| 1 | (A) HAVC Work:-MR-1: Suypplying with fitting fixing of Inverter type Air cooled ceiling suspended type ductable air conditioning units (IDUs) & ODUs). The unit shall he complete with ductable fan coil unit and external unit consider4ing unit cooling thermostate complete in all respects. The Rehigerant shall be R401A as required and directed by the department.(a) 8.5 TR Ductable Units. |
| 2 | (b) 11.0 TR Ductable Units |
| 3 | (c) 22.0 TR Ductable Units |
| 4 | MR-2: Supplying with fitting fixing of Inverter type Air Cooled ceiling suspended type ductable air conditioning units (IDUs & ODUs). The unit shall he complete with ductable fan coil nunit and external unit condensing unit and cooling thermostat complete in all respect. The Rehigerant shall be R410A asrequired and directed by the department.(a) 1.5 TR Hi-Wall Units. |
| 5 | (b) 2.0 TR Hi-Wall Units. |
| 6 | MR-3: Supply & Installation, Testing, Gas charging and Commissioning of Indoor Units & Outdoor Units with other accessories complete as required and directed by the department. Inverter Ductable Airconditioners (Make:- Blue Star)(a) 8.5 TR Ductable Units |
| 7 | (b) 11.0 TR Ductable Units |
| 8 | (c) 22.0 TR Ductable Units |
| 9 | MR-4: Supply & Installation, Testing, Gas charging and Commissioning of Indoor Units & Outdoor Units with other accessories complete as required and directed by the department. (a) 1.5 TR Hi-Wall Units |
| 10 | (b) 2.0 TR Hi-Wall Units |
| 11 | (c) Supply of R-410 A Gas |
| 12 | MR-5: Refrigerant piping along with insulation and supports, between indoor & outdoor units duly insulated as per specifications. All piping inside the room shall be properly supported with hanger and exposed piping shall be properly supported etc. as required and directed by the department.(a) 12.7 mm dia (13 mm thick) |
| 13 | (b) 28,6 mm dia (19 mm thick) |
| 14 | MR-6: Providing and fixing shielded control cabling (copper) between indoor, outdoor, remote controller as per specifications. Shielded copntrol wiring shall run in 25mm Heavy Duty Condult etc. as required and as directed by the department.(a) Control Cable (7C X 2.5 Sq.mm) for Ductabel units. |
| 15 | MR-7: Providing and fixing regid UPVC piping complete with fittings, and connected to nearest floor trap as per specifications and duly insulated with 6 mm thick closed cell insulation etc. as required and as directed by the department.(a) UPVC 32 mm dia |
| 16 | MR-8: Supply, Installation and testing of Factory fabricated GI sheet metal ducts as pri SMACNA in accordance with the approved shop, drawings. (120gm/rine coating), etc. as required and as directed by the department.(a) 24 Gauge |
| 17 | (b) 22 Gauge |
| 18 | MR-9: Supply, fabrication, installation and testing the flexible Canvas connections constructed of fire resistance double resin sleeves as per the approved shop drawings etc. as required and as directed by the department. |
| 19 | MR-10: Supply, Installation, testing aid balancingof Powder coated extruded aluminium construction Supply air grille with (VCD). Sqm. Removable core & antismudge ring etc. as directed by the department. |
| 20 | MR-11: Supply, Installation, testing aid balancing of Powder coated extruded aluminium construction Return air grille without (VCD). Sqm. Removable core & antismudge ring etc. as directed by the department. |
| 21 | MR-12: Supplying and fixing of following thickness acoustic insulation material shall be Nitrile Rubber open cell foam. Density of the nitrile ubber shall be 140-180 Kg/m3. It should have antimicrobial product protection, and should pass Fungle Resistance and thickness should be 15 mm thick acoustic lining etc. as required and as directed by the department. |
| 22 | MR-13: Supplying and fixing of following thickness duly laminated aluminium foil of mate finish closed cell Nitrile Rubber Insulation on existing duct after applying suitable adhesivge for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete etc.. as required and as directed by the department. |
| 23 | (B) Fire Fighting:18.4: (A) Supplying installation, testing and commissioning of electric driven terrace pump suitable fdor automatic operation and consisting of following complete in all respects as required (Terrace Pump)18.4.1. Terrace Pump 900LMP at 35m head |
| 24 | 18.7: Providing laying, testing & commissioning of 'C' class (Medium) MS pipe conforming to IS 3589/ IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint after primer coat of required shade, cutting hole and chase in brick wall/ RCC slab and making good the same etc. complete as required. (Make: TATA, JINDAL, NEZONE)18.7.1 25 mm. dia |
| 25 | 18.7.2 32 mm. dia |
| 26 | 18.7.3 40 mm. dia |
| 27 | 18.7.4 50 mm. dia |
| 28 | 18.7.5 65 mm. dia |
| 29 | 18.7.6 80 mm. dia |
| 30 | 18.11: Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. MAKE: KARTAR, AUDCO, SANT18.11.2 50 mm. dia |
| 31 | 18.11.3 65 mm. dia |
| 32 | 18.11.4 80 mm. dia |
| 33 | 18.14: Providing, installing, testing and commissioning of non-return valve, PN 1.6 of following sizes conforming to IS:5312 complete with rubber gaskes, GI bolts, nuts, washers etc as required. MAKE: KARTAR, AUDCO, SANT18.14.4 80 mm. dia |
| 34 | 18.21: Providing, installing, testing and commissioning of 15 mm. dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories. MAKE: GETECH/DEFENCE AGNI/ ELITECH/ ASES18.21.1 Pendent Sprinkler |
| 35 | 18.21.2 Upright Sprinkler |
| 36 | 18.21.3 Horizontal Side Wall Sprinkler |
| 37 | 18.24: Providing, Fixing, Testing and Commissioning of Sprinkler Installationm Control Valve of Cast iron body and brass/ bronze working parts comprising of water motor, alarm, bronze seat clapper aned clapper arm asnd hydraulically driven mechanical gong bell to sound continous alarm when the Sprinkler system activates, pressure gauges, emergency releases, strainer, pressureswitch, cock valve complete with drain valve and by pass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 100 mm dia, as required. MAKE: GETECH/DEFENCE AGNI/ ELITECH/ ASES18.24.2 100 mm dia |
| 38 | 18.25: Supplying: installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stock bar of following sizes complete as required.18.25.2 Sprinkler Flexable Pipe 1000mm |
| 39 | 18.25.3 Sprinkler Flexable Pipe 1200mm |
| 40 | 18.25.3 Sprinkler Flexable Pipe 1500mm |
| 41 | 18.29: Provieding, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL listed or FM approved complete as required. |
| 42 | (C) Fire Detection & Fire Alarm:1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.9. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 43 | 1.21: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.1.21.1 20 mm |
| 44 | 17.2.1: Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire aslarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop lenght up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit ( 230 + 5 % V, 50hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer ti prinout log and faility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per required.17.2.1.2 Two Loop Panel. |
| 45 | 17.2.2: Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 46 | 17.2.3: Supplying, installation, testing & commissioning ofd repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 47 | 17.2.4: Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 48 | 17.2.5: Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. as required. |
| 49 | 17.2.6: Supplying, installation, testing & commissioning of intelligent addressable programmmable sounder complete as required. |
| 50 | 17.2.9: Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. |
| 51 | 17.2.13: Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required. |
| 52 | 17.2.14: Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 53 | 17.2.19: Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 54 | 17.3.3: Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling, 3/1.5 Watt in ABS enclosure complete as required. |
| 55 | 17.3.4: Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required. |
| 56 | 17.3.8: Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. |
| 57 | 17.5.2: Supplying & laying of 2X1.5 sqm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 58 | NS-1: Supplying, installation, testing & commissioning of Powder based Fire Extinguiser capacity 6 Kg Store Pressure Firechem make or equivalent as approved by the Deptt. |
| 59 | NS-2: Supplying, installation, testing & commissioning of 9 Kg BG Cartride type mportable Fire Extinguiser Finish Fire make or equivalent as approved by the Deptt. |
| 60 | NS-3: Supplying, installation, testing & commissioning of Orion Make 1 KVA Online UPS with 60 minutes battery backup (2-2) 1600 VAH. Please Enable Macros to View BoQ information |