| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital pattern roof covering all as specified and directed. |
| 2 | S&F Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 3 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with seif tapping screws complete all as specified and as directed. |
| 4 | Dismantling of wall and ceiling boards( fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets all as specified. |
| 5 | S&F false ceiling with powder coated exposed GI grid suspension (E-Grid T-2430 oe equivalent load carrying capacity with mid span deflection not exc . 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long and wall angle. The main runners to be placed @1200mm, the cross Tee 1200mm will be inserted in the pre-cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross tees 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. suspensior system (Grid) made out of GI sheet main Tee of size 23.5mmX38.5mmX0.36mm and cross tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmX19mmX0.36mm. Grid of modular size 600mmX600mm shall be supported by 4mm dia G.I wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200kg/Cum) of size 595mmX595mm, confirming IS 14862 & tYPE III of ISO 8336, tests as per AS 1530 part 3 & BS-476 Part 4,5,6&8 complete all as per manufacturer's instruction. (Make : Everest or equivalent as approved by GE) |
| 6 | Demolition of brickwork or stone/boulder masonry built in cement mortor including ashlar facings, dressed stonework and precast concrete articles and precast concrete block walling all as specified. |
| 7 | M&L precast cement concrete type C1 , (1:3:6) (20mm graded aggregate) block masonry with solid blocks, exc.10 cm in width and setting in mortar and setting in cement mortar in (1:6) complete all as specified and directed. |
| 8 | M&L Reinforced cement concrete (nominal mix) in type B-1 (1:2:4) (20mm graded aggregate) as in beams cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 9 | Formwork to sides and soffits of floor or roof beams,beam hunchings, girders ,bressummers,lintels, cantilevers,shelves including supports, overhangs, etc., also splays between floors and beams of fair finished surfaces of concrete complete all as specified. |
| 10 | M&L mild steel TMT Bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less that 0.90 mm dia or securing with chips complete all as specified and directed. |
| 11 | All as per Sl item No. 10 above but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders. |
| 12 | M&L 15mm thick rendering on fair faces of brick work or concrete ssurfaces in cement plaster (1:6) and finished even and smooth (without using extra cement) complete all as specified. |
| 13 | M&L 20mm thick rendering on fair faces of brick work or concrete ssurfaces in cement plaster (1:4) mixed with water proofing compound and finished even and smooth (without using extra cement) complete all as specified. |
| 14 | Supply only integral water proofing compound all as specified. |
| 15 | M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting as priming coat including a thick layer of wall care putty (Birla white or equivalent) complete all as specified and directed. |
| 16 | M&L Preparation of plastered surfaces of walls and applying two coats of cement base paint over a coat of chalk whiting complete all as specified. |
| 17 | Taking down chowkats or frames n.exc 1.5 sq.m each with shutters (without taking off shutters from the frames) all as specified and as directed. |
| 18 | Taking down chowkats or frames exc 1.5 sq.m but n exc 4 sq.m each with shutters (without taking off shutters from the frames) all as specified and as directed. |
| 19 | S&F Pressed steel frames for doors size 165 x 60mm with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 20 | S&F 35mm thick second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified. |
| 21 | S & F 30mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified. |
| 22 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 23 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed. |
| 24 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified. |
| 25 | S&F 3mm thick sheet glass, oridinary quality and glazing with oil putty in square n etc 0.5 sqm in each pane complete all as specified. |
| 26 | S & F Galvanised wire cloth, 0.63 mm nominal dia of wire and average width of aperature 1.4mm and fixed with tinted tacks or galvanised wire staples complete all as specified and directed. |
| 27 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 28 | S&F Extruded aluminium alloy handles 150mm long, fabricated type, anodised complete all as specified. |
| 29 | S&F Aluminium anodised, barrel tower bolts 200mm long of extruded section and fixed complete all as specified. |
| 30 | M&L Preparation and applying two coat of synthetic enamel paint over one coat of pink primer on new wooden surfaces, of any description, over 10cm width or girth not other wise described. |
| 31 | M&L Preparation and applying two coat of synthetic enamel paint over one coat of red oxide primer on new steel surfaces, of any description, over 10cm width or girth not other wise described. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 33 | M&L coloured joint free non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed bed or bedding layer cement plaster (1:6) complete all as specified and as directed. |
| 34 | M&L Glazed coloured ceramic tiles in vertical surface 300x200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15mm backing layer cement plaster (1:3) complete all as specified and as directed. |
| 35 | S&F in repair anodised aluminium alloy harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 36 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 37 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc . Confirming -Fe-410W (Gde E- 250) quality A complete all as specified and directed. |
| 38 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed. |
| 39 | M&L 75mm thick cement concrete type C-2, (1:3:6) (40mm graded aggregate) as in path, plinth protection,etc., complete all as specified and as directed. |
| 40 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and directed. |
| 41 | M&L for Cement concrete type C2 (1:3:6) (40mm graded aggregate) in surface channels and drains complete all as specified and directed. |
| 42 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 43 | Disconnection and taking down distribution boards, switch fuse unit, enclosure for MCB/MCB Box including MCB's of any type and size and keeping aside for reuse of serviceable one. |
| 44 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly for the following :- make : Polycab/Havells/RR Cables/KEI |
| 45 | All as per item No 44 here – in – before but for One 3 pin socket outlet, 5 Amps, independent, withcables 1.5 sq. mm size. |
| 46 | All as per item No 44 here – in – before but for One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size. |
| 47 | All as per item No 44 here – in – before but for One 3 pin socket outlet, 15 Amps, independent, with cables 2.5 sq. mm size. |
| 48 | Supply and fix Switch piano, flush type single pole, one way 6 Amp complete all as specified and as directed. |
| 49 | Supply & Fixing in repair ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed. |
| 50 | Supply and fix switch socket combination 2 in 1, 6A flush type complete all as specified and as directed. |
| 51 | Supply and fix switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal complete all as specified and as directed. |
| 52 | Supply and fixing Switch socket combination 6A/16A, 5 in 1, flush type all as specified and as directed. |
| 53 | Supply and fixing in repair Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 54 | S&F in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 55 | S & F in LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 12 W complete all as directed. |
| 56 | S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC. |
| 57 | Supply and fixing MCB Single pole and neutral 40 Amps capacity 10 KA 240 Volts 50 HZ, 'C' curve. Make : Legrand or equivalent in Siemens/Schneider. |
| 58 | Supply and fix MCB single pole (SP), 10 kA of 6 -32 Amps capacity 240 Volts, 'C' curve. |
| 59 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 60 | S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 61 | S & F decorative wall lamp / wall light globe type including all connection and fixing in wall complete all as specified and directed. |
| 62 | M&L for Earthing in repairs complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1 : 3 : 6) type C-1 , 50 mm thick pre cast RCC (1 : 2 : 4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed. |
| 63 | M&L Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 20 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the concealed to wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. [NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length] |
| 64 | M&L Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 20 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the concealed to wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. [NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length] |
| 65 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in- Charge. |
| 66 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ loose soil, complete all as specified and directed. |
| 67 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 68 | M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned layers shall be measured. |
| 69 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engineer-in-charge. |
| 70 | Supply and Laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 3 core complete all as specified and directed. |
| 71 | Supply and Laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core complete all as specified and directed. |
| 72 | M & L Steel tubing 40mm dia, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 73 | Cutting through existing bituminous road/PCC/floor approx size width 50cmX60cm depth along cross section of the road for laying of GI Tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified. Please Enable Macros to View BoQ information |
| 74 | Cutting through existing bituminous road/PCC/floor approx size width 50cmX60cm depth along cross section of the road for laying of GI Tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified. Please Enable Macros to View BoQ information |