|
| 1 | 5.10.7Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | DSR 15.5Extra for cutting reinforcement bars manually/ by mechanical means inR.C.C. or R.B. work (Payment shall be made on the cross sectional areaof R.C.C. or R.B. work) as per direction of Engineer-in-charge |
| 3 | 5.10.3Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | 5.8.9Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 5 | 5.10.4Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 6 | 5.3.1.2Providing P.C.C. M150 with normal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, striking, curing, tax and royalty all complete job as per building specification and direction of Engineer in charge. |
| 7 | 5.3.11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 8 | 5.7.6Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | 5.7.3Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | DSR 13.47.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 12 | 5.8.18Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 13 | 5.10.11Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 14 | 5.10.10Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 15 | 5.5.12Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 16 | 5.5.29Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 17 | 5.8.45Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 18 | 5.7.15Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 19 | DSR 14.91.1Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black f inished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 20 | DSR 18.7Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 21 | DSR 18.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge18.7.115 mm nominal dia Pipes |
| 22 | 18.7.220 mm nominal dia Pipes |
| 23 | 18.7.325 mm nominal dia Pipes |
| 24 | DSR 18.9.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes |
| 25 | PHED 3.1.6Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l .A) BRASS STOP COCK15mm dia |
| 26 | PHED 3.1.7Providing and fixing G.M. non return valve Horizontal / vertical type of approved quality as per specification and direction of E/l.(A) Horizontal non return valve(2) 20 mm dia wt not less than 250 gms |
| 27 | (B) Vertical non return valve(1)15 mm dia wt not less than 150 gms |
| 28 | PHED 3.1.5.1Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . |
| 29 | DSR 12.41Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.12.41.2110 mm diameter |
| 30 | DSR 12.42Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.12.42.112.42.1 Coupler110 mm |
| 31 | 12.42.212.42.2 Single pushfit Coupler110 mm |
| 32 | 12.42.3ingle tee with door110 mm |
| 33 | 12.42.4ingle tee without door110 mm |
| 34 | 12.42.5Bend 87.5°110 mm |
| 35 | 12.42.6hoe (Plain)110 mm |
| 36 | 5.3.8Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 37 | 5.10.34Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 38 | 5.5.4providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)8mm dia bar |
| 39 | 5.5.5providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 40 | 5.1.1Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 41 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B) |
| 42 | 5.1.10Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 43 | 5.6.3Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 44 | 5.3.1.2Providing P.C.C. M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 45 | 5.2.6Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 46 | 5.2.23Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials , scafolding, raking out joints to 15 mm depth, curing, taxes and royalty ( but excluding the cost of reinforcement) all complete as per building specification and direction of E/l. |
| 47 | 5.3.9.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. |
| 48 | 5.3.11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 49 | 5.7.1Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 50 | 5.7.11Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l. |
| 51 | 5.5.4Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 5008mm dia |
| 52 | 5.5.5Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.10 mm dia |
| 53 | DSR 19.31.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design 21.39.2 19.32.1With F.P.S. bricks |
| 54 | 1.1Point wiring in PVC conduit, with piano type switch -Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required1.1.1Group A |
| 55 | 1.23S/F piano type switch/socket - Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required.1.23.15/6 amps, one way switch |
| 56 | 1.23.315/16 amps, one way switch |
| 57 | 1.23.43 pin 5/6 amps, socket outlet |
| 58 | 1.23.515/16 amps, 6 pin socket outlet |
| 59 | 1.7Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.1.7.12 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 60 | 1.7.22 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 61 | 1.7.84 x 2.5 sq.mm. + 2 x 2.5 sq.mm. earth wire |
| 62 | 1.3S/F power plug point with piano type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as requird. |
| 63 | 1.34S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required. |
| 64 | 1.33S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 65 | 9.5SITC of followitn rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required.9.5.110/12 W Led Tube Light |
| 66 | 9.5.220/22W LED tube light |
| 67 | M-85615/16 Watt LED Bulb |
| 68 | 9.4Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire uitable for 230V 50H2, single phase supply etc. complete as required.9.4.11200mm (48\\") Ceiling Fan |
| 69 | 1.25S/F Modular type electronic fan regulator : Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 70 | 2.8S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)2.8.48 way, single door |
| 71 | 2.11S/F 'B' series, S.P. MCB -Supplying and fixing 6 amps to rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required2.11.16/32 amps, single pole \\"B\\" series |
| 72 | 2.12S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.2.12.36/32 Amps, SPN |
| 73 | 2.12.750/63 amps, DP |
| 74 | 9.2S.I.T.C. of following rating LED Flood lighting lumninarie with pressure dia cast housing and thoughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz Luminarie shall be confirmed to IS: 10322 part-5/section-3 and shall be complete with all necessary accessories as required. 9.2.250/60 W LED Flood Light |
| 75 | 5.1.1Earth work in excavation in foundation trenches - do - all complete as per building specification and direction of E/I. |
| 76 | 5.1.10Providing coarse clean sand in filling in foundation trenches -do - all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 77 | 5.6.3Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 78 | 5.3.1.5Providing P.C.C (1:3:6) in foundation -do - all complete as per building specification and direction of E/I |
| 79 | 5.3.2.1Providing R.C.C (1:1.5:3) in foundation -do - all complete as per building specification and direction of E/I |
| 80 | 5.3.17.1Centering and shuttering including strutting , propping etc. and removal of form for foundation , footing , bases of columns, etc for mass concrete. |
| 81 | 5.3.9.1Providing R.C.C (1:1.5:3) in band at plinth -do - all complete as per building specification and direction of E/I |
| 82 | 5.3.17.5Centering and shuttering including strutting , propping etc. and removal of form for Lintels, beams , plinth beams, girders, bressumers and cantilever. |
| 83 | 5.2.6Providind designation 75 B brick work in C.M. (1:6) in foundation and plinth - do- |
| 84 | 5.2.14Providind designation 75 B brick work in C.M. (1:6) in superstructure - do-as per specification and direction of E/I. |
| 85 | 5.2.23Providind designation 125 mm thick 75 A brick work in C.M. (1:4) in superstructure - do-as per specification and direction of E/I. |
| 86 | 5.3.2.1Providing R.C.C (1:1.5:3) in band at lintel level -do - as per specification and direction of E/I. |
| 87 | 5.3.17.5Centering and shuttering including strutting , propping etc. and removal of form for Lintels, beams , plinth beams, girders, bressumers and cantilever. |
| 88 | 5.3.10Providing R.C.C (1:1.5:3) in column -do- all complete as per building specification and direction of E/I. |
| 89 | 5.3.17.6Centering and shuttering including strutting , propping etc. and removal of form for columns, pillars, piers, Abutments, posts and struts. |
| 90 | 5.3.2.1Providing R.C.C (1:1.5:3) in roof slab -do- all complete as per building specification and direction of E/I. |
| 91 | 5.3.17.3Centering and shuttering including strutting , propping etc. and removal of form for suspended floors, roofs, landings, balconies and acess platform. |
| 92 | 5.7.3Providing 12 mm thick cement plaster (1:6) -do- all complete as per building specification and direction of E/I. |
| 93 | 5.7.6Providing 6 mm thick cement plaster (1:4) in ceiling -do- all complete as per building specification and direction of E/I. |
| 94 | 5.5.5Providing TMT steel reinforcement - do - all complete as per building specification and direction of E/I. |
| 95 | 5.4.1S/F/F good quality ,well dressed and well seasoned sal wood in choukhat in doors, windows skylights -do- all complete as per building specification and direction of E/I. |
| 96 | 5.4.38S/F/F 35 mm thick solid core type non decorative single leaf flush shutters in door and windows -do- all complete as per building specification and direction of E/I. |
| 97 | 5.6.23.1Providing and laying 6 mm pre - cast white glazed tiles in wall -do- all complete as per building specification and direction of E/I. |
| 98 | 11.37 DSRProviding and laying glazed ceramic tiles in flooring -do- all complete as per building specification and direction of E/I. |
| 99 | 13.47.1 DSRFinishing walls with Acrylic smooth exterior paint -do- all complete as per building specification and direction of E/I. |
| 100 | 5.8.32Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 101 | 0Providing and laying factory made coloured chamfered edge cement concrete paver block of required strength , thickness and size/shape, made by vibratory method using PU mould laid in required colour & pattern over 80 mm thick compacted bed of fine sand ,compacting and proper embedding /laying of inter locking paver blocks in to the sand bedding layer through vibratory compaction by using plate vibrator , filling the joints with sand and cutting the paver blocks as per required size and pattern ,finishing and sweeping extra sand in footpath parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of E/I. 60 mm thick C.C. paver block of M-35 grade with approved colour, design and pattern. |
| 102 | 0Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -all work up to plinth level: (1:2:4) (1 cement : 2 coarse sand (zone III ) : 4 graded stone aggregate 20 mm nominal size ) |
| 103 | All sanitary works including labour cost. |
| 104 | 5.8.2White washing two coats over old surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing,scaffolding,washing,of floors and taxes all complete as per building specification and direction of E/I.r Old Surface |
| 105 | 5.8.14Providing two coats of dry distemper of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I. |
| 106 | 5.8.45Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 107 | Carriage of material:-Cement (Lead 3.0 km ) |
| 108 | Sand (Barakar) lead 35.0 km Qty |
| 109 | Stone Chips lead 17 km Qty |
| 110 | Steel (Lead 3.0 km) |
| 111 | Brick (lead 8.0 Km ) |
| 112 | Stone Metal |
| 113 | Add 18% GST |
| 114 | Add 1% Labour Cess Please Enable Macros to View BoQ information |