| 1 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. |
| 2 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 3 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and as directed. Note: To be executed for provision of ridges and hips. |
| 4 | S & F 4mm thick Non asbestos fibre cement building boards of size 605x605mm with Anodised aluminium snap grid frame work for false ceiling, flat or sloping fixed or laid/ inserted to timber/GI/Aluminium framework with screws including dismantling of old ceiling of any description complete all as specified and as directed. |
| 5 | Dismantling timber scantling 40Sqcm and over in section as in framed work in any position complete all as specified and as directed. |
| 6 | Dismantling timber scantling unframed work under 40sqcm in section in fillets, rails, rafter, purlins etc fixed with nails/screw etc complete all as specified and as directed. |
| 7 | M & L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to grade Fe-410-W (Gde E 250) for fixing complete all as specified and as directed. |
| 8 | S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 9 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 10 | Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 11 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 12 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 13 | M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed. |
| 14 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 15 | M&L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 16 | M & L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 17 | M&L for RCC, 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in beams, seismic bands, cantilevers, bressumers and lintels over 1.5 m span complete all as specified and as directed. |
| 18 | Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 19 | M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 20 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 21 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 22 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 23 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 24 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 25 | M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 26 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 100Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 27 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 28 | M & L for preparation of newly plastered surfaces of walls and applying one coat of Chalk whiting over a coat of 2mm thick (average) wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distemper complete all specified and as directed. |
| 29 | M&L for preparation of old decorated surfaces of wall and applying one coat of oil bound distemper complete all as specified and as directed. |
| 30 | M&L for preparation of newly plastered surface of walls and applying two coats of acrylic emulsion weather coat paint over one coat of primer complete all as specified and as directed. |
| 31 | M&L for preparation of old decorated surfaces of walls and applying one coat of acrylic emulsion weather coat paint complete all as specified and as directed. |
| 32 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 33 | M&L for coloured non skid ceramic tiles 7 to 8mm thick (square / rectangular)area of each tiles exc 0.18 sqm but not exceeding 0.38 Sqm on vertical surfaces as skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 34 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. Note: Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces. |
| 35 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and as directed.Note : Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces |
| 36 | M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 37 | M&L for mild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 38 | S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 39 | S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed. |
| 40 | M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 41 | S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 42 | S & F 50 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 43 | S&F 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 44 | S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 45 | S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. |
| 46 | S & F 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and as directed. |
| 47 | S&F powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed |
| 48 | S & F Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and as directed. |
| 49 | S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 50 | S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 51 | S & F in repairs, 20mm dia anodised aluminium tubular curtain rod including brackets,stops, rollers complete all as specified and as directed. |
| 52 | M&L for pre painted, polished chequered cement concrete tiles in floor, area exc 0.06 Sqm but not exc 0.11 Sqm, 22mm to 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 15 mm thick cement mortar (1:6) complete all as specified and as directed. |
| 53 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 54 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. Please Enable Macros to View BoQ information |