| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-05-2026 | Corrigendum / Addendum | Other | 30-05-2026 |
| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked material( All kinds of soil) |
| 4 | P/L of Hand packed stone boulder (size 150mm-230mm) before laying of PCC compacted consolidated rammed filling the voids compacting all complete carriage upto site of work all head loads complete job. |
| 5 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 7 | Supplying stacking and laying of good earth at site including spreading, levelling watering in layers and consolidated including carriage of all materials 25 Km lead. |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. |
| 10 | All works upto plinth level |
| 11 | All works above plinth level upto floor V level |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:2:4 (1Cement: 2 fine sand: 4 grade stone aggregate 20mm nominal size) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 14 | Foundations, footings, bases for columns |
| 15 | Suspended floors, roofs, landings, balconies and access platforms. |
| 16 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 17 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Columns, pillars, piers, abutments, posts and struts. |
| 19 | Stairs (excluding landings) except spiral staircases. |
| 20 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 21 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 22 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 23 | Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone (Nallah) |
| 24 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand) (Quarry) |
| 25 | 12 mm thick cement plaster in 1:6 cement mortar in walls using coarse sand. Including all leads, lifts and carriage upto site of work complete. |
| 26 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 27 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.d curing complete as per the directions of engineer-in-charge.2 mm thick |
| 28 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 29 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 30 | Tile brick masonry work 5cm thick with common burnt clay non modular tile bricks of class designation 10 in cement mortar 1:3 (1 cement : 3 coarse sand) and curing complete in superstructure above plinth level upto floor five level. |
| 31 | Providing and applying high performance top coat sealer of approved make on the exposed surface on clay tile to form invisible barrier by allowing vapour to escape for resistance against water alkalies, acid staining, freeze thaw damages. The sealer should be applied @2Ltr per 285 Sft of surface area complete as per directions of Engineer in-Charge. |
| 32 | Providing and fixing of 12mm thick wooden knotted panelling in soffits including underneath frame work of battens 50 x 25mm, finishing with two or more coats of touch wood etc. all complete upto the satisfaction of EIC. |
| 33 | Applying Priming coat: with ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.(two or more coats on new work) |
| 35 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws Budloo/fir wood |
| 36 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position : Budloo / Fir wood |
| 37 | Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss crossing GI wire. |
| 38 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.68.1 sqm sqm 11.68 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 39 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 40 | Providing and fixing 8mm thick AC IV, HDF, synthetic, laminated wooden flooring in approved shades and colours laod over 1-2mm thick foam including cost of 25x20mm conceave beading complete job and 50 mm thick cement conct levelling coat in M-15 mix. |
| 41 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm. |
| 42 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 43 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 44 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab upto 0.5 sqm) (18 mm) |
| 45 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 46 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required (including cost of all material, leads, lifts and carriages etc upto site of work complete).Incl ridges & valleys all complete. |
| 47 | Providing and fixing 0.30mm thick GI sheets in linings of soffits including underneath frame work of of wooden jambs of size 50x25 mm, including wooden cornice of required size. The job shall also include scaffolding etc |
| 48 | Providing and fixing plained eaves boarding.2nd class kail wood 250x32 mm (nominal size ) |
| 49 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Chaar Gul |
| 50 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge (Frame work shall be paid for separately). 12mm thick commercial ply conforming to S : 1328 BWR type |
| 51 | French spirit polishing, Two or more coats on new works including a coat of wood filler |
| 52 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with GI channels 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with CI hannels 25x4 mm and GI mesh etc from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over G.I frame work and suspenders complete. the Designis to be approved by the EIC (for measurements only surface area should be measured) |
| 53 | Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overall dimension, as below (tolerance+/-1mm with wall thickness 2.0mm +/-0.2mm, corners of the door frame to be joined with galvanized brackets and stainless steel screws, joint mitred and plastic welded. The hinges side vertical of the frames reinforced by galvanized MS tube of size 19x19mm and 1mm +/-0.1mm wall thickness and three numbers stainless steel hinges fixed to the frame complete as per manufacturers’ specifications and direction of engineer-in-charge) Extruded section profile size 42x50mm |
| 54 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm) |
| 55 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm). |
| 56 | Providing and fixing 6mm thick toughened glass panles of standard quality fixed to Upvc windows including cost of silicone sealant etc all complete |
| 57 | Providing and fixing wire mesh of standard quality for Upvc windows/doors including cost of all accessories complete job |
| 58 | Providing and fixing 50mm wooden cornice with nails/adhesive etc all complete (KD/Kail/etc) |
| 59 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 60 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo Mechanically Treated bars of grade Fe-500D or more. |
| 61 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 62 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. |
| 63 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 64 | Providing, fixing, testing and commissioning of white vitreous china wall mounted European water closet including providing & fixing CP bolts, nuts, fisher / anchor bolt are required for hangong of WC, nuts, supporting arrangements, bakelite/poly propylene seat & cover with CP hinges & rubber buffers, WC pan connector (straight /offset type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector) complete with all accessories. Including cutting & making good the walls & floors wherever required. |
| 65 | Providing and fixing, testing and commissioning of concealed type cistern comprising of actuator button facia assembly including kombifix -designer line Tool free series (chair bracket ,drainage pipe & wall mounting framing) brass / SS screws and washer complete, cutting and making good the walls floors wherever required. |
| 66 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass serews and washers complete. |
| 67 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 68 | Providing and fixing 45 to 60 cm long PVC connections of superior quality |
| 69 | Providing and fixing PTMT liquid soap container 109 mm wide. 125 mm high and l112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 70 | Providing and fixing toilet paper holder C.P. brass |
| 71 | Providing, fixing, testing and commissioning of star white colour vitreous china below / over counter Oval Wash Basin / circular basin (Size 560 x 410 mm or as/architectural detail drawing) with CP brass waste assembly complete including CI / MS brackets duly painted, cutting and making good the walls floors wherever required. |
| 72 | Providing and fixing Health Faucet of approved make |
| 73 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 74 | Providing and fixing PVC waste pipe of approved make |
| 75 | Providing and fixing CP waste (Coupling)of approved make |
| 76 | Providing and fixing Wall/Basin mixer of approved make (Jaquar/ Euronics/ Hindware or equivalnet brand) |
| 77 | Providing and fixing Sink mixer of approved make (Jaquar/ Euronics/ Hindware or equivalnet brand) |
| 78 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 200mm |
| 79 | Providing and fixing 5mm thick glass mirror of standard quality including cost of buffing edging and all fixing arrangement complete job |
| 80 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 81 | Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 82 | PN-16 pipe , 20mm OD(SDR-7.4 |
| 83 | PN-16 pipe , 25mm OD(SDR-7.4 |
| 84 | External work including trenching, refilling etc. |
| 85 | PN-16 pipe , 20mm OD (SDR-7.4) |
| 86 | PN-16 pipe , 25mm OD (SDR-7.4) |
| 87 | PN-16 pipe , 32mm OD (SDR-7.4) |
| 88 | PN-16 pipe , 40mm OD (SDR-7.4) |
| 89 | Providing and fixing PPR Unions of standard quality. |
| 90 | PPR Union 20mm |
| 91 | PPR Union 25mm |
| 92 | PPR Union 32mm |
| 93 | Providing and fixing ball valve 20 mm PPR of approved make |
| 94 | Providing and fixing ball valve 25 mm PPR of approved make |
| 95 | Providing and fixing ball valve 32 mm PPR of approved make |
| 96 | Providing and fixing ball valve 40 mm PPR of approved make |
| 97 | Providing and placing on terrace (at all floor levels) polythene water storage tank with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but excluding all fittings and the base support for tank |
| 98 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) |
| 99 | 32 mm dia. nominal bore |
| 100 | 40 mm dia. nominal bore |
| 101 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required, White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 102 | Providing 32 mm dia. C.P. brass trap of approved make. |
| 103 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 104 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively. |
| 105 | Providing and fixing CP 15 mm Urinal spreader size 95x69x100 mm with ½” BSP thread and shapes of approved make (Cera/Jaquar/Parryware/ or equivalent make) |
| 106 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in charge. |
| 107 | Providing and fixing PVC pipes including PVC fittings laid in required gradient, inclding cost of all fixing accessories complete job as directed by EIC |
| 108 | 75mm dia |
| 109 | 100mm dia |
| 110 | 150mm dia |
| 111 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design |
| 112 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 113 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 114 | Dismantling of fencing including Grill including stacking of serviceable material and disposal of unserveceable material as per the directions of Engineer in charge. |
| 115 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm |
| 116 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. |
| 117 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 118 | Providing and laying of hand packed stone boulder (size 150mm-230mm) before laying of PCC compacted consolidated rammed filling the voids compacting all complete carriage upto site of work all head loads complete job. |
| 119 | Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: |
| 120 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: (1:3:6) mix |
| 121 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 122 | Construction wooden storage cabinets in 19mm thick ply on all sides, shelves etc. The shutters are shall be of 22mm thick ply wood. All exposed surfaces shall be fixed with Dulmica of approved colour/shade etc. including cost of all fittings and fixtures like locks, handles, T-bolts, hinges etc all complete 450mm deep |
| 123 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) |
| 124 | For fixed portion |
| 125 | Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 126 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) |
| 127 | Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 128 | Providing and fixing 4mm thick APP/ACP panels lightweight, non-corrosive, made of high grade aluminum, PE/powder coated fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 129 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 130 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminum tabular handle bar |
| 131 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 132 | Construction wooden cubicles fabricated out of 25mm thick top MDF board. The sides shall be made with the 18mm MDF board. The cost shall also involve making one almirah and one drawer. All exposed surfaces shall be fixed with Dulmica of approved colour/shade etc. including cost of all fittings and fixtures like locks, handles, T-bolts, hinges etc all complete 3'3\\" deep as per the drawings furnished by the EIC (For payments top surface of table be taken into account ) |
| 133 | Carriage of material by mechanical Transport including loading, unloading etc. complete. |
| 134 | Course Aggregate for an average lead of 15 Kms from approved source. |
| 135 | Sand for an average lead of 15 Kms from approved source. |
| 136 | Stones for an average lead of 15 Kms from approved source. |
| 137 | Bricks for an average lead of 30 Kms from approved source. |
| 138 | Electric-Part |
| 139 | Part A (Internal Electricfication) for shrine/Guard Room/Mosque |
| 140 | Wiring for Light point/Exhaust fan point with (P+N+E) 3x1.5 sq.mm FRLS.HPVC insulated Multi strand Copper conductor single core cable (Salzer/ Polycab/ FInolex/ Paraflix/ Equivalent Make) in existing surface/ recessad Conduits (Including Cost of Condule) laid in slabs with 01 No.of 6 Amp Modular Switch, Modular Plate, Cover in front & suitable GI box etc ISO/IEC Certified Havells (Crab-Tree Athenal/Legrand (Myrls)/ Anchor Rooma Plus/ Schneider(ZenceloY/ SSK(NV) Make & shall be approved before execution of work. |
| 141 | Wiring for Ceiling fan polnt with (P+N+E) 3x1.5 sq.mm FRIS-H PVC Insulated Multi strand Capper conductor single core cable (Salzer / Polycab/ Finolex/ Parafix/ Equlvalent Make) in surface/recessed Conduits including Cost of Conduit (Havells/Polycab/Anchor Make) with 01 No. of 6 Amp Modular Switch, Modular Plate,Cover in front and suitable Gi box etc ISO/IEC Certified Havells(Crab-Tree Athenal/ Legrand (Myris/Anchot Rooma Plus/ Schneider (Zencelo) /SSK (NV) Make & shall be approved before execution of work. |
| 142 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required, ISO/lEC Certified of Havells (crab- Tree Athenay/Legrand (Myris/Anchor Rooma Plus/ Schnelder(encelo)/SSK(NV) Make & shall be approved before execution of work. |
| 143 | Wiring for Power Plug with (P+N+E) 3x4sq.mm FRIS-H PVC insulated Multi strand Copper Conductor Singe core cable in surface/Recessed Condule (Including Cost of conduit)(Salzer/Polycab/Flolex/Paraflix/Equlvalent Make) |
| 144 | Supplying and fixing sultable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/ IEC Certified Havells(Crab-Tree Athena)/ Legrand(Myris)/ Anchor Rooma Plus/ Schneider( Zencelo)/ SSK (NV) Make & shali be approved before execution of work. |
| 145 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/ Recessed Conduit (Including Cost of Conduit (Salzer/ Polycab/ Finolex/ Paraflix/ Equivalent Make) |
| 146 | Supplying and fixing suitable size Gl.box with modular plate and cover In front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc: as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree Athena)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/SSK(NV) Make & shall be approved before execution of work. |
| 147 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC Insulated copper conductor, single core Cable In surface/Recessed medium class PVC condult (Including Cost of Conduit) (Salzer/ Polycab/ FInolex/ Paraflix/ Equivalent Make) & shall be approved before execution of work |
| 148 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution |
| 149 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ Inverter/AC Point Sub main In One run from Main Panel to Distribution Boards. |
| 150 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/ Inverter Circuit in One run from switch boards to Distribution Boards. |
| 151 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells (Crab-Tree Athena)/ Legrand (Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/SSK(NV) Make & shall be approved before execution of work. |
| 152 | Supply/ Fixing/ Testing and Commissioning of 6Amp to 32Amp Rating SP,240v, °C* Curve 10K, Miniature Circuit Breaker sultable for inductive load In existing MCB. DB Complete with connections. (L&T/Siemens/ Legrand/ ABB / Schnelder Make). |
| 153 | Supply/ Fixing/ Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K, Miniature Circult Breaker (MCB in the existing MCB DB complete with connections. (L&T/Siemens / Legrand/ABB/Schneider Make) |
| 154 | 32Amp |
| 155 | 40Amp |
| 156 | 63Amp |
| 157 | Supplying and Fixing of MCB 8-Way (4+24) horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted Including earthing etc, as required. (L&T/Siemens/Legrand/ABB/Schneider Make) |
| 158 | Supplying and Fixing of MCB 8-Way horizontal typed, sheet steel, Double Door Distribution Board, SPN 240V V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required (L&T/ Siemens/ Legrand/ ABB/ Schneider Make) |
| 159 | EVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply.Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man-hole cover for the above, Including cost of 20mm Wide copper strip as required In one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through sultable DWC High Density Poly ethylene Pipe having Corrugation complete job |
| 160 | Supply/ Installation/ Testing and Commissioning of 15W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD < 10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of india authorised lab. The Job Includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Phillips/Wipro/Trilux/LT/Polycab Make. |
| 161 | Supply/ Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V. The Fixture should have In-bullt Surge Protection of 2kV.Certification:-LM79 & LM80 test report should be from govt approved In-house NABL lab/government of Indla authorised lab. The Job Includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Wipro/Trilux/LT/Polycab Make. |
| 162 | Supply/Installation/Testing and Commissioning of 22-24 watt ultra slim LED surface mounted lighting panels(300mm x 300mm) having CRCA Body (Commercial type), minimum lumens 100 lm/w, the luminaire housing should be crca/aluminium and the luminair optics shall have a high efficency with transmittance average life of 50000 hrs operating temperature -10 C to + 45 C. The Fixture should have In-bulit Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The Job Includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/ Wipro/ Trilux/ LT/ Polycab Make. |
| 163 | Supply/Installation/Testing and Commissioning of 36-40 watt ultra slim LED surface mounted lighting panels (600 mm x 600mm Square) having CRCA Body (Commercial type), minimum lumens 100 lm/w,the luminaire housing should be crca/aluminium and the luminair optics shall have a high efficency with transmittance average life of 50000 hrs operating temperature -10 C to + 45 C.The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The Job Includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which Includes replacement of fixtures of Philips/ Wipro/ Trilux/ LT/ Polycab Make. |
| 164 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure tilecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety Power Factor >0.95, THD(1) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but Inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Compllanced.OEM Must have Its own in house NABL lab setup for all testing facilitles for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Polycab/ Crompton/ Philips/ Equivalent Make as approved and to be installed on outside block Including S/F of suitable size of Gyser bolt. The job further Includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning/handing over of site to Intending department. |
| 165 | Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm lang down rod, 02 No. canoples, shackle kit, Power Factor not less than 0.9, Service Value Including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, súltable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Anchor/Polycab/Orient/Equivalent Make.(5-Star) & shall be approved before execution of work. |
| 166 | Supply/ Installation/ Testing and Commissioning of 225-250mm Shutuer Typed, 120 Cum/Hr. AC 220-240 Volts 50Hz. Exhaust fan made out of ABS Plastic Material with isbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Polycab/Orient Make |
| 167 | Supply/ Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity 151 Mark(IS: 15683) and dully certified. |
| 168 | Supply/ Installation/ Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg Capacity (St Mark(15: 13683) suitable for 'B' and C class fires-inflammable liquids, gaseous fires like LPG, acetylene and electrical fires. |
| 169 | Supply/ Installation/ Testing and Commissioning of 10 Watt. LED Mirror Light fitting with Aluminium Body of Philips/Wipro/Bajaj Ledvance Make including making of necessary connections Ceiling Rose, Silken wire also with round plates Etc complete. |
| 170 | Part-B (Air conditioner/Panel/Cabling) |
| 171 | Supply/ Installation/ Testing & Commissioning of 5 Star rating 1.5 TON Inverter type split Air Conditioning system suitable for operation on AC supply single phase 220 V. The Indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using sultable angle Iron stand fitted with nuts/bolts outside the room to avoid noise, Including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping If required, PVC flexible drain pipe, sultable capacity 3 core sheathed/pvc Insulated coper cable and a battery operated wireless remote unit, the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Mitsubishi/Toshiba/O-General make) Including cost of 4KVA Digital Auto control VOLTAGE Stabilizer for ACs of Approved brand for smooth functioning/constant voltage supply having etc Input voltage-90-220 volts & output voltage 220 volt & stand, Copper piping etc & all other allled accessories, Installation charges, GST, income tax, carriage etc Complete Jab. The Job Includes CMC (reckoned from date of successful commissioning) for a period of Two years. |
| 172 | Supply and Fixing of Modular 32Amp Industrial Socket outlet having fitted with 32 Amps DP MCB and Top with Modular Plate, Cover In front & suitable Gl box etc for AC Points Havells (Crab-Tree Athena)/Legrand(Myris)/Anchor Rooma Plus/Schnelder(Zencelo)/SSK(NV) Make & shall be approved before execution of work. |
| 173 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for AC Point Sub main In One run from Main Panel to AC Box. |
| 174 | Supply/ installation/ testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized, 415 volts TPN MCCB Mian Distribution panels, fabricated out of sheet steel of 16 gauge dust protected, painted Incl earth terminal with all necessary accessories as required for panel with internal wiring of panel. The Panel is to provided and fitted with following adjustable type controlling Protection switch gear devices(1) Normal Incoming.200 ARIP TRN MCCB with breaking capacity of 50 KA-thermo magnetic adjustable based of Legrand Siemens/ABB/Schinder/L&T make = 1. no 400 Amp TPN Bus bar Al Strips = 1 SetVolt meter 1 no, Ammeter 1 no, CT coils for Am meter 300/5A = 1 set, phase indicators =1set, Selector Switch = 1 No.(2) Generator Incomer.160 Amp Four Pole Change over switch of Siemens/ABB/Schinder/L&T make 1 no 400 Amp TPN Bus bar Al Strips = 1 Set, Volt meter 1 no, Ammeter 1no, CT coils for Am meter 300/5A = 1 set, phase Indicators =1set, Selector Switch = 1 No.(3) invertor/Solar incomer.100 Amp Double Pale MCB (10 KA) of Legrand/Siemens/ABB/Schinder/L&T make = 1 по 200 Amp P&N Bus bar Al Strips = 1 Set, Volt meter =1no, Ammeter = 1 no, CT colls for Am meter 300/5A 1 set, phase Indicators =1set(4) Bypass Switch: 3-Phase, Four Pole 200 Amp.415V AC, 50Hz ByPass Switch with rotatory handle in enclosure L&T/ABB/Seimens Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement for bypassing 160 KVA AVR. as approved. Outgoing(1) 100 Amps TPN MCB (10 KA) of Legrand/Siemens/ABB/Schinder/L&T make = 8 No for Heating/AC Sub main(2) 63 Amps DP MCB (10 KA) of Legrand/Siemens/ABB/Schinder/L&T make = 10 No for normal lighting sub main (3) 40 Amps Double Pole MCB (10 KA) of Legrand/Siemens/ABB/Schinder/L&T make 10 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing |
| 175 | Supply/ Installation/ Testing & Commissioning of 3-phase 160 KVA,50 Hz Oil cooled unbalancad type Voltage stabilizer SERVO control(Single Mount) of Approved brand COPPER wound of Chinar/AE/Cosco/ALBA Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications Input voltage(Ph-Ph) ranging from 277 Volts to 460 Volts and a balaaced output Voltage of 415 Volts, 12% Buck Boost Transformer Copper wound 99.9%, OIL, Itunersed COOLING OIL, High cut/Low Cut/Time delay/Over Cut through Micro Controller and Spike Protection. The job includes CMC (reckoned from date of successful commissioning) for a period of Two years. |
| 176 | P/F of sheet steel Kiosk/Canopy suitable to house 160 KVA servo stabilizer of fabricated out of 16 SWG M.S sheet having front door with locking arrangements and duly powder coated |
| 177 | Construction of Stone masonary bed using Class Ist dressed Q Stone Bed shall be 8 ft in length, 6ft wide and 2.5 ft in height above ground level and 1 ft deep under the ground. Cut work on exterior surface and cooping of cement concrete 4 inch thick lald on top of the bed with fine cement finish. The Job Includes Supply laying of 04 Inch dia PVC Prince Pipe for Incoming/Outgoing Cable Circults |
| 178 | Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make. |
| 179 | Supply/ Laying/ Connecting and Commissioning of 240 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Paramount/Polycab/RR Kabel/KEI Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench. (For Main Supply) |
| 180 | Supply/ Laying/ Connecting and Commissioning of 185 sq.mm 3.5-Core XLPE/ PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Paramount/Polycab/RR Kabel/KEI Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench. (For Generator) |
| 181 | Supply/ Laying of 25/32mm Dia PVC Condult of Anchor/ Ravinder/ Polypack/ Finolex Make with other accessories like bends, etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Tile with same Colour/ Paintwhere required etc. |
| 182 | Supply/Installation/Testing/Commissioning of SOLAR INVERTER 05 KVA/48V Pure Sinewave Solar Inverter With 150T Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 04 No. of 200Ah, 12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Havells/ Luminlous/ EXIDE/ AMRON Make. |
| 183 | Part C (Sub-Station) |
| 184 | Supply and Erection of 9 Mt. long Steel Tubular poles (Swaged type) confirming to IS-2173(part-II) of 1980 designed as 410-SP-33 planted in 1.5 m deep pole pit to be dug for the purpose, welded with 300 x 300 x 6 mm bottom plate |
| 185 | Cement bottoming 1:2:4 mix as per Standards 0.5 cum per pole |
| 186 | Centering and shuttering including struttings, propping etc and removal of form work |
| 187 | Providing and fixing of GI X-Arms Channel including clamps and braces for fixing of Pin Insulators/Disc Insulators/Link set/Dropout set etc. |
| 188 | Supply, fixing, testing and commissioning of Polymeric Composite Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer housing. Stn. Type |
| 189 | Supply, fixing, testing and commissioning of 11kV Polymeric Composite GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type.(Complete in all respects) |
| 190 | Painting of Poles Red Oxide |
| 191 | Painting of Poles Aluminium Paint |
| 192 | Providing of Galvanized Iron Channel/Angle/Flat of sizes including clamps |
| 193 | Providing and fixing of Danger plates with Clamps |
| 194 | Providing and ixing of anti-climbing device with clumps of Standard make. |
| 195 | Providing of Earthing Complete by GI Pipe 40mm 3 mtr long through G1 Strip 25x3mm |
| 196 | Providing and fixing of stone pad (30mmx30mm x75mm) |
| 197 | Supply and fixing of Galvanized stay set with 50x8mm stay clamp, guy insulator (02 No's) anchor plate 200x200x6mm) nut bolt 2 No's turn buckles, 1.8 m long 16mm dia solid GS Stay rod and 7/3 15mm dia Of standard wire complete |
| 198 | Supply, fixing, testing and commissioning of 11/0.433kV, 200KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, and with LV Cable Box having detachable Aluminlun Gland plate of ALBA/AE/Zain Electricals/Northern Make. The Item shall be inspected at source (manufacturing factory) by departmental employees before Its dispatch for which the contractor shall be liable to and fro charges by way of providing transport/alrfare, lodging and boarding for two employees. |
| 199 | Excavation of earth pit of dia 650 nm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore 4mm wall thickness & length 2.5 mtr long as Per IS 1239.Gl Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, il nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover. |
| 200 | Supply and Fixing of 50x6 mm flat Iron strip around the Transformer to hold the same along with other fixtures with the frame structure. |
| 201 | Supply/Laying/Testing and Commissioning of 300 mm² Single-Core Cable, 1.1kV Grade, XLPE un armoured FRLS type confinning to latest version of IS: 7098 (Part-ll)-1985, including cost of clamp for its fixing wherever required over head from tapping point of HT line upto sub station to connect with the HT Network of Havells/ Polycab/ RR-Kabel/ KEL/Paramount Make. (for 1 Ckt) |
| 202 | Brass Clamps |
| 203 | Al. Thimbles |
| 204 | Supply, Installation, Testing and Commissioning of 3-Phase, 4-Wire Trivector Meter Proxidy with sultable ring type CT 200 Amp with enclosure. |
| 205 | Part-D (125KVA (CPCB-4) Silent Disel Generator Trolley Mounted) |
| 206 | Supply/Installation/Testing and Commissioning of 60/62.5/63KVA 3-Phase Silent mode Diesel Generator (CPCB-4) with inbuilt AMF Panel (DG Power Set) with Trolley having 04-Wheel (Tubeless Tyres) with Suspension and braking System complete of :FG-Wilson (CATERPILLAR)/Cummins/ASHOKA LEYLAND (CSH)/Kirloskar/Palkane Make\\".. With Following technical Specifications:-(A). comprising of Diesel engine with 415 AC 50Hz oft(1) Engine Power RATING 125KVA (power factor 0.8)=100KW (II) Engine SPEED-1500RPM(iii) Engine Aspiration = Liquid cooled (Turbo charged) (iv) Engine COOLING Radiator/Liquid cooler(v) Engine Starting 12 V DC Electric with cold start kit (vi) Should have Rotary Fuel Pump(vii) Should have Pistons with oil Gallery and Piston Cooling Jet (viii) Governor Electranic AO(ix) Should operate from -45 Degree(8) Alternator:-(1) Alternator Type = Brushless Self Excited and Self Regulated (ii). Alternator Rating =125kva(iii) Voltage 415V, 3-PHASE 4Wire (power factor 0.8) (iv). Frequency 50HZ(v) Speed 1500rpm(vi) Protection IP 23(vii) Voltage repilations Automatic voltage regulation of less than && (vill). Wave regulatione less than 3% distortion(ix) Voltage regulation =± 1%(iix) Noise level less than <75DB at 1mt. DistanceAlso should Common Base Frame Batteries, Leads and Stand Anti Vibration Mountings Residential type Exhaust Silencer, Exhaust Below, First Fill of Lubricating oil, SOUND PROOF ACOUSTIC ENCLOSURE(CPCB-4) APPROVED) Standard Control panel IP-55 and ENGINE should having 5 Cylinder, Piston with oil Gallery and Piston Cooling jet, powder coated sheet metal fabricated sound proof with Silencer Canopy also adequate capacity 160 Amp TPN MCCB of L& T,12 volt Batteries with Charger Including cost all allied accessories,Income taxes, sales taxes, GST loading unloading carriage up to site and first flll 200 litres fuel Diesel for testing Complete. The item shall be Inspected at source (manufacturing factory) by departmental employees before its dispatch for which the contractor shall be liable to and fro charges by way of providing transport/airfare, lodging and boarding for two employees. |
| 207 | Supply/ Installation/ Testing and Commissioningof Maintenance free Chemical EARTHING SYSTEM Sets (Vertically installation of EARTHING SYSTEM) using Earthling copper bonded Earthing Rods of 6ft long with molecular bonding along with 2 bags (11.5 kg each) of Ground Enhancement Gem Material with each Earth Rod to reduce the soil resistivity complete job confirm to relevant international/Indian standard. The rod is to be laid vertically in a bore of required dla/depth duly excavated bore well including cost of excavation of bore well, making of surface structure in brick/cement concrete material as per drawing annexure safe Earthing electrode. The Earth rod is to be connected with 20mm wide copper strip laid through Weather proof PVC Pipe of Prince make up to DG ENGINE, ALTERNATOR, CONTROL PANEL & CANOPY in one run Including cost of COPPER Strips complete jobs Four Separate Earthings for each DG ENGINE,for Alternator, Control Panel & for Canopy |
| 208 | consruction of DG Set Foundation of 12ft In Lx 5ft in W x 4ft (2ft U/G and 2ft A/G Approximately In Ht. Ft In M20 cement concrete Ratio 50mm thick cement conc. flooring on the top of floor, also plastering in 1:6 mix, Including cost of all materials form works, 40x40x5mm angle Iron truss with 26 gauge CGI Sheet roofing dully fitted with J-hooks to cover the DG set. The angle iron truss should be rested (erected/Supported) on Posts of G.I or Jindal 6\\" dia pipes having 1--1/2ft x1-1/2 ft, 12mm thick Base, side, Top plates fitted with nut & bolts. The truss height should be at least 8 ft Complete job. The Job Shall be Monitored by concerned sub-division site Incharge (Civil Engineer) |
| 209 | PART- E (CC-TV Network) |
| 210 | Supply/ Laying/ Connecting/ Testing & Commissioning of Networking Data Cable 4-Palr, CAT-6 of D-link/ Schinider/ Legrand Make with End termination |
| 211 | Supply & Installation of IP-20 & IK-08, UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, Vertical Mounting Rall 1.6 MM with 'U'Marking, with All round protective channel on the door aperture, lock Integrated on front door, top and bottom cover with cable entry provision with gland plates, Integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessorles like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware, 1 No of 19\\" 1U, mountable socket strips with 5 nos of SA universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continulty kit, Indicator, moulded power supply cable, fixing on wall with Sultable Anchor fastner etc as required. All as per pre approved by Engineer In charge For additional technical parameters of products/work, refer Annexure \\"A\\" attached with this BSRof D-Link or Equivalent Make Including Supply of power extension cord etc:-6 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 212 | Supply/ Installation/ Testing/ Commissioning of 65 Inches 4K LED Display Monitor(24x7) as per the Specifications attached LG/SONY/Samsung Make and shall be approved by department not less than SDO. |
| 213 | Supply/ Installation/ Testing/ Commissioning of 16 Channel Network Video Recorder (NVR) as per the Specifications Enclosed with a Hard Disk Memory of 8 TB Capacity with HDMI cable patch cards. HONEYWELL/Matrix/PELCO Make and shall be approved by department not less than SDO. |
| 214 | Supply/Installation/ Testing/ Commissioning of Indoor Dome Camera IP CCTV Monitoring, Recording & Streaming System per the Following Specifications:- Minimum 4-5 megapixel progressive scan HD CMOS Lens:-3-6 mm or Better, DC-Iris/Auto Iris Field of view:-100° to 45 ° (horizontal) 72-34° (vertical) Day/night operation:-The camera should provide day/night functionality automatically switches to night mode in low-light scenes Wide dynamic range:-True WDR 100dB or equivalent or better Minimum illumination/light sensitivity:- Color mode: @0.2 lux black and white mode: @0.03 lux Video compression:- H.265 motion JPEG Resolutions and frame rates (H.265):- At 2304x1728, the frame rate shall be 25 FPS or better for viewing. All the streams shall be user configurable (with respect to resolution, frame rate & compression standard). All the cameras (sensors) shall have minimum 5 streams. PoE:- It should be PoE enabled and with IK08 enclosure and in built 20m IR Certification:- It should be FCC, CE, UL certified ONVIF HONEYWELL/Matrix/PELCO Make and shall be approved by department not less than SDO. |
| 215 | Supply/ Installation/T esting/Commissioning of Bullet Camera IP CCTV Monitoring, Recording & Streaming System per the Following Specifications:- Minimum 4-5 mega pixel progressive scan HD CMOS Lens:-3-6 mm or Better, DC-Iris/Auto Iris Field of view:-100° to 45° (horizontal) 72-34° (vertical) Day/night operation:-The camera should provide day/night functionality automatically switches to night mode in low-light scenes Wide dynamic range:-True WDR 100dB or equivalent or better Minimum Illumination /light sensitivity Honey Well/BOSCH/PELCO Make and shall be approved by department not less than SDO. |
| 216 | Supply/ Laying/ Connecting/Testing & Commissioning of Networking Data Cable 4-Pair, CAT-6 of D-link/ Schinider/Legrand Make with End termination. |
| 217 | Supply/ Installation/ Testing & Comisioning of 24 port Switch (Managed Layer-3) D-link/ Schinider/ Legrand/Juniper/Brocade make) Make with making of necessary Network connections etc |
| 218 | Supply/Installation/Testing & Commissioning of RJ-45 Cat-6 Shuttered NET JACK Modular Series of Modular Switch, Modular Plate, Cover in front, Modular blanking plate & suitable Gl box etc ISO/IEC Certified Havells/Legrand/Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work |
| 219 | Supply & lustallation of IP-20 & IK-08, Ul. Listed Wall mounted Double Section Communication enclosure rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimurn 5mm toughened glass door, Vertical Mounting Rail 1.6 MM with 'U'Marking, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 10 Horizontal Cable manager, I No of 90 cfm 230V AC Fan with I mis long cable, mounting hardware, I No of 19\\" IU, mountable socket strips with 5 nos of SA universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner ete as required. All as per pre approved by Engineer in charge For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSRof D-Link or Equivalent Make Including Supply of power extension cord etc:- |
| 220 | 6 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 221 | 9 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 222 | Part F |
| 223 | LAMP POST(Code DA-KMC-401-27/Equivalent) Supply, installation and fixing of heritage architectural ornamental decorative cast iron pole having provision to fix decorative Light fixture. Installation of same with foundation bolts of suitable size to grout it into specially designed RCC foundation, as shown in the enclosed drawing. The decorative light fixture shall be fixed on the top of the pole. The details of pole & light are given below:-A.The Pole The pole with light fixture shall look like as shown in the drawing. It shall have all similar features as shown in the enclosed drawing/picture. The Cast Iron Pole of nearly 2700/3000mm length. The pole has ornamental base (Approx.overall dimension-height 1175 mm, bottom dia 360mm) shall have a provision of inbuilt junction box for fixing MCB's or cutouts with detachable window cover. The part above ornamental base design consists of decorative chinar leaves bamboo sections of circular shapes in different dimension, is made of cast iron in fine finish. The design of the cast-iron parts is clearly shown in the drawing. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%)B.Light Fixture: The Cast Aluminium Light fittings best suitable for the Lamp Post shall be exactly similar as shown in the enclosed drawing/picture, which is of nearly 360mm width, 820mm height. The fixtures have aluminium casted parts & spinning parts welded with decorative cast aluminium designs for better look. It shall have provision of led bulb of 30watt designed to illuminate large areas with its wide dispersion without affecting the environment. It shall have extra clear transparent acrylic sheet light cover with stainless-steel fastening elements. The fixture having provision to fix complete with required power supply. Mentioned dimensions are proposed dimensions, which may vary with actual measurements (Tolerance of ±5%)C. Finish: Colour specification & finishing process must follow as per the ISI standard. All parts must be clean by SHOT blasting process. Further parts are painted in 4 layer coating(Coating thickness-125 to 150 micron) in which first layer with epoxy primer(to prevent corrosion), second layer with epoxy base colour, than third layer polyurethane (PU) metallic paint (Gold/Green/Copper/Silver) & final layer of polyurethane (PU) lacquer (to prevent ultra violets ray).D. Material Specification; All this above parts made of cast iron castings must be of FG-150 grade as per IS 210 (2009) standard, Hardness must be in range between 130 BHN to 180 BHN. Cast iron must have Chemical composition of Carbon-3.0% to 4.0% Silicon-1.0% to 2.0%, magnesium -0.5% to 0.7%, sulpher -0.02% to 0.04% & phosphorous-0.07% to 0.09% this composition is best suitable for product strength & life. |
| 224 | Providing and Laying RCC Foundation for 2.7/3 Mtr Poles) as pe drawing attach at Table P.4 with Following Procedure & Al as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure \\"A\\" attached with this BSR. (Foundation work to be luid as per drawing)(A) Excavation of Pit for Foundation Size upto required depth from Ground level(B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.(C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness(D) Reinforcement for R.C.C. work with MT bars Including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including stestting, propping etc. and removal of form work for Footing and(F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM G) Providing and Laying Reinforce cement Concrete of M-25 grade In Footing and Pedestal including Curing the foundation for 7 days.(H) Providing and Fixing Nusing Angle 40 m x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face |
| 225 | Supply and Installation of 2.7/3 Mtr lamp post (garden lighting pole of cast iron) as per the above mentioned specification and as per enclosed drawing of Dwarka/Karara Mujasame/Hi-Lite Make & (Shall be approved by Department fore Supplying) of Dwarka/Karara Mujasame/Hi-Lite Make. The item shall be inspected. |
| 226 | Supply, installation, Testing and commissioning of decorative post top light fixture of Dwarku/Karara Mujasame/Hi-Lite Make as per the specifications mentioned above and as per enclosed drawing including led Tamp B22 18-30W of Philips/Havells/Halonix/HG Make. |
| 227 | 8 in 3x1.5 Sq.mun FRL3-H of 2.7/3-Mtr Pole Havells/Snizer/RR-Kabel/Anchor make. |
| 228 | Supply/Fixing/Testing and Commissioning of 6 Amp to 10 Amp Rating, 240v, C Curve 10K,SP Miniature Circuit Breaker suitable for inductive load and to be fitted in existing poles Complete with connections. (L&T/ Siemens/ Legrand/ ABB / Havells Make) |
| 229 | Supply/ Fixing of 63 Amp 4-Way in and 4-Way out Terminal Block/Connector Bottle/Pin type depending upon site conditions of standard make. |
| 230 | Providing of Pole Earthing Using 20mm G.I solid rod to be inserted in ground included with 20mm wide G.1 strip in one run from Top of the earthing rod upto bottom of the pole duly fitted with necessary nut bolts complete Job |
| 231 | Supply/ Fixing and Crimping of 16/25/35/50 Sq. mm aluminium lugs, cable thimbles at termination of the cables/ends including providing of insulation tapes. |
| 232 | Supply/Laying/Testing and Commissioning of 4-Core 16 mm sq. Al armored XLPE Insulated, PVC cable Havells/Polycab/RR-Kabel/KEI/Paramount Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved. The cable shall include end termination lugs with its crimping /taping. |
| 233 | Design/Supply/Installation/Testing and Commissioning of CPRI Approved LT feeder panel (3+1) Al. bus bar of cubical type vermin proper Single door lockable outdoor type fabricated out of 14/16 SWG MS Sheets powder coated weather proof, dust proof with IP 65 protection with 4 legs stand of 2.5 feet height/ground clearance properly grouted in Cement Concrete base b.w.o raising the concrete jacketing (01x01) ft below & Above ground level and 08 inch of dia in 1:3:4 ratio, filter with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase, 4 wire 50Hz system complete in all respects complete in all respects with following:-Incoming: 63Amp-4 pole TPN of SEIMENS/ABB/L&T/Legrand/Schneider make as approved-01 No. Outgoing: 200 Amp Suitable Al. Bus bar, 02 No. of 32 Amp TPN MCB & Astronmical Timer. |
| 234 | Mechanical Part |
| 235 | 08 Passenger MRL Lift ANNEXURE- A (SITC OF LIFT) |
| 236 | Supply, Installation testing & Commissioning of 01 No. (G+2), 08 Passenger MRL Lift at Construction Of Directorate Office For department of Floriculture at Srinagar including all the necessary civil & electrical works such aschipping of lift shaft if necessary, lighting of lift shaft with provision of 16 amp 3-pin sockets and switches at each floor inside lift shaft, closure of lift shaft by chequered plate/sheet, brick work at landing door, plastering, Filling of pit if necessary, lintel work, granite works for facade/Front wall of lift at each floor, minor civil works and any other work required for successful installation of lift. The lift shall be suitable for 08 passengers. of standard design having speed of 1.0m/s serving from ground to 2nd floor i.e. 03 stops and 03 landings. The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards.•Machine: Gearless machine located in the shaft on the top of guiderails•Power Supply: 400/415 V (3 Phase AC)•Car Group: Simplex Full Collective Control•Traction Media: To be provided by firm.•Required Shaft dimensions: 2150 mm (W) x 1800 mm (D)(as per NBC guidelines). |
| 237 | • Required Overhead: 4200 mm• Required Pit depth: 1600 mm.• Landing door: 2 panel automatic centre opening door in stainless steel hairline.• Car Finish: Stainless steel in hairline finish.• Car door and landing door finish: Stainless steel in hairline.• Handrail: round handrail in stainless steel finish provided on rear wall of car.• Alarm button in car operating panel.• Automatic operation for car fan.• Anti-nuisance (car call Protection)• Cross Flow fan in car for ventilation• Door open and door close buttons in car operating panel.• Emergency light• Full load by-pass• Infrared screen for car door• Fire Rated Doors: 2 Hours• Overload function • Phase failure and phase reversal protection.• Automatic rescue device in case of power failure.• Attendant control.• Car Position Indicator: To be provided by firm.• Fireman control • Nudging Service • Voice Synthesizer. |
| 238 | ANNEXURE – B (SITC OF SERVOSTABILIZER AND ALLIED WORKS) |
| 239 | Supply, installation, testing & commissioning of 15 KVA servo stabilizers including all allied electrical appurtenances viz. cabling, L.T control panels, changeovers etc. The stabilizer should have following specifications:a) Capacity:15 KVA, 3-phase unbalanced type b) Input: (150-270) V AC P-N; (250-470) V AC P-P c) Output: 415 V 1% phase to phase d) Supply: 3 phase, 4 wires, 50Hz e) Operation: Automatic f) Duty cycle: Continuous g) Transformer windings: Copper wound on CRGO laminations as per IS specifications h) Cooling: Oil cooled i) Efficiency: Better than 98% at full load j) Overload capacity: 15% for continuous 4 hours k) Waveform distortions: Nil l) High speed voltage correction: up to 5V to 20V per second m) Protections: Under voltage, Over voltage and Overload with time delay n) Other features: LED indicators, Digital AC ammeter, AC voltmeter, Frequency meters, Phase Sequence meters, Single phase preventer, Stabilizer by-pass arrangement.The job also includes P/F of 100 A 4pole MCCB as incomer to servostabilizer to be provided in CRC enclosure. |
| 240 | Supply, laying, testing and commissioning of 3.5 Core 35 Sqmm aluminium armoured cable (XLPE) along with thimbles from main panel to changeover to lift panel. The job includes prior thimbling of the cables with heavy duty crimping tools followed by PVC tapping of the thimbled joints. |
| 241 | Change over panel comprising of 100A AI Bus Bar, 100A 4P, MCCB as incomer- 2 No (for power supply & DG Set) & 63 A, 4P MCCB outgoing 1 No. (for lift), changeover switches, for DG & main to be supplied in a CRC panel. |
| 242 | Waterproofing of elevator pit: Providing & Laying of integral Cement based waterproofing (Injected type) treatment including preparation of surface and then applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS: 2645. After proper curing apply a second coat of cement slurry mixed with proprietary water proofing compound. The job includes finishing the surface with 20mm thick joint less cement mortar of mix 1:4. |
| 243 | Earthing: Providing and Laying of Copper (cu) strips and cu plate for proper earthing of all Electro-mechanical components carrying main current, including but not limited to the motor and electric panel. Use of bolts or screws and cu strips to establish grounding connections on each component. The job includes earth work by using labor for making a pit of suitable size for proper earthing and after that laying copper plate of minimum size 60cm width, 60 cm height and 3.15mm thickness and filling the pit with chemicals (chemical earthing). The earthing cu strip must have cross section not less than 24 mm^2. The job further includes laying of perforated conduit pipe from ground up to cu plate having funnel at top as per actual requirement at site & as per IS 3043 (1987) |
| 244 | CMC DETAILS 1ST Year DLP |
| 245 | CMC for 2ndyear |
| 246 | CMC for 3rd year |
| 247 | DSITC of VRV system (Hot and cold) |
| 248 | VRF Outdoor Unit (HEAT PUMP TYPE) |
| 249 | Supply Installation, Testing & Commissioning of modular imported type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. |
| 250 | VRF unit and compressor shall be of same OEM make. Latest BEE guideline for AC system/ECBC/GRIHA/AHRI whichever guidelines is more stringent shall be followed based on GRIHA star rating requirement of building. The VRF units shall be able to deliver 100% capacities at AHRI conditions till ambient temperature of 39 deg C. For improvement in efficiency other than ISEER value, the VRF units will with minimum COP of 3.5 at 100% load at AHRI conditions. The VRF outdoor unit shall have operating range from 0 deg C to 50 deg C in cooling mode & (-10 Deg C to 15 Deg C) in heating mode and the OEM shall submit catalogue for VRF unit, mentioning the same. The unit shall be complete individual controller and fittings with necessary wiring, connection & termination, painted MS frame for outdoor unit, cowl for ODU etc. |
| 251 | Indoor VRV Units (Nominal Capacity) - Ceiling Mounted Cassette Round Flow/4Way type unit. |
| 252 | Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, high lift drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The units must be compatible to the above mentioned outdoor unit with wireless remote control for each indoor unit. The job also includes wireless remotes for each indoor unit. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 253 | 0.8 TR |
| 254 | 1.6 TR |
| 255 | 2.0 TR |
| 256 | 2.8 TR |
| 257 | 3.2 TR |
| 258 | 3.6 TR |
| 259 | 4.0 TR |
| 260 | Ceiling Mounted High Static Ductable TFA Unit |
| 261 | Supply, installation, testing and commissioning of following minimum capacity ceiling mounted ductable TFA unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, high lift drain pump, bird screen, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 262 | 4.0 TR-Standard VRF Ductable TFA unit with all controls & accessories |
| 263 | Refrigerant PipeSupply, Installation, testing and commissioning including vaccumization and Nitrogen testing of nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness for Suction and Liquid lines, all accessories as per specifications etc. as required. Pressure testing to be done at 1.5 times the working pressure. Thickness of the pipeline must be as per the standards of soft drawn pipes. Piping vaccumiazation, nitrogen flushing during brazing and Nitrogen testing to be done by contractor and price for the same to be included. The job also includes providing and fitting of Y-joints for refrigeration piping(pair). The job also includes p/f of resting fixtures for indoor unit, piercing of walls for laying of liquid, vapor & condensate pipes and repairing of same to bring it in original decor. |
| 264 | 34.9 mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 265 | 28.5/31.8 mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 266 | 22.2/25.4mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 267 | 19.1 mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 268 | 15.86 mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 269 | 12.7 mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 270 | 9.5 mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 271 | 6.4mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 272 | Supply, Lifting, shifting, positioning, installation, testing & Commissioning of fittings Y-joints/refnets and headers for all Indoor & Outdoor units. |
| 273 | Supplying, fixing, testing and commissioning of Main centralized controller with advanced technology Push Button Type suitable for groups of indoor units to be installed for control (BMS Compatible). All required accessories (hardware and software) to be provided for BMS connection. Controller shall have software for automation (ON/OFF, scheduling, lock/unlock, temperature setting, error detection) of entire system, all indoor units add monitoring of corresponding outdoor units from one central location. Controller should be BMS compatible. It must show the status of all indoor units along with outdoor unit. All required accessories (hardware and software) to be provided for BMS connection. Controller should capable to provide all detail like Fail safe logic. ON/OFF sequencing. Central controller complete with necessary hardware, accessories etc. shall be provided for controlling all the IDUs& ODUs with 15% spare. |
| 274 | INLINE FAN |
| 275 | Supply, installation, testing and commissioning of circular/ rectangular Inline fan for exhaust air with centrifugal blower and motor encased in sheet metal casing, as per specifications. The motor shall be suitable for 220 voltage, 1 phase, 50 cycle AC cycle. All accessories including wire guard, 6/16 Amp plug complete with wiring between the fan and the socket to be provided as required and as per specification. The noise level of selected fan should not more than 50dba @ 3mtr. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 276 | 100 CFM, 8mm Static Pressure |
| 277 | Propeller Fans |
| 278 | Supplying, installation, testing & commissioning of low noise Plastic body circular/rectangular Propeller exhaust fans suitable for following capacities complete with electric motor suitable for operation on 220 V+ 10%, 50 Hz, 1 phase AC supply, 6 Amp plug and wiring between the fan and the socket, fitted with mounting frames, as per specifications of the following capacities. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 279 | 300mm dia |
| 280 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. for TFA unit and inline fans (0.63mm thickness) complete as required. The job also includes piercing of holes , cutting of walls and repairing of same to bring it in original decor. |
| 281 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Duct shall be Al foiled mat finished closed cell Elastomeric Nitrile Rubber of Thermal conductivity of the insulation material shall not exceed 0.037 W/m°K at an average temperature of 20 degree C. Density of the nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of -40 degree C to 105 degree C. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6: 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapor permeability shall be not less than 0.024 per inch i.e. μ>7000: Water vapor diffusion resistance). |
| 282 | 19 MM thick |
| 283 | DUCT ACOUSTIC: - Supplying and fixing of 15mm thick of Acoustic Insulation Inside the Duct with Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 & shall be fibre free. The material shall have a thermal conductivity not exceeding 0.047 W/m.K @ 20 Deg. C & shall conform to Class 1 rating for surface spread of Flame in accordance to BS 476 Part 7. The insulation shall pass Air Erosion Resistance Test in accordance to ASTM Standard C 1071-05 (section 12.7), from an independent testing agency & should have built-in Ultra-Fresh Anti-Microbial Protection, and should pass Fungi Resistance as per ASTM G21 & Bacterial resistance as per ASTM 2180. To be applied using Adhesive. |
| 284 | Supply and Installation of 2Hr. Fire Resistant Fabric Flexible Connection to be installed between all the IDU and the ducting to provide flexibility of movement in case of a seismic event and to prevent transmission of vibration from the unit to the duct. |
| 285 | Supply, Installation, Testing and commissioning of plenum box made from galvanized sheet steel (min. 22G) and is supplied self-finish. Plenums are manufactured with a 15mm internally formed flange at each end, Plenum box comprises a casing with horizontal circular spigot for duct connection, with spigot mounted perforated trimming damper adjustable through front face complete as required . The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 286 | Supply, installation, testing of extruded aluminum powder coated linear grill with volume control damper .100 MM |
| 287 | Supply, fixing and commissioning of Fresh/ exhaust air louvers with section comprising of powder coated Aluminum louvers & bird screen as required. |
| 288 | Supplying, fixing testing commissioning of supply/return air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring & removable core. |
| 289 | Transmission and Control CableProviding & fixing control cum transmission wiring in medium duty PVC Conduit between indoor and outdoor units.2C x 1.5 Sqmm Cu Cable |
| 290 | Cable Tray: - Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required |
| 291 | 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. |
| 292 | 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. |
| 293 | 300 mm. Width x 50mm. Depth x 1.6mm. Thickness. |
| 294 | Design, Supplying, installation, testing & commissioning of cubical type floor mounted power distribution panels suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type FP Aluminum Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 3 MV A for I Sec. with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm.Incomer1No. 200 Amps,36 kA Four Pole, MCCB with thermal & magnetic releases. With 3 Nos. R, Y, B Indication Lamps with 2A back up SP MCB with ON indication. Busbar: aluminum bus bars of minimum of 250 A capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc.Outgoings:Supplying and fixing following outgoing MCCB/MCB including connection, inter connection etc. with suitable size of wires complete as required. 63 Amp 4P MCCB with RCCB (along with SPP) for each ODU and 63 Amp 4P MCCB for each floor of the building to be connected to sub panel in each floor. The panel is to be provides with OLR, Earth fault relay, phase reversal and phase loss protection. It also includes Providing and fitting of Sub-Panel Boxes (floor wise) with 63 A 4P MCCB 1 No, 6A DP MCB for each indoor unit including digital voltmeter as per the no. of indoor units with indication lamps duly fitted on wall in each floor for indoor units.10A DP MCB for each inline fan and TFA units. |
| 295 | CABLE |
| 296 | Supply, laying testing and commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper conductor cable of 1.1 KV grade on existing cable tray / surface including making end termination with brass compression glands and Al. lugs clamps, ties etc. as required. |
| 297 | 4 Core 16 Sqmm+2Core 6Sqmm. |
| 298 | 3 Core 1.5 Sqmm+1 Core 4 Sqmm. |
| 299 | 3 Core 1.5 Sqmm+1 Core 4 Sqmm. |
| 300 | Supplying ,Laying and Testing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/Cable Tray as required. |
| 301 | 3.5C x 95 mm² LT XLPE (A2XFY) aluminum |
| 302 | Supplying and making end termination with brass compression glands and Al. lugs for following size of PVC insulated and PVC sheathed / XLPE Al. conductor cable of 1.1 KV grade as required. |
| 303 | 3.5C x 95 mm² LT XLPE (A2XFY) aluminum |
| 304 | EarthingP/F of Maintenance free Chemical Earthing using GI Electrode of size 60 mm dia, 03 meter long connected with 4OX5 mm GI internal strip complete with excavation, civil works, cast iron cover with back fill compound along with 50 kg bag of Back fill compound/SOR Compound (highly conductive, non corrosive moisture retaining chemical) complete. |
| 305 | Supplying and laying 25 mm X 5 mm GI strip as strip to earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. |
| 306 | Drain Pipe(CPVC)Supply & fixing of heavy duty CPVC/PPR Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness of closed cell nitrile rubber/ EPDM insulation as required & as per specifications. |
| 307 | 25mm dia |
| 308 | 32mm dia |
| 309 | Providing and laying of RCC foundation block in 1:2:4 mix for installation of outdoor units. The job includes cost of account of shuttering and all tools and tackles required during the job (as per drawings provided during execution) |
| 310 | CMC DETAILS 1ST Year DLP |
| 311 | CMC for 2nd year |
| 312 | CMC for 3rd year |
| 313 | Note: Shop drawings for VRF machine locations and Duct layout, refrigerant and drain Piping layout, Electrical panel design and location, location, cable tray and cabling routes. The Drawings need to be approved by third-party to be nominated by the Division. |
| 314 | Fire fighting system |
| 315 | PIPES & ACCESSORIES |
| 316 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling, undeground (excavation work as well) along with damping insulation with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 317 | 25 mm dia |
| 318 | 80 mm dia |
| 319 | 100 mm dia |
| 320 | 150 mm dia |
| 321 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 322 | Single headed stainless steel |
| 323 | Supplying and fixing orifice plate made out of 6 mm thick Stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 324 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 325 | Stainless Steel (Grade 304) |
| 326 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 327 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 328 | 2way - 100 mm dia M.S. Pipe |
| 329 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 330 | TERRACE TANKFabrication installation,testing and commissioning of water priming tank (Fire Tank) to be fabricated out of M.S sheet of thickness 6mm and of capacity 5000Ltrs which shall be installed above fire pumps and connected with the suction header of the fire pump. The tank shall be placed over suitable structural steel stand to be fabricated out of ISA 65x65x6mm and ISMC 100 as required. The job further includes finishing with epoxy paint,internal epoxy paint(primer + 2 coats), synthetic enamel paint on steel (external ,primer +2 coats) . The job also includes necessary installation of sockets, isolation valves and suitable locking arrangement and making necessary holes along with nozzels for inlet, outlet , overflow , manhole with cover (welded) and drain pipes with fittings and connection with suction line of pump |
| 331 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 332 | Stainless Steel (Grade 304) |
| 333 | Providing and fixing Weather proof hose cabinets for yard hydrant fabricated from 16 g MS sheet and MS angle with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No short branch pipe,1 no first aid hose reel,extinguisher,pressure guage and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m or as per arch). |
| 334 | Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete. |
| 335 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 336 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325.(c) M.S.fabricated common base plate, coupling, couplingguard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plasteredand with anti vibration pads. |
| 337 | 450 lpm at 35 m Head |
| 338 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved SLD |
| 339 | INCOMERMCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with |
| 340 | Digital Metering Devices, comprising Voltmeter, Ammeter, Selector |
| 341 | Outgoings: |
| 342 | MPCB 19-25 A With STD. Magnetic Release |
| 343 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 344 | Start/Stop Push Button |
| 345 | Size of wiring for CTS:- 2.5 sqmm |
| 346 | Size of wiring for voltage sensing Metering :-4.0 Sq.mm |
| 347 | Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm |
| 348 | Types of wires:-PVC insulated 1100V grade, Multistrand copper conductor Flexible FR-LSH |
| 349 | Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire. |
| 350 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet |
| 351 | Gland Plates to be 3.0 mm Thick. The job also includes providing & laying of copper electric cabling from terrace panel to pump. |
| 352 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 353 | 150 mm dia |
| 354 | 50 mm dia |
| 355 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 356 | 150 mm dia |
| 357 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 358 | 150mm dia |
| 359 | Supply, Installation, testing and commissioning of pressure switches for Fire Pumps, diaphragm type, adjustable range from 0-5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. |
| 360 | Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 . |
| 361 | Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 . |
| 362 | Providing and fixing proprietary polyshield outermechanical protection on nitrile rubber insulationcomprising of Wrapping with polyglass tape helically wound and subsequently applying 2 coats of polyshield material (resin and hardener) as per manufacturers specifications and approved by site incharge. |
| 363 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683) .Complete with all accessories |
| 364 | Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 6 Kg. Capacity fully charged,ISI Mark(IS:15683)suitable for Class A/B/C Type Fires .complete with all accessories |
| 365 | Supplying,Installation,Testing and Commissioning of water Type Fire Extinguisher 9 ltr. Capacity,fully charged , ISI Mark(IS:15683) stored pressure .Complete with all accessories |
| 366 | Fire Alarm system |
| 367 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system includingconnections, interconnections etc complete as required.6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No.Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 368 | Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with allconnections etc. as required. |
| 369 | Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired. |
| 370 | Supplying, installation, testing & commissioning of manual callboxes of MS construction in surface/recess with stainless steelchain & hammer assembly complete with glass and push buttonetc. as required. |
| 371 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required |
| 372 | 3 x 1.5 sq. mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail