| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group A |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a) 1 x 1.5 sq. mm |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a) 2 x 1.5 sq. mm |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a) 3 x 1.5 sq. mm |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a) 4 x 1.5 sq. mm |
| 7 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 4 sq. mm |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 x 6 sq. mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 3 pin 5/6 A socket outlet |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 A switch |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 6 pin 15/16 A socket outlet |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Bell push |
| 16 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 17 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 18 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 19 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 Module (75mmX75mm) |
| 20 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 3 Module (100mmX75mm) |
| 21 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 4 Module (125mmX75mm) |
| 22 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 6 Module (200mmX75mm) |
| 23 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 8 Module (125mmX125mm) |
| 24 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 12 Module (200mmX150mm) |
| 25 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 26 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 12 way, Double door |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.a) Single pole |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.a) Double pole |
| 30 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 31 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 32 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 33 | Dismentling and reinstallation of 1.5 Ton split type air conditioner on the existing wall surface including refilling of gas as per requirement etc as required |
| 34 | Supplying and fixing of 300 mm sweep, 1400 rpm metal body double ball bearing exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply with self opening lovers/shutters in the existing wall surface including connections etc. as required. Make Havells/ CG/Usha/ Orient/ Bajaj |
| 35 | Providing and fixing of 20 watt LED 6500 K batten Decorative slim mushroom /square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficientetc. as required including making connection etc. as required directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required.Make Kolors/ Havells/ Crompton/Philips |
| 36 | Providing and fixing of 30 W LED Street Light, 6500K colour temp,power factor >0.9 beam angle 120 degree, IP66 protection product code LHEXAMP7PN6K030 on the existing surface including connections,testing etc as required make Kolors/Havells/ Crompton/ Wipro/Surya or as per direction of engineer in charge. Please Enable Macros to View BoQ information |