| 1 | Taking down carefully aluminium point wiring light, fan, sockets or power complete from surface wiring or from concealed wiring without disturbing concealed conduit including fittings such as ceiling rose, light fittings of any type, fan regulators etc and making good to the disturbed surfaces wall ceiling floors to match existing surfaces. |
| 2 | S & F Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated unsheathed 1100 V grade cable including 1.5 Sqrnm copper conductor multi stranded PVC insulated unsheathed cable for earth continuity conductor in and including PVC casing and capping/conduit with all accessories and l.2mm thick PVC bóx with 3 mm uniform thick laminated ISI marked sheet cover for mounting of switches sockets regulators etc complete for one light point, controlled by one switch /5 amps one way one fan point controlled by one switch and regulator / one socket outlet point three pin 5 amps. |
| 3 | All as per item No.2 above but with 2.5 sqmm cable for socket outlet 3 pin 15 Amps on independent board incl 2.5 sqmm PVC standard copper conductor cable as earth continuity conductor . |
| 4 | All as per item No.2 above but one staircase light control by 2 Nos two way switch. |
| 5 | S & F in repair switch piano 6 Amps one way flush type |
| 6 | S & F in repair switch piano 6 Amps two way flush type |
| 7 | S & F in repair switch piano 16 Amps one way flush type |
| 8 | S&F in repair socket, 2 in 1, 3 pin 5 Amps flush type |
| 9 | S&F in repair socket 2 in l, 3 pin 6 Amps and 3 pin 16 Amps flush type. |
| 10 | S&F in repair Switch socket combination , 2 in 1, 5 pin 6 Amps flush type with Box All as specified and directed . |
| 11 | S&F in repair Switch socket combination 2 in l, 5 pin 6 Amps/ 16 Amps flush type with box all as specified and directed . |
| 12 | S&F in repair PVC Box suitable for Switch socket 5 Amps combination with 4 hole all as specified and directed . |
| 13 | S&F in repair PVC Box suitable for Switch socket 16/20 Amps combination with 4 hole all as specified and directed . |
| 14 | S&F Socket top ,16 Amps ,3 pin all as specified and directed . |
| 15 | S&F in repair Call bell (Ding Dong Type), AC 230 VoIt, single pole 230V |
| 16 | S&F Lamp holder,Angle and batten type, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and directed . |
| 17 | S& F Sunmica plate of size 50 mm x 50 mm suitable for Switch socket 5 Amps combination all as specified and directed . |
| 18 | S& F Sunmica plate of size 70 mm x 50 mm suitable for Switch socket16 Amps combination all as specified and directed . |
| 19 | S&F in repair of bell push 5 Amps single pole. |
| 20 | S&F in repair electronic fan regulator, AC 230 V, switch type all as specified and directed . |
| 21 | S&F in repair fan regulator AC 230 V electronic socket type |
| 22 | S&F in repair ceiling rose ,ISI Marked all as specified and directed . |
| 23 | Attending Electric Complaints any type( No light ,U/S Ceiling fan,U/S LED Light etc ) and any capacity for continuous running, all as specified and directed by Engineer in charge. Note :(i) All Complaints ,any type shall be attended by Electrician with in 24 Hrs .Electrician would report every day from 09 :00 AM to 5 PM in Complaint cell for attending electrical complaints . (ii) Any items consumed in the Light Complaints, shall be measured seprately with fixing charges . No attending charges shall be paid extra for Complaints for that complaint. (iii) Electric complaints attending charges will not paid when Any other item mentioned in BOQ (New LED fitting,Cable,Submain wiring etc) has been consumed already. (iv)If Contractor fails to rectify complaint with in 24 hrs ,Then 100 Rs per Complaints per 24 hrs shall be recovered in the RAR. (v) Ladder for fixing and repair work of LED light and ceiling fan provide by the contractor free of cost . |
| 24 | S&F LED lights fitting 1x 20 W LED tube rod of lumens 110 /Watt ,4 feet,220V, 6500 K,AC decorative box type with driver, holder including Retrofit LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 25 | S&F LED light fitting integrated type with high out put diffuser 2 feet, 10 watt of lumens 100 /Watts,220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete. |
| 26 | S&F LED light fitting integrated type with high out put diffuser 4 feet, 20 watt of lumens 100 /Watts,6500K,220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete. |
| 27 | S&F Retrofit LED Tube 1x 20 W of lumens 100 /Watt ,4 feet,220V, 6500 K,Both side Connection all as specified and directed . |
| 28 | S&F LED luminaire 600 mm x 600 mm,20/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per directed by Engineer in charge . |
| 29 | S&F round shape 6 watt 220 volts AC recessed type,100 to 150 mm outer dimensions with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two core flexible copper conductor cable of suitable size complete all as per directed by Engineer in charge . |
| 30 | S&F round shape 12 watt 220 volts AC recessed type,150 to 200 mm outer dimensions with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two core flexible copper conductor cable of suitable size complete all as per directed by Engineer in charge . |
| 31 | S&F 6-10 watt 220 volts AC bed side/Reading lamp 360 degree rotatable LED lamp suitable for fixing on wall or table all as specified and directed per directed by Engineer in charge . |
| 32 | Supply and fix Exhaust fan louvers at any height suitable for 300 mm sweep all as specified and directed |
| 33 | S&F LED Bulb ,B22 Type ,10 W of Minimum lumens 105 /watt,6500 K Temperature ,3 star rated all as specified and directed . |
| 34 | S&F LED Bulb ,B22 Type ,12 W of Minimum lumens 105 /watt,6500 K,3 star rated all as specified and directed . |
| 35 | S&F LED Bulb ,E27 Type , 10 W warm light ,2700 K temperature all as specified and directed . |
| 36 | S & F MCB SP 6 to 32 Amps10 KA 240V 50HZ, ISI Marked . |
| 37 | All as per item No. 36 above but MCB SPN 6 to 32 Amps |
| 38 | S & F MCB TPN 32 Amps 10 KA 415V |
| 39 | S & F MCB TPN 40 to 63 Amps 10 KA 415V |
| 40 | S&F RCCB, DP, 25 Amps AC type in accordance with IS:12640-1 and IEC-6100-1, suitable for 240 Volts, 50 Hz with 10 KA short circuit withstand capacity. |
| 41 | Taking down Fans of any sweep dismantling into parts servicing, greasing/oiling parts including replacing cotter pin rubber ring shackle, check nut, bush/bearing of suitable sizes including re-assembling, fixing in position and testing complete. |
| 42 | Taking down existing Ceiling fan 1200 mm sweep from its location and Rewinding of ceiling fan/motor with super enameled copper winding wire of similar gauge and weight of the original winding insulating with class B, varnishing, drying,capacitor include etc complete, including refixing the same after carrying out the repair all as specified and directed . |
| 43 | All as per item No. 41 above but for exhaust fan of any sweep between 250 mm to 450 mm. Note:- Ladder charge is included for taking down and refixing the Exhaust Fan. |
| 44 | S&F GM Bush for ceiling fan 1200/1400 mm sweep/ Exhaust Fan 230/300/350/450 mm sweep/or any type fan complete all as directed. |
| 45 | S&F shackle for ceiling fan 1200/1400 mm sweep complete all as directed. |
| 46 | S&F Ball bearing for ceiling Fan/Exhaust Fan / or any type fan complete all as directed. Please Enable Macros to View BoQ information |
| 47 | S&F Ball bearing for ceiling Fan/Exhaust Fan / or any type fan complete all as directed. Please Enable Macros to View BoQ information |