| 1 | M&L for preparing old treated surface of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, grease spots etc and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 2 | M&L for preparation of old plastered or unplastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy soprts and applying one coat of antifungal exterior emulsion paint complete all as specified and directed. |
| 3 | M&L for preparing old painted wood/ wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 4 | M&L for preparing old painted steel/ iron surfaces by cleaning down surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 5 | M&L for preparation of old plastered or unplastered surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 6 | Taking down cement or cement lime plaster on concrete or brick/stone walls incl racking out joints hacking for key scrubbing down with water etc and removing rubbish outside MD land complete all as specified and directed. |
| 7 | M&L for rendering 10 mm thick cement plaster in cement mortar 1:6 on fair faces of brick work/ laterite masonry work/ PCC solid block masonry/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for rendering in two layers as 5 mm thick with cement mortar (1:4) mixed with water proofing compound @ 3% by the weight of cement over rendering 10mm thick with cement mortar (1:6) on fair faces of brick work on surfaces of wall finishing the surface fair and even complete all as specified and directed. Note: Water proofing compound will be measured and paid separately. |
| 9 | Supply only liquid water proofing compound all as specified and directed. |
| 10 | M&L for preparation of new plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 11 | M&L for preparation of new plastered wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 12 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and remove rubbish off the premises complete all as specified and as directed. |
| 13 | M&L for glazed ceramic coloured tiles in vertical surface 350x250x7 mm/ 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of the tile over and including 10 mm thick screed bed in cement mortar 1:3 complete all as specified and as directed. |
| 14 | M&L for non-skid ceramic tiles (coloured) 7 to 8mm thick, (Square/ rectangular), area of each tile exceeding. 0.11 Sqm but not exceeding 0.18 Sqm as in floor set and joint in cement slurry, jointed & pointed in white or coloured cement to match the surface of the tile over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 15 | M&L for vitrified ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 16 | M&L for vitrified ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick screed bed or bedding layer in cement mortar (1:3) complete all as specified and directed. |
| 17 | Attending minor complaints of joinery such as wooden/ steel/ aluminium of any description including pelmet box, cupboards, drawers and like door springs, rolling shutters etc requiring carpentry work like adjusting easing, cutting, pinning, welding and finally making good etc and functioning to seating over with each other with tightening of screws/ nails, door and helical springs, door closures, etc. including petty repairs material like screws/ nails, plug, grease, etc. to make it functional as in day to day maintenance work complete all as specified and as directed. |
| 18 | Attending minor complaints of plumbing and sanitary fittings including water leakage from taps, WCs, flushing systems, urinals, wash basins, flush pipes, bottle traps, tanks delivery pipe lines etc and any obstruction to water supply in rooms/ qtrs requiring plumber work with minor stores such as replacement of brass spindles, M seal, screws, nailing, washers, check nuts, short pieces, union, elbows, tightening fittings of flushing cistern etc complete all as specified and as directed. |
| 19 | Disconnecting existing tanks capacity exceeding 250 ltrs and not exceeding 500 ltrs, setting aside (or lowering if required) including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed. |
| 20 | Disconnecting existing tanks capacity exceeding 500 ltrs and not exceeding 1000 ltrs, setting aside (or lowering if required) including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and as directed. |
| 21 | M&L for 18/ 19 mm thick particle board, medium density, flat pressed,single layer type or three layer type with BWR type adhesive, fixedwith screws to timber frame work including dismantling boarding, anydescription, fixed in any position with screws complete all as specified and as directed. |
| 22 | Fixing only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.Note: Material will be issued under Sch 'B' store. |
| 23 | Dismantling water tanks of capacity exceeding 250 ltrs and not exceeding 500 ltrs and removing to store complete all as specified and directed. |
| 24 | S&F rotational moulded polyethylene water storage tanks, white, triple layered of capacity 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 25 | Dismantling water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs and removing to store complete all as specified and directed. |
| 26 | S&F rotational moulded polyethylene water storage tanks, white, triple layered of capacity 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 27 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed. |
| 28 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 29 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 30 | S&F anodised aluminium snap grid frame work of grid size 605 x 605 mm for false ceiling, including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 31 | M&L for 4 mm thickness non-asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ aluminium framework with screws fixed in ceiling flat or sloping complete all as specified and directed. |
| 32 | M&L for preparation of newly ceiling surfaces and applying two coats of distemper oil emulsion over a coat of chalk whiting complete all as specified and as directed. |
| 33 | Taking up or down 20 mm bore steel tubing and connections, removal to store complete all as specified and directed. |
| 34 | Taking up or down 25 mm bore steel tubing and connections, removal to store complete all as specified and directed. |
| 35 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brck walls complete all as specified and directed. |
| 36 | S&F 20 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 with all pipe fittings fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 37 | S&F 25 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 with all pipe fittings fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed. |
| 38 | Taking down and refixing shutters of any description not exceeding 1 sq.m each, including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.complete all as specified and directed. |
| 39 | Taking down and refixing shutters of any description exceeding 1 sq.m and not exceeding 2 sq.m each, including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.complete all as specified and directed. |
| 40 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 41 | S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty or fixed with beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 42 | S&F 3mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 43 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including fixing bolt, plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage etc complete all as specified and directed. |
| 44 | S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed. |
| 45 | Fixing in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed.Note: Material will be issued under Sch 'B' store. |
| 46 | S&F in repairs vitreous China wash basin, white, flat back, size 550 x 400 mm, including 15 mm dia cast copper alloy chromium plated pillar cock, CI brackets, 15 mm dia polythene connection, 32 mm dia waste coupling and 32 mm dia PVC waste pipe 450 mm long etc. complete all as specified and directed. |
| 47 | Fixing in repairs vitreous China wash basin, white, flat back, size 550 x 400 mm complete all as specified and directed.Note: Material will be issued under Sch 'B' store. |
| 48 | S&F in repairs pillar taps of size 15mm bore dia, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed. |
| 49 | Fixing in repairs pillar taps of size 15mm bore dia, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.Note: Material will be issued under Sch 'B' store. |
| 50 | S&F in repairs bib tap of size 15mm bore dia, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 51 | Fixing in repairs bib tap of size 15mm bore dia, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.Note: Material will be issued under Sch 'B' store. |
| 52 | S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 53 | Fixing in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.Note: Material will be issued under Sch 'B' store. |
| 54 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 55 | S&F in repairs looking mirror, size 600mmx450mm, bevelled edge, selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 56 | S&F grating square 150 mm size of PTMT (Minimum weight 100gms) complete all as specified and directed. |
| 57 | S&F in repairs 15 mm bore dia. angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 58 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 59 | Fixing in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.Note: Material will be issued under Sch 'B' store. |
| 60 | S&F in repairs 32 mm dia PVC (flexible) waste pipe for wash hand basin complete all as specified and directed. |
| 61 | S&F in repairs waste fittings brass chromium plated 32 mm mm dia for wash hand basin, glazed ware sinks etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 62 | S&F in repairs plastic water closet seat, white, closed pattern withflat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 63 | S&F in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed. |
| 64 | S&F in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. |
| 65 | Taking down shutters of any description not exceeding 1 sq.m each complete all as specified and directed. |
| 66 | Taking down shutters of any description exceeding 1 sq.m and not exceeding 2 sq.m each complete all as specified and directed. |
| 67 | Taking down chowkats or frames with shutters any description not exceeding 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 68 | Taking down chowkats or frames with shutters any description exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified and as directed. |
| 69 | Cutting holes in brick walls built in cement mortar of depth exceeding half brick but not exceeding one brick, for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed. |
| 70 | S&F mild steel works for flat iron as hold fast and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 71 | M&L for PCC 1:2:4, Type B0 (using 12.5mm graded stone aggregate) for fixing holdfast block and the like complete all as specified and directed. |
| 72 | M&L for second class hardwood, plain, solid straight chowkats & frames, wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including preservative treatment complete all as specified and directed. |
| 73 | M&L for second class hardwood, transomes or mullions, straight, for solid frames of any description, wrought, framed, double rebated on the solid, rounded or chamfered (including weathering to transome, if required put together with glue, pinned at joints) complete all as specified and directed. |
| 74 | M&L for second class hardwood plain, framed, paneled shutters 35 mm thickness (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 75 | M&L for second class hardwood glazed and skeleton shutters, 35 mm thick open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 76 | M&L for second class hardwood glazed and skeleton shutters, 30 mm thick open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. in windows, ventilators, etc. are provided with stiles and rails; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and as directed. |
| 77 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixing in opening as per specification & drawing complete all as specified and directed. |
| 78 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 79 | S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. |
| 80 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or fixed with beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 81 | Material and Labour for for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 82 | S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 83 | S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 84 | S&F 75 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 85 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 86 | S&F 100 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 87 | S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 88 | S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 89 | S&F 300mm mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 90 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, (overall length of cover plate 140mm) fixed in floor complete all as specified and directed. |
| 91 | S&F in repairs 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 92 | S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, (overall length of cover plate 140mm) fixed in floor complete all as specified and directed. |
| 93 | S&F in repairs 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 94 | S&F in repairs 100 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 95 | S&F in repairs 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 96 | S&F in repairs 100 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 97 | S&F in repairs 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 98 | S&F in repairs 75 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 99 | S&F in repairs chromium plated brass shower roses 125 mm size with or without swivel joints including fixing to steel/ PVC pipe or union complete all as specified and directed. |
| 100 | S&F shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour (Minimum weight 40gms complete all as specified and directed. |
| 101 | S&F in repairs 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) complete all as specified and directed. |
| 102 | Taking out and cleaning existing roof treatment of any description by wire brushing and cleaning top surface with water and remove the rubbish to outside MD land etc. and brushing with neat cement slurry at 3 Kg per Sqm on concrete surfaces. M&L for water proofing treatment to RCC roof with APP modified prefabricated five layer membrane of 4 mm thick and weight not less than 4.00 Kg per Sqm reinforced with non woven polyester matt reinforcement (weighing not less than 160 Gms/Sqm) having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 800 N/Sqcm, tearing strength of 180 Nm by torch application over a solvent based bitumen primer, Shalitex primer @ 0.20 Kg per Sqm of same manufacturers conforming to IS 3384-1986. APP membrane shall be fixed laid by torch application including minimum 7.50 cm side overlap and 10 cm end lap and painting over APP membrane sheet with aluminium bituminous paint @ 0.10 Ltr/Sqm. All cracks in roof shall be filled with cement putty using suitable bonding agent (Shalocrete 42) before lying cement plaster, including complete all as specified and directed. Please Enable Macros to View BoQ information |