Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Prekshagrih/ Auditorium at Kakor District-Auraiya (U.P.) |
| 2 | MULTIPURPOSE HALLEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 3 | Earth Filling By Avilable Earth |
| 4 | Earth work in filling under floor upto plinth including watering ramming by Cartage Earth |
| 5 | Sand Filling Under Floor |
| 6 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 7 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 (a) in Foundation |
| 8 | (b) In Column |
| 9 | (c) in Lintel G.F. |
| 10 | (d) in Beam |
| 11 | (e) in Slab |
| 12 | Providing and injecting chemical emulsoin for preconstructional antitermite treatment and crsating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc, complete (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981)) Aldrine emusifiable concentrate or any other approved material such as Hepthachlor or chloradane will be used. The rate of application will be used. The rate of application of chemical emulsion shal be as follows:- (1) Treatment for masonary & foundation 5 Liters per SQM. (2). Back fill in intermediate contact with foundation 7.5 Litres per Sq.M. (3) Treatment of top surface of plinth filling 5 Litres per Sq.M. (4) Treatment of soil along external perimeter of Building 7.50 Litres per Sq.M. (5) Treatment of soil under apron along external perimeter 5 Litres per Sq.M. |
| 13 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 14 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 15 | Class- 150 brick work in 1:6 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. G.F. |
| 16 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 17 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc (a) inside |
| 18 | (b) outer |
| 19 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 20 | Providing & Laying Polished Vitrified tiles in Dado different sizes (thickness to be specified by the manufacturer) with water absorption's less than n 0.08% and conforming IS 15622 of approved make in all Colours and shades, laid on 20mm. Thick 1:4 (1cement : 4 Coarse sand) Including grouting the joints with white cement and matching pigment etc. Complete.Size 600*600 mm. |
| 21 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 22 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. |
| 23 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,\ epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 sqm |
| 24 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer |
| 25 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 26 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 27 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 28 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 29 | Making Khurra 45*45 cm with everage minimum thickness of 5 cm cement concrete 1:2;4 (1 cement: 2coarse sand: 4 aggrgate 20mm. Nominal size over P.V.c. sheet 1*1*400Micron |
| 30 | Providing & Applying Two Coat White Cement Based Wall care Putty For Given Smooth surface for Painting complete of work. |
| 31 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 32 | Painting wall with oil bound Distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 33 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 34 | 40mm. Thick Apren Flooring 1:2:4 Cement:C.sand:20 mm. Stone grit with Floting coat of neat cement including supply of all Materials Labour and T & P etc. Complete of Work |
| 35 | S.S Stair Case Railing |
| 36 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter |
| 37 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm Shoe |
| 38 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 39 | S/Fixing of 4mm thick glass pans |
| 40 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35mm. thick (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. D/L |
| 41 | (b) same as above but for S/L |
| 42 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality.Providing and fixing of Lamination of door shutter. |
| 43 | Providing & Fixing of SS Door Bolt (a) 300x16 mm |
| 44 | (b) 250x16 mm |
| 45 | Providing & Fixing of SS Tower Bolt (a) 300x10 mm |
| 46 | (b) 150x10 mm |
| 47 | Providing & Fixing of SS Handles 125 mm |
| 48 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper |
| 49 | Construction of Apren Drain 250x300mm. Internal Section Making with Brick work 1:4 cement c.sand Mortor Plasterd with 1:3 cement c.sand mortor with floting coat of neat cement.including all Material, Labour T.& P. complete of work |
| 50 | Providing and fixing PVC door frame as per specification. |
| 51 | 30mm thick PVC door shutter as per specification |
| 52 | Centering and shuttering including strtting, propping etc. and removel (a) Foundations, footings etc |
| 53 | (b) Columns, pillars, Abutments, posts and struts |
| 54 | (c) Suspended Floor roofs, Landings, balconies and acces plateform with water proof ply 12mm. |
| 55 | (d) Lintels, beams, plinth beams with water proof ply 12mm |
| 56 | Providing and fixing water closet squatting pan ( european type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 57 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required : |
| 58 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 630*450 mm with single 15 mm C.P. brass pillar tap. |
| 59 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 60 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x510 mm bowl depth 200 mm |
| 61 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the wallsand floors wherever required : Range of four half stall urinals with 10 litre P.V.C.\ automatic flushing cistern |
| 62 | Providing and fixing P.V. C. Pipe 6kg.Pis including all Material, Labour T.&P. Complete of work. 110 mm dia. |
| 63 | Providing and fixing P.V. C. Clamp including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 64 | Providing and fixing P.V. C. Bend including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 65 | Providing and fixing P.V. C. N Trape including all Material, Labour T.&P. Complete of work. 90*90mm. |
| 66 | Providing and fixing P.V. C. D. Bend including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 67 | Providing and fixing of P.V.C. Copler For 110 mm dia. |
| 68 | Providing and fixing of P.V.C. Covel 110mm. Ddia |
| 69 | Providing and fixing of P.V.C. D. Tee For 110 mm dia. |
| 70 | Providing and fixing of P.V.C. Tee For 110 mm dia. |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge (a) 20 mm dia. nominal bore |
| 72 | (b) 25 mm dia. nominal bore |
| 73 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 74 | Providing and fixing uplasticised PVC connection pipe with brass unions : (a) 30 cm length 15 mm nominal bore |
| 75 | Providing and Fixing of G.I. Pipe in external work 25mm. dia |
| 76 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 25 mm nominal bore |
| 77 | Cutting holes upto 30x30 cm in walls including making good the same : With F.P.S. bricks. |
| 78 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 79 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore. |
| 80 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. as Such Hindwair 15 mm nominal bore |
| 81 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. as Such Hindwair 15 mm nominal bore. |
| 82 | Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. as Such Hindwair 15 mm nominal bore |
| 83 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 as Such Hindwair 15 mm nominal bore |
| 84 | Providing and fixing of C.P. towel rod 24\\"heavy. |
| 85 | Providing & Placing of polyethylene waterstorage tank, ISI 12701 locking arregment and making necessary holes for inlet, outlet and overflowpipes but without fittings. |
| 86 | Providing & Making of Platefom for 1000 Ltr. P.V.C. Water Storege Tank. |
| 87 | GUEST HOUSEEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 88 | Earth Filling By Avilable Earth |
| 89 | Earth work in filling under floor upto plinth including watering ramming by Cartage Earth |
| 90 | Sand Filling Under Floor |
| 91 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 92 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 in Foundation |
| 93 | (a) In Column G.F. |
| 94 | (b) F.F. |
| 95 | (c) 2nd Floor |
| 96 | (d) in Lintel G.F. |
| 97 | (e) F.F. |
| 98 | (f) 2nd Floor |
| 99 | (g) in Beam |
| 100 | (h) F.F. |
| 101 | (i) 2nd Floor |
| 102 | (j) in Slab |
| 103 | (k) F.F. |
| 104 | (l) 2nd Floor |
| 105 | Providing and injecting chemical emulsoin for preconstructional antitermite treatment and crsating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc, complete (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981)) Aldrine emusifiable concentrate or any other approved material such as Hepthachlor or chloradane will be used. The rate of application will be used. The rate of application of chemical emulsion shal be as follows:- (1) Treatment for masonary & foundation 5 Liters per SQM. (2). Back fill in intermediate contact with foundation 7.5 Litres per Sq.M. (3) Treatment of top surface of plinth filling 5 Litres per Sq.M. (4) Treatment of soil along external perimeter of Building 7.50 Litres per Sq.M. (5) Treatment of soil under apron along external perimeter 5 Litres per Sq.M. |
| 106 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 107 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 108 | Class- 150 brick work in 1:6 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. (a) G.F. |
| 109 | (b) F.F. |
| 110 | (c) 2nd Floor |
| 111 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. PARAPET |
| 112 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc Inside |
| 113 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc outer |
| 114 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 115 | Providing & Laying Polished Vitrified tiles in Dado different sizes (thickness to be specified by the manufacturer) with water absorption's less than n 0.08% and conforming IS 15622 of approved make in all Colours and shades, laid on 20mm. Thick 1:4 (1cement : 4 Coarse sand) Including grouting the joints with white cement and matching pigment etc. Complete.Size 600*600 mm. |
| 116 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 117 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4Coarse sand), including pointing the joints with white cement and matchingpigment etc, complete. |
| 118 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,\ epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm |
| 119 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer |
| 120 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 121 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 122 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 123 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen |
| 124 | Making Khurra 45*45 cm with everage minimum thickness of 5 cm cement concrete 1:2;4 (1 cement: 2coarse sand: 4 aggrgate 20mm. Nominal size over P.V.c. sheet 1*1*400Micron |
| 125 | Providing & Applying Two Coat White Cement Based Wall care Putty For Given Smooth surface for Painting complete of work. |
| 126 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 127 | Painting wall with oil bound Distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 128 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 129 | 40mm. Thick Apren Flooring 1:2:4 Cement:C.sand:20 mm. Stone grit with Floting coat of neat cement including supply of all Materials Labour and T & P etc. Complete of Work |
| 130 | S.S Stair Case Railing |
| 131 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter |
| 132 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm Shoe |
| 133 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 134 | 20mm.thick 1:3 Cement: C.sand Mortor Bearing Plaster with Floting Coat of Neat Cement |
| 135 | S/Fixing of 4mm thick glass pans |
| 136 | Filling of Cinder in Sunken portion of Toilet including Supply of all Material, Labour, T.&P. complete of work. |
| 137 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35mm. thick30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. S/L |
| 138 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality.Providing and fixing of Lamination of door shutter. |
| 139 | Providing & Fixing of S.S. Door Bolt (a) 300x16 mm |
| 140 | (b) 250x16 mm |
| 141 | Providing & Fixing of S.S. Tower Bolt 300x10 mm |
| 142 | Providing & Fixing of S.S. Handles 125 mm |
| 143 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper |
| 144 | Construction of Apren Drain 250x300mm. Internal Section Making with Brick work 1:4 cement c.sand Mortor Plasterd with 1:3 cement c.sand mortor with floting coat of neat cement.including all Material, Labour T.& P. complete of work |
| 145 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood |
| 146 | Providing & Fixing PVC door frames as per specification |
| 147 | 30mm thick PVC door shutter as per specification |
| 148 | Centering and shuttering including strtting, propping etc. and removel (a) Foundations, footings etc |
| 149 | (b) Columns, pillars, Abutments, posts and struts |
| 150 | (c) Suspended Floor roofs, Landings, balconies and acces plateform with water proof ply 12mm. |
| 151 | (d) Lintels, beams, plinth beams with water proof ply 12mm |
| 152 | Providing and fixing water closet squatting pan ( european type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 153 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required : |
| 154 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 630*450 mm with single 15 mm C.P. brass pillar tap. |
| 155 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 156 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x510 mm bowl depth 200 mm |
| 157 | Providing and fixing P.V. C. Pipe 6kg.Pis including all Material, Labour T.&P. Complete of work. 110 mm dia. |
| 158 | Providing and fixing P.V. C. Clamp including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 159 | Providing and fixing P.V. C. Bend including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 160 | Providing and fixing P.V. C. N Trape including all Material, Labour T.&P. Complete of work. 90*90mm. |
| 161 | Providing and fixing P.V. C. D. Bend including all Material, Labour T.&P. Complete of work. For 110 mm dia. |
| 162 | Providing and fixing of P.V.C. Copler For 110 mm dia. |
| 163 | Providing and fixing of P.V.C. Covel 110mm. Ddia |
| 164 | Providing and fixing of P.V.C. D. Tee For 110 mm dia. |
| 165 | Providing and fixing of P.V.C. Tee For 110 mm dia. |
| 166 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge (a) 20 mm dia. nominal bore |
| 167 | (b) 25 mm dia. nominal bore |
| 168 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (a) 25 mm nominal bore |
| 169 | Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore |
| 170 | Providing and Fixing of G.I. Pipe in external work 25mm. dia |
| 171 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 25 mm nominal bore |
| 172 | Cutting holes upto 30x30 cm in walls including making good the same : With F.P.S. bricks. |
| 173 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 174 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore. |
| 175 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. as Such Hindwair 15 mm nominal bore |
| 176 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. as Such Hindwair 15 mm nominal bore. |
| 177 | Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. as Such Hindwair 15 mm nominal bore |
| 178 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 as Such Hindwair 15 mm nominal bore |
| 179 | Providing and fixing of C.P. towel rod 24\\"heavy. |
| 180 | Providing & Placing of polyethylene waterstorage tank, ISI 12701 locking arregment and making necessary holes for inlet, outlet and overflowpipes but without fittings. |
| 181 | Providing & Making of Platefom for 1000 Ltr. P.V.C. Water Storege Tank. |
| 182 | FOOD COURT & KIOKSEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 183 | Earth Filling By Avilable Earth |
| 184 | Sand Filling Under Floor |
| 185 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 186 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 in Foundation (a) plinth band |
| 187 | (b) lintel band |
| 188 | (c) in Slab |
| 189 | Providing and injecting chemical emulsoin for preconstructional antitermite treatment and crsating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc, complete (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981)) Aldrine emusifiable concentrate or any other approved material such as Hepthachlor or chloradane will be used. The rate of application will be used. The rate of application of chemical emulsion shal be as follows:- (1) Treatment for masonary & foundation 5 Liters per SQM. (2). Back fill in intermediate contact with foundation 7.5 Litres per Sq.M. (3) Treatment of top surface of plinth filling 5 Litres per Sq.M. (4) Treatment of soil along external perimeter of Building 7.50 Litres per Sq.M. (5) Treatment of soil under apron along external perimeter 5 Litres per Sq.M. |
| 190 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 191 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 192 | Class- 150 brick work in 1:6 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. G.F. |
| 193 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 194 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc |
| 195 | Providing & Laying Polished Vitrified tiles in Dado different sizes (thickness to be specified by the manufacturer) with water absorption's less than n 0.08% and conforming IS 15622 of approved make in all Colours and shades, laid on 20mm. Thick 1:4 (1cement : 4 Coarse sand) Including grouting the joints with white cement and matching pigment etc. Complete.Size 600*600 mm. |
| 196 | Supply and fixing of rolling shutter etc complite of work. |
| 197 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 198 | Making Khurra 45*45 cm with everage minimum thickness of 5 cm cement concrete 1:2;4 (1 cement: 2coarse sand: 4 aggrgate 20mm. Nominal size over P.V.c. sheet 1*1*400Micron |
| 199 | Providing & Applying Two Coat White Cement Based Wall care Putty For Given Smooth surface for Painting complete of work. |
| 200 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 201 | Painting wall with oil bound Distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 202 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 203 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter |
| 204 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm Shoe |
| 205 | Centering and shuttering including strtting, propping etc. and removel Lintels, beams, plinth beams with water proof pply 12mm |
| 206 | BOUNDARY WALLEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 207 | Earth Filling By Avilable Earth |
| 208 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 209 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 (a) in Foundation |
| 210 | (b) In Column G.F. |
| 211 | (c) in Lintel G.F. |
| 212 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 213 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 214 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc outer |
| 215 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 216 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 217 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 218 | Centering and shuttering including strtting, propping etc. and removel (a) Foundations, footings etc |
| 219 | (b) Columns, pillars, Abutments, posts and struts |
| 220 | (c) Lintels, beams, plinth beams with water proof ply 12mm |
| 221 | M.S. Gate (2 Nos.)Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 222 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 223 | PUMP ROOMEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 224 | Earth Filling By Avilable Earth |
| 225 | Earth work in filling under floor upto plinth including watering ramming by Cartage Earth |
| 226 | Sand Filling Under Floor |
| 227 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 228 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 (a) in Foundation |
| 229 | (b) in Lintel. |
| 230 | (c) in Slab |
| 231 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 232 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 233 | Class- 150 brick work in 1:6 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. G.F. |
| 234 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 235 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc |
| 236 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 237 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 238 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 239 | Making Khurra 45*45 cm with everage minimum thickness of 5 cm cement concrete 1:2;4 (1 cement: 2coarse sand: 4 aggrgate 20mm. Nominal size over P.V.c. sheet 1*1*400Micron |
| 240 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 241 | Painting wall with oil bound Distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 242 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 243 | 40mm. Thick Apren Flooring 1:2:4 Cement:C.sand:20 mm. Stone grit with Floting coat of neat cement including supply of all Materials Labour and T & P etc. Complete of Work |
| 244 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter |
| 245 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm Shoe |
| 246 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 247 | Centering and shuttering including strtting, propping etc. and removel Lintels, beams, plinth beams with water proof ply 12mm |
| 248 | GAURD ROOMEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 249 | Earth Filling By Avilable Earth |
| 250 | Earth work in filling under floor upto plinth including watering ramming by Cartage Earth |
| 251 | Sand Filling Under Floor |
| 252 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 253 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 (a) in Foundation |
| 254 | (b) in Lintel. |
| 255 | (c) in Slab |
| 256 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 257 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 258 | Class- 150 brick work in 1:6 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. G.F. |
| 259 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 260 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc |
| 261 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 262 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 263 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 264 | Making Khurra 45*45 cm with everage minimum thickness of 5 cm cement concrete 1:2;4 (1 cement: 2coarse sand: 4 aggrgate 20mm. Nominal size over P.V.c. sheet 1*1*400Micron |
| 265 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 266 | Painting wall with oil bound Distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 267 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 268 | 40mm. Thick Apren Flooring 1:2:4 Cement:C.sand:20 mm. Stone grit with Floting coat of neat cement including supply of all Materials Labour and T & P etc. Complete of Work |
| 269 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter |
| 270 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm Shoe |
| 271 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 272 | Centering and shuttering including strtting, propping etc. and removel Lintels, beams, plinth beams with water proof pply 12mm |
| 273 | INTERLOCKINGEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 274 | Providig and laying cement concrete 1:4:8 (1cement:4 sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 275 | Class- 75 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 276 | P.C.C. 1:2:4 cement;csand: stone gritt |
| 277 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge With material conforming to Grade-II (size range 53 mmto 0.075 mm ) having CBR Value-25 |
| 278 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc |
| 279 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern. |
| 280 | BORINGBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.300mm. dia |
| 281 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, above 90 metre depth below ground level.300mm. dia |
| 282 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200mm. dia |
| 283 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200mm. dia |
| 284 | Gravel Packing in Tubewell Construction accordanse With IS 4097 |
| 285 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 286 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessarybolts & nuts of required size complete.Supply & Laying |
| 287 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).Supply & Laying of 200mm. Dia M.S. bail plug |
| 288 | K.S.B. make submersible pump 5H.P. |
| 289 | Cantrol Pannel with 100 Amp. Main switch |
| 290 | Flat Copper Cable 1x3x6mm. ISI Mark |
| 291 | Supply of 80 mm. dia M.S. column pipe of c class both side flanged type complete |
| 292 | Supply of Steel wair robe of 1/2\\" size |
| 293 | RAIN WATER HARVESTINGEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. up tp 1.50mtr. |
| 294 | (a) 1.50 to 3.00 mtr. |
| 295 | (b) 3.00 to 4.65 mtr. |
| 296 | Providig and laying cement concrete 1:4:8 (1cement:4fine sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 297 | R.C.C. works with cement approved coarse sand and 20mm gauge approved stone grit in the proportion 1:2:4 (1cement:6aggregate) in lintels of doors and windows excluding supply of reinforcement and its bending& binding. but including its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labours, tools and plants etc required for proper completion of the works. Binding wire cost being included in the item |
| 298 | Centring & Shutring Slab |
| 299 | Edges of Slab |
| 300 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 301 | 15mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc. |
| 302 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 303 | Providing M.S. foot rests including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size) as per standard design : |
| 304 | Providing & Fixing of Posititon Precast RCC Manhole cover and frame of Required shape and approved quailty |
| 305 | Excavating trenches of required width for pipes, cables, etc includingexcavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returningthe soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. anddisposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 306 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipeswith collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 307 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thickwith cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement completeas per standard design : Size 600*600*450 |
| 308 | Supplying and stacking at site.90 mm to 45 mm size stone aggregate |
| 309 | Stone screening 11.2 mm nominal size (Type B) |
| 310 | Red Bajri |
| 311 | Drilling of 300mm. Dia bore hole manually |
| 312 | Supply of 160mm dia rigid PVC pipe (4kg./sqcm pressure rating) and accessories |
| 313 | Supply of 160mm dia sloted rigid PVC pipe (4kg./sqcm pressure rating) and accessories |
| 314 | supply and fixing of nylon jali around the sloted pipes complet as required |
| 315 | Providing and packing of coarse sand around the pipe |
| 316 | transport of Boring tools other required equipments and instalation at site |
| 317 | Lowering of 160mm. Dia rigid P.V.C. pipe in bore hole including cutting jointing etc. complete |
| 318 | TOILET BLOCKEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 319 | Earth Filling By Avilable Earth |
| 320 | Sand Filling Under Floor |
| 321 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 322 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 in Foundation (a) plinth band |
| 323 | (b) lintel band |
| 324 | (c) in Slab |
| 325 | Providing and injecting chemical emulsoin for preconstructional antitermite treatment and crsating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc, complete (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981)) Aldrine emusifiable concentrate or any other approved material such as Hepthachlor or chloradane will be used. The rate of application will be used. The rate of application of chemical emulsion shal be as follows:- (1) Treatment for masonary & foundation 5 Liters per SQM. (2). Back fill in intermediate contact with foundation 7.5 Litres per Sq.M. (3) Treatment of top surface of plinth filling 5 Litres per Sq.M. (4) Treatment of soil along external perimeter of Building 7.50 Litres per Sq.M. (5) Treatment of soil under apron along external perimeter 5 Litres per Sq.M. |
| 326 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 327 | 25mm. Thick D.P.C. 1:1.5:3 cement: c.sand: 13mm. Stone gritt including water Proofing Materials including Supply of all Material, Labour, T.&P. complete of work |
| 328 | Class- 150 brick work in 1:6 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. G.F. |
| 329 | Class- 150 brick work in 1:4 cement and C.sand mortar in Super Structure including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 330 | 12mm wall plaster 1:6 cement :coarse sand including cost of material labour T&P etc |
| 331 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size asapproved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 332 | Providing and laying Ceramic glazed wall tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. |
| 333 | Providing and fixing factory made pvc door frame as per specification. |
| 334 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sum. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 335 | Making Khurra 45*45 cm with everage minimum thickness of 5 cm cement concrete 1:2;4 (1 cement: 2coarse sand: 4 aggrgate 20mm. Nominal size over P.V.c. sheet 1*1*400Micron |
| 336 | Providing & Applying Two Coat White Cement Based Wall care Putty For Given Smooth surface for Painting complete of work. |
| 337 | Finishing walls with 2 Coat Weather coat exterior paint with Silicone additives of required shade |
| 338 | Painting wall with oil bound Distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 339 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 340 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter |
| 341 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm Shoe |
| 342 | 35mm thick factory made solid panel pvc door shutter |
| 343 | Providing & Fixing of S.S. Door Bolt 250x16 mm |
| 344 | Providing & Fixing of S.S. Tower Bolt 300x10 mm |
| 345 | Centering and shuttering including strtting, propping etc. and removel Lintels, beams, plinth beams with water proof pply 12mm |
| 346 | DRAINEarth work in exacavation in trenches for foundations land for pipes cables etc. in ordinary soil (loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. |
| 347 | Providing and laying in cement concrete 1:2:4 (1 cement :4coarse sand :4 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. Same as above but 1:4:8 |
| 348 | Class 150 Brick Work in 1:4 cement and coarse sand of 2.20 fineness modulus mortar in foundation and plinth including supply of all materials, labour and tools and plants etc. required for proper completion of the work. |
| 349 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 350 | 20 mm cement plaster on single or half brick wall finished with a floating coat of neat cement of mix : 1:3(1 cement: 3 Coarse sand) |
| 351 | SEPTIK TANK & SOAK PITEarth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (Loam, clay or sand) including lift up to 1.50M and lead upto 50M and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i.c. within a lead of 30 m. |
| 352 | Earth Filling By Avilable Earth |
| 353 | Providig and laying cement concrete 1:4:8 (1cement:4 C.sand: 8 Stone Ballast 40mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete also including cost of form work in foundation and floors. |
| 354 | R.C.C. works with cement approved coarse sand and 2 cm. (3/4\\") gauge approved stone ballast in the proportion 1:1.5:3 (1cement:1.5csand:3stone grit) excluding supply of reinforcement and its bending& binding. With 24BWG binding wire including supply of all Material,labours, tools and plants etc required for proper completion of the works. Strength of the concrete shall not be less than M-200 in Foundation |
| 355 | Class- 150 brick work in 1:6 cement and C.sand mortar in Foundation including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 356 | 15mm wall plaster 1:3cement :coarse sand including cost of material labour T&P etc |
| 357 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. |
| 358 | 50mm. Thick Flooring 1:2:4 Cement:C.sand:20 mm. Stone grit with Floting coat of neat cement including supply of all Materials Labour and T & P etc. Complete of Work |
| 359 | Brick bats filling in s p |
| 360 | Centering and shuttering including strtting, propping etc. and removel Lintels, beams, plinth beams with water proof pply 12mm |
| 361 | ELECTRIFICATION WORK MP HALLWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 362 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 363 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 364 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 365 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 366 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 367 | (d) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 368 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 369 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 370 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. (a) 5/6 A switch |
| 371 | (b) 3 pin 5/6 A socket outlet |
| 372 | (c) RJ45 socket cat 6 with shutter |
| 373 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 374 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required. 1 or 2 Module (75mmX75mm) |
| 375 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 376 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 377 | Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required. Upto 450 mm sweep |
| 378 | Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes. |
| 379 | Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 380 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 381 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 4 way (4 + 12), Double door |
| 382 | (b) 6 way (4 + 18), Double door |
| 383 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 384 | (b) Double pole |
| 385 | Triple pole and neutral |
| 386 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 387 | Supplying and installing following size of perforated paintedwith powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 388 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. |
| 389 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 390 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. |
| 391 | Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 392 | Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 393 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA |
| 394 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 395 | SITC of 12W Extruded aluminium batten available in 2ft run length with multiple lumen packages and suitable for surface, wall & conduit ounting (with accessories). similar to Philips Type HSN Code MRP (INR) BN 021 LED12S 6500 PSU GR or equivalent. |
| 396 | Supply & Installation of Call Buzzer of approved Make |
| 397 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 398 | Supply of Pressure die cast housing LED bulkhead with IP66protection and IK09 impact resistance suitable for surface and wall mounting applications. Similar to Philips Cat Ref. WT202W LED6S NW PSU S2 PC or equivalent. |
| 399 | Supply & Installation of 450mm Sweep wall fan operating at 230V as per direction of Engineer in charge. |
| 400 | Supply & Installation of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12\\" or equivalent. |
| 401 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 16 sq. mm (28mm) |
| 402 | (b) 3½ X 35 sq. mm (32mm) |
| 403 | (c) 3½ X 95 sq. mm (45mm) |
| 404 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 405 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 406 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 407 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia |
| 408 | 3 Phase Input & 3 Phase Output 10KVA UPS Supply, installation, testing, and commissioning of UPS system with following features1. High freq. PWM inverter using IGBT2. Manual/Auto bypass switch3. SMF batteries to provide approx. 30 min backup time on IT load alongwith battery rack |
| 409 | Main LT PanelDesign, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness.The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. INCOMMER100Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-1 no.BUSBARS1 Nos. 160 Amp FP busbars of aluminium alloy as per SLD.OUTGOING32Amp. 10KA FP MCB 2 No.63Amp. 10KA FP MCCB 3 No.INSTRUMENTS1 sets of multifunction meter with parameter current,voltage, KWH, KVAH, Power factor on incoming from transformers with RS 485 port.1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).1 Sets auto trip indicating lamp . |
| 410 | ELECTRIFICATION WORK GUEST HOUSEWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 411 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 412 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 413 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 414 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 415 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 416 | (d) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 417 | (e) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 418 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 419 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 25 mm |
| 420 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch |
| 421 | (b) 3 pin 5/6 A socket outlet |
| 422 | (c) TV socket outlet |
| 423 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 424 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 425 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 426 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 427 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 428 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 429 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 430 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door |
| 431 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 432 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 433 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 434 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 435 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 436 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 437 | Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 438 | Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 439 | SITC of 12W Extruded aluminium batten available in 2ft run length with multiple lumen packages and suitable for surface, wall & conduit ounting (with accessories). similar to Philips Type HSN Code MRP (INR) BN 021 LED12S 6500 PSU GR or equivalent. |
| 440 | Supply & Installation of Call Buzzer of approved Make |
| 441 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 442 | Supply of Pressure die cast housing LED bulkhead with IP66protection and IK09 impact resistance suitable for surface and wall mounting applications. Similar to Philips Cat Ref. WT202W LED6S NW PSU S2 PC or equivalent. |
| 443 | Supply of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12\\" or equivalent. |
| 444 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 16 sq. mm (28mm) |
| 445 | (b) 3½ X 35 sq. mm (32mm) |
| 446 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 447 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 448 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 449 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia |
| 450 | Main LT PanelDesign, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness. \\"The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. INCOMMER100Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-1 no.BUSBARS1 Nos. 125 Amp FP busbars of aluminium alloy as per SLD.OUTGOING63Amp. 10KA FP MCCB 2+1 No. INSTRUMENTS1 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers with RS 485 port.1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).1 Sets auto trip indicating lamp . |
| 451 | ELECTRIFICATION WORK TOILETWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 452 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 453 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 454 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 455 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch |
| 456 | (b) 3 pin 5/6 A socket outlet |
| 457 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 458 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 459 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 460 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 461 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 462 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door |
| 463 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 464 | (b) Double pole |
| 465 | Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 466 | Supply of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12\\" or equivalent. |
| 467 | ELECTRIFICATION WORK FOOR COURTWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 468 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 469 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 470 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 471 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 472 | (d) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 473 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 474 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 475 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch |
| 476 | (b) 3 pin 5/6 A socket outlet |
| 477 | (c) TV socket outlet |
| 478 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 479 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 480 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 481 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 482 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 483 | Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes. |
| 484 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 485 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 486 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 487 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 488 | (b) Double pole |
| 489 | Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent. |
| 490 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 491 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. |
| 492 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 493 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required. |
| 494 | Supply of 8W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 495 | Supply of 15W Green Perform Sleek is a high performance low-height LED downlighter suited for requirements of any modern professional workspace. Robust PDC housing ensures long system. Narrow rim renders a pleasing aesthetic look. similar to Philips DN295B LED8S-6500 PSU WH or equivalent. |
| 496 | SITC of 12W Extruded aluminium batten available in 2ft run length with multiple lumen packages and suitable for surface, wall & conduit ounting (with accessories). similar to Philips Type HSN Code MRP (INR) BN 021 LED12S 6500 PSU GR or equivalent. |
| 497 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 498 | Supply of Pressure die cast housing LED bulkhead with IP66protection and IK09 impact resistance suitable for surface and wall mounting applications. Similar to Philips Cat Ref. WT202W LED6S NW PSU S2 PC or equivalent. |
| 499 | Supply of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12\\" or equivalent. |
| 500 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 16 sq. mm (28mm) |
| 501 | (b) 3½ X 35 sq. mm (32mm) |
| 502 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 503 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm |
| 504 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 505 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia |
| 506 | Main LT PanelDesign, Manufacturing, Supply, Commissioning & Testing of Main LT Panel. The panel will be totally enclosed type with, free standing, floor mounted, indoor duty, dust & vermin proof, , front operated, electrical panel fabricated from 2 mm thick M.S. Sheet as per specifications & drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter, indication lamps, CT's, protection MCB, interconnection wiring, earth bus and will be powder coated finish with 50 micron thickness. The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to achieve electrical interlocking, synchronizing, buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and specification. Each incoming breaker will have microprocessor based releases and all outgoing breaker will have minimum electrostatic releases over 250A & thermal magnetic release below 250A. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 35 MVA. INCOMMER100Amp. 16KA FP With S/C, U/V, E/F Protection MCCB-1 no.BUSBARS1 Nos. 125 Amp FP busbars of aluminium alloy as per SLD.OUTGOING32Amp. 10KA FP MCB 2 No.63Amp. 10KA FP MCCB 3INSTRUMENTS1 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power factor on incoming from transformers with RS 485 port.1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).1 Sets auto trip indicating lamp . |
| 507 | FIRE ALARM SYSTEM - MP HALLSupplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 508 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 509 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 510 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 511 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 512 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.6 zone panel for fire alarm system100 watt amplifier racks suitable for operation on 230VAC/24V DC supply conforming to IEC-268-3 complete with allTalk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of differentzones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No.Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 513 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 514 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 515 | FIRE ALARM SYSTEM- FOOD COURTSupplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 516 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/ recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 517 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 518 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 519 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 520 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.6 zone panel for fire alarm system100 watt amplifier racks suitable for operation on 230VAC/24V DC supply conforming to IEC-268-3 complete with allTalk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of differentzones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No.Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 521 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 522 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 523 | EPABX & NETWORKING SYSTEM WORKSITC of IP-PBX WITH REDUNDANT CPU & REDUNDANT POWER SUPPLY 16 CO TRUNK, 200 ANALOG EXTENSION, 20 SIP TRUNK, 4 E1 PRI TRUNK, 15 IP EXTENSION, PMS INTEGRATION |
| 524 | SITC of REDUNDANT FCBC WITH 12V BATTERIES WITH 15AH CAPACITY |
| 525 | SITC OF IP PHONE WITH DISPLAY |
| 526 | SITC OF BASIC PHONE WITH CLI |
| 527 | S/f of I/O Boxes Krone connectors ,with connection etc. (a) 20 Pair |
| 528 | (b) 50 Pair |
| 529 | (c) 100 Pair |
| 530 | (d) 200 Pair |
| 531 | Wiring of Jelly Filled telephone Cable in existing pipe for system with connection. (a) 20 Pair |
| 532 | (b) 50 Pair |
| 533 | (c) 100 Pair |
| 534 | (d) 200 Pair |
| 535 | Supplying, installing, testing and commissioning of 24 port CAT6 jack panel loaded as per the connections required in jack panel. |
| 536 | Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus |
| 537 | Supplying, installing, testing and commissioning of 42 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 538 | SITC of 2m long Cat-6 patch cord as required |
| 539 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 100mm Dia |
| 540 | S/F of Surface mount box with I/O Cat 6 and UTP jack D-Link complete in all respect Make Dlink/Amp |
| 541 | S/I of Patch cord CAT6 UTP Make Dlink/Amp |
| 542 | S/I/T/C of 24 port category 6e SL Series patch Panel Make Dlink/Amp with active and passive components,punching, complete in all respect |
| 543 | S/I/T/C of 24 port 10/100/1000 Base T Standalone Gigabit Switch Make Dlink/Amp with active and passive components, punching, complete in all respect |
| 544 | Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 545 | Mapping of Network Nodes & LAN Diagram |
| 546 | CCTV SURVEILLANCE SYSTEM WORKSupplying and drawing 4 pair un-shielded twisted pair (UTP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n-capping as required.Supplying and drawing 4 pair un-shielded twisted pair (UTP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n-capping as required. |
| 547 | Supply, Installation, Commissioning of 24 Port Patch Panel loaded with Category-6A I/O shielded Jacks complying as per the ANSI/TIA-568C.2 Patch Panel, 19\\" Rack Mount, 1U Height, I/O should be Spring-loaded shutter to protects from dust and contaminants, Should be certified by ETL/UL |
| 548 | CAT6A RJ - 45 computer socketwith shutter modular (1Module) Category-6A as per ANSI/TIA- 568-C.2, I/O should be Spring-loaded shutter or cap to protects from dust and contaminants, Wire AccoSModation: 22‐24 AWG solid, Should be certified by ETL/UL |
| 549 | Supply, installation testing and commissioning of wall mounting rack, for computer switches/Patch Panel etc complete as mentioned below :-6U cabinet with min. Dimensions 366X600X600, wall mounting with 6 point 5 Amp. socket power supply strip, and fan, cable manager, tray as per Site requirement |
| 550 | Supply, installation testing and commissioning of 24 port PoE switch with 4 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTPCat. 5, Cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 56 GBPS, maximum 64 bytes packet forwarding rate, 41.7mbps, Ports 1 to 24 compliant with 802.3 at |
| 551 | The work station shall have the following specifications:- Processor Intel @ i5 750 2.66 GHz with internal memory of 4 GB RAM.Operating system window 7professional 64-bit (WOW 64mode) or window 7 professional 32-bit NVIDIA 1 GB independent graphic card. Resolution support for cameras 2560x1600 display resolution capable and direct X true colour 32 bit. Dual link VDI outputs. Clientsoftware shall support Dual monitors each displaying 16 cameras simultaneously. A maximum of 32 cameras viewing per workstation at a time. Programmable to sequence. |
| 552 | Supply, installation, testing & commissioning of L.E.D. Television(4K L.E.D. Display O.S. Webos /Android or equivalent, minimum 50Hz refresh rate Min. 20 W speaker, Wifi/bluetooth enabled, minimum 2 HDMI & 1USB Port, i/c remote and wall/table top accessories) 55'' |
| 553 | Supply, installation testing and commissioning of High-Speed HDMI corrosion-resistant connector & braided cable, Supports Ethernet, 3D, 4K video, computers and other HDMI-enabled devices Black as required to complete the job as mentioned below :-2 Metre, HDMI cord |
| 554 | Supply installation testing and commissioning of SFP module. |
| 555 | SITC of 3 Mtr CAT6 A SHIELDED TWISTED PAIR PATCH CORDS ETL/UL. |
| 556 | Supply and fixing PVC conduits required confirming to IS 9537(Part-3), ISI marked along with the accessories in concealed system etc. as required. PVC. conduit 25 mm (HMS) |
| 557 | 2 MP IP IR eyeball camera with H.265 video compressionSupply, installation testing and commissioning of the IP mini dome camera shall be equipped with a 1/3″ 2 MP progressive scan CMOSimager to capture full HD 1080p (25/30 fps) images, a 2.8 mm fixed lens, and a waterproof (IP66) enclosure. As a true day/night solution, the camera shall use smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:-0.08 lux color @ F2.0 (color, 1/3s, 30 IRE),0 lux B/W with IR LEDs on @ F2.0) video compression :- H.265 +, noise reduction: 3DNR,backlight compensation :- BLC/HLC/DWDR, UL listed |
| 558 | 2 MP IP IR eyeball camera with H.265 video compressionSupply, installation testing and commissioning of the IP bullet camera shall be equipped with a 1/2.9\\" 2MP progressive scan CMOS imager to capture full HD 1080p (25/30 fps) images, a 3.6 mm fixed lens, and a waterproof (IP66) enclosure. As a true day/night solution, the camera shall use smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:-0.08 lux color @ F2.0 (Color, 1/3s, 30 IRE),0 lux B/W with IR LEDs on @ F2.0) video compression :- H.265 +, noise reduction: 3DNR,backlight compensation :- BLC/HLC/DWDR, UL listed |
| 559 | 8 MP IP IR fixed lens bullet cameraSupply, installation testing and commissioning of the IP bullet camera shall be equipped with a 1/2.5″ 8 MP progressive scan CMOS imager to capture ultra HD 4K/8 MP resolution at 15 fps or3 MP at 25/30 fps, a 4.0 mm fixed lens, and a waterproof (IP66) IK10 impact-resistant camera housing, as a true day/night solution, the camera shall use smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:0.07 lux (color)/0 lux (B/W) @ F2.0 (with IR LEDs on)) video compression :- H.265 , noise reduction: 3DNR,Backlight Compensation :- DWDR, angle of view horizontal: 88° vertical: 48°,UL listed |
| 560 | Supply, Installation testing and commissioning of 64 channel NVR With 1080p real-time live view H.265/H.264 MJPEG dual codec decoding up to 12 MP resolution preview & playback max 320 MBPS incoming bandwidth support 8 SATA HDDs up to 64TB, supports fisheye video de-warping in local and web user interface, supports visual or auditory notifications(a flashing light, bell, or siren) complete with UL certification |
| 561 | Supply, installation testing and commissioning of 32 channel NVR with 1080p real-time live view H.265/H.264 MJPEG dual codec decoding Up to 12 MP resolution preview & playback max 320 MBPS incoming bandwidth support 8 SATA HDDs up to 64TB, supports fisheye video de-warping in local and web user interface, supports visual or auditory notifications(a flashing light, bell, or siren) complete with UL certification |
| 562 | EXTERNAL ELECTRIFICATIONSupply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,200A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following.a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc.b. 1 Set of cross arms, branching, clamps and painting complete with GI nut, bolts & washers as required (for GO & DO), LA connection.c .1 set 11KV Insulator complete with spindles & hardware complete as required.d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement.e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses, and mounting arrangement.f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases.g. 4 No. 150 mm dia 6 meter long GI pipe class 'B' (for XLPE cable protection) as required.h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA)i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices.11 KV Double Pole Structure described below |
| 563 | Supply of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade as per requirement. 240 sq. mm 3 core |
| 564 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm |
| 565 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm |
| 566 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm |
| 567 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300 mm dia |
| 568 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 200mm Dia |
| 569 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm |
| 570 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm |
| 571 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. |
| 572 | Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. |
| 573 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 574 | Supply and laying of PVC Insulated, FRLS Round Sheathed Multi Core Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volts as per direction of engineer incharge. 10CX2.5Sq.mm |
| 575 | HT PanelS.I.T.C. of VCB's Indoor Type as per latest specification of UP Power Corporations, make prefered Cromptron,Schneider or any Equivalent make approved by UP Power Corporation. Including construction of Plinth and earthing etc. with all material as per Technical Requirment. with 05 years warranty11 KV Outgoing 2 Nos. |
| 576 | TRANSFORMER Providing, erecting, testing & commissioning approved make oil immersed naturally ONAN cooled, double wound, core type outdoor copper wound 11 kV/ 433 Volts Step Down Transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed and On Load Tap Changer continuously rated for a full temperature rise in oil not exceeding 40 deg. C at maximum ambient temp. Of 50 deg. C complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with I.S. 1180 LEVEL 2 standards On load tap changing range steps -10% to 5% on H.V in steps of 1.25% .and L.V. for variation should be provided The H.V. shall be connected delta & secondary with star connection. The transformer should have cable-end boxes on H.T. side & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers. Losses As per IS 1180 LEVEL-2.1. Coservator with plain oil level gauge and oil drain plug 1nos.2. Top filter valve 1 Nos.3. Bottom filter-Cum-drain valave 1Nos..4. Rating and diagram plate 1nos.5. Earthing Terminals 2Nos.6. Thermometer pockets 1Nos.7. Lifting Lugs 2/4 Nos.8.Air release plug 2/4 Nos.9. Bi-directional rollers 4Nos.10.Jacking pads 1Nos.11.Presure relese valve 1Nos.12. Separate Bare LV neutral 433V 13. Detachable/Fixed type radiators 1Nos.14. Magnet Oil level gauge15. Oil temperature indicator 1Nos.16. Winding temperature indicator 1Nos.17. Marshlig Box single window 1No.18. Double flot buchholz's relaywith alarm and trip contact.19. RTCC PanelCOPPER WOUND 320KVA 11/.433V |
| 577 | D.G. SET Supply , Installation, Testing & Commissioning of of 320 kVA, 415V, Radiator Cooled, Silent Type Sterling Generators acoustic enclosure, CPCB-IV complied diesel generating set powered with suitable capacity prime duty Engine, at 40degC, 50Hz, 415V, 1500RPM, developing 657 bhp, 6 cylinder, Fuel injection type HPCR, G3 Governing class, Alternator (capable of delivering true 400 kW output @ 0.8 power factor), mounted on common base frame Static Excitation System, Lube Oil System, Electronic Governor including DG Sync Controller without any breaker (MCCB / ACB), AVM pads, 24 volt DC lead acid batteries, residential grade silencer with bellows inbuilt Day oil tank, initial fill of lube oil & coolant with all other associated equipment / work complete in all respect.250 KVA |
| 578 | MAIN L.T PANELSITC of LT switchgear panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The Panel shall also be capable to communicate status like ON/OFF/ Trip through Modbus/Ethernet for major component like ACB, MCCB, MCB & Multifunation meters.The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfault protection with Current & Voltage metering & LCD display.Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release with LSIG protection functionand should not derate upto 50 decree Centrigrate as per testing guideline as per IEC 60947-2 and all the ACB upto 2500Amp ACB should have same frame size LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics)INCOMING\\"1 Nos. 630 Amp FP EDO ACB 36KA LSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture From 800KVA Transformer having R,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCBInbuilt Zone Slelective Interlocking functionMultifunction Meter\\"\\"1 Nos. 400 Amp FP MCCB 36KA LSIG having S/C, E/F O/C protection, LCD Display having specs as per attached annexture From 200KVA Solar Power Backup having R,Y,B Phase indication Lamp with control MCB On, Off, Trip Status Indication with control MCBInbuilt Zone Slelective Interlocking function Multifunction MeterReverse Power Relay Power Conditioning Device\\"BUSBARS800 Amp FP busbars of aluminium alloy as per SLD.AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's.Load Management through PLCContactor for Load Management SystemAuto changeover.Buscoupler switching.Electrial & Mechnical Interlocking.Synchonization through PLCContactor for Synchronizing SystemAuto changeover and auto load balancing, load management, auto On and Off of DG set as per load requirement.Buscoupler switching.Electrial & Mechnical Interlocking.OUTGOING\\"2 Nos. 400 Amp FP MCCB 36 KA, having specs as per attached annexture having R,Y,B Phase indication Lamp with control MCBOn, Off, Trip Status Indication with control MCBFire Fighting + Spare\\"\\"2 Nos. 250 Amp FP MCCB 36 KA On, Off, Trip Status Indication with control MCBMultifunction MeterSTP + WTP + Spare\\"2 Nos. 100 Amp FP MCCB 25 KA On, Off, Trip Status Indication with control MCBMultifunction MeterT-IV+FP+Spare\\"Short Circuit Breaking capacity should not less than 50KA.RELAYS AS PER SLD |
| 579 | 250KVAR HPFC PANEL TTASITC of HPFC panels suitable for 433 V, 3 phase, 4 wire, 50 Hz power factor correction system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as per specifications and drawings as required. The panel shall withstand the fault level of 50kA as per Single Line Diagram. The APFC Panel shall use all draw out type breakers suitable for 415 V AC, 3 phase, 50 Hz, 3 phase 4 wire supply system. Panel shall have Buscoupler switching, auto operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, auto changeover etc and having following incomming and outgoing Air Circuit Breakers,microprocessor release for overload, short circuit, instantaneous & earthfault protection with Current & Voltage metering & LCD display.Air Circuit Breaker with microprocessor release ge metering & LCD display , with ready to clsoe indicator, should have capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet and as per the detail specification of ACB (Icu=Ics=Icw=65 KA (1 sec). MCCB, with microprocessor release with LSIG protection function LCD display for fault trip history, haivng current limiting feature, double break mechanism & capability to communicate ON /OFF/ Trip Status on Modbus/Ethernet. (65 KA Ics)3 Nos. capacitor duty contactor (one for each 100KVAR capacitor unit).1 Nos. capacitor duty contactor (one for each 50KVAR capacitor unit).5 Nos. capacitor duty contactor (one for each 25KVAR capacitor unit).2 Nos. capacitor duty contactor (one for each 10KVAR capacitor unit).1 Nos. capacitor duty contactor (one for each 5KVAR capacitor unit).3 Nos. 100 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% 1 Nos. 50 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% 5 Nos. 25 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% 2 Nos. 10 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% 1 Nos. 5 KVAR super heavy duty mix dielectric low loss Capacitor suitable for non leniar loads upto 20% 16 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector switches.1 No. Indicating lamp for each capacitor unit to indicate that the unit is 'ON'.1 No. Toggle switch for changing automatic to manual operation of capacitor units.Power factor meter.1 No. 0 to 1000 Amp ammeter with selector switch & C.T's.1 No. 0 to 500 Volts voltmeter with selector switch. |
| 580 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade in existing RCC / Hume / metal pipe as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 70 sq. mm 3-1/2 core |
| 581 | (b) 95 sq. mm 3-1/2 core |
| 582 | (c) 150 sq. mm 3-1/2 core |
| 583 | (d) 240 sq. mm 3-1/2 core |
| 584 | (e) 300 sq. mm 3-1/2 core |
| 585 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on cable tray as directed by engineer incharge complete in all respect including The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 50 sq. mm 3-1/2 core |
| 586 | (b) 70 sq. mm 3-1/2 core |
| 587 | (c) 95 sq. mm 3-1/2 core |
| 588 | (d) 150 sq. mm 3-1/2 core |
| 589 | (e) 240 sq. mm 3-1/2 core |
| 590 | (f) 300 sq. mm 3-1/2 core |
| 591 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (a) 50 sq. mm 3-1/2 core |
| 592 | (b) 70 sq. mm 3-1/2 core |
| 593 | (c) 95 sq. mm 3-1/2 core |
| 594 | (d) 150 sq. mm 3-1/2 core |
| 595 | (e) 240 sq. mm 3-1/2 core |
| 596 | (f) 300 sq. mm 3-1/2 core |
| 597 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 300mm Dia |
| 598 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 200mm Dia |
| 599 | Supply installing testing & commissioning of out door type IP66 with additional canopy street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below.Incoming100 Amp. 10 KA FP MCCB 1 No.Suitable digital contractor and timer for down & dusk100 Amp. TPN Alu. Bus barOutgoing25 Amp. 10KA FP MCB 6 No.40 Amp. 10KA FP MCB 4 No. |
| 600 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade in existing RCC / Hume / metal pipe as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (a) 6 sq. mm 4 core |
| 601 | (b) 16 sq. mm 4 core |
| 602 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (a) 6 sq. mm 4 core |
| 603 | (b) 16 sq. mm 4 core |
| 604 | Providing, laying and fixing following dia RCC pipe NP2 class(light duty) in ground complete with RCC collars, jointing withcement mortar 1:2 (1 cement : 2 fine sand) including trenching(75 cm deep) and refilling etc as required. 300mm Dia |
| 605 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia |
| 606 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. |
| 607 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. |
| 608 | Supply and laying of 25 mm X 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. |
| 609 | Supply and fixing of 1 no. 8SWG GI wire in 15mm dia GI pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
| 610 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. |
| 611 | Supply and fixing of LED Street light Fitting having die cast aluminium body toughen glass/UV Stablized PC cover and lenses for 52 watt to 72 Watt. Confirming to IP66 IK 07 with above Protectionhaving company LOGO engraved complete in all respect.7200-8640 system lumen, High Power LED with lenses , >120lm/W, PF>0.95, potted driver set in metal housing (Not circuitry) Phase to phase protection at 440V, >300V auto cut and restart feature, 4KV internal surge protection with 5 year warrenty. CAT-AAA |
| 612 | Supply and fixing of 16 mtr High mast Pole of approved make with rising system, hot dip Galvanized inside & outside , having pole sheet thickness 4mm, top dia minimum150mm, bottom dia minimum 360mm, base plate 32mm thick, suitable for wind velocity as per IS 875 part 3 &.having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes,1 HP Power tool motor, 3 point suspension system with steel wire rope 6mm dia , double drum winch. Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers, anchor plates etc. Complete in all respect as per direction and satisfaction to the Engineer-in-charge. |
| 613 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 to 120 Watt. Confirming to IP 65 IK 07 protection complete in all respect.12000-14400 system lumen, High Power LED with lenses , >120lm/W, PF>0.95, THD<10% at full load, CRI>70,potted driver set in metal housing (Not circuitry) Phase to phase protection at 440V, >300V auto cut and restart feature, 4KV internal surge protection with 5 year warrenty. CAT-AAA |
| 614 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. |
| 615 | Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. |
| 616 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 617 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 618 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 619 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 620 | Lightning Arrestor: Supply, installation, testing and commissioning of External Lightning wide area protection system based on Eaarly Streamer Emission (ESE) technology. Device shall emit electromagnetic impulse in the form of a streamer into the air microseconds earlier than naturally formed streamers. Device confirmg to NFC 17-102 and UNE 21186 Standards. Appropriate non penetrating mounting arrangement. The device shall be mounted at suitable clear to the highest point on the roof top. (Model selected shall give coverage of 79 M radius @ min 5M height from terrace) |
| 621 | Down conductor:Supply, installation, testing and commissioning of 70 Sqmm twisted 19-Strand, bare Cu cable on surface/wall / as per site requirement and complete in all respect. |
| 622 | Lightning Counter :Supply and installation of counting the number of lightning strikes without any power supply. |
| 623 | Test Link :Supply and installation of test link in weather proof IP 65 BOX. |
| 624 | Supply, installation, testing and commisioning of 2 x 25W LED Aviation abstruction light medium bay type 62, complete with lamp, lamp holder, Condenser necessary connecting wire, 1 X 25 AV with all necessary hardware, accessories as required for complete installation. Rate shall include the cost of necessary steel structures , fixing arrangements in this item. Refer drawing. |
| 625 | 2kg capacity seamless Alluminium cylinder Paso approved stored pressure type clean agent fire extinguisher alongwith all necessary fitting filled with clean agent FK-5-1-12 complete having operating pressure between 15 bar etc. as required UL & FM listed gas. |
| 626 | 5kg capacity seamless Alluminium cylinder Paso approved stored pressure type clean agent fire extinguisher alongwith all necessary fitting filled with clean agent FK-5-1-12 complete having operating pressure between 15 bar etc. as required UL & FM listed gas. |
| 627 | SITC of Pneumatic Heat detection tube red color made by special modified polyamide (PA), UL and LPCB standard, having burst temperature 100°C to 120°C, inner diameter 4 mm, outer diameter 6 mm, pressurized with nitrogen at 15 bar pressure for automatic detection and suppression system |
| 628 | SITC of End of line adapter along with pressure gauge working pressure 25 bar. UL approved. |
| 629 | SITC of End of Line Plug for automatic fire suppression System used for fitting at tube end to terminate the point. Fitting made by brass nickel plated material. UL approved. |
| 630 | SITC of Pressure Switch at 15 bars. UL approved. |
| 631 | SITC of T connection suitable for 4 / 6 mm. diameter pressurized tubes, brass nickel plated material with maximum working pressure 25 bar. UL approved. |
| 632 | SITC of Master Control Unit micro processor based 4 zone inbuilt GSM dialer audio visual alarm control panel, 2NO/NC potential free relay contacts discharge LED indicator, battery LED indicator, system status indicator and AC power ON LED indicator with inbuilt battery backup 24h . |
| 633 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness |
| 634 | (b) 300 mm width X 50 mm depth X 1.6 mm thickness |
| 635 | (c) 450 mm width X 62.5 mm depth X 2 mm thickness |
| 636 | (d) 600 mm width X 62.5 mm depth X 2 mm thickness |
| 637 | (e) 900 mm width X 62.5 mm depth X 2 mm thickness |
| 638 | Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conformington MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, netmetering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years.b)Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and 400VAC, three phase, 4wire, 50Hz+/-2.5Hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0to50degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for in coming and outgoing cable alongwith glands, lugs and other accessories etc. as required.\\"e) Lightning and surge voltage protection .f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel /conduit lugs and other accessories etc. as required.1kWp |
| 639 | INTERNAL & EXTERNAL FIREFIGHTING WORKSupplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required. (Terrace Pump ) 900 LPM 35 mtr head |
| 640 | Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 641 | Supply, installation, testing & commissioning of flow switches with two no and two NC contacts with necessary nipply & other fittings, Flow switch shall be suitable for 150 dia. |
| 642 | Supply, erection and testing of ISI marked M.S. pipes (class B) and specials etc. (as per IS:1239) for above ground laying for hydrants system includeing transportation of materials upto the worksite, cuttings the pipes to required length, edge preparation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges expansion joints wherever required, washers, nuts, bolts etc. in proper position including all supports as per layout. 100 mm dia |
| 643 | Supply, Installation, testing and commissioning of Fire Hydrant valve , bearing to IS:5290 marks, S.S. ,IS: 304 Grade, 63mm oblique instantaneous single out let, 75mm N.B. flanged inlet, brass spindles complete with PVC blank cap . G.I. chain etc. |
| 644 | supply, Installation, testing and commissioning of Branch pipe . S.S. short type with 63mm male instantaneous inlet, male threaded outlet fitted with 15mm, Bore nozzle,having IS: 903 |
| 645 | supply, Installation, testing and commissioning of Fire Hose,RRL hose jacketed with circular woven synthetic fibre,conforming to IS 636:88 63MM DIA.x 15mt. Long with SS 63mm 2 pair of male and female instantaneous coupling having IS :903 mark and duly S.S. wire wounded. The hose shall be rolled and hug to suitable M.S. support in the fire station. |
| 646 | supply, Installation, testing and commissioning of manual swing type Fire hose reel IS:884 comp. with heavy duty reel, 19mm dia. X 30 mtr. Long 2- ply polyster yarn braided / rubber braided pressure hose with heavy duty nylon on/off jet/ spray nozzle, 25mm isolating valve and all other necessory. Please Enable Macros to View BoQ information |
| 647 | supply, Installation, testing and commissioning of manual swing type Fire hose reel IS:884 comp. with heavy duty reel, 19mm dia. X 30 mtr. Long 2- ply polyster yarn braided / rubber braided pressure hose with heavy duty nylon on/off jet/ spray nozzle, 25mm isolating valve and all other necessory. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail