Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8way, Double door (IP43, IK09) |
| 2 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 3 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09) |
| 4 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door (IP43, IK09) |
| 5 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 25A |
| 6 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 32A |
| 7 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A |
| 8 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A |
| 9 | Supply, installation, testing and commissioning 'B' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 10 | Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO) (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB |
| 11 | Laying and fixing of PVC insulated and PVC sheathed / XLPE powercable of 1.1 KV grade of following size on cable tray as required. |
| 12 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 13 | Supply, connection, testing and commissioning of heavy duty, medium voltage,XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductorArmoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified.The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge.The scope shall include:1) Supply of Cables.(With Non Returnable Drums)2) Delivery of the cables at site.3) Unloading at site store.4) Shifting of cable from site store to place of installation.5) Connection of cable with proper tagging as specified ni specifications.6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely.7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar.8) Testing of insulation and continuity of cable and submission of reports to the client's representative.9) To prepare submission drawing and to take approval of consultant at each stage.10) To prepare & submit as-built drawing and handing over document to end user.11) Rate shall be inclusive of route markers at 15mtr intervals12) Each run of cable to be tested with 1KV meggar13) Proper cables tags of Aluminium shall be made and feeder shall be written.Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS |
| 14 | 4C x 10 Sq.mm. CU XLPE armored cable |
| 15 | 4C x 6 Sq.mm. CU XLPE armored cable |
| 16 | 3C x 4 Sq.mm. CU XLPE armored cable |
| 17 | 3.5C x 25 Sq.mm. Aluminum XLPE armored cable |
| 18 | 4C x 4 Sq.mm. CU XLPE armored cable |
| 19 | 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 20 | Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland.Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI |
| 21 | 4C x 10 Sq.mm. CU XLPE armored cable |
| 22 | 4C x 6 Sq.mm. CU XLPE armored cable |
| 23 | 3C x 4 Sq.mm. CU XLPE armored cable |
| 24 | 3.5C x 25 Sq.mm. Aluminum XLPE armored cable |
| 25 | 4C x 4 Sq.mm. CU XLPE armored cable |
| 26 | 3C x 2.5 Sq.mm. CU XLPE armored cable |
| 27 | Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required- Group C |
| 28 | light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 29 | power plug point modular type accessories: Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 30 | Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 31 | Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 32 | Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 33 | Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required. |
| 34 | Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required upto 450mm sweep. |
| 35 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.5/6 A switch |
| 36 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 37 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required.3 Module (100mmX75mm) |
| 38 | Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the samein case of recessed conduit as required. |
| 39 | 25 mm |
| 40 | 32 mm |
| 41 | Supply, installation, testing and commissioning of following sizes of Heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm |
| 42 | S/L SWG GI wire in ground:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required |
| 43 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 44 | Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner. Approved Makes-OBO/ JEFF/ JMV |
| 45 | 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures:20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make Philips /BN021C LED22S PSU CW GR S2/01 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI,LED Make CREE/Osram/Samsung with LM80report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies |
| 46 | 18W, 2000 Lumen Recess mounted LED Down light fixtures:Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Recess mounted LED Down light fixtures equivalent to Philips make DN296B LED20S- 6500 PSE WH S1 /04 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications.* Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI,LED Make CREE/Osram/Samsung with LM80report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be BLACK OR as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies |
| 47 | WALL MOUNTED LED LIGHT : (MIRROR LIGHT)Supply, Installation, assembling, connection, testing & commissioning of Mirror LED Light suitable for 12W luminaire along with all other necessary accessories. Equivalent to Philips/BN021CLED12S PSU CW GR/02. IP20. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI,LED Make CREE/Osram/Samsung with LM80report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies |
| 48 | LED BULK HEAD LIGHT FIXTURE:Supply, laying, connection and testing of LED bulk head suitable for 12W luminaire along with all other necessary accessories.. * Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 (As per Architect) as per ANSI,LED Make CREE/Osram/Samsung with LM80report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes-Philips/Wipro/K-Lite/Neri |
| 49 | Weather Proof Downlighter : Supply of CEILING LED Fixture -LED 12W,LED Electronic Driver which offers Protection against Short Circuit, Over- Voltage & Over- Current, IP 66 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt ,Dimension-126mm(Dia.)x138mm(H),Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Bega/DW Windsor |
| 50 | Supply, Installation , Testing and Commisioning of 120 W LED Flood Light for application , BIS approved , Body made of pressure Die cast aluminium with separate driver chamber for ease of maintenence, proper fins should be designed for better heat dessipation ,adjustable bracket should be provided to adjust the tilt of light , primary diffuser should be PMMA/PC Lenses for Better photometry and wide area coverage , The secondary diffuser should be clear toughned glass with IK08 protection . The luminaire is provided with internal surge protection of 4 KV .Fixture is having external surge protection of 10KV. Electronic potted driver having power factor>0.95, THD <20 % and input voltage range from 150-270V AC at 50Hz. Minimum lumen 13200 Lumens in CCT range of 5700 as per ANSI,LED Make CREE/Osram/Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.Ambient Operating Temperature is -10 Deg. to 50 Deg. Luminaire should Maintain Ingress Protection of IP66 for better weather proofing. * Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Bega/DW Windsor |
| 51 | Supply of exhuast fan (450mm)Approved Makes-Havells/Usha/Almonard |
| 52 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. |
| 53 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 54 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 55 | Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray cable tray with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders includingG.I. bolts & nuts, etc as required. |
| 56 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 57 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 58 | Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray “bends “ ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. |
| 59 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 60 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 61 | Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray “Tee” ( galvanisation not less than 50 microns) with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from theceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. |
| 62 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 63 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 64 | Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray “Cross member” ( galvanisation not less than 50 microns) with perforationnot more than 17.5%, in convenient sections, joined with connectors, suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. |
| 65 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 66 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 67 | Contractor to design lightening protection system along with SITC work. Contractor also need to submit Risk Analysis report based on site condition and location. Contractor to take soil resistivity report and necessary consideration to be taken along with below items. In general, the complete system design and installations shall confirm to latest IEC/IS Standards and the specifications, drawings submitted here with. Quantity and items mentioned here under is just for reference; Bidder shall be responsible to calculate the exact quantity as per design requirements for each item during bidding. The bidder shall include all necessary accessories to comply the installation and design to IS/IEC 62305 requirements, which broadly includes all system requirement. |
| 68 | Supply, Installation, Testing and Commissioning of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of VDE 0185-305 (IS/IEC 62305) or equivalent as per make. |
| 69 | Supply, Installation, Testing and Commissioning of Roof conductor holder - Polyamide holder with stainless steel base (V2A),Bottom section with Ø8.5 mm slot, Conductor holder @ 1 meter distance distance or equivalent as per make. |
| 70 | Supply, Installation, Testing and Commissioning of cross universal connector: For T and cross connection, Meets the requirements of VDE 0185-305- 3 (IEC/ EN 62305-3).• Fit: Rd 8–10 x Rd 8–10• Mounted with 4 hexagonal bolts M8 x 25 and 4 hexagonal nuts M8. or equivalent as per make. |
| 71 | Supply, Installation, Testing and Commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. or equivalent as per make. |
| 72 | Supply, Installation, Testing and Commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305) (2 Nos for expansion piece) or equivalent as per make. |
| 73 | Supply, Installation, Testing and Commissioning of Folding clamp to hold the round conductor with a diameter of 8 mm to 16 mm.Material : Hot-dip galvanised. OBO Type No. FCAH ( 5450096 ) or equivalent as per make. |
| 74 | Supply, Installation, Testing and Commissioning of 10 mm Copper coated Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305), or equivalent as per make. |
| 75 | Supply, Installation, Testing and Commissioning of For T cross and parallel connectors. Quick SS installation using hexagonal bolt M10X30 high-grade stainless steel. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). or equivalent as per make. |
| 76 | SITC OF 6HOURS BACKUP SOLUTION FOR 20KW OFF-GRID SOLAR POWER PLANTDesign, Supply, installation, testing and commissioning of 6HOURS BACKUP SOLUTION FOR 20KW OFF-GRID SOLAR POWER PLANT.Scope shall include required number of batteries for 6hours back up, DC & AC cabling, DC & AC DBs, Earthing, inverters, conduits and all other require components and accessories to finish the job. All required satutory Approval from respective authority shall be part of Scope. |
| 77 | LT PANELS |
| 78 | Supply, Installation testing & commissioning of medium Voltage sheet steel metal clad, compartmented cubicle Panel board. Detail specification shall be followed. |
| 79 | Shifting of panels from site store to the suitable location. |
| 80 | Assembling and wiring of component supplied separately. |
| 81 | Earthing all components, frame etc. to a common internal earth bar. |
| 82 | Connection, testing & commissioning. |
| 83 | Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge. |
| 84 | Supply, installation, testing and commissioning all accessories, supporting structure, hard ware etc to complete the job. |
| 85 | Supply, installation, testing and commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc. |
| 86 | The rates for the distribution boards apart from the Breakers and instruments shall also include the following : |
| 87 | This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings. |
| 88 | Supporting rigid steel framework. |
| 89 | Cubicle type, 14 gauge CRCA sheet steel enclosed. |
| 90 | Proper bonding to earth. |
| 91 | Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. |
| 92 | Providing cable clamps / supports within distribution boards cable alley. |
| 93 | If any TPN ACB’s / MCCB, it shall be with adequate size of neutral link. |
| 94 | All MCB’s shall be of minimum 10 KA breaking capacity. |
| 95 | The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. |
| 96 | All motor feeders MCCBs shall be of motor duty. |
| 97 | Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. |
| 98 | Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. |
| 99 | IP 4X for all Indoor panel. |
| 100 | IP 54 and double door. |
| 101 | All MCCB’s shall be provided with operating mechanism for door interlock. |
| 102 | All measuring instruments (Meters) shall be of digital electronic with LED of approved make. |
| 103 | All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. |
| 104 | All panels shall have provision of the following: |
| 105 | Pad locking of Switch board doors. |
| 106 | Pad locking of MCCB’s handles in “OFF” Position. |
| 107 | All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. |
| 108 | All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. |
| 109 | SPD as shown in SLD |
| 110 | Aprooved Makes-L&T/ABB/schnider/Legrand/SIEMENS |
| 111 | Supply, Installation, testing and commissioning of IP 54 rated MAIN LT PANEL_FESTIVE GROUND Having,Incomer from SOLAR: 63A FP MCCB ADJUST. TM BASED RELEASE O/L,S/C,E/F,PROTECTION WITH UV,SHUNT RELEASE) (WITH RS-485 PORT) [MOTORIZED] (01 Nos).1 NO SPD (01 Nos).1 NO LOAD MANAGER WITH RS485 PORT1 NO. DIGITAL VOLTMETER WITH VOLTAGE SELECTOR SWITCH1 NO. DIGITAL AMP METER WITH AMETER SELECTOR SWITCHINDICATION LAMP- 6 NOS (R,Y,B,ON,OFF,TRIP)3Nos. CT 63/5A CL-1.0,5VA MECHANICAL & ELECTRICAL INTERLOCKING (BETWEEN BOTH INCOMERS)Incomer from DG: 63A FP MCCB ADJUST. TM BASED RELEASE O/L,S/C,E/F,PROTECTION WITH UV,SHUNT RELEASE) (WITH RS-485 PORT) [MOTORIZED] (01 Nos).1 NO SPD (01 Nos).1 NO LOAD MANAGER WITH RS485 PORT1 NO. DIGITAL VOLTMETER WITH VOLTAGE SELECTOR SWITCH1 NO. DIGITAL AMP METER WITH AMETER SELECTOR SWITCHINDICATION LAMP- 6 NOS (R,Y,B,ON,OFF,TRIP)3Nos. CT 63/5A CL-1.0,5VAOut Going: 63 Amp FP 10KA MCCB (1NOS.)32 Amp FP 10KA MCB (1NOS.)25 Amp FP 10KA MCB (3NOS.)25 Amp DP 10KA MCB (1NOS.)ALSO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 112 | Supply, Installation, testing and commissioning of IP 54 rated EXT. LIGHTING PANEL Having,Incomer: 25 Amp FP 10KA MCB (01 No).1 NO SPD1 NO MFM WITH RS485 PORT1 NO. DIGITAL VOLTMETER WITH VOLTAGE SELECTOR SWITCH1 NO. DIGITAL AMP METER WITH AMETER SELECTOR SWITCHINDICATION LAMP- 6 NOS (R,Y,B,ON,OFF,TRIP)CT, 25/5A, CL-1,10VA AUTO MANUAL SWITCH WITH DUAL CHANNEL DIGITAL TIMER WITH 48HR BATTERY BACK-UP AUTO-MANUAL BY-PASS SWITCHOut Going: F1 - F5 : 16 Amp FP 10KA MCB WITH 16A, FP MG CONTACTOR (05 NOS.)F6 - F12 : 16 Amp DP 10KA MCB WITH 10A, DP MG CONTACTOR (07 NOS.) CONTRACTOR TO REFER SLD & DETAIL TECHNICAL SPECIFICATION ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. |
| 113 | Laying of PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existingRCC/ HUME/ METAL/DWC pipe as required. |
| 114 | Upto 35 sq. mm |
| 115 | SITC of 16A / 20A Single Phase IP66 industrial Plug Point with metal clad plug Socket / plug top with 20A DP MCB including weather proof box cover plate etc, complete in all respect, include switch, box, plate, etc. equivalent to Legrand Make Cat No. 056661 |
| 116 | Wall Recessed LED Step Light : (FOOT LIGHT)Supply,Installation, Testing and Commmisioning of IP68, IK10 protected Step Light Fixture. Fixture made of powder coated die cast alluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.95 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with BISWith Stainless Steel Bracket for Wall Recessed LED Step Light : (FOOT LIGHT)* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Bega/DW Windsor |
| 117 | Landscape BollardSupply, laying, connection and testing of Landscape Bollards 15Watts Bollard LED, IP66, 800/100mm. * Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI/Bega/DW Windsor |
| 118 | FIXTURE - 40-45W Power Module LED: Supply, Installation, assembling, connection, testing & commissioning of post top light fixture equivalent to LED FIXTURE - 40-45W Power Module LED, -MOUNTED AT 4 METER HEIGHT POST TOP POLE :it's - Upper frame made in die-cast and sheet aluminium (thickness: 2.5mm), with threaded coupling G3/4\\" for fixing,Bottom frame with ring made in die-cast aluminium and two arms made in hotgalvanized steel, with flange for fixing equipped of a hole (diam. 28 mm) .Gasket between the upper and bottom frames.Painted with polyester powder coating in Metallaic Grey (As per Architectural requirement). IP Rating - IP 66.Height –690mm, Dia - 550mm, Weight - 11.5Kg, Area Exposed to Wind(S) - 0.105 m2. Power LED's Module (with CREE/NICHIA/OSRAM/SEOUL SMD type LED’s with ESD=>8kV & Ceramic package are accepted. LED manufacturers tech sheet with buying documents should be submitted for verification. Individual LED's Minimum Luminous Flux (lm) is 139lm @ 350 mA (@ 85 °C) same should be supported by LED manufacturer's tech sheet) in compliance with IEC 62031(supporting type test report should be submitted), on Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 1.5kv(an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens (Polycarbonate), UV Resistant & Shock Resistance IK10.LM80 Reported LED Lifetime is L90@ 50,000hours minimum.(same should be supported by LM 80 report from NVLAP accredited lab) & Estimated LED Lifetime is L80 @ 100,000 hours(Ta-25°C) minimum..LM 80 report & TM 21 calculation should be submitted to support the same.The Light fixture shall be in compliance with IEC 60598-2-3; IEC 60598-1.(Supporting Test Report from NABL accredited Laboratory should be submitted) .LM79 report should be submitted from NABL accredited Laboratory. * Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI / BEGA / HEPER |
| 119 | Supply, Installation, assembling, connection, testing & commissioning of ARCHITECTURAL POLE (FOR POST TOP LIGHTING) 3.3M height Pole (Total height of the pole is 4m including post top) Made in combination of hot dip galvanised mild steel pipe sections 114mm dia. & 140mm dia. Arch. cast iron Base design starts with min 322mm Dia. ring, radially tapers to 140 mm for a height of min 235 mm matching to the drawing. Total weight of the base is min 15 Kgs. Decorative Ring-1 (140/114mm dia. – min 3kgs.) & Top Ring (weight- 3kgs.) are made of cast iron. Entire pole shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box (Concealed) to fix 32A connectors and 6A MCB (to terminate incoming and outgoing armoured cables with glands and lulgs), at the bottom -the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & it's parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint- customised colour Metallaic Grey (As per Architectural requirement). Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge. Scope also includes necessary foundation, cable termination, earthing as per requirement, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc. all require to complete job. * Colour of Pole shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Make - NERI / BEGA / HEPER |
| 120 | 35W LED Solar Streetlight:Supply of all in one integrated LED solar streetlight consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, Inbuilt Sensor, inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar street light with IP65 ingress protection having a system wattage of 35W with 6000 lumen output, 60Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, 30 Ah IP68 Lithium Ferro Phosphate(LiFePO4) battery with proper battery management system. LED lumen efficacy shall be at least 175lm/W and LED driver should have >90% efficiency. Typical correlated colour temperature should be 3000/5700K with CRI>70. It should ensure battery optimisation with help of a suitable dimming profile. The luminaire shall have inbuilt hybrid power supply option that can charge the battery during non sunny days automatically from the grid. The luminaire should be housed in IK 08 impact resistance certified aluminum pressure diecast housing with anti- corrosive coating and must have a UV stabilized polycarbonate cover. The luminaire shall have a specially designed pole mounting piece that enables lateral as well as post top mounting and installation at varying tilts from 0 to 15 degrees for optimal light distribution.* Colour of light fixture shall be as per Architectural requirements.* Contractor to submit samples for Approval before ordering the fixture.Approved Makes-Philips/Wipro/Havells |
| 121 | Supply, erection testing and commissioning of 5M HEIGHT SINGLE ARM OCTAGONAL POLE 5M height Single arm Conical Pole made in combination of Octagonal Conical section which is fabricated from High tensile MS Sheet(3mm thick) with top 48 to 60mm A/F and bottom 130mm A/F. Arm made of steel pipe section 60mm dia.( horizontal) to get 1000mm arm length & pleasing aesthetics. The pole to be provided with a steel base plate of 200mmx200mmx12mm thick minimum. This mounting steel base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. Entire pole & bracket shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole strength. Pole & it's partsare painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint.* Colour of Pole shall be as per Architectural requirements.Approved Make - NERI/Transrail / Bajaj / Volmont |
| 122 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE |
| 123 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1610 G/OBO/CAPE |
| 124 | Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1616 G/OBO/CAPE |
| 125 | Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes (300mm(L) X 300mm(B) X 170mm(H) with connector & including GEL. Equivalent to Hensel catalogue no MI 0201/OBO/CAPE |
| 126 | Supply, Transportation, Installation, testing and commissioning of IP 68 weather proof Outdoor type junction boxes (225mm(L) X 295mm(B) X 122mm(H) with connector & including GEL. Equivalent to Hensel catalogue no KF 3500 C/OBO/CAPE |
| 127 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. |
| 128 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 129 | Providing & Laying of HDPE Pipe 32mm PE-80,PN6 direct in ground; to be laid 75-100cm below the ground level for drawing of cables including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering,or G.I. conduit 32 mm dia( Heavy Duty) with concrete block 15cm X 15cm 1:2:4 with complete curing with splicing complete in all respect complete in all respect. Make: Jain/Dutron/Supreme/reliance |
| 130 | DG SET |
| 131 | Supplying and erecting, commissioning and testing diesel generating set having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply comprising of a totally enclosed air/water cooled diesel engine with multi-cylinders developing suitable BHP not less than following capacity at 1500 RPM with 10% overload for one hour in 24 hours with standard accessories like fly wheel, lubricating oil cooler, \\"A\\" class governor, heavy duty fuel wheel and lubricating oil filter, oil bath air filler, lubricating oil pressure gauge, end exhaust manifold, standard set of tools with adjustable spanners, screw drivers, feeder gauge, cylinder head to cover, joint cylinder head to exhaust, element lube oil filter, 12/24 volts electric starting equipment complete with standard battery, dynamo, cut-outs, ammeter, necessary wiring, pressure gauge, starter etc and heavy duty Residential type exhaust silencer and vertical hot air duct both acoustic enclosure.logged with asbestos rope, save oil trays, exhaust piping of required length, standard wall/floor mounted fuel with level indicator and piping and drip proof alternator, self excited, self regulated, screen protected, with excitation system, capable of delivering the rated system output at 415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with voltage regulation +/- 5% of rated voltage from no load to full load. Both the engine and alternator fitted on a common fabricated steel base plate with antivibration mounting engine and alternator both connected to each other by flexible flange coupling and with floor/wall mounted control panel box comprising of voltmeter ammeter, selector switches, ACB / MCCB / MCB of adequate capacity, indicator lamps duly wired with HRC fuses. The alternator & control panel shall be connected with provided suitable capacity armoured cable and complete with Acoustic enclosure (canopy) made out of 18 SWG CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick conforming to IS:8183 The resin bonded rockwool covered from inside the canopy by perforated sheet with 3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per PVCT norms. Erection, commissioning and satisfactory testing as per requirement with first filling of fuel, oil, etc. with guarantee of complete system for One year. & with obtaining all necessary certificate from Electrical Inspector. The Capacity and Ratings of DG sets are as below. Scope also includes as per below:To submitt drawing showing , overall lay out with dimensions, plan, elevations an sections and got approved prior to commencing of manufacturing.To submit drawing showing, SLD with rating of equipemnts / make etc., and got approved prior to commencing of manufacturing. DG SET should be complied as per latest CPCB Norms. |
| 132 | The scope includes to test the DG set for factory test witnessed by Owner represantative prior to dispatch of following:-1. Load trial test for equal ratings of load for continous 4 Hrs.2. Sudden shock load at every One hour during above test.3. Vibration Test 4. Noise level test.5. Fuel gas analysis. 6. Delta ` t ' inside acoustic enclosure.(2) Delivery of the DG set at site. (3)Specific Fuel Consumption Test. (4) Unloading of the DG set at Required Location of Installation & test at manufacture's place.(5) Technical support & supervision during commissioning of DG Set & Synchronizing Panel. (6) To get Battery charged and to test Battery charger.(7) Testing of the DG Set with Supply of Consumable. (8) Painting of the parts damaged during Transportation or Installation. (9) Power & Control cabling between D.G. Panel & D. G. Set, syncronising Panel & alternator to ACB/MCCB inside the enclosure.(10) D.G. set should have exhaust chimney of Suitable Length (AS PER LATEST CPCB NORMS/LOCAL NORMS) as per statutory requirement with suitable M.S. structure complete between exhaust of engine till out let point for discharging fuel gas. Drawing of which should be submitted for approval.(Necessary cost to shall be included.) If required Contractor has to visit site and accordingly rate shall be included.(11) The rate quoted shall be for the entire job including exhaust piping complete up to trial test. No extra rates to be quoted for any items for the DG set.(12) The day tank must be part of acoustic enclosure. No external fuel tank required.13) All Necessary control cables of between DG set, AMF panel/Sync Panel, MLTP and Battery charger shall be part of supply. Necessary BOM shall be submitted during approval process.14)To prepare & submit as-built drawing and handing over document to end user.15) Scope also includes preparing necessary drawing submitting to authorities, getting their approval / sanction and final certificate including NOC from pollution board(if required) to energize the D G Set.16)DG vendor has to arrange for inspection and factory acceptance test as detailed in specification. The Item shall include TO and FRO travelling economy class Air ticket/second class AC/Air-conditioned car, whichever feasible from the port of boarding of client/consultant lodging/boarding as necessary for at least three representatives of client/consultant.(Suitable up to 3800m Altitude) |
| 133 | Supply of Prime duty 40 KVA DG set, acoustic enclosure suitable for 75 db(A) sound level reduction to be measured at 1 mtr. from the enclosure. Cost should cover D.G. set control panel, necessary control and metering, control & power wiring, indication /annunciation & other accessories. (DG SET Shall be worked Satisfactory at 3800m Altitude)Approved Makes-SUDHIR/JACKSON/ STERLING |
| 134 | Providing & erecting approved make AMF control panel suitable for following size of 3 phase, 415 V, 50 cycles, A.C. diesel generating set along with required MCCB protection complete of scope as detailed below: 1) Power module: A pair of electromechanically interlocked contactors (for mains & generator) Overload relay for generator contactor Neutral contactor for mains and generator Power socket for connections.2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items attempt start facility. Air circuit breakers/MCB/MCCB of suitable rating for auto/manual operation. Auto/manual switch. Emergency stops push buttons. Manual start push button. frequency meter. Engine hour meter. Two earthing studs.3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High cylinder head temperature. V belt failure.4) Indicators with alarm Load on generator.5) Indicators Load on mains Engine fails to start . Emergency stop battery charger.The AMF Panel of following capacity(Suitable up to 3800m Altitude)AMF Control Panel for 40 KVA, 3 phase DG Set Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail