| 1 | Demolition of cement concrete( unreinforced) in ground floors n. exc 15 cm thick below or above ground level complete all as specified and directed. |
| 2 | Demolition of precast cement concrete block built in cement mortar or cement lime mortar complete all as specified and directed. |
| 3 | Dismantling of timber scantling 40sqcm and over in section in any position (framed) complete all as specified and directed. |
| 4 | Dismantling of timber fillets, nails post rafters purlins etc. under 40 sqcm in section in framed work complete all as specified and directed. |
| 5 | Dismantling of posts or struts ( wood, steel, RCC) embeded in concrete any section including taking out of embeded portion and making good disturbed ground complete all as specified and directed. |
| 6 | Dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 7 | Demoltion of read lathing single, double, inluding bottom and plaster or checken wire lathing complete all as specified and directed. |
| 8 | Taking down shutters of any description exc 1sqm and n. exc. 2 sqm each complete all as specified and directed. |
| 9 | Taking down shutters of any description n. exc 1 sqm each complete all as specified and directed. |
| 10 | Taking down chowkhats with shutters (without taking of shutter for frames) n exc 1.5sqm complete all as specified and directed. |
| 11 | Taking down chowkhats with shutters (without taking of shutter for frames) exc 1.5sqm n exc 4.0sqm complete all as specified and directed. |
| 12 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 13 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 14 | -ditto- above for each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and directed. |
| 15 | Removal excavated material n exc 50m and depositng where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 16 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed. |
| 17 | Material and labour for PCC(1:4:8) type C-2 using 40 mm graded stone aggregate as in foundations, fiiling and mass concrete etc all as directed. |
| 18 | M&L for RCC M-25 design mix (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 19 | M&L for RCC M-25 design mix (20mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 20 | M&L for RCC M-25 design mix (20mm graded aggregate) as in beam, cantilivers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 21 | M&L for RCC M-25 design mix (20mm graded aggregate) as in Slab,Chajja and similar works supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 22 | M&L for TMT bar 10 mm dia and over cut to length, bent to shape reqd, incl cranking, bending, spirally for hooping, hooking ends and binding with 0.90 mm dia MS wire (annealed) complete all as specified and directed. |
| 23 | M&L for TMT bar 8mm dia and over cut to length, bent to shape reqd, incl cranking, bending, spirally for hooping, hooking ends and binding with 0.90 mm dia MS wire (annealed) complete all as specified and directed. |
| 24 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 25 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions squre, rectangular or polygonal, complete all as specified and directed. |
| 26 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and directed. |
| 27 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings,chajja and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 28 | M&L Precast cement concrete blockmasonry with solid block masonry (1:3:6) type D2 (Using 20mm graded aggregate) exc 10cm in width or girth and setting CM (1:6) complete all as specified and directed. |
| 29 | Material and labour to rendering 15mm thick in cement mortar (1:4) finishing even and smooth without using extra cement, on wall surface with integral water proofing compound, complete all as specified and as directed. Note:-WPC to be measured and paid seperately complete all as specified and directed. |
| 30 | M&L for 10 mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed. |
| 31 | M&L for 05 mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces in ceiling including finishing even & smooth without using extra cement complete all as specified and directed. |
| 32 | Supply only for water proofing compound complete all as specified and directed. |
| 33 | M&L preparation of new plaster surfaces and applying two coat of distemper oil emulsion on walls over a primer including plaster of minimum 1.50 mm thick wall care putty on wall over plastered surface to prepare the surface even and smooth.all as specified and directed. |
| 34 | M&L preparation of new plaster surfaces and applying two coat of distemper on ceiling over a primer including plaster of minimum 1.50 mm thick wall care putty on wall over plastered surface to prepare the surface even and smooth.all as specified and directed. |
| 35 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint and plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 36 | M&L hardcore of gauge n exc 63mm diposited, spread and levelled in lagers n exc 15cm thick, watered and rammed to a true surface with broken stone complete all as specified and directed. |
| 37 | M&L moorum filling in floors laid in lagers n.exc 15cm thick spread levelled and rammed including Watering complete all as specified and directed. |
| 38 | M&L 75 mm thick PCC 1:3:6 type C-2 (40mm graded agg) as in sub flooring complete all as specified and directed. |
| 39 | M&L 40 mm thick PCC 1:2:4 type B-1 (20mm graded aggregate) as in flooring cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 40 | M&L for glazed ceramic coloured tiles 450 x 300 x 7mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including 10mm thick rendring in CM (1:4) on fair faces of brick or concrete surfaces finished fair and even on vertical surfaces of wall including dismanthing floor/hearth or wall tilling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off premises complete all as specified and directed. |
| 41 | M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. |
| 42 | M&L for 75 mm thick cement concrete as in plinth protection typeC-2, 1:3:6 (using 40mm graded aggregate) finishing concrete surface even and smooth with without using extra cement complete all as specified and directed. |
| 43 | M&L for PCC(1:3:6), type C-2, using 40 mm graded aggregate in surface channel and drain including nasessary form work complete all as specified and directed. |
| 44 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, mould, mitred stop ends etc all as directed. |
| 45 | Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified. |
| 46 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 47 | Supply and Fix Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 48 | Supply and Fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 49 | S&F for 3 mm thick sheet glass aobscured or on one side good quality excedding 0.5 sqm in each pane complete all as directed. |
| 50 | M& L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 51 | M& L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 10 mm thick baking course in CM 1:4 complete all as specified and as directed. |
| 52 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, MS T iron door frame and similar work conforming to Fe.290.Gde-E-165 with complete fitting including necessary accessiores allas complete all as specified and directed. |
| 53 | M&L for preparation of new steel surface and applying of two coat of synthetic enamel paint over a one coat of red oxide exc 10cm width or girth complete all as specified and directed. |
| 54 | Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed. |
| 55 | M&L for water proofing treatment to RCC roof slab/sunken floor, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm(ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm complete all as specified and directed. |
| 56 | S&F rotational moulded polythene water storage tanks of capacity 1000 litres (cylindrical vertical with closed top) ISI marked hosted and fixed in position MES Schedule 2009, Part – I, complete all as specified and directed. |
| 57 | S&F 20 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors etc complete all as speicified and directed. |
| 58 | S&F 15 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors etc complete all as speicified and directed. |
| 59 | S&F 20mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 60 | S&F in repairs to 600 mm long PVC flexible Waste pipe to WHB/urinals/Sink complete all as specified and as directed. |
| 61 | S&F for 20 mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 m m - 210 gms ) complete all as specified and directed. |
| 62 | M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete. |
| 63 | S&F as in repairs.Vitreous China wash down water down water closet pan (P-Trap pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 64 | S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. with grating and union for discharge pipe complete all as specified and directed. |
| 65 | S&F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and directed. |
| 66 | S&F Vitreous china wash hand basin, white, flat back of size 550 mm x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32 mm dia, PVC flexible waste pipe of adequate length and dia and PVC connection 15mm size 450 mm length with PTMT nuts, complete all as specified and as directed. |
| 67 | Supply and fixing 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 68 | S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. . |
| 69 | Supply and fix 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 70 | S&F for Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed. |
| 71 | S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specified and as directed. |
| 72 | S&F PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 73 | S&F PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and directed. |
| 74 | S&F PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 75 | S&F MS flat iron such as small articles for hold fast and similar work complete all as specified and directed. |
| 76 | M&L PCC (1:2:4) type B1 (20mm graded Aggregate) for fixing hold fast complete all as specified and directed. |
| 77 | Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 78 | S&F 100mm long butt hinges of Stainless steel complete all as specified and directed. |
| 79 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section. |
| 80 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 81 | S&F 125mm size aluminium anodised cast type,complete all as specified and directed. |
| 82 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 83 | Taking down copper/aluminium point wiring(light) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit complete all as specified and directed. |
| 84 | Taking down copper/aluminium point wiring(5 A same board) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit complete all as specified and directed. |
| 85 | Taking down copper/aluminium point wiring(5/15 A Independent board) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit complete all as specified and directed. |
| 86 | Taking down copper/aluminium submain wiring (any size) complete, includingcasing caping /concealed conduit removing materials to store for keeping in safe custody or for taking credit complete all as specified and directed. |
| 87 | Taking down MCB DB TPN/SPN 8/4 way including depositing the same to MES Store complete all as specified and directed. |
| 88 | Taking down MCB (SP/SPN of any capacity) including depositing the same to MES Store complete all as specified and directed. |
| 89 | Taking down old service connection wire from pole to DB including removing GI bracket and depositing same to MES Store complete all as specified and directed. |
| 90 | Demolition of GI wire earthing including removing GI wire from each pit to DB complete all as specified and directed. |
| 91 | Material and labour for concealed Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm dia PVC conduit concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including accessories including cutting chases and making good the disturbed surfaces as per existing for one light point controlled by one switch complete all as specified and directed. |
| 92 | All as per item No.92 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed. |
| 93 | All as per item No.92 above but 5 Amp socket on same board with other switches complete all as specified and directed. |
| 94 | Material and labour concealed point wiring for power point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm width or higher size PVC conduit and fittings of medium grade fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. |
| 95 | Supply and fixing submain wiring for DBs/ Power Point, two single core ,4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. |
| 96 | Supply & fix ceiling rose surface bakelite 65 mm x 50 mm three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed. |
| 97 | Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. |
| 98 | Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed. |
| 99 | Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. (For Same Board only) |
| 100 | Supply and fix switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified and directed. |
| 101 | Supply and fix in repair Bldg security light fittings 35 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 102 | Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded aluminium housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6000K including necessary connection complete all as specified and directed. |
| 103 | Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. |
| 104 | Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. |
| 105 | Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessary connection complete all as specified and directed. |
| 106 | Supply and fix MCB SPN 40 - 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed. |
| 107 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and as directed. |
| 108 | Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion complete all as specified and directed. |
| 109 | Cutting/Tapping of existing cast iron/DI pipes 100mm dia in any position for insertion and fitting of new Tee, Coller, Tail pieces etc for taking out connections, branch connections complete all as specified and directed |
| 110 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep soft/loose type of soil getting out and levelling of bottom surface to required level for pipe laying complete all as specified and directed. |
| 111 | Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm dia complete all as specified and as directed. |
| 112 | Supply and fix gate valves 25mm dia bore, cast copper alloy,screwed down, wheel handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 113 | Supply and fixing in existing panel with necessary modification 4 Pole MCCB 63Amp 50 Hz, 415 V with rupturing capacity 16 KA with spider link and accessories complete all as specified and directed. |
| 114 | Supply and fixing in existing panel with necessary modification 4 Pole MCCB 63-100 Amp 50 Hz, 415 V with rupturing capacity 16 KA with spider link and accessories complete all as specified and directed. |
| 115 | Supply and lay in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 6 sq mm 2 core including making necessery connections complete all as specified and directed. |
| 116 | Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level complete all as specified and directed. |
| 117 | Supply and laying burnt clay sub class B brick as cable protection complete all as specified and directed. |
| 118 | Supply and fix GI pipe 40mm light grade for cable protection complete all as specified and as directed. Please Enable Macros to View BoQ information |