| 1 | Labour charge for chipping of floor finish in cement mortor etc complete. |
| 2 | Labour charge for chipping of wall in cement mortor etc complete. |
| 3 | Supplying and fixing in position best white glazed earthenware Oriya type INDIAN WATER CLOSET of approved quality (Nayayasis make) of size 584mm with 'P' or 'S' trap and embedding the closet with trap to floor in position with 40mm brick jelly complete 1:2:5 (One part, two sand and five brick jelly) and finishing the top to the required slope and including giving connection to the S/L soil pipe(s) by dismantling the masonry floor or RCC works and restoring the same to the original condition without anyleakage etc. complete as directed by the departmental officers. |
| 4 | PLASTERING with cement mortar 1:5 (one cement and five sand)12mm thick in all floors including curing complying with standard specifications |
| 5 | DADOING THE WALLS with colour glazed ceramic tiles of size 3004509mm of best approved quality in cement mortar 1:2 (One cement and two sand) and pointing with white cement evenly to full depth of tiles in all floors as directed by the departmental officers and complying with standard specification |
| 6 | REFLOORING with Joint free rectified glazed CERAMIC TILES (colour with design) of approved quality and colour of size 305x305x8mm in all floor over 20mm thick cement mortor 1:3 (one cement, three sand) base above the existing bed concrete and pointing with same colour cement added with colouring pigment etc., complete complying standard specification. |
| 7 | Supplying and fixing soild PVC door Shutter using 19 gauge 19 mm MS Square tubes for styles and outer frames. 15 mm MS square tubes for top, lock and bottom rails. The Steel tubes shall be covered with 5 mm Thick solid pvc sheets. Shutter using 5mm Thick solid PVC Sheet for panelling shall rigidly fixed in position including necessary furniture and fittings. The Over all size of styles shall be 50 mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75 mm x30 mm.The Over all size of frames shall be 50 mm x 45 mm with suitable rabate for housing the shutter |
| 8 | FLOORING with Double charged nano VERIFIED TILES of approved quality and colour of size 600X600X8 mm in all floors over 20mm thick cement mortar 1:3 (one cement and three sand) base above the existing bed concrete and pointing with same colour cement added with colouring pigments complete complying with 13 standard specification. |
| 9 | Supplying PAINTING TWO Coats in the best approved first quality of plastic emulsion paint in the wall over one primary coat of wall primer including cost of paint and other materials, brushes, scaffolding charges etc., including clearing the existing surface by manual labour etc., complete complying as directed by the departmental officers as per standard spefication |
| 10 | Removing the one course of pressed tiles laying with base cement mortor in RCC roof finish and dismantled material conveyed by head load to outside as directed by the corporation officers. |
| 11 | Repairing the damaged plasering exposed RCC surface chipping and chisseling the damaged surface and then finishing the same surface with cement mortor 1:3 ( one cement and three M.sand )with an 10 mm thick including necessary scaffolding wherever necessary etc complete as directed by the corporation officers. |
| 12 | PLAIN CEMENT CONCRETE 1:2:4 (One cement, two M.sand and four aggregate) using 10mm gauge hard granite stone jelly for top roof flooring including dewatering if found necessary and laid in layers of not more than 15cm thick, well rammed etc., complete complying with standard specification. |
| 13 | Plastering roof flooring in cement mortar 1:3 ( One cement and Three M.Sand ) 20 mm thick including neat finishing, curing etc. complete complying standard specification as direced by the departmental officers. |
| 14 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (UPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25x24x25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60x74mm. The profiles should have co-extruded seals. Hardware: all the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass/6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving MS electroplated screws into plug. |
| 15 | Supplying removing and fixing aluminium window with 4 mm glass, lock etc., complete as per the instruction of corporation official. Please Enable Macros to View BoQ information |