| 1 | Dismantling mangalore pattern roofing tiles or similar tiles single layers complete all as specified and directed |
| 2 | All as per Item No 1 here-in-before, but bedded in lime or cement mortar complete all as specified and directed. |
| 3 | Material and labour for roof tiles, mangalore pattern,interlocking at side joints, laid dry complete all as specified and directed. |
| 4 | All as per above item but except tiles complete all as specified and directed. |
| 5 | Material and labour ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and directed. |
| 6 | Material and labour for preparation of new MP roof tile surfaces by cleaning the tiles and applying two coats of antifungal paint using UNIGLOSS deluxe multi surface paint over a coat of primer complete all as specified and directed |
| 7 | Material and labour for preparation of old MP roof tile surfaces by cleaning the tiles and applying one coats of antifungal paint using UNIGLOSS deluxe multi surface paint complete all as specified and directed |
| 8 | Dismantling battern for tiles, shingles etc of any size including fillets spaced exc. 15cm complete all as specified and directed |
| 9 | Material and labour for clean sawn battens at 25cm centres sectional area exc 5 & nexc 15Sqcm 2nd class hardwood complete all as specified and directed |
| 10 | Dismanling timber scantling 40 Sqcm and over in section, in any position unframed work complete all as specified and directed |
| 11 | Dismantling framed work timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed |
| 12 | Material and labour for timber fixed clean swan second class hard wood in scantlings complete all as specified and directed |
| 13 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 14 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed |
| 15 | Supply and fix pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to all, fixed with self tapping screws complete all as specified and directed |
| 16 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 17 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 18 | Supply and fix steel work in tubular trusses, purlins including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979Grade St-240 for square or rectangular tube complete all as specified and directed |
| 19 | Material and labour for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed |
| 20 | Material and labour for cleaning inside RCC static water tank of capacity upto 227000 ltrs at NAD by empyting the tank removing dirt,sediments, silts ,algae etc from internal, bottom and wall surfaces of tank using suitable brushes applying bleaching powder and other cleaning agents as required ,washing with clean water including writing capacity of tank, date of cleaning and next due date of cleaning on outside the tank using synthetic enamel paint ,removing of creepers and bushes over the static water tank and perimeter of the static water tank including painting inside and outside surface by antifungal exterior emulsion paint (removing existing treatment and applying two coats of paint over a coat of exterior primer) complete all as specified and directed |
| 21 | Taking down existing water proofing treatment of any description and removal of rubbish off the premises complete all as specified and directed |
| 22 | Demolition of cement concrete in roofs, floors(other than ground floor) ,beams, stair cases, landing ,chajjas and similar suspended work complete all as specified and directed |
| 23 | Material and labour for water proofing treatment by preparing the water proofing slurry by adding DITCHTAMENT (Polymer modified mineral based powder) into water diluted NAFUFILL BB2(acrylic based polymer binding agent) diluted with 4 part of water and apply this slurry@ 2Kg/Sqm in two coat over the surface. 60 grams of NAFUFILL BB2 per kg of DITCHTAMENT shall be used or equivalent product of Dr Fixit/Fosroc may be used as per manufacturer's instruction. |
| 24 | Material and labour for 25mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in floor finished even and fair complete all as specified. |
| 25 | Rendering 15mm thick on fair faces of concrete surfaces in CM 1:3 finised even and smooth without using extra cement with using WPC complete all as specified and directedNote :- WPC will measured and paid seperately. |
| 26 | Brushing neat cement slurry with 3.00 Kg of cement per Sqm with WPC complete all as specified and directed.Note :- WPC will be measured and paid seperately. |
| 27 | Supply only liquid water proofing compound complete all as specified and directed |
| 28 | Material and Labour for preparation of roof surface by throughly wire brused ,washed ,dried up,cleaned of all the foreign matters and dust ,and applying bituminous primer @250gms/sqm ,and then laying 4mm thick APP modified bituminous membrane with non woven polyster matt as reinforced weighting not less than 4.00kg per sqm ,laid on primed surface with torch application method by providing overlap minimum 100mm longitudnal and 150mm on tranverse direction & applying a tack coat of blown grade hot bitumen 90/15 over the membrane @1.20kg/sqm including cleaning surfaces & over the membrane finishing with solar reflective bituminous aluminium paint @ 0.10kg/Sqm.All angles and similar projections should be sealed well with extra care to ensure full bondage,all joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR Latex @ 200ml /bag of cement complete all as specified and directed |
| 29 | Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed |
| 30 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finised even and smooth without using extra cement with using WPC complete all as specified and directedNote :- WPC will measured and paid seperately. |
| 31 | Material and labour for preparation of new plastered surfaces of walls & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed |
| 32 | Material and labour cleaning the surfaces of brick/rcc using wire brush,brooming down and washing down with water to remove dust etc and brushing with neat cement slurry @0.5kg/sqm with acrylic based polymer modified cementitous composite (Pidifine 2K)@ 0.5kg/sqm complete all as specified and directed |
| 33 | Removal of vegetation/grass etc including cutting holes into or through brick walls/concrete and removal of small trees/woods etc and making good disturbed surfaces with cement concrete 1:2:4 type B0 using 12.5mm graded aggregate complete all as specified and directed |
| 34 | Cleaning/uprooting of vegetation/small trees, muds, garbages, wastes etc growth on inaccessible RCC roof, GI sheet roof, below wind tie, cleaning of CGI sheet, valley gutter and shaft portion of wall surfaces, back side of toilet portion and above complete all as specified and directed |
| 35 | Notes for Item Nos 1 to 34 :-(i) The Scope of Work is to be carried out from Ground Level to nearly upto 4 Storey (upto 15 Metres of Height) (ii) The work to be carried out on vertical surfaces, RCC roofs, Mangalore tiles roof and galvalume sheet roofs.(iii) Rates are included for Scaffolding/Boom lift/Crane as required. Contractors should arrange necessary scaffolding/ Boomlift/Crane and takes all safety precautions for workers at the time of carrying out works as described in sch 'A'/ BOQ(iv) Contractor should visit the site before quoting the tender to assess the resources required to execute the work as the site .(v) Cost of all factors to be deemed to be included in the rate quoted in BOQ. No Extra Claim will be entertained. |
| 36 | Material and labour for removing the existing joint sealing completely by mechanical means and remove all the dust and laitance by blown dry by compressed air and prime the surface with primer 20 using a clean dry brush to required depth and apply masking tape on both sides of the joint exceeding 8mm & not exc 20mm width and min 15mm depth completely for uniformity and colpor 200PF must be applied between 30 min and 02Hrs when the primer has become touch dry; the curing agent shall be mixed with the base component and mix for a min of 3 minutes and loaded into a sealent gun after removing the nozzle and cap and apply on the joint fully and make the filling flush and remove the masking tapes completely and allow to set for a min of 12Hrs to 16Hrs before accepting traffic complete all as specified and directedNote:- Colpor 200 PF, fosroc primer 20 and backer rod will be measured and paid seperately. |
| 37 | Supply only fosroc colpor 200 PF including primer 20 or equavalent in Bostik/Sika Flex/master seal with all necessary accessories complete all as specified and directed.Note :- The quantity of primer and PU filler material shall be as per manufacturer's instructions and quantity of PU (Colpor 200 PF) shall be measured for payment purpose. |
| 38 | Supply and fix backer rod for joints of size exceeding 8mm and not exc 20mm all as per site requirement complete all as per manufacture instructioins complete all as specified and directed |
| 39 | Material and labour for preparing concrete/bituminous surfaces of road/dispersal and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n exc 10cm wide on road pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed |
| 40 | Taking down cement plastering on brick work or concrete surfaces, baffle walls/stop butt , side walls etc including raking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding and safety equipments (height not exceeding 12 m) complete all as specified and directed |
| 41 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth with out using extra cement and adding Recron 3S fibres( manufacture -Reliance industries) of 6mm at the rate of 125g per bag of cement including necessary scaffolding and safety equipments for baffle wall , side wall & stop butt (height not exceeding 12 m) etc complete all as specified and directed |
| 42 | Material and labour for preparation of new plastered surfaces of walls ( baffle walls, stop butt, side walls) & applying Two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. including necessary scaffolding and saftey equipments (height not exceeding 12 m) complete all as specified and directed. |
| 43 | Material and labour for preparation of old painted surfaces of baffle walls, stop butt, side wallSupply and fixICS panels and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm including necessary scaffolding and saftey equipments (height not exceeding 12 m) completed all as specified and directed |
| 44 | Material and labour for moorum/red bajri filling in inclined portion of stop butt of baffle range, laid in layers n exc. 30 cm thick, spread, levelled and rammed using mechanical compactor/ back hoe /Hitachi including watering complete all as specified and directed. |
| 45 | Supply and fix in PVC connections 15mm size with PTMT nuts of length 600mm long complete all as specified and directed |
| 46 | Supply and fix in repair to to plastic water closet seat for EWC /Angilo indian type , black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed |
| 47 | Repair only in high or low level flushing cistern with replacement of necessary washers ,push etc , and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed |
| 48 | Supply and fix in repair to health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 49 | Supply and fix in repair to CP 15mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule omplete all as specified directed. |
| 50 | Supply and fix in repair to 15mm bore CP fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified directed. |
| 51 | Supply and fix in repair to 15mm dia chromium plated fancy type Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified directed. |
| 52 | Supply and fix in repair in 32mm bore waste coupling with waste pipe of PTMT (half or full threaded) . (minimum weight 32mm- 45gms/40mm-60 gms) for HWB ,sink , etc complete all as specified and directed |
| 53 | Supply and fix in repairs 150mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor incl vulcanised rubber piece complete all as specified and directed |
| 54 | Demolition of unreinforced cement concrete in ground floor and paving n.exc 15 cm thick below or above ground level complete all as specified and directed |
| 55 | Material and labour for 25mm tk cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in floor surfaces complete all as specified and directed |
| 56 | Taking down shutters exe 1 Sqm not exe 2 Sqm each and refixing with same opening after Resecuring or easing and adjusting /cutting with a required repair incl refixing builders hardware as required including renewal of unserviceable screws, etc complete all as specified and directed |
| 57 | Supply and laying sand bags of 50 Kg at specified location and up to specified height complete all as specified and directed |
| 58 | Attending internal/external electric complaints for maintenance/breakdown round the clock for maintenance, checking, fault finding ad rectification of fault in LT panels overhead HT/LT lines, HT/LT underground cables, Transformers, Switchgears internal electric faults, fans etc and carry out repairs and resume electric supply complete all as specified and directed Notes:- (a) Day to day complaint rectified by the electrician shall be written in complaint register and complaint document slip, rectified complaints only shall be measured and paid. Complaint attender shall have minimum qulification of ITI Electrician cum pumber having 2 years experiance of same nature of work is to be employed. (b) The spares required for rectification of faults shall be measured under relevent items. (c) All necessory tools shall be made available with the tecnician while executing the complaint. (d) All consumeables other than mentioned in schedules are deemed to be included in the rate quoted. (e) All kind of transport for the complaint attender/materials and mobile/cell charges are deeme to be included in the rate quoted. (f) All safety aspects are to be taken and if any accident/hazardous incidents happen during execution shall be the sole resposibility of the contractor. (g) Penalty of Rs 1000/- per complaint will be recovered from contractor if the complaint will not rectified within 24 hours. |
| 59 | Supply LED tube light fitting of 20 watt, 230V, with extruded aluminium housing enhances safety, high quality PC diffuser, easy to install efficacy 110/125 lumen/watt complete all as specified and directed |
| 60 | Supply LED tube light fitting of 10 watt, extruded aluminium housing enhances safety, high quality PC diffuser, easy to install efficacy 100 lumen/watt complete all as specified and directed |
| 61 | Supply and fix in replacement modular switch 1 way 6A,1 module, complete all as specified and directed |
| 62 | Supply and fix in replacement modular socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed |
| 63 | Supply and fix in replacement modular socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed |
| 64 | Supply and fix in replacement modular Fan step regulator, 120W - 2 module complete all as specified and directed |
| 65 | Supply and fix in replacement MCB SP 6 to 32 Amps, 220 volts, 10 KA, 'C' series complete all as specified and directed |
| 66 | Supply and fix in replacement MCB SPN 25 to 32 Amps, 220 volts, 10 KA, 'C' series complete all as specified and directed |
| 67 | Supply and fix in replacement MCB TPN 63 Amps, 415 volts, 10 KA, 'C' series complete all as specified and directed |
| 68 | Supply and fix in replacement RCCB double pole, 30mA, 25A complete all as specified and directed |
| 69 | Supply and fix in replacement RCCB 4 pole, 30mA, 63A complete all as specified and directed |
| 70 | Supply and fix in replacement LED 2 x 2 feet fitting, 36W, 230V,with CRCA powder coated housing and high quality PC diffuser, efficacy of 120 Lumen/watt , THD <10,L70 B50, , PF >0.95, with seperate driver module , complete with all accessories internally pre-wired and incl connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 71 | Supply and fix in replacement capacitor 2.5/3.15/4 mfd, 240 volts, AC suitable for fans etc. |
| 72 | Taking down fan, any size any make from various satellite area locations, for repair/replacement of defective parts and rehanging/refixing in its original location after reconditioning complete as specified and directed for cieling fan of size 1200/1400 mm sweep, wall fan/exhaust fan upto 450mm sweep complete all as specified and directed Note:- Items for reconditioning will be measured and paid separately under respective items of BOQ. |
| 73 | Material and labour for removing the burnt out winding, cleaning slots, rewinding the motor with super enamelled copper wire of equivalent size to the original winding including warnishing, drying etc replacement of body screws, testing and commissioning on full load for 8 hours continous runing for ceiling fan 1200/1400mm sweep complete all as specified and directed |
| 74 | All as per item No 72 here-in-before but for wall fan/exhaust fan/pedestal fan upto 450 mm sweep complete all as specified and directed |
| 75 | Supply and replace ball bearing made out of high carbon steel as per existing suitable for Ceiling fan any type any size complete all as specified and directed |
| 76 | Supply and replace bush bearing made out of brass alloy as per existing suitable for Ceiling fan any type any size complete all as specified and directed |
| 77 | Material and labour for disconnecting from position, servicing at same location including cleaning of interior parts and body with solvent materials, replacement of unserviceable spares/parts if required.necessory repairs, connecting, testing and commissioning of water cooler upto 120 ltrs, ozone based filter type hot and cold water cooler 85 ltrs capacity, refrigerator upto 310 ltrs cap complete all as specified and directed Note:- Spares will be measured and paid separately. |
| 78 | Supply and fix in repair power supply PCB suitable for Hot and Cold water cooler complete all as specified and directed |
| 79 | Supply and charging refrigerant gas upto required level including connected works such as pressure testing leak test with nitrogen before filling refrigerant gas complete for split AC upto 3 TR, complete all as specified and directed |
| 80 | Material and labour for servicing of split AC indoor/outdoor unit upto 3 TR comprising through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts, rectifying electric wiring, defects etc to make the unit for smooth functioning complete all as specified and directed Please Enable Macros to View BoQ information |
| 81 | Material and labour for servicing of split AC indoor/outdoor unit upto 3 TR comprising through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts, rectifying electric wiring, defects etc to make the unit for smooth functioning complete all as specified and directed Please Enable Macros to View BoQ information |