| 1 | AEROSOL BASED FIRE EXTINGUISHERSSupply & Installation 8 gm Portable Aerosol based Automatic Fire Shield (Coverage: 0.08 m3), EN 15+B3:B45276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 2 | Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 3 | Supply & Installation of 30 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 4 | Supply & Installation of 60 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.6 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 5 | Supply & Installation of 100 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 1 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 6 | Supply & Installation of 200 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 2 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 7 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 8 | Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent |
| 9 | Supply and Installation of linear heat detection cable compatible with aerosol based fire extinguisher as per direction of Engineer-in-charge.Make-Make- Pyrogen/Firepro/Stat-x/Equivalent |
| 10 | Lightning Arrester :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 11 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 12 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 13 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 14 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 15 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 16 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB |
| 17 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 18 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 19 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 20 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 21 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 22 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 23 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 24 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 25 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 26 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 27 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 28 | Supply of lightning counter- to count no. of lightning strike and it can record the date andtime of the lightning incident also tested as per IEC 62561-6 in complete as per the direction of Engineer-in-charge.Make-OBO/Dehn/ABB |
| 29 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 30 | Supply, Installing, Testing and Commissioning of VANE AXIAL FANS as per specifications stated below. Fan shall be direct driven Vane axial fan , IP55, AMCA Certified (For Air and Sound Performance as well as FEG). The fan shall be equipped with mounting bracket, inlet guard (If required) & spring isolators for the installation of the fans. Motors shall be VFD Compatible suitable for 415+10% volts, 50 cycles, 3 phase AC supply. Fan static pressure shall be as indicated but actual fan static pressure to be checked by HVAC / MEP Vendor. Supply Fans shall be activated from fire signal from fire alarm system. Fan shall be with fire proof flexible connection at outlet. Motors shall be of minimum IE2 efficiency, class F insulation. Fan total efficiency should not be less than 72% and FEG should not be less than 85, noise level should not be more than 84 dB(A) @ 3m distance when measured in hemispherical reverberant room conditions. Sound attenutors of appropriate length shall be included in the cost to achieve the desired result.The differential pressure should be maintained as per NBC 2016. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Krugger/Nikotra5500 cfm, 20 mm Static pressure for Lift well |
| 31 | 6000 cfm, 20 mm Static pressure for Lift well |
| 32 | For smoke exhaust: SITC of Tube/vane/inline-axial direct driven Smoke exhaust fan as per BS EN 12101-3 complete with cast aluminium impeller and all standard accessories like drive motor suitable for handling hot gas of temperature 400 Deg C for 2 hours, motorized isolating damper at fan inlet, rain protection cowl with bird screen/back draft damper at fan discharge, supports and supporting structures, for 4 point clamping with Vibration spring isolater and Motorized damper shall be rated for 240 V, 50 Hz, 1 Ph., AC supply.The Motor shall be of TEFC, IP-55 protection, Class 'H' insulation, motor shall be of IE-3 efficiency, suitable for 3 Phase, 415volts, 50hz power supply.Fan Shall be Oprating in Dual Mode in Normal Ventilation & another in Fire ModeFan Make - Krugger/Nikotra/Systemair/Greenheck/humidin/Airflow/ELTA2500 CFM at 25 mm WC |
| 33 | Supplying, Fixing, testing and commissioning of Motorized fire dampers of minimum 120 minutes fire rated as per UL-555 and UL 555S,leakage class-1 in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized operated by AC/DC Actuator and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required. The damper housing of Galvanised Steel sheet construction, 16G GI casing and 16G GI Blades with chrome plated spindle, self lubricating bushes. The damper blade should be Heavy duty interlocking blades and fully enclosed blade linkage mechanism. (Make: Air Flow/ Systemair/ Dynacraft/Greenheck)Fire damper(150 mm deep) |
| 34 | Supply, installation, testing and commissioning of an electric spring-return actuator comply with UL 555 and UL 555S for fire and smoke dampers,UL listed, rated for 2-position (On/Off) control. The actuator shall be factory-fitted with an internal spring to ensure automatic closure upon power loss. It must include dual auxiliary switches for status monitoring (Open/Closed), a thermoelectric tripping device (72°C), and be rated for elevated temperatures (up to 350°F / 177°C). Operating Voltage 24V DC/ 230V AC. Complete with all necessary linkages, mounting brackets, and control wiring as per approved technical specifications. Torque rating as per final damper size with in 3Nm to 20Nm.The rate is inclusive of control panel and temperature response device and its wiring. (Make:- Belimo/ Siemens/ Danfoss) |
| 35 | Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, wall mounted control panels including anchoring into the wall, wiring and earthing terminating into MPCB in each panel shall be provided by the electrical contractor.All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BMS. All starters shall be provided with potential free Contact for Connections to Building Automation System.Over-load relay, suitable for motor duty and able to withstand fault level of suitable KA rating.single phase preventer (Electronics type) as per the ratings given below.Terminal block for power distribution.Power Contactor.Phase indicating lights and indicating light for ON/OFF/TRIP status phase sequence relay shall also be provided.Time delay relay for delayed automatic restart of motor (0-180 sec).Integration with fire alarm detection system and fire damper for starting / stopping the fan (in case of fire) / Power supply for damper control panel.For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation.All starters shall be provided with suitable potential free contract for connections to the Building Automation System.The number of control panels shall be as follows.Make (Switchgear) - ( MCCB : Make-Legrand-(DPX3)/Schneider-(CVS)/Siemens-(3VA) /ABB (Formula), MCB : Make-Legrand-(DX3)/Schneider-(Acti9)/Siemens-(betagard)/ ABB (SB200)Make of VFD-Siemens/Schneider/ABB16/25/32/63A 4P MPCB with 5/10/15 HP Three phase VFD with bypass star delta/DOL starter with overload relay and single phase preventer . Each of these compartment shall contain indicating lamp with ON/ OFF/ TRIP status for fan sections/axial fans.The price is inclusive fire control relay module. |
| 36 | Supply and fixing of emergency pushbutton for remote start and stop of smoke exhaust fan infront of ICU, SNCU, New born and other Critical care units. |
| 37 | Supply, erection,testing & Commissioning of GI Ducting (180 GSM) fabricated at site,complete with turning vanes,collars,reducers as per IS - 655 (CLASS-VIII).Make-TATA/SAIL/JINDAL22 G (0.8 mm) |
| 38 | 20 G (1 mm) |
| 39 | S/I/T&Commissioning of CPRI Approved LT Outdoor floor mounted cubical type electrical pressurization panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge.20x10mm separate aluminium earth busbar is to be provided.ON/OFF/TRIP indication for all the feeders is to be provided.Mandatory provision of cable alley is to be given. In commer- 01 number of 200 Amps 4P TMR MCCB,25KA, Ics=100%Icu Busbar- 04 numbers of 250Amps Aluminium busbar duly sleeved by color coaded PVC sleeve and 01 no. busbar for Earthing & supported by suitable size DMC insulator Out going- (i) 63A,16KA 4P TMR MCCB, Ics=100%Icu, 8 nos (ii) 63A 4P MCB, C series, 10 kA- 2 nos Instrument- (i) phase indicating lamp with HRC fuse for the incomer.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) 01 set of 40KA TYPE 2 3P+N SPD along with 63A 4P MCB C series, 10 kA.Make of MCCB-Legrand(DPX3)/ABB-Formula/Schneider-CVS/Siemens-3VAMake of MCB-Legrand(DX3)/ABB SB200/Schneider-Acti 9/Siemens-BetaguardMake of SPD-Legrand/Siemens/Schneider/ABB/OBO/DEHN |
| 40 | Supplying, installation, testing & commissioning of addressable fire control module complete as required.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider |
| 41 | Supply of 95 sq.mm 3 & 1/2 core XLPE Aluminium FRLS Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/Finolex/Gloster) |
| 42 | Supply and laying of 6 sq.mm 4 core XLPE copper FRLS Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/Finolex/Gloster) |
| 43 | Laying and fixing of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required. |
| 44 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 45 | Supplying and laying of 6SWG GI wire ISI marked on surface or in recess for connection etc as required. |
| 46 | Supply ,installation ,testing & commissioning of 30KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 40 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD ) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 47 | UPS O/G PANEL : S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for EMERGENCY circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. Incomer- 02 no 100 A 4P MCCB 25kA ,adjustable thermal, Ics=100%Icu with on/off trip indication. Make-LEGRAND-DpX3 / Siemens-3VA/ Schneider- CVS/ABB FormulaBuscoupler- 01 no. 100 A 4P MCCB 25kA ,adjustable thermal, Ics=100%IcuBusbar- 04 numbers of 200Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.Out going- 5 numbers of 63A 4P MCCB 16kA ,adjustable thermal, Ics=100%Icu LEGRAND-DpX3 / Siemens-3VA/ Schneider- CVS/ABB FormulaInstrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB) with CTs 100/5A 3 nos class 1 type |
| 48 | UPS Floor panel: S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for EMERGENCY circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. Incomer- 01 no 63 A 4P MCCB 16kA ,adjustable thermal, Ics=100%Icu with on/off trip indication. Make-LEGRAND-DpX3 / Siemens-3VA/ Schneider- CVS/ABB FormulaBusbar- 04 numbers of 100Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.Out going- 4 numbers of 40A 4P MCCB 16kA ,adjustable thermal, Ics=100%Icu LEGRAND-DpX3 / Siemens-3VA/ Schneider- CVS/ABB FormulaInstrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB) with CTs 100/5A 3 nos class 1 type |
| 49 | S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for EMERGENCY circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. Incomer- 01 no 63 A 4P Changeover with on/off trip indication. Make-LEGRAND/ Siemens/ Schneider/ABBBusbar- 04 numbers of 100Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.Out going- 4 numbers of 40A 4P MCCB 16kA ,adjustable thermal, Ics=100%Icu LEGRAND-DpX3 / Siemens-3VA/ Schneider- CVS/ABB FormulaInstrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB) with CTs 100/5A 3 nos class 1 type |
| 50 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 51 | Supplying and fixing 40Amps 4P 415 volts, MCB, 10 kA, C series Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year |
| 52 | Supplying and fixing 40 Amps rating, 4P RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 53 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 54 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 4core x 16 sq mm |
| 55 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 56 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) Please Enable Macros to View BoQ information |