| 1 | Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth |
| 2 | Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6 |
| 3 | Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 R.C.C. grade M 25 |
| 4 | Supplying, fitting and placing TMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 5 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar |
| 6 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1 :5 (1 cement : 5 coarse sand), including pointing with cement mortar 1 :2 (1 cement: 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 8 | Painting on Steel Surfaces Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 |
| 9 | Providing corrugated G.S. sheet roofing including vertical I curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G . I . limpet washers or with G . I . limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required.1 . 0 0 mm thick with zinc coating not less than 275 gm/m2 |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 11 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 12 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 13 | Providing and fixing LED Sign Board named ' Jh izseuxj vkJe xaxk ?kkV in 3\\" inch moulded acrylic letters of height 36\\"inches,LED Modules, rain proof electric supply system etc to be fixed over Framework of S.S. square pipes of size 50x50x1.2 mm with foundation to vertical and sloping support of framework (framework to get approved from consulting Architect) etc. complete to be fixed at required location as directed by Consulting Architect (Acrylic Latter Board with LED) |
| 14 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as pertechnical specification Clauses 613.4 & 1204 |
| 15 | High Mast 20M. with 12 Lamp Carriage: Design, Manufacture, Supply, installation, testing & commissioning of 20M high mast complete in all respects including electrically operated raising and lowering gear, double-drum winch with steel wire ropes, integral power tool, lantern carriage, top pulley arrangement complete with hot-dip galvanised finish, RCC foundation with excavation in soil, foundation bolts, anchor plates, nuts, washers including multicore copper conductor cable (Trailing cable) in two circuits (each for 12 nos. 250W LED Light Fixture) of suitable current-carrying capacity between top carriage and the base terminal (inside mast) including provision of outdoor type double-door feeder pillar made of 14swg CRCA sheet with powder-coated paint, comprising of suitably rated one no. incomer TP MCCB of 25KA and two nos. outgoing circuits with TP MCB(s) of 10KA, Auto ON/OFF with astronomical switch, contactor(s) , timer toggle switches, interconnecting copper wiring, etc. as required suitable for operation on 415V, 3-phase, 50Hz, AC power supply. The scope of work also includes installation of 12 nos. floodlight luminaires, provision of lightning arrester, one no. LED obstruction light fixture erected with lantern carriage and connected in two separate wiring/connections from mast control board, extending earth strip from feeder pillar to mast body, connections, interconnections, complete as required and as specified. |
| 16 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x37 x 25 x1 .6 mm fixed to ceiling with 1 2 . 5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be prepainted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 17 | 1 2 . 5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0 . 1 6 mm thick fire retardant PVC film on the face side and 1 2 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 18 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 19 | Ridges plain (500 - 600mm) |
| 20 | Barge board (Upto 300 mm) |
| 21 | Gutter (600 mm over all girth) |
| 22 | Halonix LED Luminaire (Recessed Luminaire) (40W 4000K LED 2x2 Recessed Flat Panel)Confirming to IS 10322(part5/section2)and particular Requirements for LED Luminaire (recessed Luminaire )confirming to IS 16107 (part 2/section 1)Luminaire class 1 as per clause 2.1 section 2 of IS 10322(part 1) Square Shape size 600x600mm |
| 23 | Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 20 Nominal mix 1:2:4 Please Enable Macros to View BoQ information |