| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of (unreinforced) cement concerete in ground floors and paving not exceeding 15 cm thickness (below or above Ground Level) complete all as specified and directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 7 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as spd and directed. |
| 8 | Dismantling of wall/ceiling board as in ceiling and lining of any gauge or any thickness including cover fillets complete all as specified and directed. |
| 9 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, unframed work, etc complete all as specified and directed. |
| 10 | Dismantling of timber fillets rails, posts, rafters, purlins etc under 40 Sqcm in section, in any position in unframed work etc complete all as specified and directed. |
| 11 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc completed all as specified. |
| 12 | Taking down,Chowkhats or frames not exc. 1.5 sq. m each, but with shutters (without taking off shutters from the frames),etc complete all as specified and directed. |
| 13 | Taking down, Chowkhats or frames exc 1.5 sq. m but n exc 4.0 sq. m each but with shutters (without taking off shutters from the frame),etc complete all as specified and directed. |
| 14 | Taking down shutters any description exc 1.0 sq. m and n exc 2.0 Sqm each removing to store or from store complete all as specified and directed. |
| 15 | Taking down shutters any description n exc 1.0 sq. m a each removing to store or from store complete all as specified and directed. |
| 16 | M&L for sand filling in foundation,under interlocking paver blocks in layer of 25mm/50mm thick or more in foundation as sand cushioning including watering and consolidation complete all as specified and directed. |
| 17 | M&L for machine pressed precast concrete 80mm thick rubber moulded, designer, interlocking paver blocks made of M-40 design mix concrete of approved design and shape with the crushing strength not less than 400kg/sqcm conforming to IS: 15658-2006, and filling the joints over 50mm sand cushioning including all necessary cutting, notching etc complete all as specified and as directed |
| 18 | M & L 100 mm thick PCC 1:4:8 type D-2 ( 40 mm graded stone aggregate) as in fliiling/sub base to floors etc complete all as specified and ditected. |
| 19 | M&L for PCC 1:3:6 type C-2 (using 40mm stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed |
| 20 | M & L plain cement concrete 1:3:6 type C-1 (20mm graded Aggregate as in surface channels and drains complete all as specified directed by Engineer In charge. |
| 21 | M & L Precast cement concrete 1:3:6 type C-1 using 20 mm graded aggregate) block masonry with solid blocks n. exc 10 cm in width and set in cement mortar 1:6 complete all as specified and directed |
| 22 | M & L for precast PCC bond stone of 1:3:6 type C-1 using 20 mm graded stone aggregates) for retainning wall ,abutment and similar works (set in cement mortar 1:6) including necessary formwork Complete all as specified and directed |
| 23 | M & L for 100 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in floorings, pavings and similar work complete all as specified & directed. |
| 24 | M & L for PCC 1:2:4 type B-1 using 20 mm( graded stone aggregates) as in copings inclding form work etc all as specified Complete all as specified and directed |
| 25 | Material and labour walling of random rubble, cement mortar 1:6 regular coursed,well bonded,bedded and solidly hearted, built in etc complete all as specified and directed by Engr-in-charge. |
| 26 | Material and labour walling of random rubble, cement mortar 1:6 regular coursed,well bonded,bedded and solidly hearted, built in etc with used old stone boulder complete all as specified and directed by Engr-in-charge.Note : Old stone boulder obtained from relevant demolished items shall be used. |
| 27 | M&L for raised pointing to random rubble, coursed in CM (1:3) Complete all as specified and directed. |
| 28 | Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair etc completed all as specified and as directed. |
| 29 | Material and labour for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layers 15 mm thick in cement mortar (1:6) for laying floor finishes completed all as specified and as directed. |
| 30 | Material and labour for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including over backin or bedding layers 10 mm thick in cement mortar (1:4) for laying floor finishes completed all as specified and as directed. |
| 31 | Material and labour for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layers 15 mm thick in cement mortar (1:6) for laying floor finishes completed all as specified and as directed. |
| 32 | M & L for Glazed ceramic tiles in vertical surface 350x250x7mm /450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match set and jointed in neat cement slurry and pointed in white or colored cement to match including 10 mm thick rendering with rough finished in cement mortar 1:4 to received tile etc, completed all as specified & directed. |
| 33 | Supply and fix 0.63 mm thick corrugated galvanised steel sheetings with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts and washers as in roof , wall etc with grade of zinc coating 275 gm/sqm etc completed all as specified and as directed. |
| 34 | S & F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and complete all as specified and directed. |
| 35 | Supply and fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws completed all as specified and as directed. |
| 36 | Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 37 | S & F Framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. |
| 38 | S&F pressed steel frames for door of size 125mmx60mm with one or more rebates including necessary fixing lugs, hinges, locks stricks plates etc complete all as specified as directed by the EIC |
| 39 | S&F pressed steel frames for door of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, locks stricks plates etc complete all as specified as directed by the EIC. |
| 40 | S & F 2nd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails or brads of sectional area exc 13 but n exc 25 Sqcm completed all as specified and as directed. |
| 41 | S & F 2nd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails or brads of sectional area exc 6 but n exc 13 Sqcm completed all as specified and as directed. |
| 42 | S & F 2nd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails or brads of sectional area exc 3 but n exc 6 Sqcm completed all as specified and as directed. |
| 43 | M & L for Plain, solid 2nd class class hardwood, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered ,put together with glue pinned at joints, supplied and fixed completed all as specified and as directed. |
| 44 | S & F Second class hardwood clean sawn timber framed and fixed scantlings and replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store completed all as specified and as directed. |
| 45 | S&F factory made 2nd class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mmB.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated completed all as specified and as directed. |
| 46 | S&F 2nd class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc,sizes of members of shutters as specified in SSR part I, Section 8, clause 8.24 (a),fitted to chowkat etc complete all as specified and as directed. |
| 47 | Supply and fix 30mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars,. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats completed all as specified and as directed. |
| 48 | Supply and fix PVC door frame of size 50mm X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening but wood grain printed PVC sheet & edges will be painted to match printed sheet, etc complete all as specified. |
| 49 | S & F factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of M.S. frame shall be covered with heat moulded wood grain printed PVC 'C' chanel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of wood grain printed sheet & 5 mm thick x 15 mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10 mm x 10 mm (90 degree) , all as per specification & drawing all as specified and directed. |
| 50 | S & F Anodised aluminium frame for doors, windows, vetilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed. |
| 51 | M & L Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed |
| 52 | M & L Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 nos.) suitable handle (1 nos.) complete all as specified |
| 53 | S & F for Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) (A) Area not exceeding 1.00 sqm each |
| 54 | S & F for Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) (A) Area exceeding 1.00 sqm but not exceeding 2.00 sqm each |
| 55 | Supply and fix Stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified |
| 56 | Supply and fix in repairs Stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified. |
| 57 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads or any thickness or any description completed as specified and as directed |
| 58 | M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty/ wooden beads in square n exc 0.5 Sqm in each pane complete all as specified. |
| 59 | M&L for 4.8 mm thk sheet glass ordinary quality and glazing with oil putty/wooden beads/aluminium beads in square exc 0.5 Sqm in each panes complete all as specified. |
| 60 | Supply and fix 100 mm long medium weight, cold rolled mild steel, Butt hinges, complete all as specified. |
| 61 | Supply and fix 75 mm long medium weight, cold rolled mild steel, Butt hinges, complete all as specified. |
| 62 | Supply and fix 200mm long of Aluminium anodised, barrel tower bolts of extruded section complete all as specified . |
| 63 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section all as specified and directed |
| 64 | Supply and fix 150mm extruded aluminum alloy handles, cast type, anodized all as specified and directed |
| 65 | Supply and fix 100mm extruded aluminum alloy handles, cast type, anodized all as specified and directed |
| 66 | S & F for Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 300 mm etc complete all as spd and directed. |
| 67 | S & F in repairs Brass 4 levers Mortice lock, vertical type, size 100 mm completed all as specified and as directed. |
| 68 | S & F in repairs for 150 mm length of Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor completed all as specified and as directed. |
| 69 | S & F in repairs mild steel, chromium plated curtain rods with brackets, including fixing stops, rollers bracket etc with harrison rails completed all as specified and as directed. |
| 70 | S & F Anodised aluminium sanp grid frame work for false ceiling and hangers 6mm dai G.I (upto 100mm length) including adjesting level fixed to roof slabes by means of ceiling cleats made of G.I flat 40x3mm size of 60mm long and expansion hold fastners 12.5mm dia 40mm long completed all as specified and as directed. |
| 71 | Supply & fixing false ceiling with all heights with Semi perforated 12mm thick micro tegular edged GRS (Glass fibre reinforced Gypsum) false ceiling tiles of size 595 x596 mm of approved texture, design and petterns having moisture content less than 2% humidity resistance of 99% NRCO 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlockingmetal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drwings and as per directions of Engineer-in-Charge. Make: Everest Industries Ltd or equivalent as per IS 8225:1987 |
| 72 | S & F 4 mm thick Asbestos cement plain building boards, fixed to timber framework with screws and dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, etc complete all as specifed and directed. |
| 73 | S & F 4 mm thick Non Asbestos fibre cement plain building boards, fixed or laid/inserted to timber framework / GI/ Aluminium frame work with screws etc complete all as specifed and directed. |
| 74 | S & F 5 mm thick plain colour PVC Sheet in strips and channel feathered at edges for fixing on solid PVC Wall lining ,PVC Wall lining and solid PVC Partitions inclusive of solvents cement and fixing st site complete all as specified and directed |
| 75 | S & F for bitumen based water proofing tape reinforced flashing bitumious (UV resistant self adhesiv flasing Bituminous tape) with polyster film below aluminium film having 100 mm width and minimum thickness of 1.5mm laid on roof surfaces by forced application including cleaning of surfaces complete all as specified |
| 76 | S & F in repair for PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed |
| 77 | M & L for PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed |
| 78 | S & F in repair PVC water tank top cover for PVC tank 500/1000 ltr capacity and clip type bolt for locking arrangement for side opening as suitable on top cover for protection complete all as specified and directed by Engr-in-charge. |
| 79 | Supply and fix in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono crystalline solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed |
| 80 | M&L for preparation of old decorated surfaces of walls including cornices (plastered or unplastered) and applying two coats of white wash all as specified and as directed . |
| 81 | M&L for preparation of old decorated surfaces of ceiling including cornices (plastered or unplastered) and applying two coats of white wash all as specified and as directed. |
| 82 | M&L for preparation of new surfaces undecorated surfaces of ceiling including cornices (plastered or unplastered) and applying three coats of white wash all as specified and as directed. |
| 83 | Material and labour for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed. |
| 84 | M&L for preperation of old decorated surfaces of walls and applying two coat of cement based paint all as specified and directed. |
| 85 | Material and labour for preperation of old decorated surfaces of walls and applying two coats of cement based paint all as specified and directed. |
| 86 | M&L for complete removal of existing treatment finises and preparation of old decorated plastered wall surfaces and applying two coats of distemper oil emulsion over 1mm thick wall care putty on wall complete all as specified and as directed. |
| 87 | M&L for preparation of old decorated plastered wall surfaces and applying two coats of distemper oil emulsion all as specified and as directed. |
| 88 | Material and labour for preparation of old decorated plastered wall surfaces and applying two coats of oil bound distemper complete all as specified and as directed. |
| 89 | M&L for two coats synthetic enamel paint over a coat of red oxide on new iron surfaces of any description not otherwise described over 10 cm including preparation of new or previously untreated surface all as specified & directed. |
| 90 | Prepartation of old painted steel surfaces over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed. |
| 91 | Prepartation of old painted steel surfaces over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed. |
| 92 | Prepartation of old painted steel surfaces over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 93 | Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed. |
| 94 | Prepartation of old painted wooden surfaces over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 95 | Prepartation of old painted wooden surfaces over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 96 | Material and labour for preparation of old wooden base surfaces of any description over 10cm in width or girth and applying two coats of varnish all as specified and directed. |
| 97 | Writing letters of figures ( BLOCK, Roman, Italic or Indian) 5cm high all as specified and directed. |
| 98 | E & M Division items |
| 99 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 100 | M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 101 | M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One ceiling fan point controlled by one, one way switch 5 Amp. |
| 102 | M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One exhaust fan point controlled by one, one way switch 5 Amp. |
| 103 | M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 104 | M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 105 | M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One bell/ buzzer point controlled by one, one way switch 5 Amp. |
| 106 | M&L for point wiring with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 107 | S&F modular switch 1 way 6A/10A, 1 Module complete all as specified and directed. |
| 108 | S&F modular switch 1 way 16A/20A, 1 Module complete all as specified and directed. |
| 109 | S&F modular socket 6A/10A, 2/3 pin combined 2 module complete all as specified and directed. |
| 110 | S&F modular socket 16A/20A, 2/3 pin combined 2 module complete all as specified and directed. |
| 111 | S&F modular Bell push 6 Amp 1 module type all as specified and directed. |
| 112 | S&F ringing bell AC 230 volts single pole complete all as specified and directed. |
| 113 | S&F electronic fan regulator modular type stepped type (5 steps) 120W, 230V, 2 module, ISI marked duly connected up complete all as specified and directed |
| 114 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 115 | S&F modular metal flush box 3 module with white cover plate with frame ISI marked complete all as specified and directed |
| 116 | S&F modular metal flush box 4 module with white cover plate with frame ISI marked complete all as specified and directed |
| 117 | S&F modular metal flush box 6 module with white cover plate with frame ISI marked complete all as specified and directed |
| 118 | M&L for submain wiring with four run single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including heavy body PVC non metallic rigid Conduit concealed with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 6.0 sqmm PVC insulated FRLSH unsheathed multi strand copper conductor earth wire connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing incl taking out old existing submain wiring complete all as specified and directed. Note: Four run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 119 | M&L for submain wiring with two run single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit concealed with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated FRLSH unsheathed multi strand copper conductor earth wire connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing incl taking out old existing submain wiring complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 120 | Supply and fix LED tube light fitting of 20 watt, 230V, with polycarbonate housing enhances safety, high quality PC Diffuser, easy to install Efficiancy not less than 100 lumen/watt including taking down old one complete all as specified and directed. |
| 121 | Supply and fix LED tube light fitting of 10 watt, polycarbonate housing enhances safety, high quality PC Diffuser, easy to install Efficiancy not less than 100 lumen/watt including taking down old one complete complete all as specified and directed. |
| 122 | S & F new generation, energy saving environment friendly, long life LED Flood light 50/60 watt mae up of pressure die cast aluminium housing with high power LEDs and secondary lenses with IP 66 protection. System eficiancy > 110 LPW with 10kv built in surge protection device including dismantling old one complete all as specified and directed |
| 123 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type down lighter with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 124 | S & F sheet metal enclosure powder coated three pole and neutral (TPN) DB for fixing of MCBs, 4 way double door with copper bus bar 200 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces incl taking down old one complete all as specified and directed. |
| 125 | S & F sheet metal enclosure powder coated single pole and neutral (SPN) DB for fixing of MCBs, 12 way double door with copper bus bar 200 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces incl taking down old one complete all as specified and directed. |
| 126 | S & F sheet metal enclosure powder coated single pole and neutral (SPN) DB for fixing of MCBs, 8 way double door with copper bus bar 200 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces incl taking down old one complete all as specified and directed. |
| 127 | S & F sheet metal enclosure powder coated single pole (SP) DB for fixing of MCBs, 4 way double door with copper bus bar 200 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces incl taking down old one complete all as specified and directed. |
| 128 | S & F MCB TPN of capacity 40-100 Amps , 240 V, 10 KA 'B' curve incl taking down old one complete all as specified and directed. |
| 129 | S & F MCB SPN of capacity 32 Amps, 240 V, 10 KA 'C' curve incl taking down old one complete all as specified and directed. |
| 130 | S & F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'B' curve incl taking down old one complete all as specified and directed. |
| 131 | M & L for new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with The earthing includes PCC Type B1 Pit chamber, RCC Type B1 pit cover and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 132 | Taking down fan, any size any make from various satellite area locations, for repair/replacement of defective parts and rehanging/refixing in its original location after reconditioning complete as specified and directed for Ceiling fan of size 1200/1400 mm sweep, wall fan/Exhaust fan upto 450mm sweep. Note:- Spare Items for reconditioning will be measured and paid separately under respective items of BOQ. |
| 133 | Material and labour for Painting of ceiling fans complete, in- situ with one coat synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc complete all as specified and directed. |
| 134 | Material and labour for Painting of exhaust fans upto 450mm sweep complete, in-situ with one coat synthetic enamel paint by spraying including filling cavities with filler, cleaning all dust etc complete all as specified and directed. |
| 135 | M&L for removing the burnt out winding, cleaning slots, rewinding the motor with super enamelled copper wire of equivalent size to the original winding including warnishing, drying etc replacement of body screws, testing and commissioning on full load for 8 hours continous running for Ceiling fan 1200/1400mm sweep complete. |
| 136 | M&L for removing the burnt out winding, cleaning slots, rewinding the motor with super enamelled copper wire of equivalent size to the original winding including warnishing, drying etc replacement of body screws, testing and commissioning on full load for 8 hours continous runing for exhaust fan upto 450mm sweep complete. |
| 137 | Supply in replacement, capacitor 2.5/3.15 MFD , 240 volts, AC suitable for fans etc complete all as specified and directed. |
| 138 | Supply in replacement, ball bearing made out of high carbon steel as per existing suitable for Ceiling fan any type any size complete all as specified and directed. |
| 139 | Supply in replacement, bush bearing made out of brass alloy as per existing suitable for Ceiling fan any type any size complete all as specified and directed. |
| 140 | Supply in replacement, down rod upto 1.20 mtr length made of 15mm dia GI Tubing duly painted suitable for Ceiling fan any type any size including nut, bolt, splitpin made out of nickle plated mild steel with rubber reel insulator including dismantling old one complete all as specified and directed. |
| 141 | Supply in replacement, PVC flexible twisted twin core cable with multistranded copper conductor of size 23/0.0076 (0.50 sqmm) 1100 volts grade complete all as specified and directed. |
| 142 | Taking down deffective geyser of capacity upto 25 ltrs of any make from its existing position after disconnecting inlet/outlet water connection and opening of geyser for checking and repairing the deffective parts, including testing the same after repairing, refixing the same on its original position and making all connections complete all as specified and directed. |
| 143 | Supply in replacement heating element 1.5/2.0 KW, 240 volts, AC any type with heat resistant rubber washer complete all as specified and directed. |
| 144 | Supply in replacement fusible plug with inernal or external threading uitable for suitable for 25/15 ltrs capacity geysers any type complete all as specified and directed. |
| 145 | Supply in replacement non return valve made out of brass size 15mm bore complete all as specified and directed. |
| 146 | M & L for Painting of geysers complete, in-situ with one coat synthetic enamel paint by spray method including filling cavities with filler after cleaning all dust etc complete all as specified and directed. |
| 147 | M&L for making four Nos holes in wall grouting 4 nos rag bolts of size 125mm long x 12 mm dia with PCC including necessary nuts and washers for 25/15 ltrs cap of geysers on wall complete all as specified and directed. |
| 148 | M&L for filling the glass wool between outer cover and inner tank of geysers 15/25 ltrs capacity including taking out old one complete all as specified and directed. |
| 149 | S&F metallic outer cover including bottom and top cover duly spray painted with 2 coats of synthetic enamel paint over a coat of redoxide chromate primer suitable for any type of geyser for 15/25 ltrs capacity complete all as specified and directed. |
| 150 | Supply in replacement, inner tank made out of copper alloy, suitable for any type of geysers of 15/25 Itr capacity, made out of brass 15/20 mm bore complete all as specified and directed. |
| 151 | Supply in replacement, pressure/air release valve suitable to fix in inlet of geyser complete all as specified and directed. |
| 152 | Supply in replacement, thermostat unit hot/cold suitable for Geyser upto 25 Ltr capacity complete all as specified and directed. |
| 153 | S&F in repair low density polyethylene (LDPE) Pipe 16 mm dia, 450 mm long suitabe for hot/cold water application with brass union on both sides to suit 15 mm bore GI/CPVC pipe including taking down old one complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail