| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-06-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-06-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed. |
| 2 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 3 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. |
| 4 | Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 5 | S & F of 20mm thick, second class hard wood boarding, plane on one side with butt joints and fixed complete in position as in eaves board, etc. complete all as specified and directed. |
| 6 | M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top: (i) Taking out old roof tratment and roughening tha same old concrete slab by picking, sweepingc clean and washing down with water to remove dust etc.(ii) Screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement (WPC shall be measured and paid seperately)(iii) Cleaning the plastered roof surface and applying one coat of cold bituminuous primer @ 0.25 ltr/Sqm confirming ti IS: 3384 -1986(iv) APP based polymeric menbrane 3mm thick (minimum) weighing 3.5 kg/Sqm reinfiorced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be less appliedb over bituminous primer as specified above over a application of polymeric membrane shall by torch application. The overlaps shall be minimum 100mm on the teransverese direction and 75mm on longitudinal direction. (v) Applying one coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. |
| 7 | Demolition of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified and directed. |
| 8 | M & L for 4 mm thick thick oceanic pre-primed self embossed non asbestos fiber,flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture , fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified and directed. |
| 9 | Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position complete all as specified and directed. |
| 10 | M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular, triangular in section, bull nosed, splayed, chamfered or rounded on one edge or face, clean sawn, secured with screws, cross sectional area exceeding 6 sqcm but not exceeding 13 sqcm complete all as specified and directed. |
| 11 | M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular, triangular in section, bull nosed, splayed, chamfered or rounded on one edge or face, wrought secured with screws, cross sectional area exceeding 3 sqcm but not exceeding 6 sqcm complete all as specified & as directed. |
| 12 | M & L for preparation of new or previously untreated wood or wooden surfaces of any description, not exceeding 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 13 | Demolition of ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 14 | M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M 10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:6) complete all as specified and as directed. |
| 15 | Taking down cement plaster, any description, on brick or stone walls, etc.including racking out joints, hacking for key, scrubbing down with water, etc. including removal of rubbish material away from site, complete all as specified and as directed. |
| 16 | Material and labour for plastering 15 mm thick (in two layers of 10mm and 5mm thk) on fair faces of brick wall or concrete surfaces in cement mortar 1:4 with water proofing compound as per manufacturer's printed instruction finished even and fair complete all as specified and directed.Note: Water proofing compound shall be measured and paid for separately. |
| 17 | Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed. |
| 18 | Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. |
| 19 | Supply only integral water proofing compound complete all as specified and directed. |
| 20 | M&L for complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. |
| 21 | M&L for preparation of new surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. |
| 22 | M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over a coat of suitable primer with auto roller over 1mm thick wall care putty complete all as specified and as directed. |
| 23 | M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of suitable primer with auto roller over 1 mm thick putty to match the surfaces complete all as specified and as directed. |
| 24 | M&L for complete removal of existing treatment on ceiling surfaces by scrapping, washing & rubbing down including applying a layer 1 mm wall care (putty) for making the surface even & smooth and applying two coats of oil bound distemper over a coat of Alkali resistant primer including necessary cleaning splashes of paints from window panes and floor etc complete all as specified and directed. |
| 25 | Preparation of old decorated surfaces on ceilings and applying two coats of white wash complete all as specified and as directed. |
| 26 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 27 | M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and as directed. |
| 28 | M&L for preparation of old painted surface of steel and iron of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed (Spray painting). |
| 29 | Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed. |
| 30 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 31 | M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection and making 50mm deep joints at every 3 mtr enterval and at every corners and filling the joints with bitumen grade 85/25 and sand mixture 1:3 complete all as specified and as directed. |
| 32 | M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 33 | M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 34 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 35 | M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 36 | M&L for Non Skid joint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4 complete all as specified and as directed. |
| 37 | M&L for Glazed ceramic tiles on vertical surface of size 450X 300X 7-8mm or 300x250x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coat in CM 1:4 with wire markings to receive tile over it, complete all as specified and as directed. |
| 38 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc. complete all as specified and as directed. |
| 39 | M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 40 | M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 41 | M & L for 20 to 25 mm thick machine cut mirror polished Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed. |
| 42 | M&L for treating the surface with beewax polish for old kota stone surface after machine polishing complete all as specified and directed. |
| 43 | M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 20 cm X 20 cm X 25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 15 mm thick bedding of cement mortar(1:4) all as specified and as directed. |
| 44 | M & L for precast RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) complete with joints to match complete all as specified and as directed. (Note: Reinforcement shall be measured and paid seperately) |
| 45 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed. |
| 46 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed. |
| 47 | M & L for cement concrete in foundation, filling and mass concrete in M5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 48 | Material and labour for plastering 15 mm thick in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. |
| 49 | M & L for applying two coats of Acrylic polymer modified cementitious waterproofing coating on plastered surfaces as per manufacturer instructions etc complete all as specified and directed. |
| 50 | Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. |
| 51 | S&F in repair rotational moulded polyethylene water storage tank 500 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed |
| 52 | S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed. |
| 53 | S & F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. |
| 54 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 55 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 56 | Fixing only to walls and ceilings or laid in floors 15 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 57 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. |
| 58 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 59 | Fixing only to walls and ceilings or laid in floors 20 mm nominal bore, any grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 60 | Cutting chases in stone, concrete block walls & slabs to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. |
| 61 | S & F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves/ angle valve as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 62 | S&F in repair bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and as directed. |
| 63 | S & F in repair 15 mm bore CP fancy type 2 in 1 bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 64 | S & F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 65 | S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. |
| 66 | S & F in repairs 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 67 | M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. |
| 68 | S&F vitreous china wash down water closet pan (Pedestal pattern) with 'P' or 'S' trap white (excluding flushing cistern and flush pipe) including connection to trap and cistern, flush pipe including black plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor, complete all as specified and as directed. |
| 69 | S & F in repair Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( 1:5:10, using 40 mm graded stone aggregates), and finishing the top surfaces to match with the existing flooring as in repairs (bore 110 mm) complete all as specified and directed. |
| 70 | S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. with grating and union for discharge pipe all as specified and as directed. |
| 71 | S & F in repair 10 litres cap PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with 32mm dia PVC flush pipe of suitable length complete all as specified and directed. |
| 72 | S & F vitreous china counter type wash hand basin, ovel shape size 550 mm x 400 mm including brackets including 32 mm PVC waste coupling suitable for wash hand basin with long screwed shanks and fly nuts and PVC waste pipe 32mm bore including pedastal complete all as specified and as directed. |
| 73 | S & F in repairs 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 74 | S&F in repair PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed. |
| 75 | S&F in repair PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed. |
| 76 | S & F in repair SWR vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 77 | S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified and as directed. |
| 78 | S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified and as directed. |
| 79 | S & F in repair PVC SWR Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 80 | S & F in repair PVC SWR Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 81 | Supply and fix in repairs PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. |
| 82 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 83 | Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m each and removing away from site, complete all as specified and as directed. |
| 84 | Resecuring or easing & adjusting without taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed. |
| 85 | Taking down old defective shutters of any description (wooden or aluminium) n. exc 1.0 sq.m each complete all as specified and as directed. |
| 86 | Taking down old defective shutters of any description (wooden or aluminium) exc 1.0 sqm but n. exc 2.0 sqm each complete all as specified and as directed. |
| 87 | M&L mild steel work as in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, hooks (stay) heavy for large gates, hooks and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 88 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges or slab staging for water tank or filling of chowkhats complete all as specified and as directed. |
| 89 | S&F 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed. |
| 90 | Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed. |
| 91 | S&F of 35mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed. |
| 92 | Supply and fixing of solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. |
| 93 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 94 | S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. |
| 95 | S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed. |
| 96 | S & F in repairs stainless steel decorative pattern bracket and holders/ end support for 25 mm dia curtain rod, made out of stainless steel sheet of grade X02Cr19NilO (304 S2), surface finish No. 4 as per IS 6911: 1992 complete all as specified and as directed. |
| 97 | S & F in repairs stainless steel drapery rod decorative pattern (1 mm thick stainless steel section outer dia 25 mm) including standard screws complete all as specified and directed. |
| 98 | M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 99 | S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. |
| 100 | S & F 200 mm size, mild steel barrel tower bolts with mild steel barrel and mild steel bolt, dia of bolt 10 mm, bolt finished bright, other parts finished stove enamelled black complete all as specified and as directed. |
| 101 | S & F mild steel, pressed oval type, 150 mm size, stove enamelled black finish complete all as specified and as directed. |
| 102 | S & F mild steel sliding door bolts, type I (plate type), size 250 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed. |
| 103 | S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. |
| 104 | S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed. |
| 105 | S & F in repairs mild steel sliding door bolts, type I (plate type), size 250 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum complete all as specified and as directed. |
| 106 | S & F in repairs 200 mm size, mild steel barrel tower bolts with mild steel barrel and mild steel bolt, dia of bolt 10 mm, bolt finished bright, other parts finished stove enamelled black complete all as specified and as directed. |
| 107 | S & F in repairs mild steel handle, pressed oval type, 150 mm size, stove enamelled black finish complete all as specified and as directed. |
| 108 | S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. |
| 109 | S & F in repairs galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. |
| 110 | Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 111 | S & F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 112 | M&L for forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete alll as specified and directed. |
| 113 | Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting angle iron, roof top MS sheets, railings etc. complete all as specified and directed. |
| 114 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed. |
| 115 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 116 | M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed. |
| 117 | M & L for green marble work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including laying over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed. |
| 118 | S&F IN REPAIRS, Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and as directed. |
| 119 | S & F of 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and directed. |
| 120 | S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. |
| 121 | S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, fancy type including fixing to steel pipe or union complete all as specified and as directed. |
| 122 | S & F in repairs 32/ 40mm dia, 600 mm long PVC flexible Waste pipe to WHB/urinals/Sink complete all as specified and as directed. |
| 123 | M&L for water proofing treatment to RCC sunken slab, including parapet comprising with the following courses of treatment/ specification from bottom to top:- (i) Taking out old sunken treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc. and applying cement slurry @ 3kg/Sqm (ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note : WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr/Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminium paint over the APP modified membrance @0.11Kg/Sqm. |
| 124 | S & F in repair SWR vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 125 | S & F in repair of PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 126 | S & F UPVC reducer, 75 mm and 110 mm dia on opposite ends conforming to IS 14735: 1999 complete all as specified and directed. |
| 127 | M & L for powder coated (colour) aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing including handle, tower bolt, door stopper, grills etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. |
| 128 | M & L for powder coated (powdwe quoting min 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including provn of glazing with 5mm thk glass fixed to frame, complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. |
| 129 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 130 | Supply & fix sheet glass, ordinary quality, ground or obscured or frosted, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 131 | S & F in repairs 5 mm thick bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 132 | M & L for plain, galvanised, mild steel sheeting with grade of zinc coating 275, 0.63 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed. |
| 133 | M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over one coat of suitable primer complete all as specified and as directed |
| 134 | M & L for 1 mm thick wall care putty on wall/ ceilings complete all as specified and as directed. |
| 135 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and directed |
| 136 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 137 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 138 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail