Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | E- Type Ground FloorEarth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lift. complete as directed by the E.I.C.(As Per AR Page No.-1, Item No.-1) |
| 2 | Supplying & filling of foundation with course sand well watered and rammed including cost, cost of all labour, carriage, royalty complete in all respect. (As Per A/R Page No-1, Item No-2) |
| 3 | P.C.C(1:3:6) using 40mm size hard granite C.B. metal approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C. |
| 4 | Providing Cement Concrete (1:2:4) in levelling course using 12 mm size hand broken granites chips.including watering,curing ,all cost,conveyance,roality etc.complete as per the specifiction and direction of Engineer-in- charge |
| 5 | R.C.C. M-25 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement.A)COLOUM BASE FOOTING |
| 6 | B)COLUMN SUPER STRUCTURE |
| 7 | C) PLINTH BAND |
| 8 | D) LINTEL BAND |
| 9 | E)FLOOR BEAM |
| 10 | F) CHAJJA |
| 11 | G) Staircase |
| 12 | H) ROOF SLAB |
| 13 | Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect. |
| 14 | Brick work with Flyash Bricks 25cm x 12cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Foundation and Plinth including watering curing, cost of carriage, royalty and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 15 | Brick work with Flyash Bricks 25cm x 12cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Super Structure including watering curing, cost of carriage, royalty and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 16 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 17 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 18 | 6 mm thick C.P. (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment , watering, curing cost, carriage & royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ref(A/R-2006,P-103,Item no-27) |
| 19 | Supplying, fitting and fixing vitrified tile (Plain) in floors of size 600mm x 600mm of approved make conformaing to IS : 13755 laid on 20 mm thick cement mortar (1:4) (1 cement :4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the worl all complete as per direction of E.I.C. (For New work only) (Johnson/Kalaria/somany/RAK) |
| 20 | Fixing tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete.(Johnson/Kalaria/somany/RAK) |
| 21 | Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete. |
| 22 | Finishing wall surface with Cement based wall putty (water based) of approved make and finished smooth & even surface to receive painting including cost of scaffolding etc. with cost of all materials, labour etc. complete. |
| 23 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete. |
| 24 | Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. |
| 25 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. G |
| 26 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. W |
| 27 | Supplying fitteng and fixing of stainless teel of 304 in hand railing using 50mm dia of 2 mm thick circular pipe with balustrade of size 32mmx32mmx2mm @0.90 mtr C/C and stainless aquare pipe bracing of sixe case as per approved design and specification buffing polishing etc with the cost conveyance taxses of all material cost of all labour etc complete in all respect |
| 28 | Supplying fitting & fixing of 32mm thick flush door shutters with flush door block board 'A' premium 32mm thick both side teak (Green ply / Allwin) both side laminated with 4 mm thick veener board (Teak Heritage) (Archid ply/ Green ply ) by using adhesives, with all labour, iron fitting & wooden hinged cleats etc. fitted & fixed complete in all respect, including cost of iron fitting , alluminum fittings, all labours, T&P etc. as per specification approved by the Department & as per direction of the E.I.C. |
| 29 | Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154, 151-155, as windows frame section No. 151- 155, 151-153 and 151-167 as shutter framewith 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting includingcost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge. |
| 30 | Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primmer & labour to give an even shade excluding cost of primer. (As per A.R. 93/1) |
| 31 | Painting two coats with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. |
| 32 | E type Head RoomR.C.C. M-25 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement.A)COLOUM SUPER STRUCTUR |
| 33 | E)FLOOR BEAM |
| 34 | H) ROOF SLAB |
| 35 | Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect. |
| 36 | Brick work with Flyash Bricks 25cm x 12cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Super Structure including watering curing, cost of carriage, royalty and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 37 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 38 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
| 39 | 6 mm thick C.P. (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment , watering, curing cost, carriage & royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ref(A/R-2006,P-103,Item no-27) |
| 40 | Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete.12 MM CP |
| 41 | 16 mm CP |
| 42 | Finishing wall surface with Cement based wall putty (water based) of approved make and finished smooth & even surface to receive painting including cost of scaffolding etc. with cost of all materials, labour etc. complete. |
| 43 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete. |
| 44 | Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. |
| 45 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. |
| 46 | Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primmer & labour to give an even shade excluding cost of primer. (As per A.R. 93/1) |
| 47 | Painting two coats with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. |
| 48 | 25mm thick CC 1:2:2 with 6mm size CB chips for grading concret over froof slab etc complete |
| 49 | E.IRecessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) -do- Group A |
| 50 | -do- Group B |
| 51 | -do- Group C |
| 52 | Recessed wiring to Fan Point in... -do- Group B |
| 53 | Recessed wiring to Call Bell Point in... -do- Group C |
| 54 | Recessed wiring to Exhaust Fan Point in -do- Group B |
| 55 | S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof. |
| 56 | S/F of Angle holder replacing Ceilling Rose |
| 57 | Swich BoardsS/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board |
| 58 | S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp modular switch, connection, painting etc as required. |
| 59 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. Modular switch & Socket, connection, painting etc as required |
| 60 | S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover. |
| 61 | S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection |
| 62 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover |
| 63 | 6 Modular box with base & cover |
| 64 | 8 Modular box with base & cover |
| 65 | Sub-MainWiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.5 (1.8.1) |
| 66 | 2x2.5+1x1.5 (1.8.2) |
| 67 | 2x4+1x1.5 (1.8.3) |
| 68 | 2x6+1x2.5 (1.8.4) |
| 69 | Inverter wiring (1x2.5smm) Copper wire (1.19.11a) |
| 70 | Circuit BreakersS/F of 'C' series SP MCB of 10 to 32A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 71 | S/F of 'C' series DP MCB of 16Amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 72 | S/F of 'C' series DP MCB of 63Amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 73 | Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make : Legrand / Hager / Scheider / Seimens)S/F of MCB 12 way Double door (Analysis attached) |
| 74 | Main SwitchesSupply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) S/F of 63A ICDP main switch with MS box of 250mmx300mmx60mm deep ( (2.15A)+(1.24.16 ) |
| 75 | Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2) |
| 76 | Supply & laying 6 SWG Cu wire in recess for loop earthing as required |
| 77 | FittingSupply and fixing of 300mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 12\\" reversiable /Havells-Venti Air DS (HS)/Anchor- Anmol delus R/Orient-Power Flow DBB// Pollycab -Fresh on DBB ) |
| 78 | Supply and fixing of 230mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 12\\" reversiable /Havells-Venti Air DS (HS)/Anchor/Orient/ Pollycab ) |
| 79 | S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30) |
| 80 | Swich BoardsS/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections ( Make- Crompton/Phillips/HPL/Polycab/Havells / Panasonic ) |
| 81 | Supply and fixing of 1200mm A.C. Ceiling fan (5 star) 28 watt BLDC with all accessories and connections with out fan regulator (Make:Usha-Techinix ISI /Crompton- Energion Groove/Havells-Efficiencia Neo/ Anchor- Eco Breeze Urban/Orient-Eco Tech Supreme/ Pollycab -Affeciente Neo ) |
| 82 | S/F step type modular fan regulator |
| 83 | Supply and fixing of 400 mm wall fan with all accessories and connections (Make:Usha-Maxx Air Ultra /Crompton- WM Hiflow wave /Havells-Accelro(HS)/Anchor- Altrix HS- OWH /Orient-Wall 43/ Great White - WYNO WF/ Pollycab -Aery HS ) |
| 84 | Supply and fixing of 60 Watt, IP66 Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections ( Make- Crompton/Phillips/HPL/Polycab/Havells / Panasonic ) |
| 85 | S/F of 10w Watt LED Bulb ( Make- Crompton/Phillips/HPL/Polycab/Havells / Panasonic ) |
| 86 | S/F of 15A socket on 2Modular Board board for A.C |
| 87 | S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand) |
| 88 | Area LightingsSupply 40 W AIO Solar street lights having 125 Wp or more highly efficient Monocrystalline PV module & 12.8 V 48 Ah or more ) Lithium Ferrophosphate (LiFePo4) Battery having BIS ) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), MPPT charge controller having > 92% efficiency & PIR Sensor. The initial lumen output of AIO street light shall be > 7200 lumen or more in CCT 6000K (+/-500K) (Lumen efficacy of 180 lm/w ) as per LM 79 report of NABL Lab . The LED chip will be of OSRAM/NISCHIA/CREE/SEOUL Semiconductor only and should be with lenses for effective lighting distribution. The complete system & BMS should be designed to provide 2 days (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 66 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. Warranty on the AIO street lights must be 5 years . The following test reports/certifications must be submitted for the technical acceptance of the products .1. LM 79 REPORT NABL lab ) , 2. IK 08 (Report of NABL lab ), 3. IP 66 Report of NABL lab |
| 89 | Supply of 7 mtr long hot dip galvanized Octagonal pole having base dia of 175 mm and top dia of 70 mm and plate thickness of 4 mm or more complete with base plate and 4 nos. Jtype En 8 grade foundation bolts M24X750mm to withstand 180 KM / HR wind speed considering the weight. Solar lights fixed on the top of the pole . AIO Integrated Solar lights . One no of AIO Solar lights at a height of 7 mtr above ground .Both the Octagonal pole, En8 grade fdn bolts and bracket must be manufactured in the Octagonal pole manufacturing company. ( Bracket & En8 grade Fdn bolts manufactured by third party pole supplier/manufacturer shall not be acceptable). Make:- Utkarsh/RR Ispat/Vakrangee . After deduction of 10% on lowest price i.e.Rs. 19228 |
| 90 | PHSupplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. a) 110mm diameter U-PVC SWR pipes |
| 91 | 110mm U-PVC P-trap |
| 92 | 110mm U-PVC single junction door |
| 93 | 110mm U-PVC door bend |
| 94 | 110mm U-PVC Offset |
| 95 | 110mm U-PVC plain bend |
| 96 | 110mm U-PVC vent cowl |
| 97 | 125 mm dia C.P Grating |
| 98 | 75mm diameter U-PVC pipes |
| 99 | 75mm U-PVC Plain bend |
| 100 | 75mm U-PVC Door bend |
| 101 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in floors, on 25mm thick bed of cement mortar 1:1 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C.(a) Ground floor |
| 102 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados/skirtings on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing etc. all complete as per direction of the E.I.C.(a) Ground floor |
| 103 | supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking HCI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C.a) 250 mm thick wall |
| 104 | Supplying all materials, labour, T&P and laying in trenches U-PVC (4 Kgf/cm2) ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and providing bed concrete in P:C:C (1:4:8) using 40 mm size metal and allround encasing the pipe with refilling of trenches etc all complete as per P.H specification and direction of the E.I.C.a) 110 mm dia U-PVC Pipe Sewerage line with all round encasing ( IS-4985/2000- 4 Kgf/Cm2) |
| 105 | Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) & PVC Seat cover etc all complete as per specification and direction of the E.I.C. EWC with 'P' & 'S' Trap plain and Seat Cover(Hindware/Parryware) |
| 106 | Supplying all materials, labour, T&P and Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C |
| 107 | Supplying all materials, labour, T&P and fixing the Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 108 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, Fly ash Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C. a) Inside size 760mm x 760mm x 460mm |
| 109 | Additional Depth |
| 110 | Supplying all materials labour T&P and construction of Man hole chamber of the following sizes with cc (1:3:6) using 40mm size hg metal on bed 1st class KB brick work in cm (1:6) moulding and shaping the channel inside and benching with cc (1:1.5:3) using 12mm size hg chips 12mm thick cp (1:3) with punning to inside cement flush pointing (1:3) to outside RCC cover slab in cc (1:1.5:3) using 12mm size hg chips with RCC m.h. cover, e.w. in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of EIC.(a) Inside size 910x910x910mm |
| 111 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:2:4) mix using 12 mm size H.G chips, foundation concrete (1:4:8) using 40 mm size HG metal on bed and around trap ,Fly ash Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C.Inside size 250mm x 250mm |
| 112 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and Fly ash brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.a) 1.20 m diax 2.0 m deep soakway pit |
| 113 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast R.C.C rings joined loose gravel backing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.a) 0.91 m diax 2.10 m deep soakway pit |
| 114 | Providing and fixing Chlorinated polyvinyl Chloride (CPVC) Pipes conforming to I.S 15778 having the thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 mtr spacing, this includes jointing of pipes and fittings with one step solvent cement and testing of joints etc all complete as per direction of the E.I.C. a) 20mm dia C- PVC pipes (Internal) |
| 115 | 25mm dia C-PVC pipes (Internal) |
| 116 | supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking GI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C.a) 250mm thick wall |
| 117 | supplying all materials, labour, T&P and cutting grooves in pucca Floors, and walls for taking G.I/PVC pipes and fittings and repairing the holes after insertion of pipes etc with C.C (1:3:6) including finishing with 12mm C.P (1:3) complete so as to make it leak proof etc. all complete as per P.H. specification and direction of E.I.C. |
| 118 | Supplying all materials, labour T&P and fixing wash basins with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C. a) 550mmx400mm W.H.basin (Hindware/Parryware) |
| 119 | W.H.B Pedestrial |
| 120 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the E.I.C.a) Fixing of Glass Mirror 600mm x 450mm size B.E Mirror |
| 121 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C. a) 20mm x 450mm long CP towel rail |
| 122 | b) C.P Towel ring (St) |
| 123 | Supplying all materials, labour T&P and fitting and fixing of C.P Shower with 15mm or 20mm inlet with C.P Shower arm including polishing etc all complete as per specification and direction of the E.I.C. 15 mm dia C.P Shower with arm (Parryware make) |
| 124 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C. CP soap holder |
| 125 | Supplying all materials labour T&P and fixing of standard size Acrylic shelf with cp brass brackets and guard rail complete fixed to wooden plugs with cp screws as per PH specification and direction of EIC.a)450 x 125mm size Plate Acrylic Shelf |
| 126 | Supplying all materials, labour T&P and fixing Stainless Steel Kitchen Sink with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for Sink including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C. a) 550 x 450 x 200mm stainless steel kitchen sink |
| 127 | Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C.(a) Initial lift upto 1.50 mtr |
| 128 | From 1.50mtr to 3.00mtr |
| 129 | Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C. |
| 130 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 131 | Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 132 | Supplying all materials,labour, T&P and providing Brick work with Fly ash Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.(a) In Foundation and Plinth in C:M (1:3) |
| 133 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.a) 20mm thick C.P with C.M. (1:4) |
| 134 | Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 135 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.a) R.C.C Slab |
| 136 | Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 137 | Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 138 | Supplying all materials, labour, T&P and making M.S. Step Iron in 12mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C. |
| 139 | Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 140 | Supplying all materials, labour, T&P and providing 110mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 141 | Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 142 | Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C. |
| 143 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC Pipes conforming to ASTM-D-1785/89(sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C. a) 32mm dia PVC-ASTM pipes (External) |
| 144 | 25mm dia PVC-ASTM pipes (External) |
| 145 | 25mm dia HDPE pipes |
| 146 | Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C.(Jaquar make) a) 15mm dia CP Bib Cock |
| 147 | 15mm dia CP Angle Stop Cock |
| 148 | 15mm dia CP Pillar Cock |
| 149 | 15mm dia CP (L.B) Bib Cock |
| 150 | 15mm dia CP Heath Fuccet |
| 151 | 15mm dia 2-in-1 Bib Cock |
| 152 | 25mm dia Brass Full Way Valve |
| 153 | 32mm dia Brass Full Way Valve |
| 154 | 15mm dia CP Extension Nipple |
| 155 | 15mm dia CP Flange |
| 156 | Supplying all labour T&P material and installation of 5 KVA Auto Stabilizer of ISI Mark at rating of 90 Volt to 220 Volt including supply of all required accssories and testing the stabilizer including carriage, loading and unloading along with electrification etc. all complete as per specification and direction of Engineer-in-charge. |
| 157 | Supplying all materials, labour T&P and fitting and fixing 10 Ltrs capacity PVC low level flushing cistern with a pair of C.I. or M.S.brackets complete with fittings such as syphonic arrangement, 15mm nominal size Brass/PVC ball valve with polythene float, CP/Brass handle, unions and couplings for connection with inlet, outlet, overflow pipes, 32mm dia PVC flush bend, 15mm dia PVC connection pipes including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main with etc all complete as per specification and direction of the E.I.C. a) 10 lit PVC L/L Cistern |
| 158 | Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.a) 2000 lits capacity on the roof of 1st. floor |
| 159 | Supplying all materials, labour, T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 15701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.a) 2000 lits capacity on the roof of 1st floor Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy