| 1 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) including demolition of brick or stone boulder masonry, built in cement mortar including all quoins, arches, Pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 2 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement including taking down cement or cement lime plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 3 | M&L for rendering 15 mm thick in CM (1:4) with water proofing compound (@ 3% by weight of cement) on fair faces of brick work or concrete surface finishing the surface even and fair including taking down cement or cement lime plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid separately.) |
| 4 | M&L for rendering 10 mm thick in CM (1:3) on concrete surface and finishing the surface even and smooth without using extra cement as on ceiling including taking down complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick in CM (1:6) on other than fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for rendering 15 mm thick in CM 1:4 with water proofing compound (@ 3% by weight of cement) on fair faces of brick work or concrete surface finishing the surface even and fair complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid separately.) |
| 7 | M&L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of 1mm thick wall care putty complete all as specified and directed.Note: Oil bound distemper shall be carried out through roller. |
| 8 | M&L for preparation of new plastered surfaces of fineshed walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 : 2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and inculding priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed. Note :- Primer and emulsion to be carried out through air less spray machine (Mechanical means).The work for periodical services shall include the following and the rates quoted by the bidder shall include the same:-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE.(b) The contractor shall upload with the documents under cover-I \\"Memorandum of Understanding\\" (MoU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected.(c) Use of scaffolding, trestles, ladders,cradles etc necessary for execution of work and protective measures.(d) Removing of Nails, making good holes, cracks etc.(e) Work in patches and in narrow/widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass, joinery electric fittings, wiring etc, Drop and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(h) Sample patch of 10Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. |
| 9 | M & L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 10 | Complete removal of existing treatment on wall/roof projections including facia, corneces etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilld labour complete all as specified and directed. |
| 11 | M & L for preparation of old plastered surfaces of fineshed walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 : 2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and inculding priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed. Note :- Primer and emulsion to be carried out through air less spray machine (Mechanical means). The work for periodical services shall include the following and the rates quoted by the bidder shall include the same:-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE.(b) The contractor shall upload with the documents under cover-I \\"Memorandum of Understanding\\" (MoU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected.(c) Use of scaffolding, trestles, ladders,cradles etc necessary for execution of work and protective measures.(d) Removing of Nails, making good holes, cracks etc.(e) Work in patches and in narrow/widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass, joinery electric fittings, wiring etc, Drop and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(h) Sample patch of 10Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work. |
| 12 | M & L for providing and applying minimum 1mm thick weather proof exterior wall care putty over prepared surfaces to achieve the surface even and smooth for painting complete all as specified and directed. |
| 13 | M & L for preparation of old treated surfaces of ceiling and applying two coats of white wash complete all as specified and directed. |
| 14 | M & L for preparation of old steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint at any height complete all as specified and directed. |
| 15 | Supply only integral water proofing compound conforming to IS 2645 complete all as specified and directed. |
| 16 | M & L for preperation of surface of wall/chajja and applying a coat of tapecrete P-151/Cemcrete acrylic polymer modified cementitious slurry consisting of one part of TAPECRETE P-151, two parts of cement by weight complete all as specified and directed. |
| 17 | Cutting into existing manholes for connecting new drains of 100mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 18 | S & F in repair PP (Polypropylene) Drainage Pipe – Drain PRO 110 mm dia, heavy duty, single socketed, in standard lengths, conforming to EN 1451 / IS 1729 (as applicable), suitable for soil, waste and rainwater drainage applications. Pipe shall be joined with shield coupling complete with EPDM rubber gasket, stainless steel clamp/band, ensuring leak-proof and flexible joint. The pipe shall be chemically resistant, corrosion-free, smooth internal bore, UV stabilized and noise-reduced, capable of withstanding normal building drainage temperatures and pressures. Item includes cutting, laying, aligning and fixing of pipes in trenches, ducts, chases or floors, proper bedding/support, making joints, testing for leakage, refilling, making good to disturbed surfaces and disposal of debris complete all as specified and directed. |
| 19 | S & F in repair of any type of existing pipe have replace with PP (Polypropylene) Drainage Pipe – Drain PRO 110 mm diameter, heavy duty, single socketed, in standard/required lengths, conforming to EN 1451 / IS 1729 (as applicable) suitable for soil, waste and rainwater drainage, laid complete. Pipes shall be jointed with shield coupling complete with EPDM rubber gasket and stainless-steel band/clamps of the same approved make and compatible with the pipe size, ensuring leak-proof, flexible and vibration-resistant joints. The item includes supplying and fixing of stack/support clamps of the same approved make as the PP pipes, fixed to walls at a maximum spacing of 1500 mm c/c, including drilling, anchoring, grouting and making good to masonry or concrete surfaces. The rate shall include cutting, laying, aligning, jointing, fixing, testing for leakage, refilling, making good to disturbed surfaces, disposal of debris, and all labour, materials, tools and accessories complete all as specified and directed. |
| 20 | S & F in repair PP (Polypropylene) Drainage Pipe – Drain PRO 75 mm dia, heavy duty, single socketed, in standard lengths, conforming to EN 1451 / IS 1729 (as applicable), suitable for soil, waste and rainwater drainage applications. Pipe shall be joined with shield coupling complete with EPDM rubber gasket, stainless steel clamp/band, ensuring leak-proof and flexible joint. The pipe shall be chemically resistant, corrosion-free, smooth internal bore, UV stabilized and noise-reduced, capable of withstanding normal building drainage temperatures and pressures. Item includes cutting, laying, aligning and fixing of pipes in trenches, ducts, chases or floors, proper bedding/support, making joints, testing for leakage, refilling, making good to disturbed surfaces and disposal of debris complete all as specified and directed. |
| 21 | S & F in repair of any type of existing pipe have replace with PP (Polypropylene) Drainage Pipe – Drain PRO 75 mm diameter, heavy duty, single socketed, in standard/required lengths, conforming to EN 1451 / IS 1729 (as applicable) suitable for soil, waste and rainwater drainage, laid complete. Pipes shall be jointed with shield coupling complete with EPDM rubber gasket and stainless-steel band/clamps of the same approved make and compatible with the pipe size, ensuring leak-proof, flexible and vibration-resistant joints. The item includes supplying and fixing of stack/support clamps of the same approved make as the PP pipes, fixed to walls at a maximum spacing of 1500 mm c/c, including drilling, anchoring, grouting and making good to masonry or concrete surfaces. The rate shall include cutting, laying, aligning, jointing, fixing, testing for leakage, refilling, making good to disturbed surfaces, disposal of debris, and all labour, materials, tools and accessories complete all as specified and directed. |
| 22 | S & F in repair PP (Polymer Pipes ) Bend (Drain PRO) with or without access door, bend, etc any radius 110mm size with shield coupling with EPDM rubber gasket complete all specified and directed |
| 23 | S & F in repair PP (Polymer Pipes ) Bend (Drain PRO) with or without access bend etc any radius 75 mm size with shield coupling with EPDM rubber gasket complete all specified and directed |
| 24 | S & F in repair PP (Polymer Pipes ) Tee (Drain PRO) 110 mm Tee, equal or unequal complete all specified and directed |
| 25 | S & F in repair PP (Polymer Pipes ) Tee (Drain PRO) 75 mm Tee, equal or unequal complete all specified and directed |
| 26 | S & F in repair PP (Polymer Pipes ) Trap (Drain PRO) 110 mm bore floor trap including with shield coupling with EPDM rubber gasket complete all as specified & directed. |
| 27 | S & F in repair PP (Polymer Pipes ) Vent Cowl (Drain PRO) 110 mm dia vent cowl complete all as specified and directed. |
| 28 | S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps complete all as specified and directed. |
| 29 | S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps complete all as specified and directed. |
| 30 | S & F in repair 110mm bore PVC (SWR) bends complete all as specified and directed. |
| 31 | S & F in repair 110mm bore PVC (SWR) bends with access doors complete all as specified and directed. |
| 32 | S & F in repair 75mm bore PVC (SWR) bends complete all as specified and directed. |
| 33 | S & F in repair 75mm bore PVC (SWR) bends with access doors complete all as specified and directed. |
| 34 | S & F in repair 100mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 35 | S & F in repair 110mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 36 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frame including punching or drilling out old glazing pins/spring clips complete all as specified.and directed. |
| 37 | S & F Sheet glass 4mm thick ordinary quality and glazing with rubber bedding etc in suqares n exc 0.5 Sqm in each pane complete all as specified.and directed. |
| 38 | S & F 4 mm thick figured glass pin headed type and glazing with oil putty in square n exc 0.5 sqm in each pan complete all as specified and directed. |
| 39 | M & L for obliterating number plate and painting backgound using black synthetic enamel paint and building number with white synthetic enamel paint, overall area of plaque exc 0.10 Sqm but n exc 0.40 Sqm each complete all as specified and directed. |
| 40 | Uprooting of vegetation/plant growth from walls, roof, chajja, gutter etc and cleaning the surface and making good holes with cement mortar (1:3) each hole not exceeding 0.10 Sqm rate include up to three stories complete all as specified and directed. |
| 41 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 42 | M & L for providing precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab for man holes shelves and similar articles etc set in CM 1:4 incl necessary form work complete all as specified and directed. |
| 43 | M & L for Mild steel TMT bars 10mm dia and over as in reinforcement,cut to length bent to shape required including hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 44 | M & L for Mild steel TMT bars 6 to 8mm dia cut to length bent to shape required including cranking bending hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 45 | Demolition of PCC in ground floor and paving n exc 15cm thick below or above ground level complete all as specified and directed. |
| 46 | M & L for 40mm thick cement concrete 1:2:4, Type B-0 using 12.5 mm graded stone aggregate as in floors, finished even and smooth using extra cement complete all as specified and directed. |
| 47 | M & L for 38mm wide of glass dividing strips, 3mm thick and inserted in position to confirm design of flooring. all as specified and directed. |
| 48 | M & L for 50 mm thick cement concrete type C1 (1:3:6) using 20mm graded stone aggrtegate as in plinth protection including finsihing even & fair complete all as specified directed. |
| 49 | Dismantling stone slab and tiles of any description or and thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 50 | M & L for 75 mm thick Cement concrete 1:4:8, type D-2 using 40mm graded stone aggregate as in sub base etc complete all as specified and directed. |
| 51 | M&L for 60mm thick rubber moulded glossy finish coloured interlocking precast PCC pavers any colour of M-35 grade laid over 25mm thick sand cushioning and joint filled with fine sand incl levelling, tamping and sweeping etc complete all as specified and directed. |
| 52 | M&L for plain cement concrete 1:4:8, type D-2(using 40mm graded stone aggregate) as in foundation, filling & mass concrete including demolition of existing concrete complete all as specified and directed. |
| 53 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in benching, copings and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work including demolition of existing cement concrete complete all as specified and directed. |
| 54 | S & F for rotational moulded polyethylene water storage tanks 1000 Litre (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including dismantling of PVC water tanks of capacity exc 500 & n. exc 1000 ltr complete all as specified and directed. |
| 55 | S & F for 500 litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including dismantling of PVC water tanks and removing for capacity exceeding 250 litres & not exceeding 500 litres etc complete all as specified and directed. |
| 56 | S & F in repair angle valve cast copper alloy with capstain head chromium plated screwed down, high pressure with long shanks and fly nuts screwed for 15mm bore pipe complete all as specified and directed. |
| 57 | Extra for forming fair finished drain or channel, 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred, stopped ends complete all as specified and directed. |
| 58 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old asbestos cement (currugated or semi corrugated sheets etc) complete all as specified and directed. |
| 59 | S & F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old asbestos cement (currugated or semi corrugated sheets etc) complete all as specified and directed. |
| 60 | M & L for 150mm dia salt glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed. |
| 61 | M & L for concrete bed to drain pipes 1:4:8 type D-2 including packing under and haunching against the sides of pipe after they are laid and tested for 150mm dia complete all as specified and directed |
| 62 | Taking up or down steel tubing & connection 15mm bore complete all as specified and directed. |
| 63 | Taking up or down steel tubing & connection 20mm bore complete all as specified and directed. |
| 64 | Taking up or down steel tubing & connection 25mm bore complete all as specified and directed. |
| 65 | Refixing 15mm old steel tubing and connections in new or old positions (walls, ceiling, floor etc) including fittings (new or old serviceable) required complete all as specified and directed. |
| 66 | Refixing 20mm old steel tubing and connections in new or old positions (walls, ceiling, floor etc) including fittings (new or old serviceable) required complete all as specified and directed. |
| 67 | Refixing 25mm old steel tubing and connections in new or old positions (walls, ceiling, floor etc) including fittings (new or old serviceable) required complete all as specified and directed. |
| 68 | M & L for GI tubing medium grade 15mm dia galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 69 | M & L for GI tubing medium grade 20mm dia galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 70 | M & L for GI tubing medium grade 25mm dia galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 71 | S & F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball & fixed complete all as specified and directed. |
| 72 | S & F in repair Gun-metal, globe or gate valves 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 73 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 74 | M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 75 | M &L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwirse described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed. |
| 76 | Dismantling brick tiles or terracing tiles, single layer of roofs including demolition and removing of mud in roofs any thickness including plastering and leeping (whether full thickness removed or part thereof ) and demolition material disposed out from MoD land and including roughening surfaces of old concrete by picking, sweeping/Brushing clean and washing down with water to remove dust and apply neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed. |
| 77 | M & L for PCC 1:2:4, type B-0 (using 12.50mm graded stone aggregate) as in roof kerbs/roof padding /benching or mud stops, and platform for mounting service tanks, rounded, chamfered on edges including necessary use and waste of from work etc complete all as specified and directed |
| 78 | M&L for hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM (1:6) mixed with water proofing compound and jointed pointed in CM (1:3) mixed with 5% crude oil by weight of cement complete all as specified and directed. Please Enable Macros to View BoQ information |
| 79 | M&L for hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM (1:6) mixed with water proofing compound and jointed pointed in CM (1:3) mixed with 5% crude oil by weight of cement complete all as specified and directed. Please Enable Macros to View BoQ information |