| 1 | Construction works |
| 2 | Complete clearing and grubbing of the construction site, including removal of all existing vegetation and debris. Segregation and off-site relocation of all old substation equipment and vehicles (e.g., ground wires, cables, angles, hydra-crane, tractors) to a designated area outside the construction zone. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil |
| 4 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | One Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Centering and shuttering including strutting, propping etc. and removalof form work for :4.3.1 Foundations, footings, bases for columns |
| 7 | 4.3.3 Columns, piers, abutments, pillars, posts and struts |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources) |
| 11 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :21.1.1.2 Powder coated aluminium (minimumthickness of powder coating 50 micron) |
| 12 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.1 With float glass panes of 4.0 mm thickness (weight notless than 10kg/sqm) |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 14 | 15 mm cement plaster on the rough side of single or half brick wall ofmix :13.2.1 1:4 (1 cement: 4 fine sand)Outside & Inside |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)For Outside |
| 16 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :13.41.1 New work (two or more coats) over and including waterthinnable priming coat with cement primerFor Inside |
| 17 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 18 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 19 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.3 0.45/0.50 mm thick with zinc coating not less than 275 gm/ m² |
| 20 | Providing ridges or hips of width 60 cm overall width plain G.S. sheetfixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete.12.4.2 0.45/0.50 mm thick with zinc coating not less than 275 gm/m² |
| 21 | Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. Complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
| 22 | Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt.1.1.1.) Medium point up to 6.00 metre. length. |
| 23 | Supplying with fitting and fixing SPN 10KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.16.2.1 B series (Schneider MG, Legrand, Hager, Crabtree Xpro make)16.2.1.1 6 to 32A |
| 24 | Supplying fitting and fixing indusrial Plug & socket in surface mounting TPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of 4P MCB complete with making necessary connection etc. As specified and directed by the Deptt.13.2.1 (ABB, Schneider MG, Legrand, Hager make)13.2.1.2 30/32A Capacity Please Enable Macros to View BoQ information |