| Sl. No. | Item Description |
| 1 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. As directed by Engineer in charge. |
| 2 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. As directed by Engineer in charge. |
| 3 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. As directed by Engineer in charge. |
| 4 | Removing cement or lime plaster including disposing of the spoils as directed with all leads, lifts etc, complete. As directed by Engineer in charge. |
| 5 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. As directed by Engineer in charge. |
| 6 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. As directed by Engineer in charge. |
| 7 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. As directed by Engineer in charge. |
| 8 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. As directed by Engineer in charge. |
| 9 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. As directed by Engineer in charge. |
| 10 | Removing wash hand basins/urinals with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete. As directed by Engineer in charge. |
| 11 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 12 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 13 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.0 to 4.5m.) By Mechanical Means |
| 14 | Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 4.5 m to 6.0 m.) By Mechanical Means |
| 15 | Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 6.0 m to 7.5 m.) By Mechanical Means |
| 16 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 7.5m To 10 m.) By MechanicalMeans |
| 17 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means |
| 18 | Providing preconstructional antitermite treatment as per I.S.6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 19 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. |
| 20 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten yearsguarantee on bond paper. |
| 21 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. |
| 22 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. |
| 23 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) |
| 24 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) |
| 25 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. |
| 26 | Seventh Floor |
| 27 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 28 | Providing and laying Cast in situ /Ready Mix cement concrete in M15 of trap/granite/quartzite/gneiss metal for foundation and bedding/steps including steel centering, formwork, laying/pumping, compacting, roughening the mif special finish is to be provided, finishing unevenand honey combed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 29 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) |
| 30 | Seventh Floor |
| 31 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks,laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 32 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 33 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 34 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 35 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 36 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 37 | First Floor |
| 38 | Second Floor |
| 39 | Third Floor |
| 40 | Fourth Floor |
| 41 | Fifth Floor |
| 42 | Sixth Floor |
| 43 | Seventh Floor |
| 44 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 45 | First Floor |
| 46 | Second Floor |
| 47 | Third Floor |
| 48 | Fourth Floor |
| 49 | Fifth Floor |
| 50 | Sixth Floor |
| 51 | Seventh Floor |
| 52 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 53 | First Floor |
| 54 | Second Floor |
| 55 | Third Floor |
| 56 | Fourth Floor |
| 57 | Fifth Floor |
| 58 | Sixth Floor |
| 59 | Seventh Floor |
| 60 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 61 | First Floor |
| 62 | Second Floor |
| 63 | Third Floor |
| 64 | Fourth Floor |
| 65 | Fifth Floor |
| 66 | Sixth Floor |
| 67 | Seventh Floor |
| 68 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 69 | First Floor |
| 70 | Second Floor |
| 71 | Third Floor |
| 72 | Fourth Floor |
| 73 | Fifth Floor |
| 74 | Sixth Floor |
| 75 | Seventh Floor |
| 76 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 77 | First Floor |
| 78 | Second Floor |
| 79 | Third Floor |
| 80 | Fourth Floor |
| 81 | Fifth Floor |
| 82 | Sixth Floor |
| 83 | Seventh Floor |
| 84 | Providing and laying Cast insitu/ReadyMix cement concrete in M-25 of trap/granite/gneiss/quartzite metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood/steelformwork, steelprops, laying/pumping ,compaction ,finishing uneven and honeycombed surface with C.M.1:3 of sufficient minimum thickness to give as mooth and even surface or roughening the surface if special finish is to be provided and curing etc.complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunnybag ,plastic, tarpaulin etc. with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/concrete Batch mixplant (Pan mixer) etc.complete. With fine aggregate (Crushed sand VSI Grade) |
| 85 | First Floor |
| 86 | Second Floor |
| 87 | Third Floor |
| 88 | Fourth Floor |
| 89 | Fifth Floor |
| 90 | Sixth Floor |
| 91 | Seventh Floor |
| 92 | Providing and laying Cast in situ / Ready Mix cement concrete M- 25 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying / pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete ( excluding reinforcement ) . with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 93 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 94 | First Floor |
| 95 | Second Floor |
| 96 | Third Floor |
| 97 | Fourth Floor |
| 98 | Fifth Floor |
| 99 | Sixth Floor |
| 100 | Seventh Floor |
| 101 | Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface |
| 102 | First Floor |
| 103 | Second Floor |
| 104 | Third Floor |
| 105 | Fourth Floor |
| 106 | Fifth Floor |
| 107 | Sixth Floor |
| 108 | Seventh Floor |
| 109 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. |
| 110 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 111 | First Floor |
| 112 | Second Floor |
| 113 | Third Floor |
| 114 | Fourth Floor |
| 115 | Fifth Floor |
| 116 | Sixth Floor |
| 117 | Seventh Floor |
| 118 | Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. |
| 119 | First Floor |
| 120 | Second Floor |
| 121 | Third Floor |
| 122 | Fourth Floor |
| 123 | Fifth Floor |
| 124 | Sixth Floor |
| 125 | Seventh Floor |
| 126 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. |
| 127 | First Floor |
| 128 | Second Floor |
| 129 | Third Floor |
| 130 | Fourth Floor |
| 131 | Fifth Floor |
| 132 | Sixth Floor |
| 133 | Seventh Floor |
| 134 | Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. |
| 135 | First Floor |
| 136 | Second Floor |
| 137 | Third Floor |
| 138 | Fourth Floor |
| 139 | Fifth Floor |
| 140 | Sixth Floor |
| 141 | Seventh Floor |
| 142 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to Concrete surface in all positions including scaffolding and curing etc. complete. |
| 143 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. |
| 144 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffoldingand curing etc. complete. |
| 145 | First Floor |
| 146 | Second Floor |
| 147 | Third Floor |
| 148 | Fourth Floor |
| 149 | Fifth Floor |
| 150 | Sixth Floor |
| 151 | Seventh Floor |
| 152 | Providing internal cement plaster 20 mm thick in Single coats in cment mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. ( Comp. Wall) |
| 153 | Providing internal cement plaster 20 mm thick in Single coats in cment mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. |
| 154 | First Floor |
| 155 | Second Floor |
| 156 | Third Floor |
| 157 | Fourth Floor |
| 158 | Fifth Floor |
| 159 | Sixth Floor |
| 160 | Seventh Floor |
| 161 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6 mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. |
| 162 | First Floor |
| 163 | Second Floor |
| 164 | Third Floor |
| 165 | Fourth Floor |
| 166 | Fifth Floor |
| 167 | Sixth Floor |
| 168 | Seventh Floor |
| 169 | Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. |
| 170 | First Floor |
| 171 | Second Floor |
| 172 | Third Floor |
| 173 | Fourth Floor |
| 174 | Fifth Floor |
| 175 | Sixth Floor |
| 176 | Seventh Floor |
| 177 | Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. |
| 178 | First Floor |
| 179 | Second Floor |
| 180 | Third Floor |
| 181 | Fourth Floor |
| 182 | Fifth Floor |
| 183 | Sixth Floor |
| 184 | Seventh Floor |
| 185 | Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. |
| 186 | First Floor |
| 187 | Second Floor |
| 188 | Third Floor |
| 189 | Fourth Floor |
| 190 | Fifth Floor |
| 191 | Sixth Floor |
| 192 | Seventh Floor |
| 193 | Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. |
| 194 | Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete. |
| 195 | First Floor |
| 196 | Second Floor |
| 197 | Third Floor |
| 198 | Fourth Floor |
| 199 | Fifth Floor |
| 200 | Sixth Floor |
| 201 | Seventh Floor |
| 202 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. |
| 203 | First Floor |
| 204 | Second Floor |
| 205 | Third Floor |
| 206 | Fourth Floor |
| 207 | Fifth Floor |
| 208 | Sixth Floor |
| 209 | Seventh Floor |
| 210 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc.complete.Seventh Floor |
| 211 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 212 | First Floor |
| 213 | Second Floor |
| 214 | Third Floor |
| 215 | Fourth Floor |
| 216 | Fifth Floor |
| 217 | Sixth Floor |
| 218 | Seventh Floor |
| 219 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. |
| 220 | First Floor |
| 221 | Second Floor |
| 222 | Third Floor |
| 223 | Fourth Floor |
| 224 | Fifth Floor |
| 225 | Sixth Floor |
| 226 | Seventh Floor |
| 227 | Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish |
| 228 | First Floor |
| 229 | Second Floor |
| 230 | Third Floor |
| 231 | Fourth Floor |
| 232 | Fifth Floor |
| 233 | Sixth Floor |
| 234 | Seventh Floor |
| 235 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 236 | First Floor |
| 237 | Second Floor |
| 238 | Third Floor |
| 239 | Fourth Floor |
| 240 | Fifth Floor |
| 241 | Sixth Floor |
| 242 | Seventh Floor |
| 243 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 244 | First Floor |
| 245 | Second Floor |
| 246 | Third Floor |
| 247 | Fourth Floor |
| 248 | Fifth Floor |
| 249 | Sixth Floor |
| 250 | Seventh Floor |
| 251 | Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 252 | First Floor |
| 253 | Second Floor |
| 254 | Third Floor |
| 255 | Fourth Floor |
| 256 | Fifth Floor |
| 257 | Sixth Floor |
| 258 | Seventh Floor |
| 259 | Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing andcleaning. etc. complete. |
| 260 | First Floor |
| 261 | Second Floor |
| 262 | Third Floor |
| 263 | Fourth Floor |
| 264 | Fifth Floor |
| 265 | Sixth Floor |
| 266 | Seventh Floor |
| 267 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. |
| 268 | First Floor |
| 269 | Second Floor |
| 270 | Third Floor |
| 271 | Fourth Floor |
| 272 | Fifth Floor |
| 273 | Sixth Floor |
| 274 | Seventh Floor |
| 275 | Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.Seventh Floor |
| 276 | Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary |
| 277 | First Floor |
| 278 | Second Floor |
| 279 | Third Floor |
| 280 | Fourth Floor |
| 281 | Fifth Floor |
| 282 | Sixth Floor |
| 283 | Seventh Floor |
| 284 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of S.E.) |
| 285 | First Floor |
| 286 | Second Floor |
| 287 | Third Floor |
| 288 | Fourth Floor |
| 289 | Fifth Floor |
| 290 | Sixth Floor |
| 291 | Seventh Floor |
| 292 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. |
| 293 | First Floor |
| 294 | Second Floor |
| 295 | Third Floor |
| 296 | Fourth Floor |
| 297 | Fifth Floor |
| 298 | Sixth Floor |
| 299 | Seventh Floor |
| 300 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). |
| 301 | Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares |
| 302 | First Floor |
| 303 | Second Floor |
| 304 | Third Floor |
| 305 | Fourth Floor |
| 306 | Fifth Floor |
| 307 | Sixth Floor |
| 308 | Seventh Floor |
| 309 | Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc.,I.S.I. mark,heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete |
| 310 | First Floor |
| 311 | Second Floor |
| 312 | Third Floor |
| 313 | Fourth Floor |
| 314 | Fifth Floor |
| 315 | Sixth Floor |
| 316 | Seventh Floor |
| 317 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. |
| 318 | First Floor |
| 319 | Second Floor |
| 320 | Third Floor |
| 321 | Fourth Floor |
| 322 | Fifth Floor |
| 323 | Sixth Floor |
| 324 | Seventh Floor |
| 325 | Providing and fixing solid core flush door shutter in double leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. |
| 326 | First Floor |
| 327 | Second Floor |
| 328 | Third Floor |
| 329 | Fourth Floor |
| 330 | Fifth Floor |
| 331 | Sixth Floor |
| 332 | Seventh Floor |
| 333 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 334 | First Floor |
| 335 | Second Floor |
| 336 | Third Floor |
| 337 | Fourth Floor |
| 338 | Fifth Floor |
| 339 | Sixth Floor |
| 340 | Seventh Floor |
| 341 | Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete |
| 342 | First Floor |
| 343 | Second Floor |
| 344 | Third Floor |
| 345 | Fourth Floor |
| 346 | Fifth Floor |
| 347 | Sixth Floor |
| 348 | Seventh Floor |
| 349 | Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete |
| 350 | First Floor |
| 351 | Second Floor |
| 352 | Third Floor |
| 353 | Fourth Floor |
| 354 | Fifth Floor |
| 355 | Sixth Floor |
| 356 | Seventh Floor |
| 357 | Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete. |
| 358 | First Floor |
| 359 | Second Floor |
| 360 | Third Floor |
| 361 | Fourth Floor |
| 362 | Fifth Floor |
| 363 | Sixth Floor |
| 364 | Seventh Floor |
| 365 | Providing and laying in trenches 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 366 | Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. |
| 367 | Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 368 | First Floor |
| 369 | Second Floor |
| 370 | Third Floor |
| 371 | Fourth Floor |
| 372 | Fifth Floor |
| 373 | Sixth Floor |
| 374 | Seventh Floor |
| 375 | Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 376 | First Floor |
| 377 | Second Floor |
| 378 | Third Floor |
| 379 | Fourth Floor |
| 380 | Fifth Floor |
| 381 | Sixth Floor |
| 382 | Seventh Floor |
| 383 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 384 | First Floor |
| 385 | Second Floor |
| 386 | Third Floor |
| 387 | Fourth Floor |
| 388 | Fifth Floor |
| 389 | Sixth Floor |
| 390 | Seventh Floor |
| 391 | Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. |
| 392 | First Floor |
| 393 | Second Floor |
| 394 | Third Floor |
| 395 | Fourth Floor |
| 396 | Fifth Floor |
| 397 | Sixth Floor |
| 398 | Seventh Floor |
| 399 | Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. |
| 400 | First Floor |
| 401 | Second Floor |
| 402 | Third Floor |
| 403 | Fourth Floor |
| 404 | Fifth Floor |
| 405 | Sixth Floor |
| 406 | Seventh Floor |
| 407 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) |
| 408 | Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall |
| 409 | First Floor |
| 410 | Second Floor |
| 411 | Third Floor |
| 412 | Fourth Floor |
| 413 | Fifth Floor |
| 414 | Sixth Floor |
| 415 | Seventh Floor |
| 416 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall |
| 417 | First Floor |
| 418 | Second Floor |
| 419 | Third Floor |
| 420 | Fourth Floor |
| 421 | Fifth Floor |
| 422 | Sixth Floor |
| 423 | Seventh Floor |
| 424 | Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. |
| 425 | First Floor |
| 426 | Second Floor |
| 427 | Third Floor |
| 428 | Fourth Floor |
| 429 | Fifth Floor |
| 430 | Sixth Floor |
| 431 | Seventh Floor |
| 432 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 433 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench complete. |
| 434 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. |
| 435 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. |
| 436 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. |
| 437 | First Floor |
| 438 | Second Floor |
| 439 | Third Floor |
| 440 | Fourth Floor |
| 441 | Fifth Floor |
| 442 | Sixth Floor |
| 443 | Seventh Floor |
| 444 | Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with allnecessary pipe connection etc. complete. |
| 445 | First Floor |
| 446 | Second Floor |
| 447 | Third Floor |
| 448 | Fourth Floor |
| 449 | Fifth Floor |
| 450 | Sixth Floor |
| 451 | Seventh Floor |
| 452 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. complete |
| 453 | First Floor |
| 454 | Second Floor |
| 455 | Third Floor |
| 456 | Fourth Floor |
| 457 | Fifth Floor |
| 458 | Sixth Floor |
| 459 | Seventh Floor |
| 460 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 461 | First Floor |
| 462 | Second Floor |
| 463 | Third Floor |
| 464 | Fourth Floor |
| 465 | Fifth Floor |
| 466 | Sixth Floor |
| 467 | Seventh Floor |
| 468 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 469 | First Floor |
| 470 | Second Floor |
| 471 | Third Floor |
| 472 | Fourth Floor |
| 473 | Fifth Floor |
| 474 | Sixth Floor |
| 475 | Seventh Floor |
| 476 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 477 | First Floor |
| 478 | Second Floor |
| 479 | Third Floor |
| 480 | Fourth Floor |
| 481 | Fifth Floor |
| 482 | Sixth Floor |
| 483 | Seventh Floor |
| 484 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 485 | First Floor |
| 486 | Second Floor |
| 487 | Third Floor |
| 488 | Fourth Floor |
| 489 | Fifth Floor |
| 490 | Sixth Floor |
| 491 | Seventh Floor |
| 492 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. |
| 493 | First Floor |
| 494 | Second Floor |
| 495 | Third Floor |
| 496 | Fourth Floor |
| 497 | Fifth Floor |
| 498 | Sixth Floor |
| 499 | Seventh Floor |
| 500 | Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 501 | Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete. |
| 502 | Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 503 | Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 504 | Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete. |
| 505 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 506 | First Floor |
| 507 | Second Floor |
| 508 | Third Floor |
| 509 | Fourth Floor |
| 510 | Fifth Floor |
| 511 | Sixth Floor |
| 512 | Seventh Floor |
| 513 | Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. |
| 514 | First Floor |
| 515 | Second Floor |
| 516 | Third Floor |
| 517 | Fourth Floor |
| 518 | Fifth Floor |
| 519 | Sixth Floor |
| 520 | Seventh Floor |
| 521 | Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. |
| 522 | First Floor |
| 523 | Second Floor |
| 524 | Third Floor |
| 525 | Fourth Floor |
| 526 | Fifth Floor |
| 527 | Sixth Floor |
| 528 | Seventh Floor |
| 529 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. |
| 530 | First Floor |
| 531 | Second Floor |
| 532 | Third Floor |
| 533 | Fourth Floor |
| 534 | Fifth Floor |
| 535 | Sixth Floor |
| 536 | Seventh Floor |
| 537 | Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. |
| 538 | First Floor |
| 539 | Second Floor |
| 540 | Third Floor |
| 541 | Fourth Floor |
| 542 | Fifth Floor |
| 543 | Sixth Floor |
| 544 | Seventh Floor |
| 545 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 546 | First Floor |
| 547 | Second Floor |
| 548 | Third Floor |
| 549 | Fourth Floor |
| 550 | Fifth Floor |
| 551 | Sixth Floor |
| 552 | Seventh Floor |
| 553 | Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 mx 0.60 m ) |
| 554 | First Floor |
| 555 | Second Floor |
| 556 | Third Floor |
| 557 | Fourth Floor |
| 558 | Fifth Floor |
| 559 | Sixth Floor |
| 560 | Seventh Floor |
| 561 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. completeSeventh Floor |
| 562 | Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 563 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 564 | Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 565 | RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technicalspecification and direction of the Engineer in charge. |
| 566 | Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge. |
| 567 | First Floor |
| 568 | Second Floor |
| 569 | Third Floor |
| 570 | Fourth Floor |
| 571 | Fifth Floor |
| 572 | Sixth Floor |
| 573 | Seventh Floor |
| 574 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below |
| 575 | l) Up to 500 user size (6mx2.0mx1.6m), Capacity of Biodigester:-20000 liters, Area of top, bottom and side walls: - 50.72 sq.m, Area of partition walls: 13.36sq.m, Total weight of FRP: - 917.86 Kilogram, Bacteria inoculums quantity: - 7000 liters, Minimum thickness of side walls / top and bottom: 9 mm, One Number of inside partitions: - 4, Minimum thickness of partition wall: 4mm |
| 576 | Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 18 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS 1608: 2005., as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval. The 18mm thick panels shall be used for a roofing height of upto 25 mtrsSeventh Floor |
| 577 | Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/- |
| 578 | Seventh Floor |
| 579 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1) Tensile Impact Strength ISO 8256 - more than 700Kj/m2, 2) Vicat Softening Temperature EN ISO – 306 Shall not be < 750C, 3) Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2, 4) Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %, 7) Surface Spread of flame BS : 476 - Part 7 Classification 1,8) Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable, 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa, 10) Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa.All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. |
| 580 | 2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47mm |
| 581 | First Floor |
| 582 | Second Floor |
| 583 | Third Floor |
| 584 | Fourth Floor |
| 585 | Fifth Floor |
| 586 | Sixth Floor |
| 587 | Seventh Floor |
| 588 | 3 Track 3 / 6 Sash (Big Series) window frame of size 122 x 54 mm & Sash of size 64 x47 mm |
| 589 | First Floor |
| 590 | Second Floor |
| 591 | Third Floor |
| 592 | Fourth Floor |
| 593 | Fifth Floor |
| 594 | Sixth Floor |
| 595 | Seventh Floor |
| 596 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep withnecessary refilling with bitumen etc. complete. |
| 597 | Structural Glazing ( unit - Per Sq.M ) Desiging, providing fabricating supply and fixing in position structural glazing to external face of the building straight in plan consisting of main panel work of vertical and horizontal made out of specially designed extruded 38 x 83 mm powder coated alluminium section anchor to rcc element through adequately designed powder coated MS clamp bracket using 5mm thick oneway reflective make saint gobain glass ( blue/bronze/green reflective glass ) and weather silicon sealant of approved grade ( Direct sticking ) Material used Mullion section 63 x 83mm Tramsform section 63mm x 38mm Spacer tape sulicon sealant SSG 4000 ULTRA GLAZED / 995 Dow Coring Silproof/ 789 Glass equivalent 5.00mm thick one way reflective in blue/ any colour ( saint Gobin ) The joints shall be properly sealed with approved silicon sealent to make the joint water tight and weather proof including fixing over alluminium frame using mechanical fasterner such as alluminium cleats and fasteners specially designed frame work with vertical and horizontal members of extruded slluminium section wich shall made of alloy 6063 T6 as approved by Enginner in charge ( as per approved drawing ) The work shall complete as per specification and direction of Engineer including all other taxes excluding GST etc complete ( M.S Fabrication work shall be separately Done ) |
| 598 | 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR -Fire Door Tested in accordance to IS: 3614 Part 2. with prior approval of concernedSuperitending Engineer Providing of 120 min Fire rated lead lined doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology (\\"Non Combustible by Nature\\"). Lead lined to check radiation. Code No; 2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODENDOOR - Fire Door Tested in accordance to IS: 3614 Part 2. |
| 599 | a) Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets with 10mm overlap from either side & spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed in the groove of the Frame for fire and hot and cold smoke sealing, etc. complete as per direction of Engineer in Charge |
| 600 | First Floor |
| 601 | Second Floor |
| 602 | Third Floor |
| 603 | Fourth Floor |
| 604 | Fifth Floor |
| 605 | Sixth Floor |
| 606 | Seventh Floor |
| 607 | b) Shutter: Providing of 57mm thick asbestos free composite, 'TUFWUD' brand - 3 criteria - fire, heat and smoke check Lead Lined Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x30 mm with 30mm thick infill of ceramic fibre (density 128 Kilograms/CMT) vermiculite mix, 3mm thick Lead Sheet on one side faced & 3mm Fire retardant High Density Fibreboard, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of Intumescent paint of minimum 300 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. |
| 608 | First Floor |
| 609 | Second Floor |
| 610 | Third Floor |
| 611 | Fourth Floor |
| 612 | Fifth Floor |
| 613 | Sixth Floor |
| 614 | Seventh Floor |
| 615 | c) Vision Panel:1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside theshutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11mm thick havingminimum 120 minutes fire Description |
| 616 | First Floor |
| 617 | Second Floor |
| 618 | Third Floor |
| 619 | Fourth Floor |
| 620 | Fifth Floor |
| 621 | Sixth Floor |
| 622 | Seventh Floor |
| 623 | Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of Integrated Wetland Technology (IWT) based Sewage Treatment Plant (STP) consisting of Screen chamber, Oil &Grease trap, RCC Primary treatment tanks (including manholes, vent pipes and graded gravel media) and RCC Secondary treatment tanks (SBBR) (including gravel media, PVC sheets, wetland plants, plastic mesh, etc. as required.) tank, RCC intermediate and treated water tank, sludge recirculation pump and pipe network, room for tertiary atment unit, E&M works for tertiary treatment including associated piping work, internal pathways, wire fencing, etc. complete as turnkey job with all involved civil, electrical and mechanical worksinclusive of following items, units as per detailed specifications for civil, electrical and mechanical components with all duties and taxes, etc.plete as directed by Engineer-In-charge. Allied Sructure shall be constructed as per the provision in appropriate and relevant standards and design guidelines of respective authorities. RCC and civil works will be as directed by Engineer-in-charge. Sewage Treatment Plant (STP) to be designed to treat the row water sewage with the characteristics in table number \\"A\\" to produce the treated sewage with characteristics as mentioned in table number \\"B\\" Raw Sewage Characteristics Temperature Ambient pH - 5.5-9.0 BOD - 300 mg/L COD - 600 mg/L_0.10 MLD ( 100 KLD) |
| 624 | Designing, Manufacturing as per drawing, Supplying andInstalling in position, GFRC jali (WJ) (height as per drawing) Specifications : GFRC- Compressive strength - 80 MPA, Flexural strength (MOR) - 18 MPA, Flexural LOP - 8 MPA , Wherever required GFRC with stud frame and flex anchors to be adopted for cornices or similar components. Mild steel if used should be passivated and with a epoxy primer and PU coating. Exposed steel brackets/cleats/hardware should be hot dip galvanized (HDG). Fasteners- plated from HILTI/KLIMAS/FISCHER or equivalent. The price shall include preparation of shop drawings, manufacturing, transport, unloading and installation completed in all respects including scaffolding upto 3 storeys or 12 m height if required. As directed by Engineer-In-Charge. Dimension - 0.05m Thick. |
| 625 | First Floor |
| 626 | Second Floor |
| 627 | Third Floor |
| 628 | Fourth Floor |
| 629 | Fifth Floor |
| 630 | Sixth Floor |
| 631 | Seventh Floor |
| 632 | Transporation of material obtained from debries of various sorts including necessary excavation / loosing including loading, unloading, conveying & disposing as directed. For 5kmSpec. No. As directed by Engineer-in-charge |
| 633 | Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for a butment returns, return walls etc. Complete. |
| 634 | Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: (1) Elongation % (ASTM D412-2016): @ 100% (2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 (3) Specific Gravity: 1.02 ± 0.02 (4) Total Solids (ASTM D1644-2012): 43.98 (5) Hardness Shore A(ASTM D2240-2015): 82 |
| 635 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mmat weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box As directed by Engineer in charge. |
| 636 | Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. |
| 637 | Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint). |
| 638 | Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). |
| 639 | Providing and laying cement concrete pipe of IS 458 : 2003 NP -2 class of 450 mm dia meter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 640 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. |
| 641 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. |
| 642 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete. |
| 643 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 644 | Compacting the hard murum side widths including laying in layers oneach side with vibratory roller including artificial watering etc. complete. |
| 645 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material |
| 646 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specificati on including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requi site type of screening / binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading I (Using Screening Type B (11.2 mm) Aggregate) |
| 647 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specificati on including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requi site type of screening / binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading Il (Using Screening Type B (11.2 mm) Aggregate) |
| 648 | Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete. |
| 649 | Providing cast in situ /ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary formwork, compaction, finishing and curing etc. complete.(with reversible drum type mixer / concrete batch mix plant (pan mixer) with SCADA |
| 650 | Providing and fixing Ductile iron manhole cover of light/medium/heavy duty with frame of any size over inspection chamber etc. complete (Prior permission of S.E.is to be obtained before inclusion of this item in the estimate) |
| 651 | Providing and fixing 45 cm wide mild steel ladder of 40 mm x 6 mm mild steel flat stringer sand steps of 18 mm dia. mild steel bar for water tank including fixing itin (1:2:4) M- 15 cement concrete block 60 cmx 30cm x30 cm and painting the ladder complete. (AntiCorossive Paint) |
| 652 | Providing and applying a base coat comprising of 1Kilogram Polydee-MC and 1 Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP -40 and afte rdrying, applying Polydee- 11 two component (mixing ratio 2A:1B)) Anti bacterial food grade coating in sided rinking water tank in two coats with time interval of minimum 8hrs. covering 7 years guaranteeon Court Fee Stamp Paper of Rs. 100/- etc. complete. |
| 653 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a) |
| 654 | Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms. ( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b) |
| 655 | Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.47) |
| 656 | Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5) |
| 657 | Filling fresh garden soil / silt & manure in excavated area of depth 20cms. (As per P&G DSR 2022-23 Items of garden work,Sr No.15) |
| 658 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23) |
| 659 | Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.29) |
| 660 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.60 x 0.60 x 0.60m (consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.52) |
| 661 | Providing on site required variety of Tree (free from weeds /diesease etc.) 4 mtr. apart c/c.Name:-Bakul ;Bag Size 13 x 13 '', ht 6-8'(plants list sr no2, item no 5b) |
| 662 | Providing on site required variety of Tree (free from weeds /diesease etc.) 4 mtr. apart c/c.Name:-Bakul ;Bag Size 18 x18'', ht 8-10'(plants list sr no2, item no 5c) |
| 663 | Providing on site required variety of Tree (free from weeds /diesease etc.) 4 mtr. apart c/c.Name:-Sonchafa ;Bag Size 10 x10'', ht 3-4'(plants list sr no 33, item no 1b) |
| 664 | Providing on site required variety of Tree (free from weeds /diesease etc.) 3 mtr. apart c/c.Name:-Tabebuia ;Bag Size 13 x 13'', 6-8' ht (plants list sr no 14 item no 5b ) |
| 665 | Providing on site required variety of Tree (free from weeds /diesease etc.) 6 mtr. apart c/c.Name:-Deshi Badam ;Bag Size 13 x 13'', ht 6-8'(plants list sr no 4, item no 6b) |
| 666 | Providing on site required variety of Tree (free from weeds /diesease etc.) 8 mtr. apart c/c.Name:-Kadamb ;Bag Size 13x13'', ht 6-8'(plants list sr no5, item no 5b) |
| 667 | Providing on site required variety of Tree (free from weeds /diesease etc.) - mtr. apart c/c.Name:-Spathodia ;Bag Size 13x13\\"'', ht 6-8'(plants list sr no 13, item no 5b |
| 668 | Providing on site required variety of Tree (free from weeds /diesease etc.) - mtr. apart c/c.Name:-Amaltash ;Bag Size 13x13'', ht 6-8'(plants list sr no1, item no 5b) |
| 669 | Providing on site required variety of Tree (free from weeds /diesease etc.) - mtr. apart c/c.Name:-Karanj ;Bag Size 13x13'', ht 6-8'(plants list sr no 8, item no 6b) |
| 670 | Providing on site required variety of Tree (free from weeds /diesease etc.) - mtr. apart c/c.Name:-Ficus Benjamina ;Bag Size 13 x13'', ht 2-3'(plants list sr no13, item no 2b) |
| 671 | Providing on site required variety of Tree (free from weeds /diesease etc.) - mtr. apart c/c.Name:-Green wichimeri Palm ;Bag Size 18 x18'', ht 5-6'(plants list sr no 6, item no 11d) |
| 672 | Providing on site required variety of Tree (free from weeds /diesease etc.) - mtr. apart c/c.Name:-Golden wichimeri Palm ;Bag Size 18 x18'', ht 5-6'(plants list sr no 5, item no 11d) |
| 673 | Excavation pit size 0.60 x 0.60 x 0.60m for planting small & medium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 mtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.11) |
| 674 | Filling fresh garden soil / silt & manure in excavated pit size area of 0.60 x 0.60 x 0.60m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.21) |
| 675 | Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 0.60 x 0.60 x 0.60m. (1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.26) |
| 676 | Maintainance of Newly Planted tree varities having height 1mtr. - 2mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.34) |
| 677 | Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. |
| 678 | RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge |
| 679 | Royalty Charges |
| 680 | Royalty Charges on Mining materials used in construction. Murum/metal |
| 681 | Royalty Charges on Mining materials used in construction. Sand |
| 682 | Testing Charges |
| 683 | Carrying out Basic test of Cement Standard Consistency,Fineness, Specific gravity, setting time (initial & Final)Compressive Strength,soudness in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. |
| 684 | Fineness Modulus (sieve Analysi) Silt & Clay Content |
| 685 | Chloride & Sulphate Content |
| 686 | Silt Factor |
| 687 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Crushing value, ii) Impact value, iii) Specific gravity, iv) Water absorption |
| 688 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. v) Sieve lanalysis |
| 689 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vii) Abrasion Value |
| 690 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vi) Flakiness Index & Elongation Index. |
| 691 | Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vi) Soundness |
| 692 | Testing of Bricks for- Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). |
| 693 | Carrying out test of concrete casted at site in the form of cubes of 150x150x150mm size casted during conctering in the laboratory including conveying the cubes/material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Compessive strength |
| 694 | Carrying out Mix design with all Tests on Concrete Mix Design basic materials of concrete of various grade from the material collected at site in the laboratory including conveying all required material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. |
| 695 | Carrying out various test of HYSD / TMT /FE-500 Steel transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Weight / metre, ii) Ultimate tensile stess, iii) Yield stress, iv) Elongation Test, a)Below 16mm dia. |
| 696 | Testing of Steel above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.) |
| 697 | Carrying out Standard test of water Absorption , Flexural test on Flooring Stones (Kota Stone/graite Stones Stones etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.(i) Water Absorption (Set of 6 Tiles, Flextural test (Set of 6 tiles) |
| 698 | Carrying out Standard test of water Absorption , Flexural test on Flooring Tiles (Ceramic tiles/Vetrified tiles etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.(i) Water Absorption (Set of 6 Tiles, Flextural test (Set of 6 tiles) |
| 699 | Testing of Flush door for Knife Test, Adhesion Test, End Immersion Test. |
| 700 | Testing of Aluminium section Thickness, Mass Per Running meter, |
| 701 | GSB Mix Design |
| 702 | Carrying out testing BASIC TEST OF WATER PH Value, Sulphate & Chloride Content. |
| 703 | Carrying out testing BASIC TEST OF P.V.C. PIPES (NONPLASTISIZED) Weight per running meter,Diameter of pipe & wall thickness of pipe |
| 704 | Electrification WorkSUB WORK - I - E.I |
| 705 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 706 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 707 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 708 | SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 709 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 710 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 711 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 712 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 713 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 714 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 715 | Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 716 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 717 | Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 718 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places.as per specification No: WG-MA/BW |
| 719 | Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit) |
| 720 | Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit earth) |
| 721 | Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW (PDB & Main LDB Circuit) (Rs 152 x 2 = 304) |
| 722 | Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) (Rs 152 /2 = 76.00) |
| 723 | Supplying & erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (Main PDB Circuit) |
| 724 | Supplying & erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) |
| 725 | Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW |
| 726 | Supplying and erecting mains with 1x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW |
| 727 | Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW |
| 728 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 729 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 730 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 731 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 732 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 733 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 734 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background |
| 735 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 736 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background. |
| 737 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background |
| 738 | Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. |
| 739 | 1-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW |
| 740 | 2-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW |
| 741 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW |
| 742 | Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW |
| 743 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switc |
| 744 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing ncapping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 745 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 746 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 747 | Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WP W/CW |
| 748 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG |
| 749 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 750 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 751 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 752 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs.at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 753 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 754 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/FLS2 |
| 755 | Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 756 | Supplying & erecting 5W-7W,, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 757 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 758 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% withot IR remote control/ compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 759 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. |
| 760 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab |
| 761 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (for ceiling Fn) |
| 762 | DISTRIBUTION SYSTEM |
| 763 | Supplying & erecting four pole ON LOAD change over switch, 415V, 400A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3... |
| 764 | Supplying and erecting switch disconnector fuse (SDF) switch 415V, 200A, open execution, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse, insulation voltage 1000 V for enclosing in panel with rotary handle for ON /OFF operation (without HRC fuse) |
| 765 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 766 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 767 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 768 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 769 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board. |
| 770 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 80/100A in provided distribution board. |
| 771 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 772 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 773 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 774 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as perspecification no. SW-SWR/MCBDB |
| 775 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB |
| 776 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 777 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 778 | Providing & erecting 4 Pole MCCB, 415 V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 779 | Providing & erecting 4 Pole MCCB, 415 V, 250A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 780 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magneticsetting with provided leads, provision for installation of shunt/ UV/ trip alarm contact.MCCB should have phase barriers both sides, with insulation withstand capacity 800V,no line-load bias in provided enclosure /panel as per specification no. SW-MCCB |
| 781 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 782 | Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO |
| 783 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO |
| 784 | Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 785 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 4 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) |
| 786 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) |
| 787 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 4 way outgoing or 400A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coatedand having vertical insulated partition for shielding between the shared face of cableway and DB |
| 788 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coatedand having vertical insulated partition for shielding between the shared face of cableway and DB. |
| 789 | Supplying and erecting DIN Type HRC Fuse cartridge 500V, 200A |
| 790 | PANEL WORK |
| 791 | Supplying, installing, testing and commissioning air circuit breaker manual fixed type, non-drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 Pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/ hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ ACB |
| 792 | Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides,with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB |
| 793 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. |
| 794 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 795 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP- |
| 796 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 797 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 798 | Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. |
| 799 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 800 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring &connections etc. |
| 801 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. |
| 802 | Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 803 | CABLE |
| 804 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 805 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 806 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 807 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 808 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 809 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 810 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 811 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 812 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room) |
| 813 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware |
| 814 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 815 | EARTHING |
| 816 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI (Main OT DB-1, Main AC DB-1, MLDB-1, MPDB-1, M Med Inst PDB-1, Pump DB-1, MCCB Panel-1, LA-2) |
| 817 | Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 818 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standardlength with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. |
| 819 | Sub - Work II -LIFT |
| 820 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (20 mtr for 1 Lift) |
| 821 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 8 mtr) |
| 822 | Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 7 mtr) |
| 823 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 mtr) |
| 824 | Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 mtr) |
| 825 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (shaft- (bulkhead-1 & socket-1)x 2= ) |
| 826 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (shaft - 4 ) |
| 827 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. (Lift Room- 1 x 1= 1 x 2 = 2) |
| 828 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (Lift Room power- 1 x 1= 1 x 2 = 2) |
| 829 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. (Lift Room power- 1 x 1 = 1 x 2 =2) |
| 830 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected (shaft- 4 x 1 = 4 x 2 = 8) |
| 831 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW (Lift room-3 no) |
| 832 | Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW /CW (Lift Room- 1) |
| 833 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (Shaft 4 x 1= 4) |
| 834 | Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB (Lifr Romm power-1) |
| 835 | Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB (shaft Lighting-1, Romm SB-1) |
| 836 | Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SW-RCCB/RCCB (Lift Room 4-SPN enclosure) |
| 837 | Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCBerected on angle iron/GI frame complete. (4P RCCB-1, 2P RCCB+2SP MCB-1) (2 x 2=4) |
| 838 | Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 839 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 840 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 841 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 842 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 843 | Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall /cable /conduit with screws complete. (8 SWG Tar- 0.116 kg / mtr - 40 Mtr x 0.116 Kg/Mtr = 4.64 Kg x 1 Lifts) |
| 844 | SITC of Electric Traction Passenger Lift with Rated capacity :- 8 Passenger/544Kg · Floors :- LG+UG+G+2 floor (5 Stops/5 Landings) · Travel :- 20 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VSCar/Landing door clear opening of 1000 mm wide x 2000mm highClear Car size of .1500mm wide x 2000mm deep x 2250mm highLift shaft available having clear size of 1850 mm wide x 1850 mm deep, 1800mm Pit depth, 5100 mm Overhead. (AS PER NBC REQUIRED SHAFT- 1900 x 1900) Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).\\"· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.\\"\\"· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor\\" |
| 845 | LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation\\"operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. \\"· ARD complete with necessary SMF VRLA batteries · Fireman controller having fireman switch at fire Landing, \\"· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge\\" |
| 846 | Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work\\"· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\\" General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 847 | For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete |
| 848 | SITC of Electric Traction Passenger sLift with Rated capacity :- 10 Passenger/680Kg· Floors :- G+7 floor (8Stops/8 Landing) · Travel :- 32 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VSCar/Landing door clear opening of 1000 mm wide x 2000mm highClear Car size of .1500mm wide x 2000mm deep x 2250mm highLift shaft available having clear size of 1850 mm wide x 2250 mm deep, 1800mm Pit depth, 5100 mm Overhead. (AS PER NBC REQUIRED SHAFT- 1900 x 2750) Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).\\"· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.\\"\\"· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor\\" |
| 849 | · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation\\"operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. \\" |
| 850 | ARD complete with necessary SMF VRLA batteries · Fireman controller having fireman switch at fire Landing, \\"· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work\\"· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\\" General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 851 | For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete |
| 852 | SITC of Electric Traction Passengers Lift with Rated capacity :- 13 Passenger/884Kg· Floors :- LG+UG+G+7 floor (10Stops/10 Landing) · Travel :- 40 mtrs · Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VSCar/Landing door clear opening of 1000 mm wide x 2000mm highClear Car size of .1500mm wide x 2000mm deep x 2250mm highLift shaft available having clear size of 1850 mm wide x 2250 mm deep, 1800mm Pit depth, 5100 mm Overhead. (AS PER NBC REQUIRED SHAFT- 1900 x 2750) Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).\\"· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.\\"\\"· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor\\" |
| 853 | · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation\\"operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. \\"· ARD complete with necessary SMF VRLA batteries · Fireman controller having fireman switch at fire Landing, \\"· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge\\" |
| 854 | · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work\\"· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.\\" General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. |
| 855 | For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete |
| 856 | SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 857 | SITC of Quadruplex Lift control system for four nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/ control/ data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 858 | For Lift travelling above First floor & up to Sixth floor |
| 859 | Sub - Work III -TELEPHONE & DATA SYSTEM TELEPHONE CABLE & IT'S OTHER WORK |
| 860 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 861 | SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 862 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 863 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 864 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 865 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background |
| 866 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 867 | Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW (main telephone cable) |
| 868 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 869 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 870 | Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 32 universal extensions suitable upto 96 extensions compliant to IEC 61000, EN 60950, CISPR 22, IS:9000 part 2/section 4 having LAN/WAN port, USB port, RS232 port as per specification complete as per specification no. WGTA. |
| 871 | NETWORKING & IT'S OTHER WORK |
| 872 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background |
| 873 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 874 | Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC |
| 875 | Supplying and erecting 6 fibers LSZH armoured multimode optical fiber cable with, core dia 50/125 μm (OM3), suitable upto 10 GBPS, compliant to IEC 60793/IEC 60794 standards, on wall/ceiling or laid in provided pipe/ trench as per specification no. WG-ELVC/OFC. |
| 876 | Supplying and erecting 12 fibers LSZH armoured multimode optical fiber cable with , core dia 50/125 μm (OM3), suitable upto 10 GBPS, compliant toIEC 60793/IEC 60794 standards, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-ELVC/OFC |
| 877 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 878 | Supplying and fixing 12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/ LIU |
| 879 | Supplying and fixing Cat 6A 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP |
| 880 | Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK |
| 881 | CCTV WORK |
| 882 | Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC. |
| 883 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 884 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 885 | Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC |
| 886 | Supplying and erecting 6 fibers LSZH armoured multimode optical fiber cable with, core dia 50/125 µm (OM3), suitable upto 10 GBPS, compliant toIEC 60793/IEC 60794 standards, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-ELVC/OFC |
| 887 | Supplying, fixing, and configuring 24 ports, PoE switch compliant with IEEE 802.3 standards with min. 193W PoE capacity with 4GE SFP uplink in provided rack as per specification no. WG-NWC/ENS |
| 888 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 889 | Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA |
| 890 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 891 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°, 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°, 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 892 | Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR |
| 893 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 894 | Supplying & erecting 43\\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features : Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1, Viewing angle: 178/178 deg. Response time: maximum 8 ms, Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 895 | AC UNIT INSTALLATION WORK |
| 896 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free Operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 897 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free Operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC |
| 898 | Supplying, installing, testing and commissioning tower type room AC unit of 4.0TR to 4.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/R410A & copper condenser coil with anticorrosive fins copper condenser, hydrophilic evaporator Fins Powder coated outer body, withscroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe. |
| 899 | DRAIN PIPING |
| 900 | Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 901 | COPPER PIPING |
| 902 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. |
| 903 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. |
| 904 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 19 mm for solar water heater/AC system |
| 905 | DG SET WorkGENERATOR FOUNDATION |
| 906 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match theswitchgears or as per directions by the authority. |
| 907 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. ( 3.5 Mtr X 2.0 Mtr X 0.3 Mtr) |
| 908 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. |
| 909 | GENERATOR FOR COMMON AREA |
| 910 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 58.5 kVA confirming to CPCB-IV plus Emission Compliant with output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f.A.C supply, a totally enclosed liquid cooled multi in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-0. 5 %, with performance class G2 Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, with suitable capacity DEF tank provided with first filling of oil, diesel tank capacity not less than 150 Litres etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector if necessary. This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per latest Government norms) approved Norms. . |
| 911 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA confirming to CPCB-IV plus Emission Compliant with output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f.A.C supply, a totally enclosed liquid cooled multi in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-0. 5 %, with performance class G2 Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, with suitable capacity DEF tank provided with first filling of oil, diesel tank capacity not less than 230 Litres etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector if necessary. This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per |
| 912 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 50 kVA up to 62.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. ...(10% less) |
| 913 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF...(10% less) |
| 914 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 915 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 916 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 917 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. (25x3 GI Strip - 30 Mtr x 0.59 Kg/Mtr = 17.7) |
| 918 | WATER PUMP Work |
| 919 | Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP |
| 920 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (1 running & 1 standby) |
| 921 | Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assemblycomplete. |
| 922 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 923 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 924 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 925 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 926 | Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. |
| 927 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 928 | Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete. |
| 929 | Supplying & erecting four pole ON LOAD change over switch, 415V, 40A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying toIS/IEC 60947-3 Part-1/3. (for openwll pump, incase felure) |
| 930 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 931 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 932 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 933 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 934 | Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only |
| 935 | OTHER ITEMS Work |
| 936 | Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.50 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS |
| 937 | Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete. |
| 938 | WATER COOLER |
| 939 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specificationno. AP-WCR/WC |
| 940 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copperwire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.. |
| 941 | Fire Fghting ArrangementPUMP ROOM |
| 942 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : |
| 943 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW c |
| 944 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed ( Diesel Engine) |
| 945 | CONTROL PANEL FOR FIRE PUMPS |
| 946 | Supplying, erecting, testing & commissioning of fire pump control panel(FCP) of cubical construction, floor mounted type, fabricated from minimum 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, withenclosure protection class IP54, duly powder coated or painted with accessoriesduly painted with two coats of synthetic enamel paint of fire red colour over acoat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnectionwith suitable size solid copper busbar strip of adequate size for all powerconnections having switchgears and accessories, mountings and internal wiringwith adequate size copper conductor cable, earth terminals, numbering etc.complete in all respect, suitable for satisfactory operation of main fire pump andjockey (pressurisation) pumps (1working+1standby) with necessary accessories,wiring & cabling along with allied accessories with following incoming andoutgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz acsupply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby,alternate run per start in auto mode)comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomerand branches to motor SFU's, starters & outgoing terminals with necessaryaccessories like stainless steel nut bolts with spring washers for connections,mounted on required no of epoxy or porcelain support insulators of suitableratings etc. |
| 947 | 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitablerating.4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP,O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.Each 1837016. Required pressure transducer with pressure indication on panel with cablingrequired for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey(pressurization) pumps in sequence with interlocking for operation of pumps asper specification with automatic/manual operation with selector switch &alternate run of standby Pumps consisting of relays, timers. sensors, annunciationwindow for fault indication, complete as per specification. 8.Suitable capacityelectric motor starters for all individual pumps with necessary push buttons &indications.9. Siren of required capacity to be activated when main pump starts & alliedaccessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS.11. Spare HRC fuses minimum 2 nos of each individual rating with requiredbakelite fuse holder for main & jockey fire pumps MFP=(1working), JP =(1working+1standby, alternate run per start in auto mode) complete panel, as perspecification no. FF-MFP/ECP |
| 948 | 4 For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs… |
| 949 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware |
| 950 | 300x 20mm |
| 951 | 200x 20 mm |
| 952 | 150 x 20 mm |
| 953 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 954 | 3.5 Core x 120 Sq.mm. F XLPE , Armoured, Aluminium cable for main pump |
| 955 | 3.5 Core x 70.Sq.mm. XLPE , Armoured, Aluminium cable for main pump |
| 956 | 4 Core x 10Sq.mm. , XLPE , Armoured, Aluminium cable for main pump |
| 957 | Supplying, installing, testing and commissioning FR, XLPE armoured cable2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceilingcomplete as per specification no. CB-LT/CU |
| 958 | Supplying and erecting GI strip of required size used for earthing on wall and/orany other purpose with necessary GI clamps fixed on wall painted withinsulating and non-corrosive bond with required joints as per specification no.EA-EP. 50 mm x 6mm strips |
| 959 | Fire Plant room-Piping & Valves |
| 960 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 961 | 200 mm dia |
| 962 | 150 mm dia |
| 963 | 100 mm dia |
| 964 | 80 mm dia |
| 965 | 65 mm dia |
| 966 | 50 mm dia |
| 967 | 25 mm dia |
| 968 | Supplying and erecting Following sizes dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 969 | 200 mm dia |
| 970 | 150 mm dia |
| 971 | 100 mm dia |
| 972 | 80 mm dia |
| 973 | 65 mm dia |
| 974 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 975 | Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 976 | 150mm dia |
| 977 | 100mm dia |
| 978 | Supplying and erecting cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 979 | 80mm dia |
| 980 | 150 mm dia |
| 981 | 200mm dia |
| 982 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG. |
| 983 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 984 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 985 | HYDRANT SYSTEMHydrant Piping |
| 986 | Supplying, installing, testing and commissioning of G.I. 'B' class pipe line confirming to IS 1239 malleable specials extruded type, such as Reducers, elbows, flanges. necessary puddle flanges for tank connection, laying of pipes in excavated trenches, proper supports at bottom. |
| 987 | 80mm dia |
| 988 | 100mm dia |
| 989 | 150mm dia |
| 990 | Providingcoating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fig hting system. |
| 991 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 992 | Supplying and erecting 150mm dia firebrigadeheader suitablefor supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 993 | Supplyingand erecting stainlesssteel single outlet hydrant valvefittedwith necessary accessories complete as per specification no. FF-VL/HV |
| 994 | Supplying and erecting 63mm dia,reinforced rubberlined(R.R.L.) hosepipe, 15min length, fittedwithnecessaryaccessoriescompleteas per specification no. FF-FFA/RRL |
| 995 | Supplying and erecting stainlesssteel branch pipe 63mm diafitted with 20 mm diadetachable hexagonal nozzle completeasper specificationsno.FFFFA/NZ |
| 996 | Supplying and erecting M.S./CRCA cabinet for housing double hose pipewith nozzle (size 750 x 600x 250 mm.) made from 16 SWG sheet and angleiron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and lockingarrangement with necessary fixing material such as rubber bidding etc. dulypainted in post box red colour( Code 538 of IS 5) |
| 997 | Supplying and installing wall mounting swinging hose reel drum fitted with 19mm dia. 30m long high pressure polypropylene (Polyhose) alongwith necessaryaccessories complete as per specification no. FF-FFA/HV |
| 998 | SPRINKLER SYSTEM |
| 999 | Supplying, installing, testing and commissioning of G.I. pipes of class 'C' to confirm IS 1239, malleable specials extruded type, such as Reducers, elbows, flanges. The pipes shall be painted with primer & Paint using approved type, Galvanized, supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails \\"U\\" & threaded bolt, Including cutting, Welding, fixing in / on walls, ceiling by using the supports etc, as per drawings. |
| 1000 | 25mm dia |
| 1001 | 32 mm dia |
| 1002 | 40 mm dia |
| 1003 | 50mm dia |
| 1004 | 65mm dia |
| 1005 | 80mm dia |
| 1006 | 100mm dia |
| 1007 | 150mm dia |
| 1008 | Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 1009 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 1010 | Butterfly Valve |
| 1011 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1012 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1013 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 1014 | Supplying and erecting cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 1015 | 150 mm dia |
| 1016 | Supplying, erecting, testing and commissioning of Upright/ Pendent quartzoidbulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixedtemperature rating with deflector disc of conventional construction complete asper specification no. FF-SPR./UP |
| 1017 | Supplying erecting, testing and commissioning of sprinkler flexible pipe ofstainless steel complete with 15 NPT on reducer thread with maximum workingpressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet)25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female threadwith reducer, nipple, 2 side brackets, center bracket, stockbar of 1000 mm size(UL Listed) complete as required as per specification no. FF-SPR/FHP |
| 1018 | ADDRESSABLE FIRE ALARM SYSTEM |
| 1019 | Supplying, installing, testing and commissioning of addressable manual callpoints ( break glass type/pull station type), made of addressable break glassplastic square in shape surface/flush mounted with \\"Break Glass\\" massageembedded on the glass, complete erected with mounting base and requiredaccessories, Module shall conform to EN 54/VdS / UL & FM approved with 3years equipment replacement warranty, as per specification no FF-AFAS/MCP.. |
| 1020 | Supplying, installing, testing and commissioning of Addressable Sounder cumStrobe rated at minimum 75 dB @ 3m for Audible annunciation and minimum75cd flashing at 1 Hz for visual indication. Module shall conforming to IS 2189:2008, IS 15908:2021 / EN 54/VdS / UL & FM approved with 3 years equipmentreplacement warranty, as per specification no FF-AFAS/ S-ST |
| 1021 | Supplying, installing, testing and commissioning of addressable fire isolatormodule for isolating short / dewired / loose circuits with automatic resettingarrangement. Isolator Base can also be proposed, however in that case needs tobe considered with each detector & module. The device shall have an LED whichshall blink in normal state & get steady on activation to monitor the health statusof the device. module complete as required. Module shall conforming to IS 5051Part 2 (Sec 1 to 3) : 1982, , EN 54/VdS / UL & FM approved with 3 yearsequipment replacement warranty, FF-AFAS/ISM |
| 1022 | SSupplying, installing, testing and commissioning of Addressable Optical PhotoSmoke Detector. The detector shall have multi co-operative sensing technologyfor faster response & avoid false alarms. The detector shall have single/twin bicolourLED for 360 deg viewing. The detector is conforming to IS 2189: 2008,11360_1985_Reff2020_EN 54 /VdS / UL & FM approved with 3 yearsequipment replacement warranty, Designed to meet UL268, 7th Edition. FFAFAS/SD. |
| 1023 | Supplying, installing, testing and commissioning of intelligent addressablethermal/heat detector with rate of rise cum fixed temperature thermistorcomplete with 0°C to 58°C temperature range, with base as required, single/twinLED’s with 360 degree view, in-built locking mechanism to check the removaland pilferage of the detector, Detector Shall conforming to IS : 2175 - 1988reaffirmed 2000, IS 15908:2021 / EN 54 / VdS / UL & FM approved with 3years equipment replacement warranty, Designed to meet UL268, 7th Edition.FF-AFAS/HD - ROR. |
| 1024 | Supplying, installing, testing and commissioning of micro processor basedintelligent addressable main fire alarm panel, central processing unit with the4 loop capacity and capable of supporting not less than 250 devices and detectorsper loop, with on-board LCD alphanumeric backlit display suitable for minimum80 characters, operating at 230 V 50 Hz - AC with inbuilt Battery Backup of aminimum 24 hours in normal condition and 30 minutes in alarm condition, Thepanel shall have suitable provision for network connectivity & compatible forthird party integration(Open Protocol to communicate) via aMODBUS/BACNET interface etc. conforming to IS 15908:2021, IS 2189: 2008,NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with 3 years replacementwarranty and inclusive of lifetime software license validity , as per specificationnoFF-AFAS/CP. |
| 1025 | Supplying, installing, testing and commissioning of repeater panel with suitablebattery backup of a minimum of 24 hours in normal condition and 30 min inalarm condition, minimum 10\\" LCD or LED display with resistive touch screenor function keys and automatic back-light dimming and the status of anyFire/Fault of Integrated Fire Alarm Panels or minimum 80 characters backlitalphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manualcontrol keys for silence/mute and to reset the FACP from the repeater station.Panel shall conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 /VdS/FM & UL with 3 years replacement warranty FF-AFAS/RP. (Compatiblewith 1/2 Loop Fire Alarm Control Panel), as per specification no FF-AFAS/RP |
| 1026 | Supplying, installing, testing and commissioning FR, XLPE armoured cable2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceilingcomplete as per specification no. CB-LT/CU |
| 1027 | FIRE EXTINGUISHER |
| 1028 | ABC type, 6 kgs capacity,chemical fire extinguisher, as per IS:15683, portable, with gun metal cap and nozzle including initial fill and wall brackets for mounting |
| 1029 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 1030 | Mechanical Foam(AFFF) type extinguisher of 9 Ltrs Capacity for kitchen, including hose, valve and initial fill. As per IS:10204. |
| 1031 | Singages Lot ,like fire lift,staircase,extinguisher,assembly point,pump house etc for whole building |
| 1032 | HVAC Work |
| 1033 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 1034 | Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 1035 | Supplying, erecting, testing and commissioning of 22HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 1036 | Supplying, erecting, testing and commissioning of 24HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 1037 | Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 1038 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.2TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 1039 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 1040 | Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.5TR (512cfm) to 1.8TR (618 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. |
| 1041 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.0TR (618cfm) to 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1042 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1043 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100cfm) to 3.2TR ( 1165 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1044 | Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165cfm) to 4.0TR ( 12185 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1045 | Supply, installation, testing and commissioning of VRF/VRVbased ceilingsuspended 1 way cassetteroom/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.8TR (575 cfm) to 2.7TR(953 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 1046 | Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017 |
| 1047 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 1048 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1049 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1050 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application ofmulticoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1051 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1052 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1053 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1054 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1055 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1056 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 1057 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnut complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation,painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. |
| 1058 | Supply, installation, testing and commissioning wireless remote controlhavingcolour LCD panel, real time clock, temperature limitation (16 to 30° C,functions like filter clean reminder timer suitable to communicate with wiredcontroller complete. |
| 1059 | Supplying, erecting, testing and commissioning centralised programmableremote control panel (HMI) touch manager controls minimum 16 systemof 64 ODU's can be controlled and up to 992 IDU's can be individuallymounted and controlled indoor units having colour min 200mm size LCD touchpanel, yearly schedule, power proportional distribution function, temperaturelimitation, history function complete erected on wall integrated with provided firealarm system. |
| 1060 | Supplying and installing of collar damper of galvanised iron material of upto 120microns for anti corrosive resistance for supply air grill of suitable size |
| 1061 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 1062 | Supplying, installing, testing and commissioning FR, XLPE armoured cable2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceilingcomplete as per specification no. CB-LT/CU |
| 1063 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit. |
| 1064 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 1065 | Supply, installation, testing and commissioning of factory built Floor mounted double skin type Air Handling Units with thermal break profile made of 43 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8 mm outside layer and 0.8 mm plane inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW backward curved centrifugal fan of , 6 row deep cooling coil, section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type inlet EU-3 filters, belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with mixing box, drain connections with drain valve, drain pan, necessary vibration isolation arrangement etc, With AHU accessories like expansion valve, drier, PCB, liquid valve, hand shut off valve, flare nut/AHU kit for VRF ODU etc with Cordless /Corded remote control .The Air Handling Unit Shall have necessary drive set.complete as per specifications of following capacities: 34 TR 13500 CFM @ 80MMIn 28.4 deg.C DB / 22.9 deg.C WBOut 13.3 deg.C DB / 13.0 deg.C WB |
| 1066 | AXIAL FAN FOR FRESH AIR & EXHAUST AIR |
| 1067 | SITC of Vane Axial type fan with baseframe, single piece rouged construction axial fan, anciallary structure required to fix in masonary / RCC walls, connection flanges, TEFC motor, inbuilt direct driven, grouting frame & safety guard, vibration Isolators (Spring type), Flexible Connection at Outlet & Inlet Screen. Fans shall be direct driven not exceeding 1460RPM. Motor shall have IP-55 protection, Class 'F' insulation, 415 ± 10%, 50Hz 3 phase AC power supply. Fan Assembly certified as per the AMCA 210 air performance and AMCA 300 for sound performance. Fans shall be selected and installed to have noise level not more than 65 ± 5 DBa at 3meter from source. All the hardwares shall be hot dip galvanised. |
| 1068 | Lower Basement 17500CFM, Min 25 mm ESP ( Exhaust Fan For Lower Basement) |
| 1069 | Lower Basement 16000CFM, Min 25 mm ESP (Exhaust Air Fan for Lower Basement) |
| 1070 | Lower Basement 17500CFM, Min 25 mm ESP ( Fresh Air Fan For Lower Basement) |
| 1071 | Upper Basement 17500CFM, Min 25 mm ESP (Fire Mode+Normal Mode) Exhaust air fans |
| 1072 | Upper Basement 15000CFM, Min 25 mm ESP (Fire Mode+Normal Mode) Exhaust air fans |
| 1073 | JET FAN |
| 1074 | SITC of dual speed high temperature rated Jet Impulse Axial Fans. Fan should include inlet / outlet silencers & mounting arrangements. Fan should be capable of running at 250°C at least for 2 Hours. Jet fans shall be complete with casing made of powder coated mild steel, roll formed, welded and hot-dip galvanized after fabrication and insulated to class H. High temperature motor with impeller shall be constructed of die cast aluminum alloy. Impeller should have aerodynamic profile. Fan to be provided with galvanized steel outlet deflector and zinc/cadminum plated inlet guard. Two speeds can be obtained by reconnecting a single winding via six winding terminals to give two separate pole, suitable for 415±10% volts, 50 cycles, 3 phase AC power supply. |
| 1075 | Lower Basement : Dual Speed 315mm Dia Jet Fans -3200 CFM (Fire Mode) / 1600 CFM (Normal Mode) having 50N thrust. |
| 1076 | Upper Basement : Dual Speed 315mm Dia Jet Fans - 5200 CFM (Fire Mode) / 2600 CFM (Normal Mode) having 50N thrust. |
| 1077 | SOLAR PV PANEL WORK |
| 1078 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short- circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 1079 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 1080 | Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority |
| 1081 | Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 1082 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL |
| 1083 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 1084 | Providing and erecting 545 to 550 Watt Framed Dual Glass Bi-Facial Solar Module Panel Having MechnicalCheracterics of 2272 x 1133 x35 (LxWxT), Weight 33.3 KG, Front Glass 2 mm Low Iron HTAR semi-tempered glass and Back Glass 2mm Low Iron Printed semi- tempered glass, Having Electrical Characterics of Vmp of 41-43 Volt DC, Current 13A DC, Juncton Box IP65, MC4 Cable Connector with Sqmm, 500mm Cable including in Panel Junction Box. Bifacial Power output at 30% Rediation 700W, at Module Efficiency of 27% With 5 Years of On-Site Warrenty (Reference Taken from TS No: T-49/CE? 2025-26 Letter No 6264/2025 Dt: 30/06/2025. Providing EI & Fire work to Admin Building at Ballarpur Dist Chandrapur) |
| 1085 | Providing and erecting of Transformerless Solar On GridString Inverter having Mechnical Cherecterics of IP65Rating, Multi Information LCD Display. Built in Wifi, DC Switch, Electrical Characterics of 1100V DC InputVoltage, Input Power of 1200W DC, MPPT Voltage Range o f200 to 950V, Start up Voltage of 180V, Nominal Output Power 25KW AC,Output Voltage of 400V, 3Ph, 5Wire AC (3L/N/PE), Max Output Current of 15A AC, withPower factor Adjustable to +0.80 to -0.80. Max Efficiency 98.50% Including all Accessories like ACDB, DCDB,Wiring, Earthing, DC & AC Cables of Appropriate sizes. (Reference Taken from TS No: T-49/CE? 2025-26 Letter No 6264/2025 Dt: 30/06/2025. Providing EI & Fire work to Admin Building at Ballarpur Dist Chandrapur) |
| 1086 | Supplying and erecting HT CT multifunction DLMS compliance of accuracy of class 0.5 , 3x63.5V,50 Hz with optical & RS 232 port, backlit LCD, measures kWh, kVAh, V, I, kW, 6 months history of energy , load survey, & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display inabsence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box. |
| 1087 | Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail