| 1 | Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Polycab/Finolex/Eq Make to be approved by EIC) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider/ Havells/ Legrand/Anchor roma plus/ABB/Eq Make to be approved by EIC & along with 2.5 Sqmm (P+N+E) Circuit Wire of same make as mentinoned above & items shall be approved before execution of work by EIC/SDO. |
| 2 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/ Anchor/ Schneider /ABB/Eq Make & shall be approved before execution of work by EIC/SDO. |
| 3 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor/Eq Make to be approved by EIC) |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Legran/Anchor roma plus/ Schneider/ ABB/Eq Make & shall be approved before execution of work by SDO. |
| 5 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor/Eq Make to be approved by EIC) |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus/Schneider/ABB/Eq.Make & shall be approved before execution of work. |
| 7 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/ Eq.Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) |
| 8 | 2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 9 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for machine point Sub main in One run from Main Panel to Distribution Boards. |
| 10 | 2 X4 sq. mm + 1 X4 sq. mm earth wire forLighting point Sub main in One run from Main Panel to Distribution Boards. |
| 11 | 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire for inverter circuit wire |
| 12 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/Havells/ABB/Eq Make to be approved by EIC) |
| 13 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ Havells/ ABB/ Eq Make to be approved by EIC) |
| 14 | 40Amp. |
| 15 | 63Amp. |
| 16 | Supplying and Fixing of MCB 6 way (4 + 18), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make to be approved by EIC) |
| 17 | Supply/Installation/Testing and Commissioning of 18W + LED Conceal (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of three years,which includes replacement of fixtures of Philips/ Havell's/ Wipro/ Jaquar/ Eq Make to be approved by EIC |
| 18 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips/ Eq Make to be approved by EIC as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of three years reckoned from date of successful commissioning /handing over of site to intending department. Havells/Philips/Wipro/Eq.make to be approved by EIC |
| 19 | Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. Compt 225-250mm Shutter Typed of Usha/Polycab/Anchor/Eq Make to be approved by EIC |
| 20 | Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Anchor/Crompton Greaves/ Polycab/ Eq Make to be approved by EIC.(Minium 1-Star) |
| 21 | Supply/Laying/Connecting and Commissioning of 95 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq Make to be approved by EIC with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) |
| 22 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens/ Eq Make to be approved by EIC and change over switch should be of Havells/ L&T/Legrand/ Schneider /Eq Make to be approved by EIC(1) Normal Incomer:a) 250Amp-4-Pole ,36kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider/ Eq Make to be approved by EIC as approved=01 No. b)400 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.100 Amp four pole Manual Changeover of Havells/ L&T/Legrand/ Schneider /Eq Make to be approved by EIC.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 40-Amp DP MCB = 04 No. as per site requirement)(b) 63-Amp DP MCB = 04 No. as per site requirement)c) 32-Amp DP MCB = 05 No. as per site requirement) |
| 23 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testinq and commissioninq etc. as required. |
| 24 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job |
| 25 | Supply installation testing and commissioning of Sine Wave Inverter of Capacity 10 KVA ( Plus), supporting 8 batteries 200Ah with minimum 2 hour back-up at full load,24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes ,MCB for protection from Input mains,Bypass switch for supplying output directly from grid in case of Home UPS fault.Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc.Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF) preffered make Luminous/ Microtek/Exide.the job also includes angle iron stand for housing 8 No of battries and inverter. |
| 26 | SITC OF 1.5 TON 3-star AC DC inverter technology hot and cold air conditioner of LG/Daikan/Mitsubushi/Eq Make to be approved by EIC.The job further includes providing and fitting of indoor unit on wall by employing suitable clamps and outdoor units on angle iron stand for holding of out door unit fitted with nuts and bolts, laying of refrigerant copper pipiing upto 3 mtrs, wherever needed, insulating the copper pipeline with nitrilic foam, topping up with refrigeant for additional length of piping etc. complete.The job also includes P/f of pvc flexible drain pipe of length 12 mtrs alongwith fitting, servosatbiliser suitable for 1.5 ton ac.The job includes AMC of AC for aperiod of two years from date of sucessful commissioning.It also includes the required voltage stablizer of reputed make and 32 Amps DP MCB with box complete Job. |
| 27 | Supply, installation, testing & commissioning of CAT-6 LAN point comprising CAT-6 UTP cable (23 AWG solid core), CAT-6 I/O information outlet, faceplate, surface box, 1-meter patch cord, complete with laying through PVC conduit/casing capping, termination at both ends, labeling, and testing using LAN tester. All materials to be ISI/BIS marked (D-Link/ Molex/ Schneider/ Eq make as directed by SDO) |
| 28 | Supply and installation of 24-port CAT-6 Patch Panel, fully loaded, for rack mounting, with labeling strip and suitable cable management (D-Link/ Molex/ Schneider/ Eq make as directed by SDO) |
| 29 | Supply and installation of 24-Port Gigabit Network Switch (Unmanaged), non-PoE, rack-mountable, suitable for small enterprise network.Make: D-Link DGS-1024C / TP-Link SG1024D or equivalent as directed by EIC |
| 30 | Supply and installation of 9U wall-mount network rack, complete with locking glass door, fan, 6-socket power distribution unit (PDU), cable manager, hardware and mounting accessories.Make: Netrack / Valrack / Netfox or equivalent as directed by EIC |
| 31 | Supply of factory-crimped CAT-6 patch cords (2 meters) for switch-to-patch panel connections.Make: D-Link / Legrand / Digisol/ equivalent make as directed by EIC |
| 32 | Power supply wiring for switch rack, including flexible wire, socket outlet, and installation up to nearby power source, all complete. |
| 33 | Testing, commissioning, labeling, documentation of complete network with LAN tester and cable mapping tools, including test reports. Please Enable Macros to View BoQ information |