| 1 | Providing Electrical Engineer (B-tech with min. 3 years experience or Diploma holder with 7 years experience) for supervision, operation and maintenance of pump houses and associated complete electrical works and infrastructure. Wages & other Statutory Charges details as payable to the Engineer engaged under the contract:Basic Pay- Rs. 40,000.00Reliever Charges (1/6th)- Rs. 6,666.67Total- Rs. 46,666.67 The minimum wages payable to Electrical Engineer shall be Rs. 46,666.67 per month as per the breakdown details given above. The bidder is required (shall be entitled) to quote service charges per person that would be charged by him for provisioning of manpower subject to minimum 3.85% over the amount of Rs. 46,666.67. The Bidder may quote any percentage of charges as per his calculations & estimation, however in no case the service charge should be less than 3.85% which are minimum service charges, however Contractor may quote higher sservice charges as per his discretion. The quoting of lower percentage than 3.85% towards service charges may result in to tender being considered as non-responsive. |
| 2 | Providing Manpower in Skilled Category (06 Electricians, 03 Pump Operator, 04 AC Operator, 04 GenSet Operator, 04 Carpenter & 05 Plumber) for running/operation of pumps & other pumping installations in shift duties as decided by the Engineer-in-charge. Minimum Wages & other Statutory Charges details as payable to the labour/manpower engaged under the contract shall be as under:Basic Pay- Rs. 26,208.00EPF @13% upto 15000/- - Rs. 1950.00Total- Rs. 28,158.00Reliever Charges (1/6th)- Rs. 4693.00Total- Rs. 32,851.00 The minimum wages payable to Skilled Category shall be Rs. 32,851/- per month as per the breakdown details given above. The bidder is required (shall be entitled) to quote service charges per person that would be charged by him for provisioning of manpower subject to minimum 3.85% over the amount of Rs. 32,851/-. The Bidder may quote any percentage of charges as per his calculations & estimation, however in no case the service charge should be less than 3.85%or minimum service charges, however Contractor may quote higher sservice charges as per his discretion. The quoting of lower percentage than 3.85% towards service charges may result in to tender being considered as non-responsive. |
| 3 | Providing Manpower in Semi-Skilled Category (4 Trained Helper) for running/operation of pumps & other pumping installations in shift wise. Wages & other Statutory Charges details as payable to the labour/manpower engaged under the contract:Basic Pay- Rs. 23,868.00EPF @13% upto 15000/- - Rs. 1,950.00Total- Rs. 25,818.00Reliever Charges (1/6th)- Rs. 4,303.00Total- Rs. 30,121.00 The minimum wages payable to Semi-Skilled Category shall be Rs. 30,121/- per month as per the breakdown details given above. The bidder is required (shall be entitled) to quote service charges per person that would be charged by him for provisioning of manpower subject to minimum 3.85% over the amount of Rs. 30,121/-. The Bidder can quote any percentage of charges as per his calculations & estimation, however in no case the service charge should be less than 3.85%or minimum service charges, however Contractor may quote higher sservice charges as per his discretion. The quoting of lower percentage than 3.85% towards service charges may result in to tender being considered as non-responsive. |
| 4 | Comprehensive maintenance of DG set of 750 KVA including cost of all labour and replacement of defective parts including replacement of consumable like oil, coolant, filters, Servicing lubricants (except fuel-diesel), fuels injectors monthly full load test run for minimum 2 hours, maintenance upkeep of exhaust Pipe and its painting twice a year with approved paint. Checkup/ upkeep/ maintainance of voltage regulator (AVR) governs, oil pressure, oil pressure valves, air filters, fuel filters, horses, belt, vibration control, full vibration analysis complete including annual major over handing of DG set as per OEM schedule. Also complete comprehensive maintenance of AMF panels with bus bar, relays, MCCBs, earthing, incomers, outgoing, timer, connectors, thimbles complete as per inventory given in technical bid including maint/upkeep of fuel tank. Complete for daily, weekly, monthly, quarterly, half yearly and yearly comprehensive maintenance including one complete annual over hauling of DG Set with all cost of labour, replacements of defective parts, replacement of lubricants/oils, filters for in untrumpeted functioning of DG set all as directed by the Engineering In-charge. (The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89. |
| 5 | Comprehensive maintenance of 1250 kVA- (2 no x 12 months = 24 months). transformer, oil immerseds to include weekly, monthly, quarterly, and yearly maintenance of transformers as per broad maintenance schedule given in technical bid & strictly as per OEM/Manufacturer instructions.The comprehensive maintenance shall include:daily maintenance program weekly maintenance program monthly maintenance program quarterly maintenance program yearly maintenance program complete in all respect as per complete OEM instructions. The Comprehensive maintenance shall include all manpower required for the work, replacement of defective parts, periodic checking of insulation resistance, IR test, oil filter, cleaning/replacement of parts, desludging and cleaning of main tank and conservator cleaning/replacing of defective/worn out filters checking of gaskets/bushing, servicing complete as per manufacturer instructions to ensure uninterrupted functioning of transformer, complete including cost of all manpower, consumables and replacement of defective parts all as directed by the Engineer-in-charge.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89. |
| 6 | Comprehensive maintenance of HT panel including cost of all labour, manpower, replacement of defective parts comprising of Vacuum circuit breaker(VCB) 400A 2 nos, insulators, busbars, contact resistance, lubricants, Volt meter, Ammeters, servicing/maintenance of shunt trip closing or under voltage coils & replacement of defective parts, testing of insulation, resistance, terminals, secondary terminals, MCCBs, earthing, safety interlocks, auxilliary switches, relays, indicating lamps complete including weekly, monthly, quarterly & yearly maintenance as per OEM instructions complete all specified & directed by Engineer-in-charge complete for uninterupted functioning of Panels & replacing all defective/worn out parts. As per inventory of the item given in technical bid documents.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89. |
| 7 | Comprehensive maintenance of LT panel including cost of all labour, manpower, replacement of defective parts comprising of insulators, busbars, contact resistance, lubricants, Volt meter, Ammeters, servicing/maintenance of shunt trip closing or under voltage coils & replacement of defective parts, testing of insulation resistance, terminals, secondary terminals, earthing, safety interloades, auxilliary switches, relays, indicating lamps complete including weekly, monthly, quarterly & yearly maintenance as per OEM instructions complete all specified & directed by Engineer-in-charge compute for uninterupted functioning of Panels & replacing all defective/worn out parts. As per inventory of the item given in the technical bid documents all inclusive.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 75-91. |
| 8 | Comprehensive Maintenance Services for Electrical feeder pillars including incoming/outgoing feeders, Switchgear, busbars, protection devices, terminations earthing system and all associated components including periodic inspection of Feeder pillar, checking of voltage, current, load balancing, abnormal heating, noise, overall condition of components checking and servicing of MCCBs, isolators, contactors, relays, attending fault promptly, including identification, repair/replacement of defective components, replacing consumables and spares such as Lugs, glands, ferrules, fasteners, lubricants, MCCB, MCBs, busbar replacement. Contractor Shall provide all necessary tools, testing instruments etc. and safety equipment. Ensuring compliance with applicable electrical safety standards, statutory regulations and safe working practices complete all as per OEM instructions. NSDP-Basement, NSDP- Ground FloorESDP- First FloorNSDB- First FloorESDB- Second FloorNSDB- Second FloorRoad Lighting PanelESDB-Old Building NSDB- Old Building Total = 9 Panels (9 x 12 months = 108 )(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89. |
| 9 | Comprehensive Maintenance of Air Conditioning |
| 10 | Comprehensive maintenance of central air-conditioning plant to include weekly, monthly, quarterly & yearly maintenance of the installed system as per OEM maintenance schedule including of all manpower & replacement of defective part, items, equipment complete. The central air conditioning system comprising of water chilling machine 40TR -3 Nos., hot water generator system (HWG)-6 Nos, AHUs of different capacities (AHU 2 -10000 cfm/4 RD Cooling coil (Zone 4), AHU 3- 2600cfm/6RD Cooling coil (Zone 5), AHU 4- 5400cfm/6RD Cooling coil (Zone 9), AHU 5- 12200cfm/6RD Cooling coil (Zone 10), AHU 6- 6800cfm/6RD Cooling coil (Zone7) and AHU 7- 2500cfm/6RD Cooling coil (C.S.S.D) coaling towers, pumps (CHW/CDW) ducting and installation, electrical panel and control, thermostats, compressor, refrigerant gas, piping, coils complete to ensure uninterrupted functioning of installations complete in all respect including cost of labour, materials & replacement of defective parts, provisioning of cooling gas refrigerant & maintenance (weekly, monthly, quarterly & yearly maintenance) of record of servicing in the approved format complete all as directed by Engineer-in-charge.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89 |
| 11 | Comprehensive maintenance service for complete VRF air conditioning system installed for Obs & gynae ward/ unit consisting of outdoor unit of 38HP-2 Nos, indoor unit ductable 32TR- 2 Nos, AHU of 4000 CFM with allied piping, y joints, ducting Refrigerant gas, services and other connected parts, This includes routine maintenance of VRF system, monitory system performance, checking daily operation parameter (pressure, temperature, fault codes), cleanings of indoor unit filters, evaporator coils, checking refrigerator gas pressure and system health. PCB boards repair/replacement of faulty component, leak detection. Rectification and vacuuming and including supply and replacement of all spare parts and consumable such as compressor, PCBs, sensors and actuator etc.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89 |
| 12 | Comprehensive maintenance service for complete VRF air conditioning system installed for Neonatal Intensive Care Unit (NICU)/ Pediatric Intensive Care Unit (PICU) consisting of outdoor unit of 12HP-12 Nos, outdoor unit of 8HP- 02 Nos, DX AHU 6500 CFM 14TR- 06 Nos & DX AHU 4500 CFM 8.8TR- 01 Nos with allied piping, y joints, ducting Refrigerant gas, services and other connected parts, This includes routine maintenance of VRF system, monitory system performance, checking daily operation parameter (pressure, temperature, fault codes), cleanings of indoor unit filters, evaporator coils, checking refrigerator gas pressure and system health. PCB boards repair/replacement of faulty component, leak detection. Rectification and vacuuming and including supply and replacement of all spare parts and consumable such as compressor, PCBs, sensors and actuator etc.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89 |
| 13 | Comprehensive maintenance service for complete VRF air conditioning system installed for OPD block consisting of outdoor unit of 18HP-04 Nos, indoor unit highwall 1.5T- 17 Nos, & indoor unit ductable 8TR- 04 Nos with allied piping, y joints, ducting Refrigerant gas, services and other connected parts, This includes routine maintenance of VRF system, monitory system performance, checking daily operation parameter (pressure, temperature, fault codes), cleanings of indoor unit filters, evaporator coils, checking refrigerator gas pressure and system health. PCB boards repair/replacement of faulty component, leak detection. Rectification and vacuuming and including supply and replacement of all spare parts and consumable such as compressor, PCBs, sensors and actuator etc.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89 |
| 14 | Comprehensive maintenance service for complete VRF air conditioning system installed 3rd floor consisting of outdoor unit of 30HP- 2 Nos, outdoor unit of 20HP- 03 Nos, outdoor unit 16HP- 1 Nos with allied piping, y joints, ducting Refrigerant gas, services and other connected parts, This includes routine maintenance of VRF system, monitory system performance, checking daily operation parameter (pressure, temperature, fault codes), cleanings of indoor unit filters, evaporator coils, checking refrigerator gas pressure and system health. PCB boards repair/replacement of faulty component, leak detection. Rectification and vacuuming and including supply and replacement of all spare parts and consumable such as compressor, PCBs, sensors and actuator etc. (The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.)As per inventory of items attached from page no. 73-89 |
| 15 | Comprehensive Maintenance of UPSComprehensive maintenance of UPS system of 160KVA capacity including routine operation, preventive maintenance, breakdown maintenance, checking input/output voltage, inspection of Control Cards, foam, capacitors, cleaning UPS internals, Battery inspection, regular check of voltage, replacement fuses, relays, indicators etc. If the batteries found dead, new batteries would be provided by the Department to the Contractors. The new battries if the battries have out covered there life during the period of contract shall also be provided by Board.(The contractor shall be required to maintain maintenance schedule registers to record details of all maintenance carried out under weekly quarterly, yearly maintenance programme as per format given by the Engineer-in-charge.) |
| 16 | UPS of capacity 20 kVA-02Nos. |
| 17 | UPS of capacity 60 kVA-02Nos. |
| 18 | Comprehensive maintenance including weekly, monthly, quarterly & yearly upkeep, cleaning, servicing of split Acs with electrical MCBs/Switches, replacement of defective parts, cleaning of filters, copper piping, maintaining cooling gas levels including providing cooling gases. (78 nos x 12 months = 936 ) |
| 19 | 1.5 Ton |
| 20 | Comprehensive maintenance including weekly, monthly, quarterly & yearly upkeep, cleaning, servicing of Window Acs with electrical MCBs/Switches, replacement of defective parts, cleaning of filters, copper piping maintaining cooling gas levels including providing cooling gases. (52 nos x 12 months = 624 ) |
| 21 | 1.5 Ton |
| 22 | Comprehensive monthly cleaning of Overhead RCC Water Tank of capacity 80,000 litres mounted on the roof of Cantonment General Hospital including cost of all labour, T&P, safety equipment, disinfectants, bleaching powder, approved cleaning chemicals and allied consumables required for proper cleaning and maintenance of the water tank. The work shall include draining out of water, removal of sludge, silt, mud and deposited impurities from bottom and side walls of tank, scrubbing and cleaning of internal surfaces, disinfection of tank with approved disinfectants, cleaning of inlet/outlet pipes, overflow pipes, manhole covers and float valves complete for hygienic and uninterrupted water supply. The work shall also include checking of leakages, condition of RCC structure, covers, valves and pipe connections and carrying out minor rectification for proper functioning of the system as directed by the Engineer-in-Charge.The cleaning shall be carried out on monthly basis as per approved schedule and in accordance with applicable public health and safety standards. The contractor shall maintain proper cleaning records/registers indicating date of cleaning, manpower deployed, disinfectants used and observations during inspection as per format approved by the Engineer-in-Charge for satisfactory maintenance and upkeep of the overhead water tank system. |
| 23 | Providing 2 sets each of summer & winter uniform to all the manpower engaged under the contract by the bidder.Summer uniform : Trouser-Shirt & ShoesWinter uniform : Trouser, Shirt- Sweater & JacketThe colour, design and pattern of the uniform shall be as approved by the Engineer-in-Charge.Summer & Winter Uniform to be provided to outsourced manpower shall be considered as one set. |