| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means i foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm onplan),including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil. DSR No. 2.8.1 |
| 2 | Suppluing and filling in plinth with with sand under floors,including watering,and ramming cobnsolidating and dressing complete. DSR NO. CH Material 983 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR No.. 4.1.8 |
| 4 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts buttresses,string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).DSR No.4.2.2 |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. SI No. Ch. 5.22.6 |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts DSR No.5.9.6 |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand).DSR-6.1.2 |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.4.1 |
| 9 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) including cost of all material, labour, T&P etc. required for proper completion of work.DSR No.13.4.1 |
| 10 | 12 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) including cost of all material, labour, T&P etc. required for proper completion of work. DSR No.13.4.2 |
| 11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR-13.80 |
| 12 | Distempering with 1st quality acrylic distemper, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.New work (Two or more coats applied @ 3.84 kg/10 sqm). DSR- 13.41.1 |
| 13 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. DSR 12.41.2 |
| 14 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineerin- Charge. DSR 22.22A |
| 15 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.DSR -11.3.1 |
| 16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm. DSR 11.41.2 |
| 17 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 9.21.2 |
| 18 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). DRS No. 9.23 |
| 19 | Providing and fixing bright finished brass tower bolts (barrel type) withnecessary screws etc. complete :200x10 mm DSR 9.74.2 |
| 20 | Providing and fixing bright finished brass door latch with necessary screwsetc. complete :300x16x5 mm DSR 9.75.1 |
| 21 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : (copper oxidized as per IS: 1378) 300x16 mm DSR 9.62.1 |
| 22 | Providing and fixing bright finished brass handles with screws etc.complete: 125 mm DSR 9.81.1 each |
| 23 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete DSR 9.82 |
| 24 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. DSR 9.83 |
| 25 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR 10.31 |
| 26 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications.Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture DSR- 13.48.3 |
| 27 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. as per SI no-10.28 |
| 28 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement as per SI No-11.20.1 |
| 29 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- II) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. DSR 4.17 |
| 30 | Rewiring point for fan/fresh air with 1.5 Sqmm FRLSH PVC insulated multistand single core copper conducter cable in PVC conduit pipe concealed in the wall complete with 1.5 Sqmm FRLSH PVC insulated multistrand Single core copper conductor cable as earth wiere drawn inside the conduit add for modular type switch in place of piano type switch SI No.133C+187A |
| 31 | Rewiring point for fan/fresh air with 1.5 Sqmm FRLSH PVC insulated multistand single core copper conducter cable in PVC conduit pipe concealed in the wall complete with 1.5 Sqmm FRLSH PVC insulated multistrand Single core copper conductor cable as earth wiere drawn inside the conduit add for modular type switch in place of piano type switch SI No.133C+187A |
| 32 | S/f of Power Plug with 20 amp/250 volt flush type mudular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed MS Box including supply of all material labour T&P etc. requaired for proper completion of work SI No.1139 A |
| 33 | Supply and fixing of shead steel enclosure surface/ flush mounting fitting with 20 AMP 2 Pin and earth metal clad scraping earth plug and socket complete in all respect with MCB 32 AMP CAT-A SI No.1031+1002 A |
| 34 | Supply and fixing of LED Tube light with batten suitable for up to 1 x 22 W LED tube light complete including tube etc. on surface complete in all respact CAT-AA SI No1413 CAT AA |
| 35 | Supply and fixing of 36 to 46 watt indore recess mounting LED square fitting for armstrong ceiling having power coated diecast aluminium housing body with extended heat sink, diffuser of special poly carbonarte material and driver set complete in all respact CAT-AA SI No.1406 AA |
| 36 | Supply and fixing of Ceiling fan of ISI mark complete in all respact including all material, labour & T&P etc. complete. SI No. 1501(I) |
| 37 | Supply and fixing of fresh air fan of ISI mark complete in all respact including all material, labour & T&P etc. complete. |
| 38 | Supply and wiring of submain with 2 No. 4 Sqmm FRLSH PVC insulated 1100 volt grase multistand single core copper conducter cable in 20 mm dia heavy duty PVC conduit with 01 no. 2.5 Sqmm FRLSH PVC 1100 volt grase multistand single core copper conducter as earth wire drawn inside the conduit add for modular type switch in place of piano type switch SI No. 216C |
| 39 | Supply and wiring of submain with 2 No. 4 Sqmm FRLSH PVC insulated 1100 volt grase multistand single core copper conducter cable in 20 mm dia heavy duty PVC conduit with 01 no. 2.5 Sqmm FRLSH PVC 1100 volt grase multistand single core copper conducter as earth wire drawn inside the conduit add for modular type switch in place of piano type switch SI No. 216C Please Enable Macros to View BoQ information |