core cable in the existing concealed PVC conduit / open conduit as required for the following. Pref Make : Polycab / Finolex/KEI | FR PVC insulated copper conductor, single core cable in the existing concealed PVC conduit / open conduit as required for the following. Pref Make : Polycab / Finolex/KEI |
| 89 | Open Point Wiring with wires of polycab / finolex/ KEI and suitable casing caping or conduite. No extra payment will not be made for switches, celing rose etc, which form part of point wiring. (Light point / Plug Point ). Wires shall be of mentioned make | Open Point Wiring with wires of polycab / finolex/ KEI and suitable casing caping or conduite. No extra payment will not be made for switches, celing rose etc, which form part of point wiring. (Light point / Plug Point ). Wires shall be of mentioned make |
| 90 | Modules , PVC Box along with modular base & cover plate for modular switches in recess etc as required for the following items. | Modules , PVC Box along with modular base & cover plate for modular switches in recess etc as required for the following items. |
| 91 | IP43 SPN & TPN Distribution board with metal door (Preferably of double door) of various sizes on wall/ Column/ floor mounting, with detachable gland plate, terminal connectors and other required hardware & fasteners. DB shall be designed for incoming MCB & no. of outgoing MCB as per requirement or no. of outgoing way (Cost of the DBs will be without MCB, MCCB & other acessories. | IP43 SPN & TPN Distribution board with metal door (Preferably of double door) of various sizes on wall/ Column/ floor mounting, with detachable gland plate, terminal connectors and other required hardware & fasteners. DB shall be designed for incoming MCB & no. of outgoing MCB as per requirement or no. of outgoing way (Cost of the DBs will be without MCB, MCCB & other acessories. |
| 92 | Fixing of 2'X2' LED / Mirror optic fiting with independent support. Removal of existing 2' X 2' 4X18W T/L/ LED fitting from falls celing with disconnection & determination of connections. Supply and fixing of 4 nos of \\"J\\" screw type hooks / angle fasteners on the celing & GI wire for fixing of fittings. Installation of removed above said fittings on newly installed \\"J\\" hooks / angle fastener with GI wire up to falls celing & termination to existing connection. | Fixing of 2'X2' LED / Mirror optic fiting with independent support. Removal of existing 2' X 2' 4X18W T/L/ LED fitting from falls celing with disconnection & determination of connections. Supply and fixing of 4 nos of \\"J\\" screw type hooks / angle fasteners on the celing & GI wire for fixing of fittings. Installation of removed above said fittings on newly installed \\"J\\" hooks / angle fastener with GI wire up to falls celing & termination to existing connection. |
| 93 | Normalising Road after cable laying: Nominal mix of 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size. | Normalising Road after cable laying: Nominal mix of 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size. |
| 94 | Street light fitting's/Post top lantern fitting, glass and reflector removal, cleaning and re fixing | Street light fitting's/Post top lantern fitting, glass and reflector removal, cleaning and re fixing |
| 95 | Supply and erection of socket - step type electronic regulator | Supply and erection of socket - step type electronic regulator |
| 96 | Supply and erection of 8 - 9W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. | Supply and erection of 8 - 9W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. |
| 97 | Supply and erection of 12 - 15W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro | Supply and erection of 12 - 15W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro |
| 98 | Supply and erection of LED tube light batten of 2ft of make Havells/Crompton/ Surya/Polycab/Philips/Wipro | Supply and erection of LED tube light batten of 2ft of make Havells/Crompton/ Surya/Polycab/Philips/Wipro |
| 99 | Making trench in soft soil with a width up to 2 ft, depth of 4feet. Back filling shall also be included. | Making trench in soft soil with a width up to 2 ft, depth of 4feet. Back filling shall also be included. |
| 100 | Making trench in hard soil with a width up to 2 ft, depth of 4feet | Making trench in hard soil with a width up to 2 ft, depth of 4feet |
| 101 | Laying of bricks on cable in lenth wise. | Laying of bricks on cable in lenth wise. |
| 102 | Laying of full hume pipe of size six inche | Laying of full hume pipe of size six inche |
| 103 | Supply of suitable MS angles and fabrication of the same | Supply of suitable MS angles and fabrication of the same |
| 104 | Supply of suitable MS I - channel and fabrication of the same | Supply of suitable MS I - channel and fabrication of the same |
| 105 | Supply and laying of GI Earthing pattie with suitable clamps. Width : 25mm to 100 mm& thickness : 3 mm - 10mm | Supply and laying of GI Earthing pattie with suitable clamps. Width : 25mm to 100 mm& thickness : 3 mm - 10mm |
| 106 | Supply on hiring basis, installation of 100 to 150 LED fittings with required wires / cables | Supply on hiring basis, installation of 100 to 150 LED fittings with required wires / cables |
| 107 | Replacement of existing 5 / 6 A switch / Bell push piano switch with new Anchor / Legrand/ L & T make 5 / 6 A switch. Cost shall include replacement of old switch also | Replacement of existing 5 / 6 A switch / Bell push piano switch with new Anchor / Legrand/ L & T make 5 / 6 A switch. Cost shall include replacement of old switch also |
| 108 | Replacement of existing 5 / 6A plug with new Anchor / Legrand/ L & T make 5A Plug. Cost shall include replacement of old plug also | Replacement of existing 5 / 6A plug with new Anchor / Legrand/ L & T make 5A Plug. Cost shall include replacement of old plug also |
| 109 | Supply. Installation and commissioning of 63A, 3 pole isolator of Make L & T, Legrand/Anchor/ Hager | Supply. Installation and commissioning of 63A, 3 pole isolator of Make L & T, Legrand/Anchor/ Hager |
| 110 | Supply, installation and commissioning of 16 A modular switch of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 16 A modular switch of make Hifi / L & T/Havells / Roma |
| 111 | Supply, installation and commissioning of 16 A modular socket / 16-5A combination modular socket of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 16 A modular socket / 16-5A combination modular socket of make Hifi / L & T/Havells / Roma |
| 112 | Supply, installation and commissioning of 25 A modular switch of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 25 A modular switch of make Hifi / L & T/Havells / Roma |
| 113 | Supply, installation and commissioning of 25 A modular socket of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 25 A modular socket of make Hifi / L & T/Havells / Roma |
| 114 | Industrial plug top for AC Box of rating 16A suitable for existing AC Box | Industrial plug top for AC Box of rating 16A suitable for existing AC Box |
| 115 | Supply, installation and commissioning of L&T HN fuses-63 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-63 A, Size 000 |
| 116 | Supply, installation and commissioning of L&T HN fuses-80 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-80 A, Size 000 |
| 117 | Supply, installation and commissioning of L&T HN fuses-125 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-125 A, Size 000 |
| 118 | Supply, installation and commissioning of L&T make cylindrical type fuse link HF63A. | Supply, installation and commissioning of L&T make cylindrical type fuse link HF63A. |
| 119 | Supply, installation and commissioning of 40 - 63 A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supply, installation and commissioning of 40 - 63 A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 120 | Supply, installation and commissioning of up to 32A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supply, installation and commissioning of up to 32A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 121 | Supply, installation and commissioning of 63A, three pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager, C&S Electric | Supply, installation and commissioning of 63A, three pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager, C&S Electric |
| 122 | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 16 - 32-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 16 - 32-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 123 | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 40 amp to 63-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 40 amp to 63-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 124 | Supply and fabrication of class C GI pipe of different OD (Suitable to base fittings) to streetlight poles, garden light poles etc. Scope shall also include painting of 1 coat fprime with 2 coat of silver colour, | Supply and fabrication of class C GI pipe of different OD (Suitable to base fittings) to streetlight poles, garden light poles etc. Scope shall also include painting of 1 coat fprime with 2 coat of silver colour, |
| 125 | Supply, installation and commissioning of GI busbar (hot dip) for earthing connection. (SIZE: 34 mm (L) x 50 mm (W) x 6 mm) The busbar shall have six no holes and be provided with suitable stainless steel nut bolts for taping connections. | Supply, installation and commissioning of GI busbar (hot dip) for earthing connection. (SIZE: 34 mm (L) x 50 mm (W) x 6 mm) The busbar shall have six no holes and be provided with suitable stainless steel nut bolts for taping connections. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail