| 1 | RENOVATION OF BHOGA MANDAPPlain Cement concrete (1:2:4) using 20mm to 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour and T&P etc. required for the work complete.Bhoga Mandap |
| 2 | Fly Ash brick masonry in cement mortar (1:6) in Superstructure using Fly Ash bricks of 25cmx12cmx8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work complete in all respect in all floors |
| 3 | Reinforced cemnet concrete of M-20 grade as per approved designs and drawing having a minimum compressive strength (in work test) of 200kg/cm2 in 15 cm cubes at 28 days after mixing and test conduct in accordance with I.S 456 and I.S 516 using 12 mm to 20 mm. size black hard crusher broken granite chips (20 mm. size chips not to exceeds 25%) and screened and washed sharp sand for mortar of approved quality from approved quarry to be mixed in concrete mixture including hoisting,lowering, laying and compacting concrete by using vibrators, wateringand curring for 28 days, centering and shuttering then after dismantling and remoing debrish from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete but excluding cost and conveyance of M.S rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S rods or Tor steel tying the grills and placing in proper position as directed by the Engineer in charge. |
| 4 | Roof Slab First Floor Stair Case |
| 5 | 20mm (3/4\\") thick cement plaster (1:2:2) using 1 part cement 2 part sand and 2 part 4.75mm c.b.h.g. chips [Vide AR page-106/17]Bhoga Mandap/ |
| 6 | 12mm (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the joint including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 7 | 16mm (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after raking out the joints including watering and curing with cost with cost, conveyance, royalties and taxes of all materials with all labour, T&P required for the work etc. complete. |
| 8 | 6mm thick cement plaster (1:4) and using slurry treatment to ceiling including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 9 | Rigid and Smooth Centering and shuttering & Dismentering the same after casted including cost of material etc.complete. |
| 10 | S/F/F of ms square pipes50X50X5mm hollow column ms pipes, clits, trusses, 50x50mm square hollow section, 50mmx50mmsq. Hallow pipe |
| 11 | Red profile sheets 14' long |
| 12 | Ridge 2'x10' |
| 13 | Hoisting joists and trusses and placing in position(L/C only) Data for 0.508qtl |
| 14 | Labour for fixing GCI sheets in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc excluding fixing of fittings per 1sqm |
| 15 | cost of nut,bolt a/v |
| 16 | s/painting 2coats over 1coat of primer |
| 17 | COST OF WELDING CHARGES A/V |
| 18 | Supplying and Priming one coat with any aproved Primer. qty. same as out side plasterBhoga Mandap/Male and Female Toilet/ |
| 19 | Wall painting with 2 coats weather coat paint of approved shade on outside work to give an even shade including cost of paint. |
| 20 | Supplying laying and fixing tiles in floors of size 600mm x600m size approved make conforming IS 13755 laid on 20mm thick CM (1:4) and filling joint with white cement of approved including all cost etc. |
| 21 | Supplying laying and fixing tiles in wall Dados on 12mm thick cement mortar(1:3) jointed with neat cement slurry mixed with pigments to match shade of the ceramic tiles complete as per direction ofEngineer- in-charge . |
| 22 | supplying,priming,cement based wall putty,plastic paint….Qty of 16mm plaster Deduct qty of Dados |
| 23 | Labour charges for cutting, bending,binding & tying the M.S.Rod & placing in posion including cost of binding wires & cost of M.S.Rod etc |
| 24 | 30cm x 30cm / 40cm x 40cm special plain / printed series Ciramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS-13755Mandir side chequred tile |
| 25 | MALE AND FEMALE TOILET Earth work in excavation of foundation trenches in hard soil including dressing and leveling the bed and depositing the soil within 50M initial lead and 1.5M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3M in depth and as per the direction of the EIC. |
| 26 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties & taxes of sand with labour & T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 27 | Cement concrete of proportion (1:3:6) in foundation using 4cm (1 ½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties & taxes of all materials with all labour, cess & T&P required for the work etc. complete in all respect. |
| 28 | Fly Ash brick masonry in cement mortar (1:6) in foundation and plinth using Fly Ash bricks of 25cmx12cmx8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work complete in all respect in all floors |
| 29 | Fly Ash brick masonry in cement mortar (1:6) in Superstructure using Fly Ash bricks of 25cmx12cmx8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work complete in all respect in all floors |
| 30 | Reinforced cemnet concrete of M-20 grade as per approved designs and drawing having a minimum compressive strength (in work test) of 200kg/cm2 in 15 cm cubes at 28 days after mixing and test conduct in accordance with I.S 456 and I.S 516 using 12 mm to 20 mm. size black hard crusher broken granite chips (20 mm. size chips not to exceeds 25%) and screened and washed sharp sand for mortar of approved quality from approved quarry to be mixed in concrete mixture including hoisting,lowering, laying and compacting concrete by using vibrators, wateringand curring for 28 days, centering and shuttering then after dismantling and remoing debrish from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete but excluding cost and conveyance of M.S rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S rods or Tor steel tying the grills and placing in proper position as directed by the Engineer in charge. A) Footing |
| 31 | B) Column up to Plinth level |
| 32 | C) Plinth Beam |
| 33 | D) Lintel |
| 34 | E) Roof Slab |
| 35 | Labour for cutting, bending shifting to site tying & placing in position |
| 36 | 16mm (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after raking out the joints including watering and curing with cost with cost, conveyance, royalties and taxes of all materials with all labour, T&P required for the work etc. complete. |
| 37 | 12mm (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the joint including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 38 | 6mm thick cement plaster (1:4) and using slurry treatment to ceiling including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 39 | S/F/F of antiskid ceramic floor tiles in flooring using special plain/printed series ceramic floor tile of premium grade(having minimum thickness 7mm to 8mm & sie 300mm*300mm conforming to is13755 of approved quality and shade in floors, treads on steps |
| 40 | s/f/f of ceramic wall tiles….. |
| 41 | S/F of MS grill… |
| 42 | Supplying and Priming one coat with any aproved Primer. |
| 43 | Finishing wall with waterproofing of approved shade on new work 2 coats of weather coat to give an even shade .... |
| 44 | Finishing wall surface with acrylic wall putty (Water based) of approved make and finished smooth and even surface receive painting including cost of scaffolding staging charges with cost of all materials, taxes with labour etc. complete as pee direction of Engineer- in-charge. |
| 45 | Wall Painting Two coats with plastic emulsion paint of approved quality over a coat of primer to interior wall surface including cost of paint, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect. |
| 46 | Painting two coats with any approved synthetic enamel paint of approved quality shade and make over a coat of priming to new wood work / iron work including cost of the primer and paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect. |
| 47 | ENTRANCE PATHWAYEarth work in excavation of foundation trenches in hard soil including dressing and leveling the bed and depositing the soil within 50M initial lead and 1.5M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3M in depth and as per the direction of the EIC. |
| 48 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties & taxes of sand with labour & T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 49 | Plain Cement concrete (1:2:4) using 20mm to 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour and T&P etc. required for the work complete. |
| 50 | Rigid and smooth centering and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor. |
| 51 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and approved size and design shape laid required colour and pattern over and including 50mm thick compacted bed of coarse sand filling the joints with coarse sand etc. |
| 52 | IMPROVEMENT OF PARKEarth work in hard soil or gravelly soil within 50M initial lead and 1.5M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3M in depth and as per the direction of the Engineer-in-charge. |
| 53 | Earth work in excavation of foundation in all kinds of soil including moorum, stony earth mixed with boulders (except sheet rocks and boulders requiring blasting) with all leads and lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour and T&P and dewatering if required for the works etc. complete as directed by the Engineer-in-charge. |
| 54 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 55 | Cement concrete of proportion (1:3:6) in foundation using 4cm (1 ½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties & taxes of all materials with all labour, cess & T&P required for the work etc. complete in all respect. |
| 56 | Plain Cement concrete (1:2:4) using 20mm to 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour and T&P etc. required for the work complete. |
| 57 | Fly Ash brick masonry in cement mortar (1:6) in F & P using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and taxes of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. [Vide AR(P) 71 item No.3] |
| 58 | Gurad Room |
| 59 | Reinforced cemnet concrete of M-20 grade as per approved designs and drawing having a minimum compressive strength (in work test) of 200kg/cm2 in 15 cm cubes at 28 days after mixing and test conduct in accordance with I.S 456 and I.S 516 using 12 mm to 20 mm. size black hard crusher broken granite chips (20 mm. size chips not to exceeds 25%) and screened and washed sharp sand for mortar of approved quality from approved quarry to be mixed in concrete mixture including hoisting,lowering, laying and compacting concrete by using vibrators, wateringand curring for 28 days, centering and shuttering then after dismantling and remoing debrish from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete but excluding cost and conveyance of M.S rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S rods or Tor steel tying the grills and placing in proper position as directed by the Engineer in charge. A) Lintel |
| 60 | B) Plinth Bend |
| 61 | E) Roof Slab |
| 62 | Cutting, Straightening coiled or bent up M.S. rods or Tor steel (Fe-500) SAIL make welding or jointing if necessary, bending, tying the grills and laying in position as required for R.C.C. works and hoisting, lowering and palcing in position in all floors according to approved designs and drawings including cost, conveyance, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P etc. complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S rod/ Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost) |
| 63 | 12mm (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the joint including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 64 | 16mm (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after raking out the joints including watering and curing with cost with cost, conveyance, royalties and taxes of all materials with all labour, T&P required for the work etc. complete. |
| 65 | 20mm (3/4\\") thick cement plaster (1:2:2) using 1 part cement 2 part sand and 2 part 4.75mm c.b.h.g. chips [Vide AR page-106/17] |
| 66 | Supplying, fitting, fixing vetrified tiles in floors of following size of approved make confirming to IS: 13755 laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, T&P etc. required for the work all complete as per direction of Engineer-in-charge (For new work only) |
| 67 | Priming one coat to wall surface with water bound cement primer including cost, conveyance, taxes of all materials, labour and T&P etc. complete |
| 68 | Existring Boundry wall |
| 69 | Painting two coats with weather seal coat paint including cost, conveyance, taxes of all materials, labour and T&P etc. complete |
| 70 | Existring Boundry wall |
| 71 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and approved size and design shape laid required colour and pattern over and including 50mm thick compacted bed of coarse sand filling the joints with coarse sand etc. |
| 72 | R.R. stone masonry in cement mortar (1:6) in F/P using H.B. broken & rough dressed granite stone of approved size and quality from approved quarry including splays cutting, circular moulding & similar such type of work with necessary projections, chamfering and corbelling, watering and curing etc complete |
| 73 | SHED FOR STEPS TO MANDIREarth work in excavation of foundation in all kinds of soil including moorum, stony earth mixed with boulders (except sheet rocks and boulders requiring blasting) with all leads and lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour and T&P and dewatering if required for the works etc. complete as directed by the Engineer-in-charge. |
| 74 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 75 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm (1 ½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with all labour, cess and T&P required for the work etc. complete in all respect. |
| 76 | Supplying, fitting and fixing G.C.I. Sheet in roof drilling holes in wind ties including fixing of ridges valleys wind ties etc. including cost of sheet & fittings etc. complete per 1 Sqm (Vide AR-125/32) |
| 77 | Hoisting joists and trusses and placing in position(L/C only) Data for 0.508qtl |
| 78 | Cost of MS pipes Please Enable Macros to View BoQ information |