| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or stone walls or ceiling etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 2 | M&L for rendering 15 mm thick on fair faces of brick work in CM in 1:4 finished even and fair and mixing with water proofing liquid as per manufacturer instruction (but excluding the cost of water proofing liquid) external surface, complete all as specified and directed. |
| 3 | Supply only Integral crystalline water proofing compound of approved make, complete all as specified and directed. |
| 4 | M&L for rendering 5 mm thick in CM 1:3 on concrete surface in ceiling complete all as specified and directed. |
| 5 | M&L for rendering 10 mm thick in CM (1:6) on Brick/ Conc surface finished even and fair on internal surfaces of wall, complete all as specified and directed. |
| 6 | M&L for complete removal of existing treatment on exterior and interior surface of wall and ceiling/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour, complete all as specified and directed. |
| 7 | M&L for prepration of new / Old plastered surface of wall and applying two coats of water based premium acrylic smooth exterior emulsion of approved coulur with silicon addictive & color stay technology excellent dirt pick up resistance with low VOC less than 50 gram/ltr as per the LEEDS specification anti algal propertiess in two coats @ 1.79 ltrs (undiluted)/10sq mtrs diluted with water as per manufacturer instruction, complete all as specified and directed.Name of Manufacturer : ASIAN/ BERGER/ NEROLAC or equivalent make as mentioned in Appx 'D'Note- The contractor shall obtain approval of the agency from GE and shall enter a memorandum of understanding (MOU) with the manufacturer duly approved by GE. The execution of work shall be commenced after the submission of MOU and necessary approval from the Engineer-in-charge. MOU shall be valid during currency of work. However during defectlibality period, if any defect is noticed, the contractor shall only be responsible for the rectification of same. |
| 8 | Material and labour for 1mm thick wall care putty with one coat of acrylic water based exterior grade primer @0.9 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio on exterior & interior wall. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed.Name of Manufacturer : ASIAN/ BERGER/ NEROLAC or equivalent make as mentioned in Appx 'D' |
| 9 | Material and labour for 1mm thick Plaster of Paris Putty over plastered surface even and smooth complete all as specified and directed. |
| 10 | M&L for preparation of new or old plastered surface and applying two coats of Premium Plastic Emulsion paint on walls and ceiling, complete all as specified and directed. |
| 11 | Chipping of unsound/weak concrete material of 50 mm average thickness from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.Note :Where the items executed upto 12 mtr height, necessary scaffolding, props, jacks, shuttering and ladder shall be provided by the contractor in his own arrangement and the same is included in unit rates quoted. |
| 12 | Cleaning of reinforcement from rust from the reinforcing bars upto 12mm dia to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Note :Where the items executed upto 12 mtr height, necessary scaffolding, props, jacks, shuttering and ladder shall be provided by the contractor in his own arrangement and the same is included in unit rates quoted. |
| 13 | Providing, mixing and applying SBR polymer modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) 50mm thickness in 03 layers as per specifications and directions of Engineer-in-charge. Note :Where the items executed upto 12 mtr height, necessary scaffolding, props, jacks, shuttering and ladder shall be provided by the contractor in his own arrangement and the same is included in unit rates quoted. |
| 14 | Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame). (Ventilator and Window) complete all as specified and directed. |
| 15 | Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (Without taking off shutters from the frame). (Doors and Window) complete all as specified and directed. |
| 16 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.NOTE :(i) The WPC shall comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms). (ii) The frame shall fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws.(iii) The WPC shall have minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant.(iv) The cost of M.S. hold fast/ lugs or SS dash fasteners shall deemed included in quoted unit rate. Each frame shall be fixed with min 06x holdfasts/ faster's. |
| 17 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of requiredsize with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 18 | S&F factory made uPVC white colour casement door with 3D hinges made of (Bigseries) frame 67 x 64mm & sash 67 x 110mm both having wall thickness of 2.3+-0.2mm and size glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi chambered frame, sash and mullion (wherever required) extruded profile duly reinforced with 1.60+-0.2mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gaslet, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear,cylinder with keeps and one side key, GI fastener 100x8mm size for fixing frame to finished wall and necessary steel screws etc.. Profile of frame and sash shall be mitredcut and fusion welded at all corners,mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware and drainage of water etc. After fixing from the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of appropriate quality,complete all as specifed and direced by engineer-in-charge.Note- Glass shall be paid separately |
| 19 | Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose. |
| 20 | Providing and fixing factory-made uPVC white colour casement (openable) window suitable for openings up to 1.00 sqm, made from extruded uPVC profiles of wall thickness 2.3 mm (±0.2 mm). The window shall consist of multi-chambered hollow profiles as follows: frame section 60 mm × 58 mm, sash section 60 mm × 73 mm, T-profile section 60 mm × 74 mm (used between two shutters), and glazing bead 35 mm × 20 mm. All members shall be mitre cut and fusion welded at corners. Work includes drilling for hardware, provision for drainage, and fixing of all accessories. EPDM gasket of 1.2 mm (±0.2 mm) thickness shall be provided. Galvanised steel reinforcement shall be inserted as follows: frame 28 mm × 21.5 mm, sash 31 mm × 27.5 mm, and T-profile 27 mm × 17 mm. Frame shall be fixed to wall using 8 mm × 100 mm long anchor fasteners.Hardware shall include casement handles (zinc alloy, white powder-coated), butt hinges (zinc alloy, white powder-coated), and multipoint locking system with transmission gear of mild steel. Window shall accommodate 5 mm thick glass of approved make. |
| 21 | Providing and fixing factory made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm(+0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes costof glass and includes all other connected accessories Net opening will be measured for payment purpose.) |
| 22 | S & F Stainless steel wire mesh, 0.56mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks, or SS wire staples complete all as specified and directed. |
| 23 | Supply & Fix 5.5 mm thick plain sheet glass as in,shutters with and including rubber gasket and natural colour anodized 15 micron snap on aluminium beading/glazing, clips etc complete all as specified and directed. |
| 24 | Supply & Fix 5.5 mm thick Frosted sheet glass as in,shutters with and including rubber gasket and natural colour anodized 15 micron snap on aluminium beading/glazing, clips etc complete all as specified and directed. |
| 25 | Providing and applying approved quality weatherproof silicone sealant around the perimeter of UPVC window frames (internal and external sides) to seal the gap between frame and masonry/plaster surface, including surface preparation, masking, and cleaning, complete in all respects as directed by Engineer-in-Charge. |
| 26 | S & F 150mm SS handles, complete all as specified and directed. |
| 27 | S & F 200mm SS barrel tower bolts fixed complete all as specified and directed. |
| 28 | S & F 300 mm SS sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet fixed complete all as specified and directed. |
| 29 | S & F 100 mm long SS butt hinges, complete all as specified and directed |
| 30 | Dismantling boarding any desccription fixed in any position with nails or any other means complete all as specified and directed |
| 31 | Providing and fixing 18mm thick factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powcler/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being Termite/borer proof, water/moisture proof and Fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel hinges shall be paid separately) |
| 32 | Providing and fixing 12 mm thick factory made single extruded WPC (Wood Polymer composite) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In-Charge. |
| 33 | S & F continuous (piano) hinges, Stainless steel of width 30 mm complete all as specified and directed. |
| 34 | S & F 150 mm Hasp and staple, Stainless steel, including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 35 | S & F magnetic catches for cabinets of size 50 mm complete with striking plate & magnetic stud complete all as per approved samaple by Engr-IN-Charge complete all as specified and directed. |
| 36 | S & F Stainless Steel 150 mm dia oval shape handle fancy type brass polished bright finish complete all as specified and directed |
| 37 | M & L 40 mm brass dia cuboard knobs fixed with nuts ,screws and washers of mild steel, bright finished complete all as specified and directed. |
| 38 | Dismantling wrought Iron or mild steel work of any description not other wise described complete all as specified and directed. |
| 39 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E 165 including two coat of synthetic enamel paint with zinc primer, complete all as specifiedand directed. |
| 40 | S&F in repair fancy type drapery rod 20 mm dia stainless steel incl end brackets, and side brackets, complete all as specified and directed. |
| 41 | Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds etc complete all as specified and as directed.Note : - All demolished items/ debris to be removed out side of MoD land. |
| 42 | Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay PCC padding complete all as specified and directed. Note : - All demolished items/ debris to be removed out side of MoD land. |
| 43 | M&L for cutting out cracks to v section in existing roofs or terrace, cleaning of grouting with cement and sand slurry 1:3, complete all as specified and directed. |
| 44 | M&L for providing PCC type C-1, 1:3:6 (using 20mm graded aggregate) for providing cement concrete as levelling and roof kerbs or mud stops, including finishing the surface with grinder to receieve the acrylic based water proofing material, rounded or chamfered on edges etc complete all as specified and directed. |
| 45 | M&L for Rendering or bedding layer 15mm thick in cement mortar 1:3 cover concrete surface of roof, mixed with WPC 2% wt of cement including finishing surface even and smooth without using extra cement complete all as specified and directed(Note:- WPC shall be measured and paid separately) |
| 46 | Preparation of newly plastered surfaces of roof including cleaning the surfaces by using wire brush/ pressure hose and applying high performance polyurethene liquid membrane waterproofing coating in two coats @ 1.5 Kg/Sqm/ 2 coats with spray/ brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3 N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging ability of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet, complete as per manufacturer's instructions complete all as specified and directed.Note:-(i) The contractor shall submit a guarantee of 10 years the date of completion of work for waterproofing treatment alongwith manufacturer's guarantee. The amount of Rs. 40 (Rupees Forty) per Sqm and min of Rs. 4000/- for waterproofing treatment shall be withheld from contractor's in the final bill till the expiry of guarantee period. The contractor at his own option may furnish fixed deposit receipt pledged in favour of GE against guarantee money. |
| 47 | Contd/...(ii) The water proofing shall be carried out by authorized applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work. (iii) Materials shall be procured from manufacturer/authorized dealer only and original purchase voucher for the full quantity of material shall be procured by the contractor.(iv) The contractor shall enter ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. |
| 48 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 49 | M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed 1:6 complete all as specified and directed. |
| 50 | M & L glazed ceramic coloured tiles of approved quality ISI marked (450 x 300 x 7 mm thick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface complete all as specified and directed. |
| 51 | M&L for treatment to sunken floor and sides, complete as specified hereafter:-Cleaning & Surface Preparation – Demolition and removal of existing PCC, lime concrete, muddy soil, and any previous treatment from sides and base slab, including sand blasting with compressed air for thorough cleaning. All debris to be removed and disposed of outside Defence land at contractor’s own expense.Waterproof Coating – Applying a base coat of glass fibre reinforced acrylic modified cementitious coating system (Sika Top Seal-107 @ 1.50 Kg/Sqm with glass fibre reinforcement Sika Fab-I) followed by a top coat of Sika Seal-107 @ 1.50 Kg/Sqm, or equivalent make (Forsoc / Pidilite). Plastering – Providing and laying 15 mm thick cement plaster in CM 1:3 over sides and base slab of sunken portion, mixed with integral waterproofing compound (Sika Plastocrete Plus or equivalent) as per manufacturer’s instructions.Bituminous Coating – Applying tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm evenly on plastered surfaces of sides and base.Spout Pipe – Supplying and fixing 25 mm bore CPVC pipe spout from inside of sunken portion extended minimum 150 mm beyond external face of wall, complete. Note:- Floor area to be measured and paid only. |
| 52 | M&L for Cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in sunken part of slab complete all as specified and directed. |
| 53 | M&L for 25mm thick PCC type B-1, 1:2:4 (using 12.5mm aggregate) as on floor above sunken treatment for flooring, complete all as specified and directed. |
| 54 | S & F in repair 75 mm dia UPVC (SWR) pipes TYPE -'B' Conforming to IS 13592 single socketed, in any length with rubber ring joints, laid in trenches or in floors including all type earth work complete all as specified. |
| 55 | S & F in repair 75 mm dia UPVC (SWR) pipes TYPE -'B' Conforming to IS 13592 single socketed in any length with rubber ring joints fixed to walls complete all as specified. |
| 56 | S & F in repair UPVC (SWR) 110 mm dia pipes TYPE -'B' Conforming to IS 13592 single socketed, in any length with rubber ring joints, laid in trenches or in floors including all type earth work complete all as specified. |
| 57 | S & F in repair UPVC (SWR) 110 mm dia pipes TYPE -'B' Conforming to IS 13592 single socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed. |
| 58 | S&F in repair 110 mm dia UPVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 59 | S & F in repair 75 mm dia UPVC (SWR) bends any radius complete all as specified and directed. |
| 60 | S&F in repair 110 mm dia UPVC (SWR) branch piece, (double Y) equal or unequal complete all as specified and directed. |
| 61 | S&F in repair 75 mm dia UPVC (SWR) branch piece, (double Y) equal or unequal complete all as specified and directed. |
| 62 | S & F in repair 75 mm dia UPVC (SWR) bends with access door any radius complete all as specified and directed. |
| 63 | S & F in repair 110 mm dia UPVC (SWR) plain bends any radius complete all as specified and directed. |
| 64 | S & F in repair 75 mm dia UPVC floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 65 | M&L for Mild steel FE-250 Gde E-165 work in brackets, clamps, flat iron supports, holdfasts etc., fabricated from MS flat/round/angle sections, including cutting, bending, drilling, welding, and fixing in position to hold rainwater pipes against wall, with necessary bolts, nuts, washers, and painting two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 66 | S&F in repair 110mm UPVC junction single, (single T) equal or unequal with access door, complete all as specified and directed |
| 67 | S&F in repair 75mm UPVC junction single, (single T) equal or unequal with access door, complete all as specified and directed |
| 68 | S&F in repair 150mm x 100mm Salt-glazed stoneware gullytraps, square or round mouthed, type 'P' and setting and jointing in cement mortar 1:1, complete all as specified and directed. |
| 69 | M&L for cutting chases pinning in , making good to facing where reqd. and pointing in CM 1:3 to ends or edges of landing , steps, cills, sunshades, selfs lintels etc. and cutting chases for conceled for water tubing or conceled condute wiring etc and making good, cutting not exceeding 10cm girth complete all as specified & as directed |
| 70 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store 20mm bore pipe complete all as specified and directed. |
| 71 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store 15mm bore pipe complete all as specified and directed. |
| 72 | S&F PP-R pipe 20 mm bore outer dia, PN 16, three-layer construction (Polypropylene Random Copolymer), conforming to IS:15801, UV-stabilized and anti-microbial, fusion welded type, having thermal stability suitable for hot and cold water supply systems, fixed to walls and ceilings or laid in floors including all PP-R plain and brass-threaded polypropylene random fittings, complete all as specified and directed.The pipe shall be fixed with suitable clamps at 1.00 metre spacing, and all joints shall be tested for leak-proofness to the satisfaction of the Engineer-in-Charge.The unit rate quoted shall be deemed to include all necessary fittings, cutting, jointing, fixing, alignment, supports, testing, and making good to the original finish, complete all as specified and directed. |
| 73 | S&F PP-R pipe 16 mm bore outer dia, PN 16, three-layer construction (Polypropylene Random Copolymer), conforming to IS:15801, UV-stabilized and anti-microbial, fusion welded type, having thermal stability suitable for hot and cold water supply systems, fixed to walls and ceilings or laid in floors including all PP-R plain and brass-threaded polypropylene random fittings, complete all as specified and directed.The pipe shall be fixed with suitable clamps at 1.00 metre spacing, and all joints shall be tested for leak-proofness to the satisfaction of the Engineer-in-Charge.The unit rate quoted shall be deemed to include all necessary fittings, cutting, jointing, fixing, alignment, supports, testing, and making good to the original finish, complete all as specified and directed. |
| 74 | S & F PP-R Gate valves (brass insert) as per requirement of the site outer dia 20 mm complete all as specified and directed. |
| 75 | S&F in repair 15 mm size bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete all as specified and directed.Make : Jaquar Cat Part No OPP-CHR-15037PM or Equivalent of Kohler |
| 76 | S&F in repair 15 mm size angular cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete all as specified and directed.Make : Jaquar Cat Part No OPP-SSF-15053PM or Equivalent of Kohler or Grohe |
| 77 | S&F wall mixer (3 in 1) with bend pipe for overhead shower, connecting legs and wall flange,complete all as specified and directed.Make: Jaquar model No.-FUS-CHR-29281 or equivalent in Kohler or Grohe |
| 78 | S & F in repairs Bib Tap, 2 way, with wall flange 15 mm dia complete all as specified and directed.Make :- Jaquar Cat Par No- OPP-CHR-15041PM/Grohe/Kohler. |
| 79 | S&F in repair single lever extended basin mixer for WHB cast copper alloy with capstin heads chromimium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed.Make : Jaquar Cat Part No FUS-CHR-29023B or Equivalent of Kohler or Grohe |
| 80 | S&F stainless steel chromium plated Bottle trap having size 32mm with 250mm & 190mm long wall connection pipes an wall flange,complete all as specified and directed.Make - Jaquar model No- ALD-SSF-769L250x190/Grohe/ Kohler |
| 81 | Supply and Fix in repairs Health faucet (Hand shower) with 1 metre flexible tube with wall hook, Chromium Plated as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No ALD-CHR-573 or Equivalent of Kohler Or Grohe |
| 82 | S&F in repair square shape single flow maze overhead shower of size 150mmx150mm (Body and face plate stainless steel) with rubit cleaning system, long shower arm and wall flange complete all as specified and directed.Make: Jaquar model no OHS-CHR-1605 or equivalent in/Grohe/Kohler |
| 83 | S&F in repair Frameless, Edged,moulded,itched decorative wall looking mirror of size 900 x 900 mm with complete lighting arrangement on back side of mirror, sensor sysem, selected quality 5 mm thick , and fixed to wall, complete all as specified and directed. |
| 84 | S&F in Single Towel Rail 600mm Long, Stainless Steel including brackets fixed to wall stainless steel screws, complete all as specified and directed. Make- Jaquar Model No ACN-CHR-1111SM or equivalent in Grohe or Kohler |
| 85 | S & F in repair SS soap dish complete all as specified and directed. Make- Jaquar ACN-SSF-1131N or Equivalent in Grohe or Kohler |
| 86 | S&F in repair vitreous china counter top wash hand basin, rectangular pattern, white, size of 530mm x 420mm, excluding taps, waste chain and plug, 32 mm waste coupling, and UPVC waste pipe of 40 mm dia laid up to 1000 mm, fixed in repair, complete all as specified and directed by Engineer-in-Charge.Make: Jaquar model No.- CNS-WHT-905 or equivalent in Grohe or Kohler |
| 87 | S&F PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and directed.Make : Prayag /Polytuf/Pearl |
| 88 | Supply and fix glass shelf matt finished chromium plated (MCH/Colour CP) 600 mm Glass Shelf - (Chrome, Wall Mounted) bracket and fittings, complete all as specified and directed.Make- Jaquar Continental ACN-CHR-1171N/ Grohe/Kohler |
| 89 | S&F in repair stainless steel chromium plated Tumbler Holder ,complete all as specified and directedMake- Jaquar Model No- CAN-CHR-1141N/ Grohe/ Kohler |
| 90 | S&F Soap Dispenser with glass Bottle, complete all as specified and directed.Make- Jaquar Model No- AKP-CHR-35735P or equivalent in Kohler or Grohe |
| 91 | S&F decorated type towel rod ring square shape with round flange, complete all as specified and directed.Make- Jaquar Cat Par no- CAN-CHR-1121BN or equivalent in /Grohe/Kohler |
| 92 | S & F in repairs vitreous China single piece EWC of approved make including flushing cistern, trap set in an incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed.Make- Jaquar Cat Par No- CNS-WHT-853S220SPPSMY or equivalent in Grohe or Kohler |
| 93 | Supply and fix 500 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete and including dismantling of old tank complete all as specified and directed. |
| 94 | Demolition of brick work built in CM complete all as specified and directed. |
| 95 | M&L for brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in CM 1: 6 complete all as specified amd directed. |
| 96 | M&L for brick work with sub class B bricks straight or curved on plan to any radius built in Half brick thick wall built in CM 1: 6 complete all as specified. |
| 97 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 98 | S&F 12 mm thick stepping stone/tiles as in landing of steps/approach/terrace size of tiles/stones shall be 1200x600mm for tread and 1200x300mm for riser from which suitable size of steps shall be cut and applied as per site requirement fixed with best adhesive as per manufacturer instruction,including dismantling of exsiting tiling/pcc floor/ wall any type and removing dubries outside of Md/OTM accn, complete all as specified and directed.Make- Jhonson endura or equivalent. |
| 99 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for,complete all as specified and directed.Note: All demolished items/debris to be removed out of MOD land |
| 100 | M&L for Precast Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in manhole covers etc. all as specified and directed by Engineer-in-Charge. |
| 101 | M&L for 18-19 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms (including a hole of gas pipe) and like incl 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 102 | M&L for mild steel TMT bars 10 mm dia and over in reinforcement cut to length bent to shape required incl cranking bending, spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 103 | S&F in repairs, sinks with drainage board made of stainless steel 1.0 mm thick SS 304 grade (kitchen or laboratory type), with plugs, washers and wastes; including bedding in cement mortar onto dwarf wall or fixing with cantilever brackets and connecting union to pipe. Also including provision and fixing of uPVC waste pipe of 40 mm nominal bore, length up to 1000 mm, with uPVC bottle trap, all jointed and connected in position, Overall Dimension 1016 x 508 x 204 mm, complete all as specified and directed.Make: New Coral of Parryware/ Platino of Hindware/ equivalent in Jaquar |
| 104 | Supply and Fix Stailness steel plate rack of size 910mm x 780mm x 250mm (31'' x 36 \\" x 10\\") with separators and 3 tier shelves, provisionsing of hook 9 Nos made out of stailness steel sheet of grade AI SI 304 and fixed in repairs all as specified and directed. |
| 105 | S & F corner glass shelf superior quality matt finished crromium plated (MCH/Colour CP ) with bracket and fittings complete all as specified and directed.Make- Jaquar Model No- CAN-CHR-1173 or equivalent in Grohe or Kohler |
| 106 | M&L for Coloured Porselano vitrified tiles 8-10 mm thick, area of each tile exceeding 0.36sqm but not exceeding 0.72 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bedding in cement mortar (1:4) complete all as specified and as directed.Make- Jhonson or equivalent |
| 107 | M&L for Coloured porselano vitrified tile 8-10 mm thick area of each tile exceeding 0.36 sqm but not exceeding 0.72 sqm, in vertical surface, skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed |
| 108 | Demolition of existing sewage line and Supply & laying, jointing and testing in trenches DWCPE SN 8) nominal size 175 (ID)/200(OD) dia as per IS-16098 (Part-2): 2013 upto a depth of 1.8 m with and including all items and activities like PCC Bed, Haunching & Benching against two pipes, required to make sewer line functional complete all as specified and as directed. |
| 109 | Cutting into existing manholes for connecting new drains of internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed. |
| 110 | Demolition of cement Concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) incl chequered tiling and Paver blocks complete all as specified and as directed. |
| 111 | M&L for 1st quality non skid coloured Heavy duty, Matt finish tiles of size 300mmx600mm, 12 mm thick set and jointed in neat cement slurry & pointed with coloured cement to match in floor over and including including 15 mm thick screed bed in cement mortar (1:4) AND 25 mm thick levelling corse of pcc 1:2:4 using 12.5 mm crushed stone aggregate complete all as specified and directed. Make Johnson Endura or Equivalent in Kajaria/Somany |
| 112 | M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 113 | M&L for 75mm thick PCC type D-2, 1:4:8 (using 40 mm graded aggregate) as in subbase of flooring and hardstanding, complete all as specified and directed. |
| 114 | M&L for PCC 1:2:4 type B-1 (20mm graded aggregate) as in kerb around chequered tiles and paver block slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 115 | Supplying and fixing polished black granite inauguration plate of size 600mm x 900mm x 18-20mm thick, with machine-cut edges, mirror finish, and engraving of text/logo as per approved design including gold paint filling in letters, fixing with stainless steel clamps and necessary adhesive, complete as directed by Engineer-in-Charge. |
| 116 | Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 117 | M&L for point wiring suitable for modular fittings one light/fan/bell point with PVC insulated FRLS-H unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit medium grade not less than 20 mm dia, ISI marked, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated FRLS-H unsheathed copper conductor (Green in color) as earth wire and connected to common earth dolly incl making good to surface with CM (1:4) plaster and paint to match the surface complete all as specified and directed .Note :- Steel terminal boxes, cover plate and other modular accessories shall be measured and paid seperately. |
| 118 | All as per item No 116 above but for one light point two way |
| 119 | All as per item No 116 above but for one bell point on independent board controlled by one 5 Amps bell switch. |
| 120 | All as per item No 116 above but for One 5 pin 5 amps socket outlet on same board with cables of size 2.5 sqmm |
| 121 | All as per item No 116 above but for One 5 pin 5 amps socket outlet on independent board with cables of size 2.5 sqmm |
| 122 | All as per item No 116 above but for One 6 pin 15/16 amps socket outlet on independent board with cables of size 2.5 sqmm |
| 123 | All as per item No 116 above but for on independent board with cables of size 4 sqmm (for Geyser and AC point) complete. |
| 124 | S&F modular switch piano flush button single pole one way 5 Amp complete all as specified and as directed. |
| 125 | S&F modular switch piano flush button single pole two way 5 Amp complete all as specified and as directed. |
| 126 | S&F modular bell push switch piano flush button single pole one way 5 Amp complete all as specified and directed |
| 127 | S&F modular socket outlet flush type 3/5 pin 5/6 Amps 230V AC complete all as specified and as directed. |
| 128 | S&F modular switch piano flush single pole one way 15/16 Amps complete all as specified and as directed. |
| 129 | S&F modular socket outlet flush type 5/6 pin 15 Amps 230V AC complete all as specified and as directed. |
| 130 | M&L for ceiling rose 3 terminal/PVC / polycarbonate, isolated body complete all as specified and as directed. |
| 131 | M&L modular ceiling fan step regulator 2 module complete all as specified and as directed. |
| 132 | S&F calling bell ding dong AC 230 volts single pole complete all as specified and directed. |
| 133 | S&F modular flush box 1/2 module complete all as specified and as directed. |
| 134 | S&F modular flush box 3 module complete all as specified and as directed. |
| 135 | S&F modular flush box 6 module complete all as specified and as directed. |
| 136 | S&F modular flush box 8 module complete all as specified and as directed. |
| 137 | S&F modular white cover plate 1 module complete all as specified and as directed. |
| 138 | S&F modular white cover plate 2 module complete all as specified and as directed. |
| 139 | S&F modular white cover plate 3 module complete all as specified and as directed. |
| 140 | S&F modular white cover plate 6 module complete all as specified and as directed. |
| 141 | S&F modular white cover plate 8 module complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 142 | S&F modular white cover plate 8 module complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail