| 1 | Dismantling of asbestos cement (corrugated, etc) sheets in roof coverings |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for wind ties complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar incl all arches, pillars etc but excluding ashlar facings dressed stone quoins work complete all as specified and directed. |
| 4 | M&L for Brick work with sub-class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 5 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed |
| 6 | M&L for Rendering 15 mm thick in cement mortar 1 : 6 for fixing of wall tiles complete all as specified and directed. |
| 7 | M&L for rendering 15 mm thick in cement mortar 1 : 4 with 3% water proofing compound as per manufacturers instructions (Note : water proofing compound shall be measured and paid seprerately under respective item) on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 8 | Supply only water proofing compound |
| 9 | M&L mild steel works as in wind ties for roof including securing bolts, posts and struts in fencing incl cutting tops to shape as diected, drilling holes, notching for wire etc, flat iron fillets for securing wire mesh etc and for valley gutters etc incl all necessary drilling, bolting or riveting etc and similar works confirming to Fe-410 or Fe-310 upto any height of builing complete all as specified. |
| 10 | S & F roof trusses (Framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including pieces, cleats etc. |
| 11 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 12 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 13 | S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 14 | M & L for preparation of old painted surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 15 | M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified specified and directed. |
| 16 | M&L for preparation of old steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified specified and directed. |
| 17 | M&L for preparation of newly steel surfaces any description not exc 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified specified and directed. |
| 18 | M & L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 19 | M & L for two coats of distemper oil emulsion over old plastred surfaces of wall incl preparation of surfaces complete all as specified and as directed. |
| 20 | M & L for two coats of distemper oil emulsion over newly plastred surfaces of wall incl preparation of surfaces complete all as specified and as directed. |
| 21 | M&L for preparation of old surfaces of wall by brooming down or steel wire brushing scraping down smoke soot, moulds mass and efflorescent salts trading oil and greasy spots etc and applying one coat of white wash over old decorated surface of walls all as specified and directed by Engr-in-charge. |
| 22 | M & L taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan-necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories) |
| 23 | S & F 160mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 24 | S & F PVC SWR bends any radius of size 160mm bore all as specified and as directed |
| 25 | M&L for cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in coping bed etc cocomplete all as specified and directed. |
| 26 | S & F MS bands straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps hold fasts, will ties, hooks for handing fans, plain angle cleats for securing purlings to wood trussed or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to FE 410-o or Fe-310-0 complete all as specified and directed. |
| 27 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made for conditions separately ) and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing without andulations complete all as specified and directed |
| 28 | Takig down carefully existing ceiling/exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan and deposit to MES store yard of AGE E/M Complete all as specified and directed. |
| 29 | Material and labour for cutting chasing,pinning of brick/ stone/concrete wall at any height wall cutting and chases for concealed wiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 30 | Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 25/casing caping 25 mm dia medium grade(MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of and including white/Silver/Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directed for the following:- (a) One light point controlled by one switch. |
| 31 | (b) One fan point controlled by one switch and one regulator. |
| 32 | (c) One exhaust fan point controlled by one switch . |
| 33 | (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 34 | (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 35 | (f) One bell/buzzer point controlled by one bell push. |
| 36 | (g) One light point controlled by two 2 way switches. |
| 37 | All as per item No.4(d) & (e) above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 38 | (b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. |
| 39 | All as per item No.4 (d) above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. |
| 40 | Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed. |
| 41 | Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Marked complete all as specified and directed. |
| 42 | Supply & fixing modular type bell push 6 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and directed. |
| 43 | Supply & fixing modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed. |
| 44 | Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed. |
| 45 | Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed |
| 46 | Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 0 to 4/5 steps, ISI Marked complete all as specified and directed. |
| 47 | Supply and fix call bell AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed. |
| 48 | Supply & fix angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed. |
| 49 | Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 50 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make:- Havells or equivalent in Crompton/Philips any approved make |
| 51 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells or equivalent in Crompton/Philips any approved make |
| 52 | Supply and fixing LED high bay down lights 70 watts |
| 53 | Supply and fixed in repairs LED bldg secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from ceiling rose/looping box/switch board/DBs to light fitting and testing and including removing of old unserviceable item complete all as specified and directed.Make:- Havells or equivalent make in Crompton / Philips as approved |
| 54 | Supply and fixed in repairs recess mounting 2'x2' LED 40/42 Watt light fitting slimmest 9 mm thin in class LED ceiling panel with best in class aesthetick white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm mudular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete all as specified and directed. Make:- Havells or equivalent in Crompton/Philips any approved make |
| 55 | Supply and fixing decorative LED 9 watt decorative, globe type,high quality ploycarbonate materials suitable for 9 watt LED lamp ,B22,220 Volts AC with high efficiency, soft glare free light complete with LED lamp,holder suitable for wall surface and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. Make :-Havells or equivalent make in Crompton/Philips |
| 56 | Supply and fixing 12 watt LED panel type slim, compact,aliminium die cast edge lit panel recess mounted square/round type light fitting with LED opal diffuser (lamp/strip) and separate electronic LED driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified Make :-Crompton/Havells/Philips |
| 57 | Supply and fixing 15 watt LED panel type slim, compact,aliminium die cast edge lit panel recess mounted square/round type light fitting with LED opal diffuser (lamp/strip) and separate electronic LED driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified Make :-Crompton/Havells/Philips |
| 58 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 59 | Supply & fix and sheet metal enclosure with metal type AD/DD,415 volts AC,VTPN DB,, flush mounting with 200amps copper busbar, 2 neutral/earth bar and MCCB incomer,FP, and MCB SP /TP as outgoing and complete for IP54 DBs protection and including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 60 | Supply & fix and sheet metal enclosure with metal type AD/DD,415 volts AC,TPN DB,, flush mounting with 200amps copper busbar, 2 neutral/earth bar and MCB incomer,FP, and MCB SP /TP as outgoing and complete for IP54 DBs protection and including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 61 | Supply & fix and sheet metal enclosure,AD/DD 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 62 | Supply & fix MCB SP 6 to 32 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed.Make:- Legrand/Hager/Havells or as approved make |
| 63 | Supply & fix and MCB SPN 32 - 40 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed.Make:- Legrand/Hager/Havells or as approved make |
| 64 | Supply and fix suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 230 Volts,50Hz suitable for AC's/Geysers complete all as specified and directed.Make:- Legrand / Hager/ Havells or as equivalent approved make |
| 65 | Supply and fix MCCB 100Amps 415Volts,16 KA,4 pole,50 Hz complete all as specified and directed |
| 66 | M & L for sub main wiring complete with 4 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit/PVC casing caping in concealed/surface as per site requirement, ISI marked medium grade(MMS) ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 67 | M & L for sub main wiring complete in repairs with 2 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn drawn through and including PVC conduit/ casing caping in concealed/surface as per site requirement, ISI marked medium grade(MMS) accessories such as Tee,corner, overlaping connector etc and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC casing caping shall be measured as one unit. |
| 68 | M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 69 | M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit/PVC casing caping in concealed/surface as per site requirement, ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 70 | M & L for sub main wiring complete with 2 run of 2.5 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit/PVC casing caping in concealed/surface as per site requirement, ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 2.5 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 71 | M & L for sub main wiring complete with 2 run of 1.5 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 1.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 1.5 sqmm single core copper conductor cable and one run of 1.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 72 | Hanging/fixing only of ceiling fans and connecting up including provision of cable from ceiling rose to fan connector complete all as specified and directed. (Item operated for supply only ceiling fans) |
| 73 | Supply and fix air circulator heavy duty turbo force wall mounted,metal body type fan 230Volts single phase oscillating 600 mm sweep and all connected accessories and including providing hanging heavy duty GI plate/clamp, nuts, bolts and washers complete all as specified and directed.Make :- Havells Turbo Force Wall or equivalent in Atomberg/Almonard/ Orient as approved. |
| 74 | Taking down old unserviceable ceiling fans of any type/sweep from work site and deposit to MES store yard Supply only ceiling fans complete with blades, down rods, and connected accessories, 230 V, 1200mm sweep. Min air delivery 225 CFM with service value 6.00 BEE,Star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make:-Havells, Atomberg, Orient or equivalent approved |
| 75 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, steel /PVC body AC single phase.230Volts of size 300 mm sweep with blades and frame with louvers complete all as specified and directed.Make:-Havells/Crompton or as approved make |
| 76 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, steel body AC single phase.230Volts of size 380 mm sweep with blades and frame with louvers complete all as specified and directed.Make:-Havells/Crompton or as approved make |
| 77 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, steel body AC single phase.230Volts of size 450 mm sweep with blades and frame with louvers complete all as specified and directed.Make:-Havells/Crompton or as approved make |
| 78 | Supply and fixing new exhaust fan made of sturd engineering plastic complete with louvers shutters, voltage 230v,50hz,rpm 1200 copper winding of sweep 200 mm complete all as specified and directed. Make:-Havells/Crompton or as approved make |
| 79 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25M deep below ground level) with top edge of plate not less than 1.5M below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5M whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. |
| 80 | Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed. |
| 81 | Supply and fix modular white cover plate with frame 1 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 82 | Supply and fix modular white cover plate with frame 2 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 83 | Supply and fix modular white cover plate with frame 3 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 84 | Supply and fix modular white cover plate with frame 4 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 85 | Supply and fix modular white cover plate with frame 6 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 86 | Supply and fix modular white cover plate with frame 8 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 87 | Supply and fixing in repairs modular switch 1 way,10Amps,1module,240V, ISI Marked, and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 88 | Supply and fixing in repairs modular switch 1 way,16Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 89 | Supply and fixing in repairs modular type socket shuttered type 6/10 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 90 | Supply and fixing in repairs modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 91 | Supply and fixing in repairs modular switch 2 way,10Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 92 | Supply and fixing in repairs modular type step fan speed regulator 100/120 W, 2 module,230volts,AC, 360 degree rotation ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 93 | Supply and fixing in repairs modular bell push 1 way,10Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 94 | Supply and fixing in repairs call bell AC, 230 Volts single pole, multi music type ISI marked, and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed. |
| 95 | Taking down / Dismatling carefully old unserviceable existing capacity/any type water cooled central AC plant and duct along with all accessories such as angle iron supports,nuts,bolts and washers, outside cement coated plaster,existing wool,rusted iron sheets without any damages in inside wooden panels/existing ceiling and also in existig buildig surface,structure old unserviceable materials should be deposited in MES yard complete all as per specified and dircted by Engr-in-Charge. Please Enable Macros to View BoQ information |