| 1 | Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC casing caping fixed on surface of walls conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-(a) One light / Fan / bell point controlled by one 5 Amps switch one way |
| 2 | Supply and fix Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge. |
| 3 | M&L sub main wiring and provide new submain wiring with 2 runs of 1.5 Sqmm single core PVC insulated, unsheathed, multi stranded copper conductor and one single core 1.5 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including PVC casing caping fixed surface on walls in walls etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 1.5 Sqmm cable , one run 1.5 Sqmm cable and one run of PVC casing caping shall be measured as one unit length) . |
| 4 | Supply ,install ,testing & comissioning AMF panel suitable for 40 KVA DG set installed at tech area and Raksh Nagar Kirloskar DG set Model No KG1 40WS including suitable auxillary contactor- part No TA-113001003,Suitable MCCB- part No TA -113001033,bus bar - part no Oth0703,AMF control-part No TS9912,control fuse fitting part No Oth1012,Control relay - part No Oth1009 ,CT part No Oth1010,Battery charger- part No TSS1001,Hooter part No Oth1022,Terminal Control-Part No TER-0002, auto manual selector switch - part No Oth1003,multifunctional meter part No TA-113000885,Emergency stop,indication lamp,DC voltmeter/Ammeter voltmeter,suitable MCBs ,etc mounted inside CPRI approved cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick CRCA sheet with separate locking arrangement, duly painted with epoxy powder coated over a coat of red oxide primer, factory made, cubical type, double door hinged type, both side openable, air fins for ventilation ,manufactured/approved by Cummins India Ltd/Kirloskar Gen set,mounted on suitable size ISMA with adequate clearance from ground ,fixed in PCC type C1 (1:3:6) with 20 mm aggregates, complete all as specified & as directed by Engineer-In-Charge |
| 5 | Material and labour Hermetically sealed single leaf led door shutters with hydraulic mechanism lined with 2mm Lead including frames and skeleton of shutter made up of using profile sections 100 mm x 50 mm with 1.2 mm thick Gl powder coating, 45 mm thick shutter using 0.8 mm thick GI powder coated sheets sealed with PUF insulation of 40 kg/sqm density and using 2 mm thick lead sheet embedded in door leaf and door frame and door frame of section all as per manufacturers instruction with following accessories with each leaf (a) one number standard arm door closure TS-68 (Make - Dorma or equivalent). (b) stainless steel D type handle one pair. (c) 4 number SS ball bearing hinges of size 114 mm x 101 mm x 3.5 mm (Make - Dorma or equivalent). (d) one side key operated locking arrangement complete all as specified and directed by Engineer in Charge. Make :- Lead Door Western India Electro Medical Systems Pvt Ltd (WIESPL) or Equivalent Note: 1. rate shall be inclusive of supply, installation, transportation and minimum two year guarantee of led door shutters. 2. Contractor shall visit site before qouting tender. Please Enable Macros to View BoQ information |