| 1 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 2 | Providing and laying 6mm precast white glazed tiles in walls over 12 mm cement mortar (1:3) and jointed with grey cement slurry flish pointed .. Do do all as per specifiction and E/I. |
| 3 | providing two coats of dry distemper of approved shade and make over a primer coat of washing over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper ,applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction E/I. |
| 4 | Providing one coat of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding , curing and taxes all complete as per building specification and direction of E/I. |
| 5 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 6 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a)Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick).The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc |
| 7 | Supplying, fitting and fixing good quality, well dressed and well seasoned local wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 8 | Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 9 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge.16.91.2 80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern. |
| 10 | Providing P.C.C.M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 11 | Supplying, fitting and foxing 40mm high vitreous while glazed earthen E.W.C. with 'p' trap of pany hindustan or any other approved 1.5.5. make including supplying and fixing 15 litres C.L. mosquito proof low down flushing cistem of approved make with complete fittings with C.Lhandle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other L.S.S. make with hinges or screws etc. painting pipe and cistern etc, with 2 coats of approved paint over a coat of red oxde iming, all complete as per specification and direction of EI. |
| 12 | 10 LT PVC CISTERN |
| 13 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of pany or Hindustan or any other LS.S. approved make supported on painted C.I. or R.S. brackets 32mm C.l.brass waste, 15 mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C, waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of EI |
| 14 | Providing and foxing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials withhap fittings of approved quality and colour weighing not less than 105 gms. |
| 15 | Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 16 | Providing and fixing CP: brass bib cock of approved quality confirming to IS 5931 |
| 17 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 18 | Glass shelf 600MM X 125 MM |
| 19 | Mirrors of 6 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirror |
| 20 | Polythene water storage tank o fmark with cover and suitable dod od all as per specification |
| 21 | Schedule items -Internal Electrical Work- (PART A) |
| 22 | Point Re -wiring in existing conduit :- |
| 23 | ReWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 24 | Group c |
| 25 | Power Plug Wiring in PVC conduit (2x4 sq. mm):- |
| 26 | Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 27 | Circuit / Sub-main wiring in PVC Conduit:- |
| 28 | Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 29 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 30 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 31 | Tv cable in existing conduit |
| 32 | Supplying and drawing co-axial cable RG -6 grand 0.7mm soild copper conductor PE insulated ,sheided with fine tinned copper braid and protected with P.V.C do.. Do all as per specification and E/I. |
| 33 | S/F Modular type Switch / Socket:- |
| 34 | Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. |
| 35 | 5/6 amps,one way switch |
| 36 | 15/16 amps,one way switch |
| 37 | 5/6 3 pin socket outlet |
| 38 | 5/16 6 pin socket outlet |
| 39 | TV antena socket outlet |
| 40 | S/F Modular type electronic fan regulator: Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 41 | supplying and fixing brass batten/angle holder including connection etc as required. |
| 42 | Supplying and fixing ding dong sound call bell single phase ,230 volts complete as per required. |
| 43 | ITC fluorescent fitting directly on surface :- |
| 44 | installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper cond. |
| 45 | S/F S.P. MCB DB:- |
| 46 | Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). Make :- Legrand/Schneider/ Siemens. |
| 47 | 6way (4+18),double horizontal type |
| 48 | S/F 'C' series SP MCB:- |
| 49 | Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make- Legrand/Schneider/ Siemens. |
| 50 | 6/32A Single Pole |
| 51 | 6/32A TPN |
| 52 | Providing and fixing M.V danger Board 200mm x 150 mm of made mild steel do do all as per specification |
| 53 | Earthing with G.I earth plate 600 mm x 600 mm x 6mm thick including accessories and providing do do all as per specification. |
| 54 | Supplying installation testing and commisionig of following size ceiling fan 3 blades confirming to IS 374:2019 DO..Do all asper specfication |
| 55 | SITC of floowing rating surface mounted do..do all as per specification |
| 56 | ( 10/12 w led tube light) |
| 57 | 20/22 W LED Tube light |
| 58 | Supply and instalation of all in one hybrid solar street light including 6mtr.Height Octagonal pole |
| 59 | Providing ,storing,handling,shifting,installation,testing and commissioning of portable fire extinguisher as described below |
| 60 | 4.5 kg carbon dioxide extinguisher IS marked with high pressure discharge tube ,horn,contro valve ,CCE approved cylinder |
| 61 | 6kg mono ammonium phosphate (ABC) type Catridge operated extinguisher |
| 62 | : Cost of drilling 200mmX165mmX125 Mtr deep bore well in all kinds of soil and rock in rural area for installation of pump bore set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site. |
| 63 | (a) 0.00m Up to 50.00m depth below G.L. In Rural Areas |
| 64 | (b) Above 50.00 m depth. In Rural Areas |
| 65 | Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc. all complete job. (DWSD Item 120) |
| 66 | Supplying all materials, labour, tools & equipments for fitting & fixing 200mm dia MS cap over casing pipe complete job. (DWSD Item 120 B) |
| 67 | Supplying materials and labours for constructing bore well chamber of 75B designation brick masonry chamber 600mmx450mm and 750mm deep internal dimension having 250mm thickness in cement mortar 1:6 including 12mm cement plaster 1:6 with 600mmx475mm RCC cover with earth work in excavation and 75mm thick PCC(1:3:6) in foundation and refilling all complete as per specification and direction of E/I (Annexure I Attached) (As per Old Model Estimate) |
| 68 | Supplying 2 HP submersible mtor pump 150mm (with bronze impeller upto 8 stages) |
| 69 | Supplying XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Three core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. (3 core 2.5 sqr mtr.) |
| 70 | Cost of control panel board consisting of main switch, dry run protector(0-150amp) amper meter0.500V) voltmeter, indicator lamps, internal writing with PVC insulated seethed copper wire etc all complete |
| 71 | Providing & fitting of 32mm dia UPVC sch-80 column pipe etc all complete |
| 72 | Providing & fitting of 32mm dia UPVC sch-80 etc all complete |
| 73 | Providing & fitting of 32mm dia NR vulve (H) ISI mark |
| 74 | Providing & fitting of M.S. Clamp with nut & bolt to hold the column pipe mark |
| 75 | Providing 0.5 dia PVC string to hold the pump set firmly |
| 76 | Cost of lowering installation & commissioning starter etc all complete job |
| 77 | Providing of G.I. Fittings all complete |
| 78 | 32mm dia Elbow |
| 79 | 32mm dia socket |
| 80 | 32mm dia Union |
| 81 | 32mm dia Jam Nut |
| 82 | 32mm dia Nipple |
| 83 | Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I. 32mm dia and weight not less than 700gms |
| 84 | Earth work in excavation (As per I.S. 3114/1965 for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineerin-Charge. For classification of Soil item - B (50.00x0.30x0.30) |
| 85 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineerin-Charge |
| 86 | Supplying materials , labours and equipments for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I. |
| 87 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 88 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 89 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio). Multiplying Factor-2.0 (for painting all over) |
| 90 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. Multiplying Factor-2.0 (for painting all over) |
| 91 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete |
| 92 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 93 | Carriage of Materials |
| 94 | Cement Lead 3 KM |
| 95 | Chips Lead 15 KM |
| 96 | Paver 8 KM |
| 97 | Add GST 18% |
| 98 | Add Labourcess 1% Please Enable Macros to View BoQ information |