| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch modular plates suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.;(a) Group A -- with Cat A Modular Accessories |
| 2 | Wiring for 5A /15A power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for 5A /15A power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(d) 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm Conduit) |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 9 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(a) Cat A |
| 10 | Supplying and fixing brass batten/ angle holder including connections etc as required. |
| 11 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(a) 1 or 2 Module Cat A |
| 12 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(a) Cat A |
| 13 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. |
| 14 | Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity modular plate and cover including connection painting etc. as required.;(a) Cat A |
| 15 | Supplying and fixing 20 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alon with 20 A C series SP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required\\";(a) Cat A\\" |
| 16 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB fabricated out of 16 SWG sheet steel powder coated complete as required and conforming to the requirements of Goa Electricity Department. |
| 17 | Supply installation testing and commissioning of electronic type three phase energy meter (KWh) 4 wire ISI marked in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display with ELT in Class 1.0 50 Hz 240 V. AC duly tested by MRT along with Test Certificates complete as required of following capacity of make L & T only.;(b) 10 to 40 A |
| 18 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(a) 4 way single door Cat A |
| 19 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(g) 12 way double door Cat A |
| 20 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(m) 4 way double door Cat B |
| 21 | Supplying and fixing following rating three pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(a) 40 A Cat A |
| 22 | Supplying and fixing following rating double pole 240 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(a) 40 A Cat A |
| 23 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 24 | Supplying and fixing 40 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(d) TP Cat A |
| 25 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI markof approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(b) In rocky strata |
| 26 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop arthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 27 | Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 2.5 sq.mm |
| 28 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required |
| 29 | Supply and erecting fan hook box ( 100 mm diameter or equivalent square size 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box including painting with 2 coats of red oxide complete as required. Please Enable Macros to View BoQ information |