| 1 | Excavation in Foundation in ordinary soil including lift upto 1.5 metre and lead upto 30 m and including filling watering and ramping of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in- Charge upto a distance of 30 m from the foundation trenches. |
| 2 | Earth work in cutting or in filling in ordinary soil excavation to be in the form of regular pits not exceeding 1/2 metre 20\\" in depth andd earthwork in embankment to be in 20 cm layers including ramming and dressing the surface to required level and slopes and also including 1.5 metre lift and 30 m lead the earth from cutting to be used in making filling or to be deposited as spoil bank within 30 metres distance as directed by engineer in charge. |
| 3 | Sand filling in plinth including suppty of necessary quantity of sand from a distance not exceeding 8 km.(5 miles) from the site of work and including watering, dressing etc. Rate to including cost of all materials , labour and T&p etc. |
| 4 | Cement concrete with 4 cm gauge approved stone ballast approved coaarse sand and cement in the proportion of 8:4:1 incluning supply of all materials labour and T&P etc. required for proper completion of the work |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:1791 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. |
| 8 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work. |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | half brick masonry with common burnt clay FPS bricks of class designation 7.5 in superstructure above plinth level up to floor v level. |
| 12 | Reinforced cement concrete work (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form work. |
| 15 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration |
| 16 | 15 mm thick cement plaster 1:6 in two coats work in external plaster |
| 17 | 12.5 mm thick cement plaster 1:4 in internal plaster |
| 18 | Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm,which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). |
| 19 | Providing and laying Marble stone flooring with 18 mm thick, rissers of steps ,skirting ,dado 10 mm thick in base of cement mortar 1:4 laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing complete. |
| 20 | Providing and laying kota slab 20 mm flooring, rissers of steps ,skirting ,dado 10 mm thick in base of cement mortar 1:4 laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing complete. |
| 21 | Providing and laying Ceramic glazed floor tiles of size 600x600 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm includingpointing the joints with white cement and matching pigment etc.,complete. |
| 22 | Providing and laying vitrified floor tiless in different size with water absorption less than 0.08% and conforming to IS:15622 of approved less 20 mm thick in base of cement mortar 1:4 laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing complete. Glazed vitrified tiles Matt/Antiskid finish of Size 600 x 600 mm. |
| 23 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 24 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete. |
| 25 | Finishing wall with water proofing cement paint of approved make and quality on new work with two coat give an even shade. |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 27 | Providing and fixing angle iron frames for doors, windows and ventilatorsof mild steel angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge. |
| 28 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 29 | Providing and fixing ball bearing for rolling shutters |
| 30 | Extra for providing mechanical device chain and crank operation foroperating rolling shutters. |
| 31 | Extra for providing grilled rolling shutters manufactured out of 8 mm diaM.S. bar instead of laths as per design approved by Engineer-in- charge |
| 32 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 5.0 mm thick glass panes (weight not lessthan 12.50 kg/sqm). |
| 33 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :(Flat back wash basin of size 550x400 mm) |
| 34 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 35 | White glazed earthenware european type wc pan with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fitting and ci brackets 40 mm flush bend overflow arrangement with specials of standard make it complete. |
| 36 | Providing anf fixing 8 mm dia C.P/ S.S jet with Flexible tube upto 1 metre long with S.S triangular plate to european type WC of Quality and make as approved by Engineer in charge. |
| 37 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete.10 litre capacity - range of four urinals basins with white PVC automatic Flushing Cistern. |
| 38 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 39 | Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stoneslab table rubbed, edges rounded and polished, fixed in urinal partitionsby cutting a chase of appropriate width with chase cutter and embeddingthe stone in the chase with epoxy grout or with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominalsize) as per direction of Engineer-in-charge and finished smooth.White Agaria Marble Stone |
| 40 | providing and fixing toilet paper holder |
| 41 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 42 | Providing and fixing C.P. brass angle valve of approved quality conforming to IS:8931 : |
| 43 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles, including applying a priming coat of approved steel primer. |
| 44 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.1-Providing and fixing of bend of required degree with access door |
| 45 | Providing and fixing of plain bend of required degree |
| 46 | Providing and fixing of collar |
| 47 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 48 | Providing, Laying , fixing soil, waste and vent pipes 100mm dia sand cast iron S&S pipe as per IS :1729 jointing and testing complete as per specifications.1-100mm o/d pipe of 10 Kgf. / sqcm |
| 49 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 50 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 51 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.With common burnt clay F.P.S. (non modular)bricks of class designation 7.51-CPVC SDR 11 Pipe & fitting 20mm o/d |
| 53 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 54 | Providing and fixing overhead signage board |
| 55 | Construction of Septic tank |
| 56 | Construction of Soak pit |
| 57 | Rain water harrvesting |
| 58 | Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1-Group C |
| 59 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 60 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.1-2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 61 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 62 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required.1-20 mm |
| 63 | 25 mm |
| 64 | 32 mm |
| 65 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 66 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc as required |
| 67 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 68 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1-Module (100mmX75mm) |
| 69 | 12 Module (200mmX150mm) |
| 70 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 MM Sweep |
| 71 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 72 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.1-62 A TP&N |
| 73 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.1-Double pole |
| 74 | Triple pole and neutral |
| 75 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.1-63 A |
| 76 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 77 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 78 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 79 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 80 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, inter connections as required. |
| 81 | Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. asrequired.1-15/16 A switch |
| 82 | 6 pin 15/16 A socket outlet |
| 83 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 84 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 85 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 86 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 87 | Supply installation testing & commisning of capacity passenger machine room lift with re generative drawing as per C.P.W.D general specification for electrical work(Part 3rd lift & ascaleter) BIS code NBC. 2016 Please Enable Macros to View BoQ information |