| 1 | Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed. |
| 3 | M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 4 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 5 | M&L for plain cement concrete 1:3:6, type C1 (using 20mm graded crushed stone aggregate) upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed, complete all as specified and as directed. |
| 6 | M&L for RCC type 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed.(Note : Reinforement shall be measured and paid separately under relevant of this schedule) |
| 7 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, ressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed. |
| 8 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc, complete all as specified and as directed. |
| 9 | M&L TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc, complete all as specified and as directed. |
| 10 | M&L 40mm thick damp proof course to horizontal surfaces in cement concrete (1:2:4 )type-B0 (using 12.50 mm graded crushed stone aggregates) mixed with liquid water proofing compound with weight of cement as per manufacturer's instructions including necessary formwork, complete all as specified and as directed. Note:- WPC shall be measured and paid seperately. |
| 11 | M&L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean drysand @ 0.05 cu. m. per sq. m, complete all as specified and as directed. |
| 12 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 13 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 14 | Supply only integral water proofing compound complete all as specified and as directed. |
| 15 | M & L Sand filling under floors , including watering and consolidation, complete all as specified and as directed.Note:Compacted thickness shall only be measured and paid |
| 16 | M&L for 100mm thick cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) as in sub base of flooring, complete all as specified and as directed. |
| 17 | M&L for 40mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in base of floor, complete all as specified and as directed. |
| 18 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including screed bed of 15 mm thick in cement mortar (1:4) complete all as specified and as directed. |
| 19 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 20 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 21 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 22 | M&L for hardcore with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 23 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 24 | M & L for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St.-240 complete all as specified and as directed. |
| 25 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed. |
| 26 | M &L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valley complete all as specified and as directed. |
| 27 | M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 28 | M&L for pre polished chequered cement concrete tiles in floor, of size 20cmx20cmx 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including 75 mm thick PCC sub base in (1:3:6) type C2 (using 40mm graded stone aggregate) and screed bed of 15 mm thick in cement mortar (1:4) complete all as specified and as directed. |
| 29 | Returning, filling, in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed. |
| 30 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 31 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FR-LSH cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 32 | All as per item serial No 31 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board. |
| 33 | All as per item serial No 31 here-in-before but for 3pin, 5Amp socket on same board. |
| 34 | S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 35 | S & F switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed. |
| 36 | S & F switch socket outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed. |
| 37 | S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed. |
| 38 | S & F lamp holder, insulated, PVC / polycarbonate /bakelite body cord grip cap suitable for pendent fitting complete all as specified and as directed. |
| 39 | S & F Lumino LED lamps 10W E27W ball lamp lumen output 1020lm 3000K colour temp current 0.55 amps complete all as specified and as directed. |
| 40 | S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed. |
| 41 | S & F single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed. |
| 42 | S&F MCBs, SPN 20 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 43 | S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 44 | S&F 1100 volts grade heavy duty flat cable of size 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire complete all as specified and as directed. Please Enable Macros to View BoQ information |