| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 3 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 8 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 9 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 10 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 11 | Providing and fixing factory made PVC door Shutter….....do…....E/I |
| 12 | roviding designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in superstrure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 13 | Providing 12 mm thick cement plaster (1:6) -do- all complete as per building specification and direction of E/I. |
| 14 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 15 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black f inished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 16 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 17 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge |
| 18 | Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l . |
| 19 | Providing and fixing G.M. non return valve Horizontal / vertical type of approved quality as per specification and direction of E/l.(A) Horizontal non return valve(2) 20 mm dia wt not less than 250 gms |
| 20 | .(B) Vertical non return valve (1)15 mm dia wt not less than 150 gms |
| 21 | Supplying, Fitting and Fixing vitreous white glazed earthen ware I.W.C. 0f parry hindustan or any other I.S.S. approved make with low level P.V.C. sistern ---do---do----all complete as per building specification and direction of E/I. |
| 22 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . |
| 23 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 24 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.12.42.1 Coupler 110mm |
| 25 | 12.42.2 Single pushfit Coupler 110mm |
| 26 | 12.42.3 ingle tee with door |
| 27 | 12.42.4 ingle tee without door |
| 28 | 12.42.5 Bend 87.5° 110mm |
| 29 | 12.42.6 hoe (Plain) 110mm |
| 30 | Supplying labours, tools and tackles for cleaning filled and choaked man hole, septic tank, inspection chamber, gullay pits, sewerage tank etc. in all lift and disposal of spoils upto a lead of 50 M all complete as per specification and direction of E/l. |
| 31 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 32 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 33 | Point wiring in PVC conduit, with piano type switch -Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as requiredGroup A |
| 34 | S/F piano type switch/socket - Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required.5/6 amps, one way switch |
| 35 | 15/16 amps, one way switch |
| 36 | 3 pin 5/6 amps, socket outlet |
| 37 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 38 | 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 39 | S/F power plug point with piano type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as requird. |
| 40 | S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required. |
| 41 | SITC of followitn rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required.10/12 W Led Tube Light |
| 42 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire uitable for 230V 50H2, single phase supply etc. complete as required.1200mm (48\\") Ceiling Fan |
| 43 | Supplying 16''(400mm) Wall mounted fan\\" |
| 44 | S/F Modular type electronic fan regulator : Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 45 | S/F 'B' series, S.P. MCB -Supplying and fixing 6 amps to rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required6/32 amps, single pole \\"B\\" series |
| 46 | S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.6/32 Amps, SPN |
| 47 | 50/63 amps, DP |
| 48 | Carriage of material:-Cement (Lead 3.0 km ) |
| 49 | Sand (Barakar) lead 35.0 km Qty |
| 50 | Brick(lead8.0Km) |
| 51 | Stone Chips lead 17 km Qty |
| 52 | Steel (Lead 3.0 km) |
| 53 | Add 18% GST |
| 54 | Add 1% Labour Cess Please Enable Macros to View BoQ information |