| Sl. No. | Item Description |
| 1 | CIVIL WORK |
| 2 | 2.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil |
| 3 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 4 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 5 | 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at siteNe |
| 6 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 8 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 9 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 10 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 11 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 12 | 5.9.7Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 13 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or moree |
| 14 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 15 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 16 | 5.9.16.1Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 17 | 50.6.1.8Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etccomplete |
| 18 | 22.5Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry. |
| 19 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 20 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost ofmaterials, labour charges etc complete |
| 21 | 9.48.1Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to steel windows by welding |
| 22 | 11.49.2Providing and laying Vitrified tiles in floor with different sizes (thickness to bespecified by the manufacturer), with water absorption less than 0.08% andconforming to IS : 15622, of approved brand & manufacturer, in all colours andshade, laid with cement based high polymer modified quick set tile adhesive (waterbased) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tiles 600x600mm |
| 23 | 11.46.2Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 24 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | 11.20.1Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 26 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 27 | 5.30Add for plaster drip course / groove in plastered surface or moulding to R.C.C.projections. |
| 28 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 29 | 21.1.2.2For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 30 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 31 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 32 | 9.117.1Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wall thickness2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized bracketsand stainless steel screws, joints mitred and plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer's specification and direction of Engineer-in-chargeExtruded sectionprofile size 48x40 mm |
| 33 | 9.118.2Providing and fixing to existing door frames30 mm thick factory made PolyvinylChloride (PVC) door shutter made of styles and rails of a uPVC hollow section ofsize 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorativemoulding edging on one side. The styles and rails mitred and joint at the corners bymeans of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. Thelock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm(± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanisedM.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel ofsize not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm)wall thickness. The panels filled vertically and tie bar at two places by insertinghorizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, completeas per manufacturer's specification and direction of Engineer-in-charge. |
| 34 | 10.5.2Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using flats30x6 mm for diagonal braces and central cross piece |
| 35 | 22.23.2Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerin charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 36 | 13.26Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete |
| 37 | 13.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 38 | 13.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture |
| 39 | 16.68Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour and patternover and including 50 mm thick compacted bed of coarse sand, filling the joints withfine sand etc. all complete as per the direction of Engineer-in-charge. |
| 40 | OD398633/2025-2026Supplying and fixing steel pressed single panelled door of size 120*205cm with steelframes using superior quality GI sections made of tata steel |
| 41 | OD398630/2025-2026Providing and fixing Roller blinds curtains using good quality materials, fitted to thewall withnecessary fittings. all complete as per direction of Engineer in-charge |
| 42 | OD398632/2025-2026Providing and fixing of acrylic name board with printed acrylic board .all work as perthe direction of engineer in charge |
| 43 | OD398631/2025-2026Supply and fixing of name board of size 3.60*0.60m made of ACP panels supportedover GI frame work |
| 44 | FURNISHING WORK |
| 45 | OD398627/2025-2026Providing and fixing staff table of size 2.00x0.70x0.75m made with marine plywood18mm thick over fixing 3mm thick teakwood veneer, 1mm thick mica lamination oninside and providing onedraw ,one cupboard,key board including all other fittings all cost of materials alllabour charges etc complete.. |
| 46 | OD398625/2025-2026Providing and fixing staff table of size 1.80x0.70x0.75m made with marine plywood18mm thickover fixing 3mm thick teakwood veneer, 1mm thick mica lamination on inside andproviding one draw ,one cupboard,key board including all other fittings all cost of materials alllabour charges etccomplete. |
| 47 | OD398626/2025-2026providing and supplying staff revolving chair |
| 48 | OD398629/2025-2026Supplying high back executive chair Nylon base multi-function mechanism, withcushion and leather finish, including transporting charges and all other loading andhandling charges. |
| 49 | OD398628/2025-2026Supplying of Public / Waiting Seating: Three seater. ( 35 KG - GW ) Gauge : 14”, Dimension: 173cm * 64cm * 89cm. Seat dimension : 43cm * 51cm * 49cm.Seat & Back: 1.5mm Perforated powder coated. Beam: 2.0mm mild steelPowder coated |
| 50 | OD398624/2025-2026Supply of Godrej steel shelf of size 1.00 x 0.50 x2.10m, 16 gauge , made of goodquality sheet applying suitable paints all complete as per the direction of engineer-in charge |
| 51 | PLUMBING AND SANITARY FITTINGS |
| 52 | 17.3.1Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flushbend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement withspecials of standard make and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting and making good thewalls and floors wherever required :W.C. pan with ISI marked white solid plastic seatand lid |
| 53 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 54 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 55 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-in charge. |
| 56 | 50.17.1.1Supplying and fixing Stainless steel soap dish including cost of materials and labourcharges etc complete as per the direction of site Engineer-in-charge. |
| 57 | 17.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers |
| 58 | 50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2 |
| 59 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend. |
| 60 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 61 | 50.18.9.13.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 25 mmdia 12 Kgf/ cm2- External work- exposed on wall dia 10 Kgf/cm2 - External work- Exposed on wall |
| 62 | 50.18.9.14.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 32 mml dia 10 Kgf/cm2 - External work- Exposed on wall |
| 63 | 50.18.9.17.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 mspacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 63 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 64 | 50.18.9.20.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bendl |
| 65 | 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipesincluding jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 66 | 18.54.4Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominalbore, 90 mm long, weighing not less than 93 gms |
| 67 | ELECTRICAL WORKS |
| 68 | 90.1.1.1Supply and laying medium gauge PVC conduit of the following sizes conforming toIS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying& fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 69 | 90.2.2.1Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (Group B/ RoHS compliant modular accessories).Single Control light pointwith 6A, plate ceiling rose - Short point |
| 70 | 1.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 71 | 90.2.2.3Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (Group B/ RoHS compliant modular accessories).Single control light pointwithout ceiling rose - Short point |
| 72 | 90.2.2.4Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (Group B/ RoHS compliant modular accessories).Single control ceiling fanpoint with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. -Short point |
| 73 | 90.2.2.5Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (Group B/ RoHS compliant modular accessories).Call bell point with 6 Abell push at one end and 6 A, 3 plate ceiling rose at other end - Short point |
| 74 | 90.2.2.6 Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (Group B/ RoHS compliant modular accessories).Combined plug point with6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that oflight points |
| 75 | 90.2.2.7Supply and wiring points according to IS 732-1989 through the existing conduit with1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with No.14SWG bare copper,required quantity of copper earth socket, brass bolt and nutcrimping/ soldering etc complete with suitable size modular type metal switch boxes,modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall bedrawn and fixed along the periphery of the box using suitable ties, tie mounts etc asrequired. (Group B/ RoHS compliant modular accessories).Independent plug - Shortpoints |
| 76 | 90.3.18.2Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bentto shape / cut and welded to shape and fixing the same to wall / parapet using clampsas noted along with each size, painting with 2 coats of synthetic enamel paint over acoat of zinc chromate primer, making good the damages, colour washing etc asrequired.32 mm dia with HG company fabricated clamps |
| 77 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 78 | 90.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell onexisting M.S. box and giving connections with required length of 3 core, 16 / 0.20mm650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wireconforming to relevant ISS or with the extended original wiring, earthing the MS boxand making good the surface as required.Ding dong bell |
| 79 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required20 mm |
| 80 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator) |
| 81 | 90.10.3.14Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )25A SP switchwith indicator |
| 82 | 90.10.3.32Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )25A 3 pinplug top with indicator |
| 83 | 90.10.3.33Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )25A 3pinShuttered socket |
| 84 | 90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED streetlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coatedhousing,acrylic cover complete with THD less than 10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Drivercompartment should be seperatly accessible for maintenance (LM 79&80 certificatesfrom NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 85 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 86 | 90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG) |
| 87 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 88 | 2.3.1Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 89 | 2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 90 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 91 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 92 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40 commissioning etc. as required.40 ampsamps |
| 93 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and |
| 94 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x1.5 sq. mm |
| 95 | 1.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x1.5 sq. mm |
| 96 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x2.5 sq. mm |
| 97 | 1.17.13Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x2.5 sq. mm |
| 98 | 1.17.20Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x4 sq. mm |
| 99 | 1.17.29Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x6 sq. mm |
| 100 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 101 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet |
| 102 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switchbox excluding modular plate as required. |
| 103 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 104 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For lightplugs to be used in non residential buildings). |
| 105 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 106 | OD398610/2025-2026Supply ,installation of 32 A Kit cat fuse unit made by porcelain/ ceramic |
| 107 | OD398618/2025-2026Providing and fixing of service pipe (32 mm) |
| 108 | OD398612/2025-2026Supply and fixing 200mm plastic shade on existing batten/angle/pendant/bracketfittings as required |
| 109 | OD398615/2025-2026Supply and fixing 9 w LED Bulb on existing lamp holder B22 |
| 110 | OD398613/2025-2026Supply and providing suitable iron hook grouted on the ceiling for hooking the ceilingfan |
| 111 | OD398622/2025-2026Supply, conveyance, installation, testing and commissioning of the following sizes ofexhaust fans in the existing opening, fixing necessary bolt and nuts, making good thedamages etc. as required including giving connections with required length of24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. -200 mm, single phase light duty exhaust fan inPlastic frame ( Light duty exhaust fan) |
| 112 | OD398616/2025-2026Fabrication, supply and installation of wall mounting powder coated open type GImeter box of following size suitable for fixing single phase energy meter, Kit cat fuse,Neutral link etc. hinged door construction, knock out for cable entry etc. as required |
| 113 | 90.6.6.2Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 corecopper conductor flat cable for submersible pump motor conforming to IS 694 part I1990 as required including giving necessary connections of the following sizes.2.50sq mm |
| 114 | OD398614/2025-2026Supply installation testing and commissioning of Single Phase DOL starters for 0.25to 3 HP motor |
| 115 | OD398617/2025-2026Supply installation testing and commissioning of Water Purifier wit the followingspecifications (12 L RO + UV + TDS + Controller) |
| 116 | OD398619/2025-2026Supply Installation Testing and Commissioning of ISO / BIS Certified IGBTtechnology based 2.5KV Online UPS/Inverter with minimum 3 years on-sitewaaranty and having the following minimum specifications. 1. Output:230V+1%50Hz sine wave single phase. 2. Input: 170V to 270V Hz AC 3. Rating: 2.5KVA, 4.Backup time: Minimum 2 Hrs, on full load, 5. Efficiency: 90% or Higher. 6. Batterybank: 150VAH/above(2nos) or Higher tubular battery with minimum 3 Yearswarranty with suitable battery rack. 7. Protection: Over load, short circuit, batteryreverse polarity, input voltage below or above the specified range over discharge orcharge of battery, Accepted model: hykon or equivalent brand with betterspecification. |
| 117 | OD398620/2025-2026Supply, conveyance, installation and testing of 80cm(32 inch) HD Ready Led TV ofthe following sizesusing standard accessories including and providing wall mountingstands. Screen Resolution 1366x768- HD and 2 HDMI & 1 USB Ports, workingon 230V/240V single phase A/c as required |
| 118 | OD398611/2025-2026SUPPLY AND INSTALLATION OF SET TOP BOX |
| 119 | OD398623/2025-2026Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. ( but with charcoal/ coke and salt) as required |
| 120 | OD398621/2025-2026Supply & installation of 1200mm, 20W LED Tube and giving connections withrequired length of 16/0.20mm 3 core copper conductor flex wire . |
| 121 | NETWORK WIRING AND INSTALLATION |
| 122 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required20 mm |
| 123 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 124 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable |
| 125 | OD398643/2025-2026Providing and fixing of 16-Port Gigabit Unmanaged Switch.( D-Link DGS-1016A orequivalent ) |
| 126 | OD398639/2025-2026Supply and fixing/crimping modular CAT6 RJ45 Data socket on the existing modularplate or patchpanel.(RJ 45 Data socket without face plate) |
| 127 | OD398644/2025-2026supply installation testing and commissioning of following sizes of Wall mountNetwork Rack. 4U 350D( But without server, switches cooling fans etc.) |
| 128 | OD398636/2025-2026supply installation testing and commissioning of CAT6 UTP 24-Port Network Panel Desktop 19-Inch Rack Integration Server Mounting Shielded.24 Port laded PatchPanel (D-Link or equivalent) as required. |
| 129 | OD398634/2025-2026Supply Installation Testing and Commissioning of Wireless AC1200, Dual-Band andceiling mount Gigabit Access Point (TP-Link EAP225 AC1200 Wireless MU-MIMOGigabit Indoor/Outdoor Access Point/ Equivalent) |
| 130 | OD398637/2025-2026Supply and stackingg of Cat-6 Patch Cord -2m |
| 131 | OD398640/2025-2026Supply and stacking of Cat-6 Patch Cord Cable-1mtr |
| 132 | OD398642/2025-2026Supply and stacking of Cat-6 Patch Cord Cable- 0.5 mtr |
| 133 | OD398641/2025-2026Supply, conveyance, installation and testing of Cooling Fan for Incubator, Fan forComputer Server 120 *120 * 38mm, 4.7 Inch Black |
| 134 | OD398638/2025-2026Supply and fixing/crimping modular CAT6 RJ45 Data socket on the existing modularplate or patch panel.(RJ 45 Data socket without face plate) |
| 135 | OD398635/2025-2026Supply conveyance and installation of PoE injector. (Tenda TE-POE30G-AT GigabitPoE Injector or equivalent)N Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail