| 1 | AEROSOL BASED FIRE EXTINGUISHERSSupply & Installation 8 gm Portable Aerosol based Automatic Fire Shield (Coverage: 0.08 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 2 | Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 3 | Supply & Installation of 30 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 4 | Supply & Installation of 60 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.6 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 5 | Supply & Installation of 100 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 1 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 6 | Supply & Installation of 200 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 2 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 7 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 8 | Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. MakePyrogen/Firepro/Stat-x/Equivalent |
| 9 | Supply and Installation of linear heat detection cable compatible with aerosol based fire extinguisher as per direction of Engineer-in-charge.Make-Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 10 | Supply, installation, testing and commissioning of Medical IT System for as per IS 17512 Intensive care unit/ OT:Incomer :63A Auto change over switch -1 No. 63A DP MCB 10kVA with On / Off Indicator - With 16Sqmm Terminals N.B.: panel should be placed within 25 meter from icu /ot Medical isolationTransformer : 10 kVA Rating Medical Isolation Transformer with Copper Windings. The leakage current from the output winding to earth and the enclosure, measured at no-load condition with rated voltage and frequency, must not exceed 0.5 mA as per IEC61558-2-15 - 1 Nos, Primary Side : Single Phase 230v, Secondary Side : 230v.Monitoring Devices :1. Medical Insulation Monitoring Device (MED-IMD) Tested as per IEC 61557-8 with storage of up to 100 Incident Logs, RS 485 for Communication, Overload and Temprature for Transformer Measurement and Indication as per the set values. The injected current, even under fault conditions, must not exceed 1 mA peak. The a.c. internal impedance must be at least 100 kΩ. An alert must be triggered when insulation resistance drops to 50 kΩ. The test voltage should not exceed 25 V d.c.2. Fault Locator (MED-IFLS) for each outgoing channels as per IEC 61557-9 to locate and identify the circuit (6 channels) - 2 Nos.3. PE conductor monitoring system(PECM) to identify the PE conductor status (6 channels) - 2 Nos.The panel should provide visual alerts via LED indicators and sound alerts for issues such as insulation level faults, overloads, temperature alarms, and protective earth continuity problems, with a green lamp for normal operation and a yellow lamp that lights up when the minimum insulation resistance value is reached.An audible alarm also must sound when the minimum insulation resistance value is reached. This alarm may be silenced manually, but the yellow signal lamp must remain lit until the fault is corrected. The system panel must display key information, including insulation levels, load, and temperature values in the display unit. one extra alaram near nurse station .Outgoing : 12 x 16A DP C Curve MCB4 Sqmm Terminals - 48 NosPanel enclosure is constructed from 16SWG thick galvanized sheet steel providing a durable and rigid framework. Panel shall be Powder-coated in RAL7032 texture for protection against environmental factors. Doors are made of 16SWG CRCA sheet steel hinged with a 120-degree opening and reversible installation (left or right). A 3-point locking mechanism enhances security and ease of use, and the design shall include removable top and side covers with double-bent edges for extra strength. Make:- Schneider/ Cape/ ABB/ Siemens |
| 11 | Supplying and fixing 40Amps 2P 240 volts AFDD+MCB(arc fault detection device) Make-ABB S ARC1 M/Equivalent model of Schneider/Legrand/Siemens ,10KA,C series,1PH+N,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year |
| 12 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. Please Enable Macros to View BoQ information |