| 1 | (A)FIRE FIGHTING SYSTEMS(a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required :(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm 56M Head |
| 2 | (a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)(b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads2280 lpm 56 m head |
| 3 | (a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, single stage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm 35m head |
| 4 | (a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads180 lpm 56m head |
| 5 | Supplying, installation, testing & commissioning Horizontal centrifugal pump set of make Kirloskar/Crompton with C.I casing, CI impeller, SS shaft with Suitable HP, 3 Phase 2900 RPM electric motor suitable for operation on 400/440 volts, 3 phase 50 Hz AC, l00mm dia pressure gauge, G.M. isolation cock complete as required. Cost shall include electrical control panel, starters, CTs, Ammeter, Voltmeter, suitable rating TP & N SDFU, phase indicating lamps, Al. bus bars of suitable ratings with wiring & all accessories etc.a) Domestic Water Pumps with motor.b) Capacity 6 LPS each.c) Head 30 Mtr.d) RPM 2900 |
| 6 | Supplying, installation, testing and commissioning mono block type self priming drainage pump of 300 LPM discharge of water at 10 m head complete with base plate and all accessories suitable for operation on 230V single phase 50Hz. A.C. supply complete with starter for automatic operation i/c water level sensing device, inter connection with submersible cable etc. as reqd. |
| 7 | Fabrication, supplying, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof,powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required. INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Diesel Engine ControlControl for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter, All standard relays and accessories for automatic operation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 8 | Fabrication, Supplying, Installation, Testing & Commissioning of Electrical Motor Control Panel for 7.5 HP Terrace Pump of cubical construction floor/wall mounted, fabricated out of 1.6mm thick CRCA sheet, compartmentalised with hinged lockable doors,dust & virmin proof, powder coated of approved shade, interconnetion with solid aluminium strip/single core PVC insulated FR copper conductor cable, having suitable mountings for switchgear & accessories & internal control & power wiring with suitable rating as required and earth terminals, numbering etc.complete in all respects, suitable for operation on 415 V, 3 Phase 50 HZ AC supply with encloser protection consisting of following material in the panel:- (i) One no 100 A TP incoming MCCB. (ii) 0-500 volts 96 x96 square mm voltmeter with slector switch and control fuses- 1 SET.(iii) 0-200 amps 96 x96 square mm ammeter with CT's and slector switch- 1 SET.(iv) Phase indicating lamp with toggle switches. (v) Indication lamps for ON/OFF/TRIP status Outgoing Feeders / Starters. (vi) 32 A MCB - 1 Set (vii) Star Delta starter suitable for 7.5 HP motor for Downcomer Pump - 1 Set.(vii) Auto manual selector switch (viii) Single phase preventor (x) Overload relay Provision in control panel to connect pressure switch for autmatic operation of roof fire pump. |
| 9 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:Butterfly valve 150 mm |
| 10 | Butterfly valve 100 mm |
| 11 | Butterfly valve 80 mm |
| 12 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required:Non return Valve 150 mm |
| 13 | Non return Valve 100 mm |
| 14 | Non return Valve 80 mm |
| 15 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.Y Strainer 150 mm |
| 16 | Y Strainer 80 mm |
| 17 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. a)150 mm. Dia |
| 18 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) |
| 19 | 150 mm dia |
| 20 | 100 mm dia |
| 21 | 80 mm dia |
| 22 | 65 mm dia |
| 23 | 25 mm dia |
| 24 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia |
| 25 | 50 mm dia |
| 26 | Supply, Installation, Testing and Commissioning of pressure gauge suitable for working pressure of 250 PSI including all accessories complete as required.. |
| 27 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 28 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 29 | Supplying and fixing of CO2 (Carbon Dioxide) Fire extinguisher ISI marked confirming to SI: 15683. Capacity 4.5 kg complete with delivery hose, locking arrangement, operation manual, bracket with low screw and sleeve etc. as required. |
| 30 | Supplying and fixing of CO2 (Carbon Dioxide) Fire extinguisher ISI marked confirming to SI: 15683. Capacity 9 kg complete with delivery hose, locking arrangement, operation manual, bracket with low screw and sleeve etc. as required. |
| 31 | Supplying and fixing of stored pressure Fire Extinguisher of ABC Dry chemical powder type 6 kg capacity made of high pressure steel cylinder complete with squeeze grip type, internal discharge tube, 1 M long high pressure wire braided discharge hose, pressure gauge and fully charged with ABC powder confirming to IS:15683 Duly ISI marked |
| 32 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 Mtr |
| 33 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : a) Stainless Steel (Grade 304) |
| 34 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required |
| 35 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 36 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: a) Stainless Steel (Grade 304) |
| 37 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:a) 4 way - 150 mm dia M.S. Pipe |
| 38 | Supplying, Fixing, Testing and Commissioning of 100 mm dia draw out connection screw type with 100 mm dia C.I. Foot valve complete with nut-bolt, rubber gasket, complete, etc. as required. |
| 39 | Supplying of following sizes of PVC insulated and PVC sheathed/XLPE a1uminium conductor cable of 1.1KV grade as required.3.5C x 120 sq mm |
| 40 | 3.5C x 50 sq mm |
| 41 | 4C x 25 sq mm |
| 42 | 3C x 10 sq mm |
| 43 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 44 | Above 35 sq. mm and upto 95 sq. mm |
| 45 | Above 95 sq. mm and upto 185 sq. mm |
| 46 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) |
| 47 | 4 X 35 sq. mm (32mm) |
| 48 | 3½ X 120 sq. mm (45mm) |
| 49 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 50 | Fire Alarm SystemSupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.a) Two Loop Panel. |
| 51 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 52 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 53 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 54 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 55 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 56 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 57 | Supply, Installation, Testing and Commissioning of laser etched LED exit signage lit laser Eitched Exit sign or anu other sign like hudrant, lift etc made of MS housing powder coated having acrylic sheet etched with super bright LED less than 2 watt having NI-MH/NICD battery with backup of 10 hours of standard size of 300 mm X 150 mm recharge period of 12 hours operating voltage of 190 - 230V complete as required. it should be conforming to all DFS and NBC 2016 specification. a) Exit signage single side along with arrow direction as per requirement at particular location. |
| 58 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 59 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.a) 100mm(W) X50mm(D) X 1.6mm(T) |
| 60 | IEIWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated Copper Conductor Single Core Cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group- C |
| 61 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group- C |
| 62 | Wiring for light/ power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 63 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3X4 Sq.mm |
| 64 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 65 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3X1.5 Sq.mm |
| 66 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3X6 Sq.mm |
| 67 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required. |
| 68 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 69 | 6 Module (200mmX75mm) |
| 70 | 8 Module (125mmX125mm) |
| 71 | 12 Module (200mmX150mm) |
| 72 | Supplying and fixing Two Module Stepped type Electronic Fan Regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 73 | Supplying and fixing 3-Pin, 5 A Ceiling Rose on the existing junction box/ wooden block including connection etc. as required. |
| 74 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) outlets are required. a) 8 way (4 + 24), Double door |
| 75 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double door |
| 76 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure,on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 77 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. a) For 8 way, Double door SPN MCBDB |
| 78 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. a) For 8 way, Double door TPN MCBDB |
| 79 | Supplying and fixing 5 A to 32 A rating, 240/415 volts, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 80 | Double Pole |
| 81 | Supplying and fixing 63 A , four pole (Three phase and Neutral) , 415 V , residual current circuit breaker (RCCB) having a sensivity current 30mA in the existing MCB DB complete with connections, testing and comissioning etc. as required. |
| 82 | Earthing with GI Earth Pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 83 | Providing and fixing 25 mm x 5 mm GI Strip on surface or in recess for connections etc. as required. |
| 84 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 85 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >7 0, under voltage and over voltage protection,EMI-EMC as per CISPR- 15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shal l be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 100 watt |
| 86 | Supplying of the following size of XLPE ARMOURED Cables with ALUMINIUM Conductor 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988. as required at site.2 X10 Sq.mm |
| 87 | 4X35 Sq.mm |
| 88 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 89 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 90 | 4 X 35 sq. mm (32mm) |
| 91 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 92 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 93 | Fabrication, Supplying, Installation, Testing & Commissioning of Electrical Motor Control Panel cubical construction floor/wall mounted, fabricated out of 1.6mm thick CRCA sheet and door made of 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors,dust & virmin proof, powder coated of approved shade, interconnetion with solid aluminium strip/single core PVC insulated FR copper conductor cable, having suitable mountings for switchgear & accessories & internal control & power wiring with suitable rating as required and earth terminals, numbering etc.complete in all respects, suitable for operation on 415 V, 3 Phase 50 HZ AC supply with encloser protection consisting of following material in the panel:- (i) One no. 400 A FP, 50 KA incoming MCCB with ELR. (ii) One set Suitable Aluminium Bus Bar. (iii) 0-500 volts 96 x96 square mm voltmeter with slector switch and control fuses- 1 SET.(iv) 0-200 amps 96 x96 square mm ammeter with CT's and slector switch- 1 SET.(v) Phase indicating lamp with toggle switches. (vi) Indication lamps for ON/OFF/TRIP status Outgoing Feeders (vii) 32 A MCB - 3 Set (viii) 320 A changeover 4P, - 1 Set.(ix) 250A ,FP, 50KA , MCCB-1 No.(x) 100 A ,FP,30KA,MCCB-3 No.(xi) 63 A , FP , 25 KA , MCCB.- 4 No.(xii) Auto manual selector switch as reqd. (xiii) Single phase preventor (xiv) Aluminium Danger plate |
| 94 | Supply of Exhaust Fan (plastic ventilating fan) operating on Single Phase 50 Hz, 230 V, A.C. supply of size 250 mm Sweep alongwith its installation in the existing opening, including making good the damage, connection, testing, commissioning etc. complete as required. |
| 95 | Supply of Heavy Duty Exhaust Fan operating on Single Phase 50 Hz, 230 V, A.C. supply of size 450 mm Sweep alongwith its installation in the existing opening, including making good the damage, connection, testing, commissioning etc. complete as required. (For Pump House) |
| 96 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copperwinding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. a) 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 97 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F. ≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18- 22 Watt |
| 98 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating Please Enable Macros to View BoQ information |