| 1 | Excavation in foundation in ordinary soil (Loam,clay or sand ) including lift upto 1.50 m and lead upto 30m , including filling watering and ramming of excavated earth into the trenches and removal & disposal of surplus earth as directed by the Engineer-in-charge up to the distance of 30.00m from the foundation trench ... complete item. |
| 2 | Supply and filling of Sand in under floor … complete item |
| 3 | Cement Concrete with 4cm gauge approved stone ballast , coarse sand and cement in the proportion of 8:4:1 including supply of all material and labour, Tools & Plants etc. required for proper completion of the work. |
| 4 | M-150 brick work 1:4 cement coarse sand mortar in foundation …. Complete item, S.I-305a |
| 5 | Earth work in cutting or in embankment in ordinary soil excavated to be in the form of regular pits not exceeding 0.50m in depth and earth work in embankment to be in 20cm layers including ramming and dressing the surface to required levels and slopes and also including 1.50m lift and 30 m lead.(With 8.00KM cartage) |
| 6 | Supplying /Fixing of stain less Steel Railing in Horizontal railing using 4 no 20mm dia bar and on Top of Railing using 50 mm dia of Steel pipe with 80 mm dia master piller including cost of material fixtures handles locks screw fastner and necessary bending etc as required for proper completion of the work as per direction of engineer incharg |
| 7 | Providing and Fixing Precoated Galvanised iron Profile sheet …. Complete item.11.20 |
| 8 | P/Laying of I - Shaped Interlocking tiles Rubber moulded 80 mm thick Precast Cement Concrete having compressive strength not less than 30 Mpa and weight 5 kg (Specification confirming to IS : 15658-2006 ),Red colour |
| 9 | Supply And Fixing of chequreed Pre cast cement concrete tiles 22 mm thick…. Complete item |
| 10 | Add Cartage of structure from work shop to site …complete. |
| 11 | Providing & fixing of reflective signs with a corrosion resistant 4 mm thick with 04 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High Intensity prismatic sheeting type IV as per IRC 67 2012 retro reflective |sheeting with back frame MS angle of 35x35x5 mm. Legends, letters, numerals and borders etc should be as per MORTH specification No-801.3.7 The sheeting shall have a pressure sensitive adhesive of the aggressive-tack type requiring no heat, solvent other preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacturer. The ACM (Aluminium Composite Materials) shall be fixed on the Back frame MS Angle with riveting, Micro prismatic type IV Retro reflective sheeting |Confirming to ASTM D4956-09 shall be Pressure fixed. The Retro reflective sheeting |shall be tested for a certificate or having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67-2012 & Proof of the same Report shall be uploaded which quoting |tende:. The rate shall include all materials, labour, T&P, transportation, installatic.. and incidentals all complete as per direction of the Engineer-in - charge MORTH 80 |
| 12 | Supply and fixing of board … complete Please Enable Macros to View BoQ information |