| 1 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (UPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all cirner hoints mitred and fusion welded. Windows should be steel reinforced with 25x24x25mm steel reinforcemnet with a thickness of 1mm to have dimensional stability. The sash should be of 60x74mm. The profiles should have co-extruded seals. Hardware: all the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass/6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly tot he plastered brick wall using self expanding nylon plug and driving MS electroplated screws into plug. |
| 2 | Supplying and fixing UPVC windows and casement type (open) from the profile the size of outer frame 60mm x 58mm and the shutter profile are reinforcement with GI /1mm 125GSM and 100% corrosion free, the profiles are multi chambered section wall thick of 2mm. The EPDM rubber (Black colour) covered with over all the edges of frames and shutter the shutter will be provided with ESpag multi unit power locks also operate it as handle. The corners and joints should be welded and cleaned.Radiation free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow laekage of water even atmost ranging stroms and should has key lockable action , security protective hinges, strong locking system and as per size for arresting noise and energy loss. The connecting mechanism betwenn sash and outer frame that enables the opening of the windows. The windows should be fixed to the wall with 100% packing with screw and silicon packing all round the frames. The windows should be got approved from the executive engineer before use on work. |
| 3 | Painting the ceiling /wall surface with one coat of cement painting with white cement over plain surface including labour cost of paint, brush etc..Complete as standard specification. |
| 4 | Supplying and PAINTING the old wall surface with two coat of synthetic enamel paint over the existing priming coat. The rate is inclusive of cost of all materials and labour, brushes etc.. complying with standard specification. |
| 5 | Supplying and PAINTING OLD plastered wall surfaces in all floors with two coats approved quality and colour of Emultion paint over priming one coat with white cement. The rate is inclusive of cost of all materials and labour, brushes etc complying with standard specification. As directed by the departmental officers |
| 6 | Supplying and fixing for Air conditioner ,stbilizer,Double pole MCB with box 20amps ,3 core 205 sg.mm cable with wire , 4x20 sg.mm Alu.UG Cable, 63 amps TPN Main switch etc., complete as per standared specification as directed by the corporaion officers. |
| 7 | Supplying and fixing in position best white colour EUROPEAN WATER CLOSET of approved Quality with 'P' or 'S' trap with double flapped seat cover 12.50 lits capacity pvc low lavel flshing tank inculding all internal fittings fixed on c i brackets 12mm pvc or brass nipple cromium plated brown headed stop cock ,12mm niylon connection with nessary teekwood plges ,cews to the portion coming with walls and floors,including dismantling masnory and redoing the to the original condition etc., complete as directed by the departmental officers.( The water closet should be got approved by the departmental officer before use on work ) |
| 8 | Charges for repairing the damaged plastered surface chipping and chissiling the damaged surface and removing the loosened portions and than finishing the same surface with cement mortar 1:3(one cement and three sand ) with an average thickness of more than 25mm tk in two layers not more than 12mm tk(for each layers) including providing necessary scaffolding arrangements with required casurina poles cost of coir labour etc including cost and conveyance of all material required for above work & labour charges for all works as directed by the corporation officers. |
| 9 | Renowing supplying and fixing in possition bet indian make glazed erthanware WASH HAND BASIN of 560x406mm with apair of c I brackets 15mm dia c p piler tap ,32mm g I waste watwater pipe 32mm dia c p brass wast copling with chain 15mm dia pvc connection 15mm 3meter wheel valve wiyh isi mark and nessary g i union and g i elbow including fixing wash hnd basin in position with white lead clamps teakwood plgs screws ruber washer ect., complete with out any leakage complying with standared specification . |
| 10 | Supplying and fixing in position of Indian make white glazed earthenware lipped mouth or flat back lipped Urinal with 32mm bell mouth PVC or lead waste pipe, and fixing the Each Urinals in position with necessary teak wood plugs, clamps, Screws, white lead etc., including dismantling and re-doing the same to the original condition. As directed by the departmental officers. |
| 11 | Supplying and fixing of prepainted Galvalum Iron sheet with the following specification. The material shoud be of PPGI tile profile with a red or any other colour approval design 0.47mm thick 24gauge having width of 1050mm the sheet should be GI based precoated lot tipped Galvanished Iron shett and to be fixed with self tapping swers , plastic washer and swers to be fixied by using minute power machien drelled without damaging the sheet, paint coating of Z 120 GSM paint thickness the finish with the terracoat finish optional matt finish. the sheet should be fixed with making shootable corrugated cutting sheet in to be required size and making ornamental designs asper the site condition as directed by the corproation officers. As directed by the departmental officers. |
| 12 | Supplying and fabrication errecting and fixing Hilux or equivalent board false cealing up to a celing hight of 4.5mt from floor level by Using Hilux Board plain sheets (10mm tk) As directed by the departmental officers. |
| 13 | Supplying and fitting for window screen and as per standared specification as directed by the corporation officers Please Enable Macros to View BoQ information |