Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing lifting, hoisting and laying R.C.C. of M-20 Grade to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge. |
| 2 | a) Pantry /Kitchen/table top slab |
| 3 | a) Column base for lift |
| 4 | b) RCC Wall for lift |
| 5 | c) Beam for lift |
| 6 | First Floor |
| 7 | Second Floor |
| 8 | d) Roof slab for lift |
| 9 | Second Floor |
| 10 | Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-Charge.(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor) |
| 11 | Ground Floor |
| 12 | First Floor |
| 13 | Second Floor |
| 14 | Fly Ash brick masonry in cement mortar (1:6) using Fly Ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 15 | First Floor |
| 16 | Second Floor |
| 17 | Providing 16mm thick Cement Plaster (1:6) on the rough surface of masonry walls for all floors including racking and joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 18 | First Floor |
| 19 | Second Floor |
| 20 | Third Floor |
| 21 | Providing 12mm thick Cement Plaster (1:6) on the rough surface/ plumbed surface of masonry racking out of joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and level and providing grooves as shown in the drawning including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. |
| 22 | First Floor |
| 23 | Outside Second Floor |
| 24 | Third Floor |
| 25 | Inside Second Floor |
| 26 | Providing 6 mm thick cement plaster in cement mortar of mix (1:4) at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and all taxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge. |
| 27 | Second Floor |
| 28 | Third Floor |
| 29 | Priming one coat to wall surface with water bound cement primer including cost of the primer with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect. |
| 30 | Ground Floor |
| 31 | First Floor |
| 32 | Second Floor |
| 33 | Third Floor |
| 34 | Finishing wall surface of walls with Acrylic Groove textured finish (2 to 2.5mm thick) of approved make and finished rough surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete |
| 35 | Second Floor |
| 36 | Third Floor |
| 37 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. |
| 38 | Second Floor |
| 39 | Third Floor |
| 40 | Painting two coats with plastic emulsion paint with a approved quality to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 41 | Ground Floor |
| 42 | First Floor |
| 43 | Second Floor |
| 44 | Third Floor |
| 45 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 46 | Ground Floor |
| 47 | First Floor |
| 48 | Second Floor |
| 49 | Third Floor |
| 50 | Providing & Painting with synthetic enamel paint of approved brand and manufacture over a coat of primer to give an even shade as per the including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Ground floor instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. |
| 51 | Second Floor |
| 52 | Third Floor |
| 53 | Providing fitting and fixing of false ceilings with Aluminium anodised T Section No. 3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 6'-0\\"x4'-0\\" with Gypsum board suspended from ceiling etc complete |
| 54 | Supplying, fitting and fixing Granite tile above 0.40 sqm. (20mm thick) laid on 20mm thick C.M (1:4) including filling / grouting and finishing laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 55 | Supplying, fitting and fixing Granite tile above 0.40 sqm. (20mm thick) in dado/ skirting,riser of steps,wall on on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 56 | Supplying, fitting and fixing vitrified tile in floors of size 600mm x 600mm coloured / printed series of approved make of premium grade having thickness 8mm to 10mm conforming to IS-13756 on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects. |
| 57 | Supplying, fitting and fixing Vitrified tiles in Size of Tile 600x600 mm colour/printed) in dado/ skirting,riser of steps,wall on on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. |
| 58 | Providing and laying Vitrified tiles in floor with Size of Tile 600mmX1200mm (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).(DAR 2023 Vol.I ,Cl 11.49.4 Pg.839) |
| 59 | Providing and laying anti skid vitrified tile in floor with size of tile 600x600mm printed/coloured (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).(DAR 2023 Vol.I ,Cl 11.49.2 Pg.838) |
| 60 | Providing and laying vitrified tiles 600mmx1200mm (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).DAR 2023 Vol.I ,Cl 11.47.4 Pg.835 |
| 61 | Grouting the joints of flooring vitrified tile 600x600mm having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resinper kg), including filling / grouting and finishing complete as per direction of Engineer-incharge.(DAR-2023 Vol-1 Clause No-11.48.2(pg-836)) |
| 62 | Grouting the joints of flooring vitrified tiles 600mmx1200mm having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-incharge.(DAR-2023 Vol-1 Clause No-11.48.3(pg-836)) |
| 63 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat/square/round conforming to IS 2062/2006 painted with Red Oxide Primer as per the design approve by E.I.C including cost,conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 64 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made : Frame size- 65*125 mm(DAR Cl. 26.86.6) |
| 65 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made : Frame size 45 x 85 mm (DAR Cl. 26.86.2) |
| 66 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete |
| 67 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 30 mm thick of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainlesssteel butt hinges and necessary S.S screws shall be paid separately) (DAR 2023 vol-1,Cl 26.88, pg-2037) |
| 68 | Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (DAR 2021 vol-I Clause No-9.147.D, pg no.516 )Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). (DAR 2021 vol-I Clause No-9.147D.4, pg no.518) |
| 69 | Providing and fixing factory made UPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) (DAR 2021 Clause No-9.147F.4) |
| 70 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areasof the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2,+ 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(DAR 2023 vol-II,Cl 25.3, pg-1899) |
| 71 | Fixed window / ventilator without mullion / transom. :Using R1 series with frame (33mm & above ) x (35mm & above). (Height upto 0.90 metre)including cost ,conveyance of all materials with all labour and T&P required for the work complete in all respect as directed by Engineer- In- Charge. |
| 72 | Supplying , fitting and fixing of stainless steel of 304 grade in hand railing using 50 mm dia of 2 mm thick circular pipe with Balustade of size 32mm*32mm*2mm @ 0.90 mtr C/C and stainless aquare pipe bracing of size case as per approved design and specification, buffing, polishing ete. with the cost,conveyance taxses of all materials ,cost of all labour ete.complete in all respect.(in all floor) |
| 73 | Providing & Fixing of Louvers panelling made out of 19mm thick BWP plywood with 2\\" batten as support in Horizontal and Vertical Member Placed @ 600 mm C/C and 12mm thick wpc Louvers sheet , All exposed edges should be covered with 1mm thick decorate laminate, including cost of all materials, Labour T&P etc as per direction of Engineer-In-Charge. (Louvers Panel sould be pre approved by Engineer-In-Charge) |
| 74 | Providing & Fixing Setup box stand having size (6'2\\"Lx6\\"H X 1'D) made out of 18mm BWP Ply. One side hanged with necessary hidden brackets and other side supported with 18mm ply as side panel. All exposed surfaces to be laminated with 1mm thick decorative lamination (Textured), including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 75 | Study table @ 3'4\\"Lx1'6\\"Wx2'6\\"HTProviding & Fixing of study table of size 3'4\\"Lx1'6\\"Wx2'6\\"HT, TOP and sides of table to be made of two 18 mm thick BWP Ply sandwiched together and back to be supported with single 18mm BWP ply. All exposed surface to be laminated with 1mm thick decorative laminates (Textured). One drawer of size 1'6\\"(W) x 7'(H) x 1'3\\"(D) should be provided made of 18mm thick prelam BWP ply with decorative laminate, soft close channels, concealed handle etc, including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 76 | Trolley bag stand 2'8\\"Lx1'10\\"Wx1'8\\"HT Providing & Fixing of Trolley bag stand of size 2'8\\"Lx1'10\\"Wx1'8\\"HT- made up of, Top and sides with two layer of 18mm thick BWP Ply laminated with 1 mm thick decorative laminates (Textured) in all exposed side, including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 77 | Mirror Unit @ 3'7\\"L X 7'5\\"H Providing & Fixing Mirror Unit of size 3'7\\"L X 7'5\\"H, made up of 6mm thick belgium mirror pasted on 18mm thick BWP Plywood with outer side 1mm thick decorative laminate (Textured). All exposed edges to be sealed with 1mm thick PVC edge banding including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 78 | King Size Bed @ 6'X7'Providing and fixing Bed of Size 7'Lx6'Wx10\\"H with BWP(710) Ply of size 18mm make Marino/ Century /Archidply etc. Top ply should be supported with vertical supports @ 600 mm C/C with 18mm Plywood and side panel should be raised to restrict the movement of Matress. All Inner Side of the Bed should be laminated with 0.6 mm white laminates & outerside with 1mm decorative laminate (Textured) of make Marino/Century/Archidply. All exposed edges to be sealed with 1mm thick PVC edge banding including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 79 | Padding @ 6'X7'6\\"Providing & Fixing of Padding in headrest for Bed of size (6'x7') made out of 18mm BWP Ply as base support and 12mm ply as per drawing/design of padding. The Padding to be made of Sleepwell foam of 75mm thick having density not less than 28 kg/cum with fabric of make De decor, with necessary silver/gold metal strips as per drawing and design including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 80 | Wardrobe 4'WX 7'HX 1'10\\"DProviding and Fixing slidding door Wardrobe of size 4'LX 7'HX 1'10\\"D with 18 mm thick BWP ply of Make Marino/ Century /Archidply etc, Top, bottom,side panels and Shelve are to be made up of 18mm BWP Ply and back support with 12mm thick BWP ply with all inner side 0.6 mm white laminates and outer side 1 mm decorative laminate (Textured) make Marino/ Century /Archidply . The Door to be made up 18 mm thick block board of make Marino/ Century /Archidply with necessary slidding arrangements make Hettich/Hafele and concelaed handle. One drawer of size 1'6\\"(W) x 7'(H) x 1'10\\"(D) should be provided made of 18mm thick prelam BWP ply with decorative laminate (Texture), soft close channels, concealed handle etc. Aluminum hanger rod of 25mm dia with brackets, All exposed edges to be sealed with 1mm thick PVC edge banding including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 81 | Side Table @ 1'10\\"LX1'4\\"HX 1'3\\"D Providing and Fixing Bed Side Table of size 1'10\\"LX1'4\\"H X 1'3\\"D, with All sides, Drawers and horizontal partition to be made up of 18mm BWP Ply with outer side 1mm thick decorative laminate (Textured) and inner side 0.6mm thick white laminate, The drawers should be provided with Soft closing channels of make Hettich and concealed handle including all cost of materials, T&P, all labour etc complete as per the Direction of Engineer in - charge. |
| 82 | Supplying and fixing of Roman blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 1 mm thick fabric with lining of approved design and quality etc. complete. |
| 83 | Providing and fixing 18 mm thick, 150 mm wide pelmet of BWP ply fitted with L bracket of size 100 x 100x 6 mm to hold the pelmet fitted at 650 mm c/c with anchor bolt to rcc surface and fitted M-track of Marvel make with all required accessories inside the pelmet for hanging curtain including cost of all material,labour,T&P,etc. complete as per direction of engineer in charge . |
| 84 | Supply & installation of Main Curtains & Sheer Curtains with Lining on Main & Tailoring Charges including cost of all labour, T&P, lead etc. complete as per direction of Engineer in Charge. |
| 85 | Providing and Fixing of wall paper of aesthetic design and good quality etc. including cost of all labour, T&P, lead etc. complete as per direction of Engineer in Charge. |
| 86 | Fixing chowkhat (Anchor Bolt) in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. |
| 87 | Providing & Fixing of leaping made out of 19mm thick BWP plywood , All exposed edges should be covered with 1mm thick decorate laminate, including cost of all materials, Labour T&P etc as per direction of Engineer-In-Charge. |
| 88 | Dismantling and removing RCC columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50M lead including cost of all labour, T&P, lead etc. complete as per direction of Engineer in Charge. |
| 89 | Bore Packing (4\\"-8\\")Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene- butadiene based polymer coating using Latex. Packing the gap using non-shrink cement polymer based grout up to the surface of the bore whilst the Latex is in tacky state seal the Bore with polyurethane Sealant, ,including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Latex :- Fosroc -Nitobond SBR/ Myk -AquaArm latex 45/ Sika- Sika Latex power , Polymer based grout::- Fosroc- Renderoc RGL / Myk- Laticrete 3DCP-M30 / Sika- Sika ceram-500TG) |
| 90 | Cement Concrete covingProviding Coving at all the junctions for a size of 50mm X 50mm with polymer modified mortar prepared by mixing 50 kg cement + 150kg Sand + 4Litre of Latex + Water required for mortar consistency, including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Latex :- Fosroc -Nitobond SBR/ Myk -AquaArm latex 45/ Sika- Sika Latex power) |
| 91 | Polyurethene(PU) Coating of 1.5mm thick Provinding & applying the surface with primer & Providing two coats of liquid applied, solvent-free elastomeric waterproofing membrane, shall be made of hydrocarbon free polyurethane with at least 85% solid content Nitoproof 600PF with necessary surface preparation, coving, primer etc. The waterproofing membrane shall be terminated on the top of parapet walls. including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Primer :- Fosroc - Nitoproof WB / Myk -FloArm primer PU/ Sika- Sikalastic PU Primer, Polyurethene :- Fosroc - Nitoproof 600 PF / Myk -AquaArm WPU 1K(E) / Sika- Sika guard 7600 VG) |
| 92 | Geo Fabric MembraneProviding and laying Geo fabric Membrane 150 Gsm, non woven, 100% polyester of thickness 1 to 1.25 mm to act as separation layer before screed concrete including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Sika- Sika plan WP 1100-22 HL) |
| 93 | Grading Concrete (1:1:2) mm thick Providing and applying protective Grading concrete of avg 50 mm thickness above Geo fabric membrane The concrete shall be admixed with intergal based water proofing and finishing surface suitably, curing, cleaning, testing etc. The concrete shall be cut with paneel the 2m x 2m up to depth 1/3 th of depth and the groove shall be filled with Polyurethene sealant including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Admixture :- Fosroc - Nitoseal PU50/ Myk -AquaArm Proof WP 10/ Sika- Sikanoleek) |
| 94 | Plaster Providing and applying average 12 mm thick single Coat cement sand plaster of mix ratio 1:4 (1 cement: 4 sand) including adding admixture @ 200 ml per bag of cement, finished smooth finish or as required to receive specified finish to correct line, plumb and level to the structure, including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Admixture :- Fosroc - Conplast WL Xtra/ Myk - AquaArm admix/ Sika- SikaControl AER-200 P) |
| 95 | Supply and apply of Brushbond TI Flexicoat or equivalent - single component, Water based High thermal reflectance & emittance coating over the Screed Concrete surface@300micron DFT in two coat at a coverage 2.5 - 3.0 m2/Litre .The material should have the ability toreflect the visible, infrared and ultraviolet Adhesion Strength :transfer to the building / structure which significantly lowers thesurface temperature of the roofs and structural exteriors. Tensile strength at break (ASTM D412): 1-1.5 MPa, Elongation at break: 100%, Shore A Hardness: 45 - 55, Q-UV accelerated weathering (3000 Hrs) - No evidence of cracking, deterioration & loss of fl exibility including termination etc. as per manufacturer direction. Item rate is inclusive of materials all labour, tools and tackles, surface preparation and cleaning of concrete surface, and transportation etc. complete as per specification and as directed by EIC. |
| 96 | Supply and installation of Stretch wall fabric system by using FR Grade acoustic fabric of size 1700mm width, shall be stretched by using wooden base 12.5 mm thick, rigid vinyl Stretch Tracks half wrap/full wrap 12.5mm and Midseam 12.5mm, Strand wood wool board , Infills polyester fibre infill with requisite accessories & tools. Wooden base 12mm is first installed on the wood fibre along the marking lines with metal fasteners inserted at 300mm centres. 12.5 mm tracks to be installed on wooden base, after applying Stick adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of Stretch Tracks. The GI strut system includes GI Cross channel having thickness 0.45mm, length 3600mm, knur led web 40mm, depth 25mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centres. Strand Wood Wool Board is square edge magnesite bonded pinewood fibre panels of size 600x1200x25mm having density 400kg/m3, weight 4kg which is fixed to Cross Channel 25mm. Long edge of panels should be perpendicular to length of Cross Channel , Infills polyester fibre infill 1000gsm 25mm thick adhered on Strand Wood Wool Board panel by using adhesive. Fabric of width 1700mm is then aligned to the Stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module wall fabric width would be 1600mm. Technical Parameters: • Core – Pine wood fibre & Poly fibre • Fire – Class A • Acoustics – NRC 0.90 • Climate (OC RH) – 55, 90 • Termite resistance – Yes • Light reflectance – Colour dependent • Green (RC %) – Low, 10 inatallation as per direction of EIC.(Make-Armstrong/Hunter Douglus/Anutone) |
| 97 | Providing & Fixing of Fibre Glass Acoustical Suspended Ceiling (600MMX600MM) 90 Edge Tiles with 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 20/25mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%.INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum.(Make-Armstrong/Hunter Douglus) |
| 98 | Providing and laying of green certified carpet tiles thickness more than 5.5mm size 50X50 cm with nylon content of 100% Tufted Textured loop pile, manufacturer using latest dyeing technology. The backing has to be non pvc backing. Tufted Pile Weight Standard 14.8 oz. per sq. yd. with antistatic, thermal resistance , sound insulation & sound absorption properties. Carpet to have fire resistance of Cfl-s1 ( with adhesion) and suitable for allergies. Product to have classification of use should be 33 commercial heavy use. The product has to be 100% recyclability with Environmental product declaration & material health statement certificate for sustainability. The product should have CRI green certified product. Rates including complete installation with backing foam, necessary stitching etc. The floor which receives the carpet to be thoroughly cleaned as per manufacturers specification. The carpet is to be laid over a bed of manufacturers approved adhesive (with VOC limit 50g/Ltr) of Arobond 44 of Colourbond Mktg. / VC 31 of Pidilite Ind) spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer in PVC or HDPE sheet of 500 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover / on commissioning. If after the protective layer is removed and stains observed in the carpet because of inadequate protection, the same shall be shampooed and made good to the satisfaction of the project managers. The measurements of carpet will be the actual laid area.(Make-Well spoon/ Square Foot) |
| 99 | Supply & installation of Slats in wall panelling are made of pinewood E1 grade fiberboard, Melamine laminated finish, groove perforated slats L16-3/L23-3/L32-3/Customized - (3mm grooves Slats @16mm centres) back lined with black acoustical fleece, tongue-groove edge for a seamless look, of size 192 & 128x2440x15/17mm thick having base density 700Kg – 800 Kg/m3, weight 12Kgs/m2 installed by using GI strut system. The GI strut system includes GI Cross channel having thickness 0.45mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centres. Aluminium core cross channel (CC18) having thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & centre brackets is then fixed perpendicular to the CC25with the help of fasteners at every 400mm centres. Slats of size 192 & 128x 2430x15/17mm in then fixed perpendicular to CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 5mtrs both ways. Panels shall be back lined with acoustical infill of 1000gsm x 50mm thick adhered to the wall using Stick adhesive Technical Parameters: • Core Variants – Wood Core E1 Fibreboard • Fire – Class A • Acoustics – NRC up to 0.75 • Climate (OC RH) – 50, 70 • Green (RC %) – 25 • Strength, Load capacity (Kg) - Ball-Impact inatallation as per direction of EIC. (Make-Armstrong/Hunter Douglus/Anutone) |
| 100 | Providing and Fixing of conference hall table with 19mm thick BWR ply board and 6mm thick Corian sheet of make Marino/Century ply/Greenply etc. including cost of all labour, T&P, lead etc. complete as per direction of Engineer in Charge. |
| 101 | Providing and supplying a high back chair with ergonomic design, comfortable & aesthetically appealing. The seat and back shall be made of 18mm thick hot pressed BWP plywood padded with high resilience polyurethane foam 50mm thick having density 40kg/m³ in seat and 40mm thick having density 32kg/m³ in back. The same shall be upholstered with leatherite tapestry 0.8mm thick and 535 GSM. The backrest shall be made by keeping the natural curvature of the spine which helps to provide lumbar support. The chair shall be supplied with PP arm with cushion having leatherite covering top pivot joint with back. For seating durability the chair shall have knee tilt 360 degree revolving mechanism having four position locking and tilt tension adjustment with anti-shock feature which provides back strength for the chair. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 65mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The Pedestal should have five legged Polypropylene base with chrome having pitch circle dia. 700 mm fitted with 5 nos. twin wheel castors. The castors of the chair should be injection moulded in black 30% glass filled nylon, confirming to ANSI/BIFMA standards X5.1-2011 tested to perform 98,000 cycles with 250lbs load. The seat size shall be 510±10 mm(D) X 570±10 mm(W) and back size shall be 550±10 mm(W) X 670±10 mm(H) from seat. Overall height shall be = 1130±10 mm, overall depth = 690±10 mm & overall width = 700±10 mm. Make- Godrej/featherlite/Geeken/wipro |
| 102 | Providing and supplying high back chair with ergonomic design, comfortable & aesthetically appealing. The seat shall be made of 18mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam 50mm thick having density 40kg/m³ with foam net tapestry 0.9mm thick and 300 GSM and the back shall be made of injection moulded polypropylene net cover upholstered with breathable mesh tapestry. The backrest of the chair shall be made by keeping the natural curvature of the spine with adjustable lumbar support. The chair shall be supplied with injection moulded PU adjustable arm completely joint with seat. For seating durability the chair shall have ACTICE BIO-SYNCHRO mechanism with upright position locking and tilt tension adjustment. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 100mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The Pedestal should have five legged made of die cast aluminium having pitch circle dia.. 700 mm fitted with 5 nos. twin wheel castors. The castors of the chair should beinjection moulded in 30% glass filled nylon, confirming to ANSI/BIFMA standards X5.1-2011 tested to perform 98,000 cycles with 250lbs load. The seat size shall be 520±10 mm(W) X 500±10 mm(D) and back size shall be 495±10 mm(W) X 750±10(H) from seat & overall height = 1150±10 mm. Make- Godrej/featherlite/Geeken/wipro |
| 103 | Providing and supplying mid back chair with ergonomic design, comfortable & aesthetically appealing. The seat shall be made of 18mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam 50mm thick having density 40kg/m³ with foam net tapestry 0.9mm thick and 300 GSM and the back shall be made of injection moulded polypropylene net cover upholstered with breathable mesh tapestry. The backrest of the chair shall be made by keeping the natural curvature of the spine with adjustable lumbar support. The chair shall be supplied with injection moulded PU adjustable arm completely joint with seat. For seating durability the chair shall have ACTICE BIO-SYNCHRO mechanism with upright position locking and tilt tension adjustment. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 100mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The Pedestal should have five legged made of die cast aluminium having pitch circle dia.. 700 mm fitted with 5 nos. twin wheel castors. The castors of the chair should beinjection moulded in 30% glass filled nylon, confirming to ANSI/BIFMA standards X5.1-2011 tested to perform 98,000 cycles with 250lbs load. The seat size shall be 520±10 mm(W) X 500±10 mm(D) and back size shall be 495±10 mm(W) X 750±10(H) from seat & overall height = 1050±10 mm. Make- Godrej/featherlite/Geeken/wipro |
| 104 | Providing and supplying 4 Seater Dining Table (with chairs) made up of Teak Wood having ONYX marble Top with Melamine Finish: The understructure is made of teak wood and consists of a melamine finish. The table top carrying maximum capacity of 56000 Grams weight. Item dimensions (L x W x H) 149.9 x 89.9 x 254 Centimeters. Make- Godrej/featherlite/Geeken/wipro or equivalent |
| 105 | Supplying & Placing Cafeteria Chair. The seat shall be made of 12mm thick hot pressed plywood upholstered with high resilience polyurethane foam 25mm thick having density 40kg/m³ in seat and 25mm thick polyfill in back with velvet tapestry 0.6mm thick and 235 GSM. The frame structure shall be supported by four legs made up of SS 202 grade gold plated reducing leg. There shall be PPCP shoe provided at the base to avoid scratches on the floor. The seat size shall be 420±10 mm(D) X 480±10 mm(W) and back size shall be 500±10 mm(H) from seat. Overall height shall be = 800±10 mm. Make- Make- Godrej/featherlite/Geeken/wipro or equivalent |
| 106 | Supplying & placing cafeteria table with an overall size 450mm X 450mm. The top of the table shall be made up of vertified tile with gloss finish having 50mm thickness with SS 304 grade frame. The profile of the table shall be in round shape. The basic under structure shall be made up of SS 304 grade 70mm x 8mm thick with matt finish . The Joints shall be made by using TIG welding. The under structure shall be buffed for obtaining shiny finish. There shall be PPCP shoe provided at bottom to avoid scratches on the floor. The manufacturer shall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007 certification. Make- Godrej/featherlite/Geeken/wipro or equivalent |
| 107 | Providing and supplying single seater sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam having density 45Kg/m³ in seat and 32Kg/m³ in back. The backrest of the sofa shall be supplied with traditional tufted buttons with decorative appealing. There shall be cushion arm provided padded with high resilience polyurethane foam having density 32Kg/m³. The complete structure shall be upholstered with leatherite tapestry 0.8±0.1 mm thick and 535 GSM. The understructure shall have SS 202 grade with shiny chrome finish frame having thickness 12mm. There shall be buffers provided at the bottom to avoid scratches on the floor as well as uneven surfacing. The seat size shall be 670±10 mm(W) X 620±10 mm (D) X 430±10 mm (H). Overall width = 1270±10 mm, overall depth = 1000±10 mm & overall height = 740±10 mm. Make- Godrej/featherlite/Geeken/wipro or equivalent |
| 108 | Supplying and placing a three seater sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam having density 45Kg/m³ in seat and 32Kg/m³ in back. The backrest of the sofa shall be supplied with traditional tufted buttons with decorative appealing. There shall be cushion arm provided padded with high resilience polyurethane foam having density 32Kg/m³. The complete structure shall be upholstered with leatherite tapestry 0.8±0.1 mm thick and 535 GSM. The understructure shall consist of SS 304 grade leg with shiny chrome finish having thickness 12mm. There shall be buffers provided at the bottom to avoid scratches on the floor as well as uneven surfacing. The seat size shall be 2000±10 mm(W) X 620±10 mm (D) X 430±10 mm (H). Overall width = 2600±10 mm, overall depth = 1000±10 mm & overall height = 740±10 mm. Make- Godrej/featherlite/Geeken/wipro or equivalent |
| 109 | Providing and supplying centre table with an overall size 900mm X 900mm X 410mm. The top should be made up of 75mm thick, it would be 25mm at mid and 75mm at sides. The MDF top should have decorative finish with approved veneer and PU polish accordingly. The understructure shall consist of 4 nos. of MS sheet gold leg with 6mm thick. Make- Godrej/featherlite/Geeken/wipro or equivalent |
| 110 | \\"Supplying, fitting and fixing 25 cm thick Mattress of Make Sleepwell/Wakefit/Century of size (182.9 X 213.4 cm) with following specifications 1. Premium knitted fabric in box top finish should be tear resistance and easy to maintain. 2. Impression foam for enhanced contour hugging comfort and surface feel. 3. Smart recovery memory foam that adopts to the contour of body movement 4. 3-zoned resitec profile system that offers support, even pressure distribution and ventilation. 5. Individual pocket springs for best responsive spinal support 6. Side seating support foam layer. 7. Bottom air mesh fabric supports free movement of air Including cost of fitting and fixing, including all lead, lifts, T&P etc as per direction of Engineer In Charge. (Mattress should be Pre approved by Enginner In Charge) |
| 111 | ELECTRICAL WORKINTERNAL ELECTRICAL WORKSub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.N.B: 2way switch shall be used for living room for controlling room light and fan adjacent to bed. |
| 112 | GROUP-A |
| 113 | GROUP-B |
| 114 | GROUP-C |
| 115 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 116 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 117 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 118 | Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 119 | Supplying,fixing of 2x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+2 no 6A switch & socket(modular type) ( anti-bactorial and flame retradant type) with suitable size modular box & metallic cover plate (both side)( anti-bactorial and flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-Next gen)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 120 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 121 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 122 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 123 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(UDB TO USB) (2X6+1X2.5) |
| 124 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB/PDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 125 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 126 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 127 | Sub-Head II (Light fitting Fixture & Fan) |
| 128 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 129 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 130 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand (Myrius) /Schneider(Zencelo)/Panasonic(Vision) |
| 131 | Supplying and fixing of Energy efficient surface /recess mounted round shape 6 W LED spot luminaire of dimension of consists of white powder coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution and lumen output of 660 lumens, CRI not less than 80,CCT of 6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.( TO BE USED FOR LIVING ROOM ,BED ROOM,MEETING ROOM AND CONTROLLED BY GROUP WIRING )(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 132 | Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 133 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years(for sma |
| 134 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 135 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 136 | Supply and Installation of 1x 9Watt LED decorative copper galss pendant light including all the connections and accessories as required. (Make- Havells/ Philips/ Jaquar/ Crompton) |
| 137 | S/F of 24 W 3000 K Flexible led strips with uniform light distribution and long lasting adhesive for perfect cove lighting solution including all connections and accessories. (Make- Havells/ Crompton/ Philips) |
| 138 | Supply & fixing of 5watt Wall Decorative LIGHT opal glass with all accessories as per the direction of Engineer-in-charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 139 | Supply, installation, testing and commissioning of 15 litre, 2000W storage type electric water heater complete with copper heating element, glass-lined tank, thermostat, safety devices, electrical and plumbing connections as required.. (Make- Havells/ V-Guard/ Bajaj) |
| 140 | Supply, delivery, installation, testing and commissioning of 90 litre capacity, direct cool, single door refrigerator, having minimum 1 Star BEE energy rating, operating on 230V, 50Hz single phase supply, complete with hermetically sealed compressor, adjustable thermostat, toughened glass shelves, door gasket, interior lighting, manual defrost system, and all standard accessories, including initial warranty as per manufacturer specification.. (Make- LG/ Samsung/ Voltas) |
| 141 | Supply, delivery, installation, testing and commissioning of 242 litre capacity, frost-free, double door refrigerator with smart inverter compressor, having minimum 3 Star BEE energy rating, operating on 230V, 50Hz single phase AC supply, complete with automatic defrost system, adjustable thermostat, toughened glass shelves, large vegetable box, door gasket, interior LED lighting, stabilizer-free operation, eco-friendly refrigerant (R600a or equivalent), and all standard accessories, including initial warranty as per manufacturer specifications, complete in all respects. (Make- LG/ Samsung/ Voltas) |
| 142 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/ Kanex/ Ceasefire/ Flameklog . (4.5 kg capacity) |
| 143 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 144 | Supplying and fixing of 32A MECHANICAL KEY Tag with 32A 2 Moduled Mechanical key tag switch & Electronic key tag etc. as requiredas required as per direction of Engg.-in-Charge.Make-Anchor/Cona/Havells |
| 145 | SITC of PIR based occupancy sensor for corridor , connected load upto 10Amp, mounting height upto 2.8 mtr and 5m diameter coverage in complete as per the direction of Engineer-in-charge. Make-Schneider/Legrand/Siemens/ABB |
| 146 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 147 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 148 | 8 Way(8+12+24) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (for PDB, ) |
| 149 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 150 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.The MCB should be Replacement Warranty will be 1 year. |
| 151 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year |
| 152 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 153 | Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year |
| 154 | Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 155 | Supplying and fixing 40-63Amps 2P 240 volts AFDD(arc fault detection device) Make-ABB S ARC1 M/Equivalent model of Schneider/Legrand/Siemens ,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year |
| 156 | Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-LEGRAND / Siemens/ Schneider/ABB in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 year.(To be used in PDB) |
| 157 | (Earthing) INSTALLATION |
| 158 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 159 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 160 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 161 | CABLING AND END TERMINATION MAIN AREA |
| 162 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 163 | 3.5Core 95sqmm (From Transformer to Main Panel)(One Spare) |
| 164 | 3.5core 50sqmm (From Main Panel to 2nd Floor Panel) |
| 165 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 166 | 4core x 16 sq mm |
| 167 | LAYING OF CABLE |
| 168 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 169 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 170 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM on surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 171 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 172 | 3.5Core 95sqmm (From Transformer to Main Panel)(One Spare) |
| 173 | 3.5core 50sqmm (From Main Panel to 2nd Floor Panel) |
| 174 | 4core 16sqmm (From Main Panel to Lift Panel) |
| 175 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 176 | 200 mm dia |
| 177 | PANELS |
| 178 | MAIN CONTROL PANEL AT GF |
| 179 | S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomers.20x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.Mandatory provision of cable alley is to be given. |
| 180 | MAIN PANEL |
| 181 | In commer-1-01 number of 320A(40%-100% I n rated) 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA).(FROM TRANSFORMER) |
| 182 | In commer-2-01 number of 200A(40%-100% I n rated) 4P Icu=100%Ics,36kA MCCB with Thermal magnetic based release ( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA). (DG INCOMMER) |
| 183 | Changeover-1- 01 no of 200A 4P onload changeover switch ( DG 01 NO) ( Make-LEGRAND/ Siemens/ Schneider/ABB) |
| 184 | Busbar-1&2 04 numbers of 400Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 185 | Out going- 3 numbers of 40A rating,10 KA breaking capacity,C series, DP MCB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 186 | Out going- 03 numbers of 160A 4P MCCB,25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA |
| 187 | out going 1 no 63A 4P 25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA).(AC,POWER BDB) |
| 188 | out going 1 no 63A 4P contactor for solar feeder .it will be on when dg will be in off position . |
| 189 | Out going- 2 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(LIGHT BDB) |
| 190 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 191 | (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for incomerALL MCCB outgoing feeders shall have digital ammeter suitable rating class 1 CT as per feeder rating. |
| 192 | 1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 193 | LIFT PANEL |
| 194 | SITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD(3P+N) 40ka with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100%Ics as incommer, 100 amp electrolyte cu bus ba-1 Set, 63A Amp TPN RCCB 300mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel) |
| 195 | FLOOR POWER and LIGHT PANEL(2F) |
| 196 | S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. )as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40 kA SPD with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer.20x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication. |
| 197 | In commer 1- 01 no 100A 4P MCCB Icu=100% Ics,,25Ka MCCB withTMR based release with adjustable overload ( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA). |
| 198 | Busbar-1&2 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 199 | Out going- 3 nos 63A 4P MCB 10kA,C series.( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 200 | Out going- 2 nos 40 DP MCB 10kA,C series.( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 201 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 202 | (ii) 01 set digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 203 | iii)01 set of 3 ph digital type Ammeter(0-100)A (MAKE-Siemens/Scheider/ABB/Legrand) with CTs 100/5A 3 nos. class 1 type |
| 204 | AC VRF OUT DOOR PANEL |
| 205 | S/I/T&Commissioning of CPRI Approved LT OUTDOOR,IP 66 floor mounted cubical type electrical main panel (for AC ODU) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40 kA SPD with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer.40x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication. |
| 206 | In commer 1- 01 no 160 4P MCCB Icu=100% Ics,,25Ka MCCB with TMR based release with adjustable overload ( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA). |
| 207 | Busbar-1&2 04 numbers of 300Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 208 | Out going- 3 nos A 4P RCBO,300MA. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200) |
| 209 | Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 210 | (ii) 01 set digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication |
| 211 | UPS MAIN PANEL |
| 212 | S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical ups outgoing panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.2P+N Type 2 20 kA SPD shall be installed in the incomer.20x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication. |
| 213 | Out going- 1nos 63A 2P MCB 10kA,C series.( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 214 | Busbar-1&2 02 numbers of 100Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) |
| 215 | Out going- 6 nos 32A DP MCB 10kA,C series.( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) |
| 216 | Instrument- (i) 02 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 217 | (ii) 01 set of 1 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Secure).(iii)01 set of 1 ph digital type Ammeter(0-100)A(Make-Siemens/Schneider/ABB/Secure) with CTs 60/5A 1 nos class 1 type(Make-KAPPA /AE) |
| 218 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 219 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 220 | Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. |
| 221 | 8 PASSENGER LIFT WITH WIRRING |
| 222 | Supply,Installation, Testing & Commissioning of of 8 Passenger lift gearless with Machine room Capacity(544 Kg),Elevator G+2 Floors with ACVVVF drive/Control with ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . All SS Material shall be of SS-304 Grade and the thickness shall not be less than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons(V) Flat cat 6 cable provision for CCTV with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. make: OTIS/ Mitsubishi/ Johnson/ Schindler |
| 223 | Lift (1Nos) |
| 224 | SIGNAGES |
| 225 | SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 226 | Illumination Glow light for Exit Indication with Battery Back-up. |
| 227 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 228 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 229 | SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 230 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 231 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit |
| 232 | 1mtr Length |
| 233 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP, Netgear |
| 234 | SITC of Dual band 802.11ax 4X4:4 WiFi6 Dual Band Access Point. Complying PoE+ for power, 6 Gbps aggregate wireless throughput, 2.5 Gbps RJ45, and 2.5 Gbps SFP wireline ports with inbuilt on premise virtual controller as well cloud based controlling and administration of WiFi systems. Make: Cisco/Digisol/Netgear |
| 235 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 236 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 237 | SITC of Gate way Router with Built-in firewall provides anti-virus, layer 3-7 IDS/IPS, DPI, SSL detection, and more. Built-in VPN router supports 2.5Gbps or 3Gbps to allow easy remote access. 2 x 2.5 Gigabit SFP port and 10 x Gigabit Ethernet ports *3x Fixed WAN. 2.5Gbps Router. 4 x PoE out ports, IEEE802.3af/at, Maximum PoE Wattage: 36W. Make: Grandstream, Ruijie, HP |
| 238 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 239 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 240 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 10 KM. Make: Cisco, Digisol, Netgear |
| 241 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 242 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 243 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 244 | Supply and installation of project series Network Video Recorder, support 32 Channel, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 320 Mbps and outgoing 320 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, , Support min. 4 SATA HDDs , Each port supports min. 12TB HDD,Support dual Gigabit Ethernet ports,Supports 2 HDMI outputs with a maximum of 4K HD output,Alarm Input/out:16 in /1 out ,Audio:1 in / 1 out ,Raid: Raid 0 & Raid 1,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS |
| 245 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 246 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 247 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. (For CCTV and individual suites) Make: LG/Samsung/Sony |
| 248 | Supply and installation of IP PBX System support up to 500 users and minimum 50 concurrent calls, integrated 1 PSTN trunk FXO ports through External Gateway, 1 analog telephone FXS ports with lifeline capability and up to 50 SIP trunk accounts, Gigabit network ports with Integrates PoE, USB, SD card, Supports up to a 5-level IVR (Interactive Voice Response), Supports any SIP video endpoint that uses the H.264, H.263 or H.263+ codecs. Make: Grandstream, NEC, Mitel |
| 249 | Supply and installation of IP Based PoE Phone, 2 SIP accounts, 2 line keys, 3-way conferencing, 3 XML programmable context-sensitive soft keys, Dual-switched 10/100 mbps ports, integrated PoE, HD audio on speakerphone and handset. Make: Grandstream, NEC, Mitel |
| 250 | Supply and installation of IP Based PoE Phone having 4.3\\" TFT Colour Display, 4 SIP accounts, 10 line keys, 3-way conferencing, 5 XML programmable context-sensitive soft keys, Dual-switched 10/100/1000 mbps ports, integrated PoE,WiFi(Dual Band 801.11AC) HD audio on speakerphone and handset. Make: Grandstream, NEC, Mitel |
| 251 | Lightning Protection |
| 252 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 253 | Supply of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6 in complete as per the direction of Engineer in charge. Make-OBO/Dehn/ABB |
| 254 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 255 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 256 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 257 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 258 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 259 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 260 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 261 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 262 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 263 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 264 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 265 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 266 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 267 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 268 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 269 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 270 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 271 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 272 | UPS SYSTEM(For COMPUTER & COMMON AREA)--Supply ,installation ,testing & commissioning of 10KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,240V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 28AH, 24 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/ APC/ Vertiv)as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 273 | AREA LIGHTING |
| 274 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 275 | Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc.g) SITC of outdoor(IP65) 63A 4P MCCB with bidrectional meter with 2mm CRCA hot dip galvanised panel asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years |
| 276 | Inverter based VRV/ VRF System |
| 277 | Supply of A,C with indoor and outdoor unit |
| 278 | Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s) microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads.The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,blue fin treated condensor coil for corrosion resistant, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.ISEER should be greater than equal to 7.4 for cooling capacity less than 40kWr, ISEER should be greater than equal to 7.5 for cooling capacity more than equal to 40kWr and less than 70kWr and ISEER should be greater than equal to 7.6 for cooling capacity more than equal to 70kWr.The deration chart of outdoor from factory head should be submitted before procurement.Make: Mitshubishi/ TRANE/O-GENERAL/Daikin |
| 279 | Outdoor Unit of Nominal Capacity -16HP |
| 280 | S/I/T/C of ODU Connecting Kit. Make: Mitshubishi/ TRANE/O-GENERAL/Daikin |
| 281 | Supply, Installation,Testing and Commissioning of following minimu capacity 4-way VRV Cassette Type Indoor ceiling mounted unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation,fire resistant metal box protection for indoor unit PCB etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. The cost is inclusive of Refnet joints. Make: Mitshubishi/ TRANE/O-GENERAL/Diakin |
| 282 | Nominal Capacity- 3.98 TR (For conference hall)cassette |
| 283 | Supply, Installation,Testing and Commissioning of following minimum cpacity Wall Mounted Type Indoor unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. Make: Mitshubishi/ TRANE/O-GENERAL/DiakinNominal Capacity- 1.5 TR (For LIVING ROOM) Hiwall |
| 284 | Nominal Capacity- 2.01 TR (For BED ROOM) Hiwall |
| 285 | Supply of Gas Charging for the entire circuit(R410A) |
| 286 | Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular Class O fire rated insulation conforming to BS476 Part6 and part 7 between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow |
| 287 | 28.6 mm with 1.00 mm thick |
| 288 | 22.2 mm with 0.8 mm thick |
| 289 | 15.9 mm with 1.00 mm thick |
| 290 | 12.7 mm with 0.8 mm thick |
| 291 | 9.5 mm with 0.8 mm thick |
| 292 | 6.4mm with 0.8 mm thick |
| 293 | Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular Class O fire rated insulation conforming to BS476 Part6 and part 7 between each set of indoor & outdoor units . All external piping(which are exposed to external environment such as terrace etc.) shall be provided with factory laminated GC Cloth & then shall run in unperporated hot dip galvanized GI. cable tray with cover etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow |
| 294 | 19.1 mm with 0.8 mm thick |
| 295 | 15.9 mm with 1.00 mm thick |
| 296 | Providing & fixing control cum transmission wiring of 2 core x 1.0 sqmm shielded copper cable in suitable conduits between indoor and out door unit. Make-Polycab/KEI/Finolex/RR Kabel/Gloster/Havells/V-Guard |
| 297 | Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness Class O of closed cell nitrile rubber/XLPE as per direction of Engineer-in-charge & specifications enclosed as reqd. |
| 298 | 40 MM dia |
| 299 | 32 mm dia |
| 300 | Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 600mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 301 | Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 450mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 302 | Supplying & laying of one number PVC insulated armoured and PVC sheathed XLPE property copper. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 5core x 10 sq mm |
| 303 | P.H. WORKSupplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge |
| 304 | 2000 liters capacity PVC water storage tank (3 Layer)(Spreme/Sintex/Finolex) |
| 305 | 20mm dia brass full way valve (Shakti make) |
| 306 | 25mm dia brass full way valve (Shakti make) |
| 307 | 32mm dia brass full way valve (Shakti make) |
| 308 | 40mm dia brass full way valve (Shakti make) |
| 309 | 50mm dia BFW Valve (Shakti make) |
| 310 | 25mm size brass ball cock with ball |
| 311 | supplying all materials, labour, T&P and Cutting holes in brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 312 | Supplying all materials , labour, T&P and Cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge |
| 313 | Supplying all materials, labour, T&P and Cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 314 | Supplying the waterproofing material Cementetious base Water proofing Pidifin 2K of Dr.fixit or equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
| 315 | Bore Packing (4\\"-8\\")Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene- butadiene based polymer coating using Latex. Packing the gap using non-shrink cement polymer based grout up to the surface of the bore whilst the Latex is in tacky state seal the Bore with polyurethane Sealant, ,including cost of all material, Labour, T&P etc all complete as per the direction of Engineer in charge. (Latex :- Fosroc -Nitobond SBR/ Myk -AquaArm latex 45/ Sika- Sika Latex power , Polymer based grout::- Fosroc- Renderoc RGL / Myk- Laticrete 3DCP-M30 / Sika- Sika ceram-500TG) |
| 316 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 317 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 318 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 319 | 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 320 | 80mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 321 | 110mm U-PVC Nahani Trap(Ori Plast/Finolex/Supreme Make) |
| 322 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 323 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 324 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 325 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 326 | 110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make) |
| 327 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 328 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 329 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 330 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 331 | 110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make) |
| 332 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 333 | Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge |
| 334 | 25mm dia C-PVC ASTM pipe (sch-80) |
| 335 | 32mm dia C-PVC ASTM pipe (sch-80) |
| 336 | 40mm dia C-PVC ASTM pipe (sch-80) |
| 337 | 50mm dia C-PVC ASTM pipe (sch-80) |
| 338 | VVIP TOILET |
| 339 | BATH ZONE |
| 340 | Supply and installation of 8 mm thick sliding glass door of size 2mX2m Optima Standard - (Width : 2000) JSE-CHR-OPTSDR2000SX of Jaquar make. |
| 341 | Supply and installation of Bath tub of ceramic material of size 1700X750X420 MM of Jaquar make (JBT-WHT-FONT170X) |
| 342 | Supply and installation of Base Europa kit for bath tub (IWA-CHR-ACC 00510X) |
| 343 | Supply and installation of Drain Pipe with overflow system and filler drain pipe 80cm with overflow filler for FONTE model (JWA-CHR-132201) |
| 344 | Supply and installation of Headrest Sophi for bath tub (JWA-BLK-HRSP120GAC06) |
| 345 | Supply and installation of single lever exposed part kit of highflow Diverter constisting of operating lever, cartridge sleeve, wall flange ( with seal), Button Assembly Sleeve & Button (compatible with ALD-079) ARI-39079NK, ARIA-JAQUAR |
| 346 | Supply and installation of Concealed Body for single lever high flow Diverter without exposed parts ALD-079 |
| 347 | Supply and installation of Bath Tub Spout With Button Attachment For Hand Shower With Wall Flange SPJ-CHR-463PM, JAQUAR MAKE |
| 348 | Supply and installation of Maze Hand Shower 65X95mm Rectangular Shape Single Flow (Face Plate Stainless Steel & ABS Body) with Rubit Cleaning System Registered Design No:283937 (HSH-CHR-1657) |
| 349 | Supply and installation of Maze Overhead Shower 300X300mm Square Shape Single Flow (Body & Face Plate Stainless Steel) with Rubit Cleaning System (OHS-CHR-1639) JAQUAR MAKE |
| 350 | Supply and installation of Shower Arm 400X25X25mm Square Shape for Wall Mounted Showers with Flange (SHA-CHR-455L400) JAQUAR MAKE |
| 351 | Supply and installation of Flexible Tube 12mm dia & 1.5M Long with Nuts (SHA-CHR-549D12) JAQUAR MAKE |
| 352 | Supply and installation of Premium Wall Bracket for Hand Shower, 35mm dia. & 100mm Long Round Shape (SHA-CHR-555) JAQUAR MAKE |
| 353 | Supply and installation of Soap Dispenser - Automatic capacity: 0.8L material: aluminium/ABS finish: chrome/black SDR-BLC-DJ0160ASN JAQUAR MAKE |
| 354 | Supply and installation of Towel Rack 600mm Long without Lower Hanger But With 3 HooksCPA-CHR-1181FH, JAQUAR MAKE |
| 355 | Supply and installation of Corner Glass Shelf (with Bracket) ACN-CHR-1173 JAQUAR MAKE |
| 356 | Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2 |
| 357 | Supply and installation of Robe Hook |
| 358 | Supply and installation of 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 359 | WC ZONE |
| 360 | Supply and installation of Rimless Back To Wall WC With UF Soft Close Slim Seat Cover, Hinges, Fixing Accessories And Accessories Set, Size: 340x560x400mm, P-Trap:180mm ARS-WHT-39955P180UFSM, JAQUAR MAKE |
| 361 | Supply and installation of Single Piece Slim Concealed Cistern Body with Installation Kit & “S-Type” drain pipe connection set for Wall Hung WC (without Flush Control Plate) JCS-WHT-2400S,JAQUAR MAKE |
| 362 | Supply and installation of Control Flush Plate Aria JCP-CHR-392415,JAQUAR MAKE |
| 363 | Supply and installation of Two Way Bib Cock with Wall Flange, ARI-CHR-39041, JAQUAR MAKE |
| 364 | Supply and installation of Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook. (ALD-CHR-573) JAQUAR MAKE |
| 365 | Supply and installation of Toilet Roll Holder with Flap CPA-CHR-1153 JAQUAR MAKE |
| 366 | Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2 |
| 367 | WASH BASIN ZONE |
| 368 | Supply and installation of Table Top Basin,Size: 700 x 435 x 135mm ARS-WHT-39903, JAQUAR MAKE |
| 369 | Supply and installation of Click Clack Waste 32mm Size Half Thread with 130mm Height ALD-CHR-729L130, JAQUAR MAKE |
| 370 | Supply and installation of Bottle Trap 32mm Size with 250mm & 190mm Long Wall Connection Pipes & Wall Flange ALD-WHM-769L250X190 |
| 371 | Supply and installation of Exposed Part Kit of Single Lever Basin Mixer Wall Mounted Consisting of Operating Lever, Cartridge Sleeve, Wall Flange, Nipple & Spout (Compatible with ALD-233N or ALD-235N) ARI-CHR-39233NK, JAQUAR MAKE |
| 372 | Supply and installation of Concealed Body for Single Lever Basin Mixer Wall Mounted, But without Exposed Parts ALD-CHR-233N, JAQUAR MAKE |
| 373 | Supply and installation of Flash touch-free infrared Hand dryer with 1150W rated power & carbon brush motor HDR-SSF-AK2807-Jaquar Make |
| 374 | Supply and installation of Soap Dispenser with Glass Bottle (ACN-CHR-1135N)-Jaquar Make |
| 375 | Supply and installation of Towel Ring Square (AKP-CHR-35721P) -Jaquar Make |
| 376 | Supply and installation of Swivel Mirror 630 X 445mm Rectangular Shape (AKP-CHR-35795)-Jaquar Make |
| 377 | Supply and installation of Double Arm Wall Mounted Reversible Plain/ Magnifying (3X) Pivotal Mirror (ACN-CHR-1193N)-Jaquar Make |
| 378 | Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2 |
| 379 | Common Toilet |
| 380 | WC ZONE (Gents Toilet) |
| 381 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 382 | European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) |
| 383 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 384 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 385 | Supply and installation of 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 386 | Supply and installation of 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 387 | 15mm dia Hand Shower (Health Faucet) -with 8 mm dia 1.2 m long flexible tube and wall hook (ALD 573) of Jaguar make. |
| 388 | Supply and installation of Soap Dish Holder (AKP-CHR-35731P)-Jaguar make. |
| 389 | Single Towel Rail 450mm Long CPA-CHR-1111L450- Jaguar make. |
| 390 | Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2 |
| 391 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 392 | WASH BASIN ZONE |
| 393 | Supply and installation of Table Top Basin,Size: 700 x 435 x 135mm ARS-WHT-39903, JAQUAR MAKE |
| 394 | Supply and installation of Click Clack Waste 32mm Size Half Thread with 130mm Height ALD-CHR-729L130, JAQUAR MAKE |
| 395 | Supply and installation of Bottle Trap 32mm Size with 250mm & 190mm Long Wall Connection Pipes & Wall Flange ALD-WHM-769L250X190 |
| 396 | Supply and installation of Pillar Cock with 135mm Extension Body (ALI-CHR-85021) JAQUAR MAKE |
| 397 | Supply and installation of Concealed Body for Single Lever Basin Mixer Wall Mounted, But without Exposed Parts ALD-CHR-233N, JAQUAR MAKE |
| 398 | Supply and installation of Soap Dispenser - Push Button capacity: 0.8L material: ABS finish: white/smoked SDR-WHT-DJ0010FN -Jaguar make. |
| 399 | Supply and installation of Towel Ring Square (AKP-CHR-35721P) -Jaquar Make |
| 400 | Supply and installation of Swivel Mirror 630 X 445mm Rectangular Shape (AKP-CHR-35795)-Jaquar Make |
| 401 | Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2 |
| 402 | Common Toilet |
| 403 | WC ZONE (Ladies Toilet) |
| 404 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 405 | European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) |
| 406 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. |
| 407 | 580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 408 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 409 | 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 410 | Supply and installation of 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 411 | Supply and installation of 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 412 | Supply and installation of 15mm dia Hand Shower (Health Faucet) -with 8 mm dia 1.2 m long flexible tube and wall hook (ALD 573) of Jaguar make. |
| 413 | Supply and installation of Soap Dish Holder (AKP-CHR-35731P)-Jaguar make. |
| 414 | Supply and installation of Single Towel Rail 450mm Long CPA-CHR-1111L450- Jaguar make. |
| 415 | Supply and installation of Table Top Basin,Size: 700 x 435 x 135mm ARS-WHT-39903, JAQUAR MAKE |
| 416 | Supply and installation of Click Clack Waste 32mm Size Half Thread with 130mm Height ALD-CHR-729L130, JAQUAR MAKE |
| 417 | Supply and installation of Bottle Trap 32mm Size with 250mm & 190mm Long Wall Connection Pipes & Wall Flange ALD-WHM-769L250X190 |
| 418 | Supply and installation of Pillar Cock with 135mm Extension Body (ALI-CHR-85021) JAQUAR MAKE |
| 419 | Supply and installation of Soap Dispenser - Push Button capacity: 0.8L material: ABS finish: white/smoked SDR-WHT-DJ0010FN -Jaguar make. |
| 420 | Supply and installation of Swivel Mirror 630 X 445mm Rectangular Shape (AKP-CHR-35795)-Jaquar Make |
| 421 | Supply and installation of FLOOR GRATING DRAINER WITH BOWL SIZE 150X150 SS304 GRADE Model 2 |
| 422 | Pantry Zone |
| 423 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink |
| 424 | Supply and installation of 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 425 | Ext. S/D Portion |
| 426 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge |
| 427 | 100mm dia P.V.C. pipe |
| 428 | 150mm dia P.V.C. pipe |
| 429 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge |
| 430 | Inside size 76cmx76cmx46cm with 18” dia RCC MH cover Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy