Name of Work:- Procurement of Minilec make various timers, relays etc for 2x600MW, SSTPP, MPPGCL, Dongalia.
Sl. No.
Item Description
1
Single-Phase Preventer with Under and Over Voltage protections.Model: ALV D2System Supply: 415 V ACAuxiliary Supply: 380 – 415 – 440 V ACProtections: Single Phasing, Phase Sequence Reversal, Phase to Phase Voltage Unbalance, Under Voltage and Over VoltageTrip Delay: 3.5 ± 1.5 sec.Output Contacts: 2 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
2
Single-Phase Preventer.Model: VSP D2System Supply: 415 V ACAuxiliary Supply: 240 V ACProtections: Single Phasing, Phase Sequence Reversal, Phase-to-Phase Voltage UnbalanceUnbalance: 30 V – 70 V ACTrip Delay: 3.5 ± 1.5 sec.Output Contacts: 2 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
3
Single-Phase Preventer.Model: VSP D1System Supply: 415 V ACAuxiliary Supply: 240 V ACProtections: Single Phasing, Phase Sequence Reversal, Phase-to-Phase Voltage UnbalanceUnbalance: 40 V ACTrip Delay: 3.5 ± 1.5 sec.Output Contacts: 1 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
4
Under and Over Voltage RelayModel: D2 VCT1 (Upgraded version of VCF D2)System Supply: 380 – 415 – 440 V ACProtections: Under Voltage, Over Voltage and Neutral FailTrip Delay: 1 – 10 sec.Power ON Delay: 1 – 10 sec.Output Contacts: 2 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
5
Single-Phase Preventer with Under and Over Voltage protections.Model: S2 VMR3System Supply: 380 – 415 – 440 V ACProtections: Single Phasing, Phase Sequence Reversal, Phase to Phase Voltage Unbalance, Under Voltage and Over VoltageUnbalance: 2% - 20%.Trip Delay: 1 – 10 sec.Under Voltage: 285 – 425 V ACOver Voltage: 400 – 520 V ACOutput Contacts: 2 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
6
Water Level ControllerModel: WLC D1 with 3 sensors.Auxiliary Supply: 415 V ACOutput Contacts: 1 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
7
Multifunction TimerModel: D1 ETM1Auxiliary Supply: 24 – 240 V AC / DCOperations: On Delay, Cyclic Delay ON First, Cyclic Delay OFF First, Interval Delay, Star Delta, Engine Start Delay, Instantaneous & DelayedTime Range: 0.1 Sec. – 100 Hrs.Output Contacts: 1 CO + 1 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
8
ON Delay TimerModel: S1 ETS1Auxiliary Supply: 240 V ACOperations: On DelayTime Range: 3 Sec. – 30 sec.Output Contacts: 1 COContact Rating: 5A @ 240 V AC (resistive load)Mounting: DIN Rail
9
Phase Failure relayModel:- D2 VMR 2 Please Enable Macros to View BoQ information